• 제목/요약/키워드: zirconia block

검색결과 60건 처리시간 0.022초

Analysis of surface characteristics of (Y, Nb)-TZP after finishing and polishing

  • Seong-keun, Yoo;Ye-Hyeon, Jo;In-Sung Luke, Yeo;Hyung-In, Yoon;Jae-Hyun, Lee;Jin-Soo, Ahn;Jung-Suk, Han
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권6호
    • /
    • pp.335-345
    • /
    • 2022
  • PURPOSE. This in vitro study aimed to evaluate the surface characteristics of a full veneer crown fabricated chairside (CS) from a (Y, Nb)-TZP zirconia block in response to conventional zirconia grinding and polishing. MATERIALS AND METHODS. Zirconia crowns (n = 40) were first prepared and divided into two groups of materials: Labside (LS) and CS, after which each specimen went through a five-step grinding and polishing procedure. Following each surface treatment, surface characteristics were analyzed using confocal laser microscopy (CLSM), average surface roughness (Ra) values were processed from the profile data through Gaussian filtering, and X-ray diffraction pattern analysis was performed to evaluate the monoclinic (M) phase content. Then, a representative specimen was selected for field-emission scanning electron microscopy (FE-SEM), followed by a final analysis of the roughness and X-ray diffraction of the specimens using the independent t-test and repeated measures analysis of variance (RM-ANOVA). RESULTS. In every group, polishing significantly reduced the Ra values (P < .001). There was no significant difference in Ra between the polished state CS and LS. Furthermore, CLSM and FE-SEM investigations revealed that even though grain exposure was visible in CS specimens throughout the as-delivered and ground states, the exposure was reduced after polishing. Moreover, while no phase transformation was visible in the LS, phase transformation was visible in CS after every surface treatment, with the M phase content of the CS group showing a significant reduction after polishing (P < .001). CONCLUSION. Within the limits of this study, clinically acceptable level of surface finishing of (Y, Nb)-TZP can be achieved after conventional zirconia polishing sequence.

CAD/CAM으로 제작한 유전치 지르코니아 전장관의 두께에 따른 파절강도와 반투명도 비교 (Fracture Strength and Translucency of CAD/CAM Zirconia Crown for Primary Anterior Tooth)

  • 옹승환;김종수;김종빈;신지선;유승훈
    • 대한소아치과학회지
    • /
    • 제47권2호
    • /
    • pp.205-212
    • /
    • 2020
  • 이 연구의 목적은 파절강도와 반투명도 측정을 통해 Computer Aided Design/Computer Aided Manufacturing (CAD/CAM)으로 제작한 유전치 지르코니아 전장관의 임상적 적용 가능성을 확인하는 것이다. 기성 유전치 모형 중 #61을 스캔하여 얻은 3차원 형상 데이터로 CAD 디자인 프로그램을 이용하여 전장관을 디자인하고, 지르코니아 블록으로 CAM 밀링 기계를 이용하여 전장관을 제작하였다. 지르코니아 전장관은 두께에 따라 0.3, 0.5, 그리고 0.7 mm의 3군으로 나누어 1.0 mm 두께의 레진 전장관과 파절강도를 비교하였다. 파절강도는 만능시험기를 이용하여 30° 각도에서 1 mm/min 속도로 절단면에 하중을 가하여 측정하였다. 반투명도는 가로와 세로가 7.0 mm, 그리고 두께가 각각 0.3, 0.5, 0.7 mm 인 사각형 지르코니아 시편을 제작하여 분광측색장치로 측정하였다. 파절강도 측정 결과 지르코니아 전장관은 두께가 증가할수록 파절강도가 높아졌으며 모든 두께의 지르코니아 군에서 대조군인 레진 전장관보다 파절강도가 높았다(p < 0.05). 반투명도는 0.3 mm 군에서 가장 높았으며 0.5, 0.7 mm로 두께가 증가할수록 감소하였다(p < 0.05). CAD/CAM으로 제작한 지르코니아 전장관은 개별 치아에 맞추어 얇게 디자인 및 제작 가능하며, 얇은 전장관을 이용한 수복은 임상적으로 치아 삭제량과 치수노출 위험성 감소 뿐만 아니라, 더 심미적인 수복을 가능하게 해줄 것이다.

