Acknowledgement
Supported by : 부산대학교병원
References
- Branemark P-I, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O, Ohman A. Osseointegrated implants in the treatment of the edentulous jaw: Experience from a ten year period. Scand J Plastic Reconst Surg 1977;11(suppl)
- Adell R, Lekholm U, Rockler B, Branemark P-I. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416 https://doi.org/10.1016/S0300-9785(81)80077-4
- Albrektsson T. A multicenter report on osseointegrated oral implants. J Prosthet Dent 1988;60:75-84 https://doi.org/10.1016/0022-3913(88)90355-1
- Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Tronto study. Part I: Surgical results. J Prosthet Dent 1990;63:451-457 https://doi.org/10.1016/0022-3913(90)90237-7
- Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Tronto study. Part II: The prosthetic results. J Prosthet Dent 1989;64:53-61
- Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Tronto study. Part III: Problems and complications encountered. J Prosthet Dent 1990;64:185-194 https://doi.org/10.1016/0022-3913(90)90177-E
- Jaarda MJ, Razzoog ME, Gratton DG. Effect of preload torque on the ultimate tensile strength of implant prosthetic retaining screws. Implant Dent 1994;3:17-21 https://doi.org/10.1097/00008505-199404000-00002
- Jemt T. Modified single and short-span restorations supported by osseointegrated fixtures in the partially edentulous jaw. J Prosthet Dent 1986;55:243-7 https://doi.org/10.1016/0022-3913(86)90352-5
- Jemt T, Lekholm U, Grondahl K. 3-year followup study of early single implantb restorations ad modum Branemark. Int J Periodontics Restorative Dent 1990;10:340-9
- Rangert B, Jemt T, Jrnus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants 1989:4:241-247
- Rangert B, Sullivan R. Learning from history The transition from full arch to posterior partial restorations. Nobelpharma News 1995;9(2):67
- Misch CE, Wang HL, Misch CM, Sharawy M, Lemons J, Judy KW. Rationale for the application of immediate load in implant dentistry: Part I. Implant Dent 2004;13:207-17 https://doi.org/10.1097/01.id.0000140461.25451.31
- Shigley J. Mechanical Engineering Design,ed 3. New York: McGraw Hill, 1987:227-52
- Robb TT, Porter SS. Increasing abutment screw rotation by applying a thingold coating [abstract 1641]. J Dent Res 1998;77(special issue):837
- Robb TT, Porter SS. Increasing implantabutment preload by thin gold coating abutment screws [abstract 1642]. J Dent Res 1998;77(special issue):837
- Martin WC, Woody RD, Miller BH, Miller AW. Implant abutment screw rotations and preloads for four different screw materials and surfaces. J Prosthet Dent 2001;86:24-32 https://doi.org/10.1067/mpr.2001.116230
- Vigolo P. Cemented versus screw-retained implant- supported single tooth crowns: A 4-year prospective clinical study. Int. J Oral Maxillofac Implants 2004; 19:260-5
- Liu Y, Gubisch M, Hild W, Scherge M, Spiess L, Knedlik Ch, Schaefer JA. Nanoscale multilayer WC/C coatings developed for nanopositioning. part II: Friction and wear. Thin Solid Films 2005;488: 140-8 https://doi.org/10.1016/j.tsf.2005.03.020
- Choi JU, Jeong CM, Jeon YC, Lim JS, Jeong HC, Eom TG. Influence of tungsten carbide/carbon http://searchc.naver.com/ntk/coating on the preload of implant abutment screws. J Korean Acad Prosthodon 2006;44:229-42
- Park JK, Jeong CM, Jeon YC, Yoon JH. Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening. J Korean Acad Prosthodon 2008;46:137-47
- McGlumphy EA, Mendel DA, Holloway JA. Implant Screw Mechanics. Dent Clinics North Am 1998; 42:71-89
- Schwarz MS. Mechanical complications of dental implants. Clin Oral Impl Res 2000;11:156-8 https://doi.org/10.1034/j.1600-0501.2000.011S1156.x
- Motosh N. Development of design charts for bolts preloaded up to the plastic range. J Eng Ind 1976;98:849-51