Implant에 사용되는 CAD/CAM 전용 zirconia abutment의 표면적과 디자인에 따른 유지력 차이 (Differences in retention of the reduction direction depending on dimensions and design CAD/CAM zirconia abutment for implant)

  • 남택모;김한곤;김병식;임시덕
    • 대한치과기공학회지
    • /
    • 제32권4호
    • /
    • pp.317-325
    • /
    • 2010
  • Purpose: The aim of this study is to make some basic materials to find retention force difference based on the total height of CAD/CAM zirconia abutment used for implant, retention force difference based on how to regulate the height of the abutment, retention force difference based on the size and retention force difference based on the design group. Methods: The retention force was measured by being pulled at the speed of 1mm/min after being combined with zirconia block and abutment using Temp-BOND of Kerr. The experiment was done at the research lab of OSTEM in Busan by useing UNIVERSAL TESTING MACHINE on March 3rd, 2010. Results: After analysing the total height and the retention force, p-value had minor difference by 0.01 statistically. Namely, 3mm, 4mm, 5mm had the retention force difference and we could see retention force difference on 3mm and 5mm at the post test. After analyzing how to regulate the height and retention force, p-value had minor difference by 0.000 statistically. Namely, 1mm and 2mm had the retention difference and we could see that 1mm and 2mm with the total height had retention difference. After analyzing the retention force based on the size, p-value had minor retention force difference by 0.000 statistically. Namely, 7 different size had retention force difference and we could see the size 21.9mm, 32.9mm, 32.9mm, 38.4mm, 48.9mm and 54.9mm had retention force difference. Conclusion: Namely 9 different design group had retention difference and we could see that 9 design group with 5.6.7.8 design group and 9 design group with 1.2.3.4. design group had retention force.

석고 모형재와 고무인상재의 젖음성이 지르코니아 코핑의 변연적합도에 미치는 영향 (Effect of wettability of gypsum materials and rubber impression material on the marginal fitness of zirconia copings)

  • 김원영;정인성;전병욱
    • 대한치과기공학회지
    • /
    • 제38권4호
    • /
    • pp.255-262
    • /
    • 2016
  • Purpose: This study examined the effect of wettability of gypsum materials and rubber impression material on the marginal fitness of zirconia copings. Methods: Three commercially available gypsum materials(Fugirock EP, Snow Rock, Tuff Rock) and three zirconia blocks(iJAM Emerald, LUXEN Smile block, ICE Zirkon transluzent) were studied. The zirconia copings were fabricated by using dental CAD/CAM system. Contact angles on the impression materials were measured with contact angle measuring device. Silicone replica method was used to measure the marginal fitness and cutting was performed on the bucco-lingual and mesio-distal sides. It were observed with a stereomicroscope at °ø40 magnification. The data were statistically analyzed with One-way ANOVA. Results: Mean values of contact angles were $58.3{\pm}0.7^{\circ}$ for Tuff Rock, $77.5{\pm}0.5^{\circ}$ for Fugirock EP and $87.8{\pm}0.5^{\circ}$ for Snow Rock and the difference between them was statistically significant(p<0.05). The smallest values of marginal fitness for the JF groups were $30.7{\pm}3.0{\mu}m$ for bucco-lingual direction, $29.3{\pm}3.0{\mu}m$ for mesio-distal direction. One-way ANOVA showed statistically significant difference between groups for marginal fitness(p<0.05). Conclusion: Tuff rock gypsum material had superior wettability to others. The mean marginal fitness of the Tuff rock gypsum material group were significantly better than other groups. Thus they can be also expected to show clinically satisfactory marginal fitness.

In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies

  • Ozal, Cise;Ulusoy, Mutahhar
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권6호
    • /
    • pp.373-384
    • /
    • 2021
  • PURPOSE. This study aimed to compare the marginal and internal fit of 3-unit monolithic zirconia restorations that were designed by using the data obtained with the aid of intraoral and laboratory scanners. MATERIALS AND METHODS. For the fabrication of 3-unit monolithic zirconia restorations using impressions taken from the maxillary master cast, plaster cast was created and scanned in laboratory scanners (InEos X5 and D900L). The main cast was also scanned with different intraoral scanners (Omnicam [OMNI], Primescan [PS], Trios 3 [T3], Trios 4 [T4]) (n = 12 per group). Zirconia fixed partial dentures were virtually designed, produced from presintered block, and subsequently sintered. Marginal and internal discrepancy values (in ㎛) were measured by using silicone replica method under stereomicroscope. Data were statistically analyzed by using 1-way ANOVA and Kruskal Wallis tests (P<.05). RESULTS. In terms of marginal adaptation, the measurements on the canine tooth indicated better performance with intraoral scanners than those in laboratory scanners, but there was no difference among intraoral scanners (P<.05). In the premolar tooth, PS had the lowest marginal (86.9 ± 19.2 ㎛) and axial (92.4 ± 14.8 ㎛), and T4 had the lowest axio-occlusal (89.4 ± 15.6 ㎛) and occlusal (89.1 ± 13.9 ㎛) discrepancy value. In both canine and premolar teeth, the D900L was found to be the most marginally and internally inconsistent scanner. CONCLUSION. Within the limits of the study, marginal and internal discrepancy values were generally lower in intraoral scanners than in laboratory scanners. Marginal discrepancy values of scanners were clinically acceptable (< 120 ㎛), except D900L.

Spectrophotometer를 이용한 지르코니아 코어의 두께 및 도재축성법에 따른 색조의 변화에 대한 연구 (The study on the color change according to zirconia core thickness, and build-up technique using spectrophotometer)

  • 허성윤;김재홍;손호정
    • 대한치과기공학회지
    • /
    • 제33권4호
    • /
    • pp.313-321
    • /
    • 2011
  • Purpose: The purpose of this study was to compare color parameters of different fabrication method of Lava ceram powder, Lava DVS blocks, IPS e.max ceram and IPS e.max zirpress. Methods: The three available shades(A1, A2, A3.5) of Lava & Kavo zirconia blocks were examined. For each of three colors, three different thickness were tested, 5 times of measurement frequency. The measurements were made using a spectrophotometer equipped with an integrating sphere using the CIE $L^*$, $a^*$, $b^*$ colorimetric system. Results: Lava build-up group and Lava DVS group showed clinically perceived color difference, on the other hand IPS e.max build-up group and IPS e.max zirpress group did not show clinically perceived color difference to shade allowed on core. When the thickness of porcelain veneer increased from Lava and IPS e.max groups, color differences(${\Delta}E$) were decreased. Conclusion: All-ceramic system has color characteristics that clinicians have to consider when selecting materials. Also, manufacturers of different porcelain systems must make every effort to achieve color reproducibility.

Fe(NO3)3 수용액의 농도와 침지시간에 따른 지르코니아의 색상 및 특성 변화 (The change of color and physical properties of zirconia according to the variation of concentration and dipping time of Fe(NO3)3solution)

  • 서정일;박원욱;고재숙
    • 대한치과기공학회지
    • /
    • 제38권4호
    • /
    • pp.281-290
    • /
    • 2016
  • Purpose: The increased aesthetic requirements and demands of patients have resulted in the developments of coloring liquid for zirconia. Methods: In this study, zirconia block was dipped into $Fe(NO_3)_3$solution, which showed a color and then concentration of $Fe(NO_3)_3$and zirconia's color and physical properties depending on the dipping time were observed and compared with exclusive coloring solutions. As the result, the following conclusions were obtained. Results: When compared with the specimens that were colored using exclusive solutions, $L^*$ value rose overall depending on the concentration of $Fe(NO_3)_3$and $a^*$ value was red in the form of (+) in all the specimens. Also, $b^*$ value was in the form of (+) at 0.5 to $1{\ss}fl$, but was in the form of (-) at 1.5 to $2{\ss}fl$. The dipping time did not highly influence $L^*$ value, but $a^*$ value and $b^*$ value were directly opposite to the specimens, which were not colored, except the sample that was dipped for only 2 seconds. When compared with exclusive coloring solutions, $Fe(NO_3)_3$had the most similar color at 0.5 to $1{\ss}fl$ and the longer the coloring time, the higher the rate of color change became. In relation to the density change depending on the addition of $Fe(NO_3)_3$, there was the lowest density at $2{\ss}fl$ and the density was increased in the specimens that were not colored. Conclusion: These results show that $Fe(NO_3)_3$solution can be used to make colored zirconia. It is expected that newly made colored zirconia can be used in clinical practice because the colored zirconia not only possesses the mechanical properties that all ceramic core material should have but also was biocompatible to a living cells.

Flexural strengths of implant-supported zirconia based bridges in posterior regions

  • Rismanchian, Mansour;Shafiei, Soufia;Nourbakhshian, Farzaneh;Davoudi, Amin
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.346-350
    • /
    • 2014
  • PURPOSE. Impact forces in implant supported FDP (fixed dental prosthesis) are higher than that of tooth supported FDPs and the compositions used in frameworks also has a paramount role for biomechanical reasons. The aim of this study was to evaluate the flexural strength of two different zirconia frameworks. MATERIALS AND METHODS. Two implant abutments with 3.8 mm and 4.5 mm platform were used as premolar and molar. They were mounted vertically in an acrylic resin block. A model with steel retainers and removable abutments was fabricated by milling machine; and 10 FDP frameworks were fabricated for each Biodenta and Cercon systems. All samples were thermo-cycled for 2000 times in $5-55^{\circ}C$ temperature and embedded in $37^{\circ}C$ artificial saliva for one week. The flexural test was done by a rod with 2 mm ending diameter which was applied to the multi-electromechanical machine. The force was inserted until observing fracture. The collected data were analyzed with SPSS software ver.15, using Weibull modulus and independent t-test with the level of significance at ${\alpha}=.05$. RESULTS. The mean load bearing capacity values were higher in Biodenta but with no significant differences (P>.05). The Biodenta frameworks showed higher load bearing capacity ($F_0=1700$) than Cercon frameworks ($F_0=1520$) but the reliability (m) was higher in Cercon (m=7.5). CONCLUSION. There was no significant difference between flexural strengths of both zirconia based framework systems; and both Biodenta and Cercon systems are capable to withstand biting force (even parafunctions) in posterior implant-supported bridges with no significant differences.

새로운 CAD/CAM 블록의사용 : PICN and RNC (Novel CAD/CAM hybrid blocks: PICN and RNC)

  • 고경호
    • 대한치과의사협회지
    • /
    • 제56권3호
    • /
    • pp.167-174
    • /
    • 2018
  • The development of dental materials has widened the scope of materials by changes in processing methods. CAD/CAM processing enables the use of zirconia as a dental material. Recent esthetic materials development has been made. For aesthetic purposes, a block for CAD/CAM processing by mixing polymer and ceramic materials are fabricated. However there is no guideline of how these materials should be used in actual clinical practice. Mechanical properties, wear and clinical studies were reviewed.

  • PDF

착색액 침지 횟수와 최종 소결 온도가 지르코니아 세라믹의 굴곡강도에 미치는 영향 (The effects of the number of times dipped in coloring liquid and final sintering temperature on flexural strength of zirconia ceramics: Zirconia ceramics having improved transparency)

  • 공문천;김갑진;권태엽;홍민호
    • 대한치과재료학회지
    • /
    • 제44권2호
    • /
    • pp.171-178
    • /
    • 2017
  • 본 연구의 목적은 착색액 침지 횟수와 소결온도가 지르코니아 세라믹의 굴곡강도에 미치는 영향을 조사하였다. 본 연구에서는 투명도가 향상된 지르코니아 블록을 이용하여 $25mm{\times}2mm{\times}1.5mm$ 크기의 시편을 제작하였다. 제작된 지르코니아세라믹 시편을 0, 2, 그리고 4회로 구분하여 착색 용액에 침지하여 색조를 부여하였다. 그 다음, $1,450^{\circ}C$$1,600^{\circ}C$로 최종 소결 후, 만능시험기를 이용해서 굴곡강도를 측정하였다 (전체 6개 그룹, 각 그룹 n=10). 미세조직 관찰은 전방전계주사현미경(SEM)을 사용하였고, 실험을 통해 획득된 자료는 Two-away ANOVA를 이용하여 분석하였다. 굴곡강도 분석결과 EKL2 군에서 $762.3{\pm}42.3MPa$로 가장 높은 값을 보였다. 대조적으로, EKH4 군에서는 $516.4{\pm}77.1MPa$로 가장 낮은 값을 나타내었다. Two-way ANOVA의 결과에 따르면, 굴곡강도는 소결온도와 착색액 침지 횟수 사이에 상호 작용이 없는 것으로 나타났다($R^2=0.737$). 또한, 굴곡강도 결과 값에 관련하여, 소결온도에서 통계학적 유의차 가 나타났다 (P<0.001). 투명도가 향상된 지르코니아 세라믹의 굴곡강도는 소결온도에 의존하는 것으로 나타났다. 착색액 침지 횟수는 투명도가 향상된 지르코니아 세라믹의 굴곡강도에 영향을 미치지 않았다.