• 제목/요약/키워드: zinc-air battery

검색결과 31건 처리시간 0.031초

연 취급 노동자의 연 폭로 수준 및 혈중 Zinc Protoporphyrin 농도 (Level of Lead in Air and Blood Zinc Protoporphyrin of Workers in Lead Plants)

  • 김창영
    • 한국환경보건학회지
    • /
    • 제17권1호
    • /
    • pp.95-103
    • /
    • 1991
  • For the purpose of estimating the working environment and the relationship between the airborne lead concentration and the ZPP level in the whole blood of the workers, the airborne lead concentrations and the ZPP level were measured at the 26 plants which deal with lead, from October 5 to November 5 in 1988. Analysis of the airborne lead concentration was performed by NIOSH Method 7082, and the ZPP level was measured by a hematofluorometer. The following results are concluded. 1. The average airborne lead concentration of the lead battery manufactures is 0.025mg/m$^{3}$ and that of the secondary lead smelters is 0.023mg/m$^{3}$. There were no significant differences between industry (p>0.1) 2. At the lead battery manufacture, the process of lead powder production showed the highest concentration of 0.034mg/m$^{3}$ but there were no significant differences among the processes (p>0.1). At the secondary lead smelter, the process of dismantling waste batteries showed the highest concentration 0.141mg/m$^{3}$, and there were very significant differences among the processes (p<0.005). 3. The ZPP level in the whole blood showed significant differences between industry (p<0.10). The average ZPP level of the lead battery manufactures is 133.0 + 106.3 $\mu$g/100ml and that of the secondary lead smelters is 149.6 + 110.9 $\mu$g/100ml. 4. The correlation coefficients between the airborne lead concantration and ZPP level were 0. 426 (p<0.001) for the lead battery manufactures and 0.484 (p<0.001) for the secondary lead smelters. The correlation coefficients between the work duration (in months) and the ZPP level were 0.238 (p<0.001) for the lead battery mannfactures and 0.075 (p>0.10) for the secondary lead smelters. 5. The linear regression equation, with the airborne lead concentration as an independent variable and the ZPP level as a dependent variable, is Y=96.84+1300.34X (r=0.448, p<0.001) for the 26 plants which deal with lead. The linear regression equation, with the work duration(in months) as an independent variable and the ZPP level as a dependent variable, is Y=127.28 +0.49X (r=0.162, p<0.05). 6. The correlation coefficients between the amount of inhaled lead and ZPP level were 0.349 (p < 0.001) for the lead battery manufactures and 0.318(p<0.001) for the secondary lead smeltes. The linear regression equation for the 26 plants surveyed, with the amount of inhaled lead as an independent variable and ZPP level as a dependent variable, is Y=123.63+18.82X (r=0. 335, p<0.001).

  • PDF

산성용액에서 전해액 조성에 따른 아연공기 이차전지의 성능변화 (Characterization for Performance of Zn-Air Recharegeable Batteries on Different Composition in Acidic Electrolyte)

  • 대관하;노립신;심중표;이홍기
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.401-409
    • /
    • 2021
  • The combination of different concentrations of ZnSO4 in acidic solution as electrolyte in Zn-air batteries was investigated by Zn symmetrical cell test, half-cell and full cell tests. Using 1 M ZnSO4 + 0.05 M H2SO4 as electrolyte and MnO2 as air cathode catalyst with Zn foil anode, this combination had a satisfactory performance with balance of electrochemical activity and stability. Its electrochemical activity was matched to or even better than the PtRu catalyst in different current density. And its cycle life was improved (more than 100 cycles stable) by suppressing the growth of zinc dendrites on anode obviously. This electrolyte overcame the shortcomings of alkaline electrolyte that are easy to react with CO2 in the air, severely growth of Zn dendrites caused by uneven plating/stripping of Zn.

수용액중 아연 덴드라이트의 성장 반응에 미치는 전해질 농도의 영향 (Effects of Electrolyte Concentration on Growth of Dendritic Zinc in Aqueous Solutions)

  • 신경희;정규남;윤수근;연순화;심준목;전재덕;진창수;김양수;박경수;정순기
    • 한국수소및신에너지학회논문집
    • /
    • 제23권4호
    • /
    • pp.390-396
    • /
    • 2012
  • In order to understand the nature of dendritic zinc growth, electrochemical zinc redox reaction on nickel plate was investigated in aqueous solutions containing different concentrations, 0.2, 0.1 and 0.02 $mol{\cdot}dm^{-3}$ (M), of zinc sulfate ($ZnSO_4$) or zinc chloride ($ZnCl_2$). Zinc ion was efficiently reduced and oxidized on nickel in the high-concentration (0.2 M) solution, whereas relatively poor efficiency was obtained from the other low-concentration solutions (0,1 and 0.02 M). Cyclic voltammetry (CV) analysis revealed that the 0.2 M electrolyte solution decomposes at more positive potentials than the 0.1 and the 0.02 M solutions. These results suggested that the concentration of electrolyte solution and anion would be an important factor that suppresses the reaction of the zinc dendrite formation. Scanning Electron Microscopy (SEM) data revealed that the shape of dendritic zinc and its growing behavior were also influenced by electrolyte concentration.

Polytetrafluoroethylene막을 통한 기체의 투과 및 확산 (Permeation and diffusion of gases through polytetrafluoroethylene membrane)

  • 김형민;김남인;이우태
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1994년도 추계 총회 및 학술발표회
    • /
    • pp.34-35
    • /
    • 1994
  • 기체혼합물의 분리및 정제기술은 에너지 절약의 관점과 새로운 기능성 고분자의 개발로 고분자막에 의한 분리법이 관심을 끌게되었다. 공기로부터 산소부화, 방사성 크세논 및 크립론의 제거, 제련소 폐가스증의 수소분리, 천연가스로부터 헬륨의 회수분야등은 실제로 산업적으로 실용화되고 있다. 그러나 고분자막은 일반적으로 투과성과 선택성이 서로 상반되는 경향을 나타내므로, 투과성과 분리성이 좋은 기능성 고분자막의 개발에 다양한 연구가 필요로 하고있다. 본 연구에서 사용한 PTFE(polytetrafluoroethylene)는 결정성 고분자로서 넓은 온도범위에서 낮은 마찰계수, 우수한 전기적 절연특성, 강한 Carbon-fluorine 겹합에 기인한 높은 열적 안정성, 화확적 불활성때문에 공업용 고분자 재료로서 독특한 위치를 차지하고 있다. 최근에 미국과 일본을 주축으로 상용화딘 공기전지(Zinc-air battery)는 PTFE막의 뛰어난 소수성과 화학적 저항성으로 수은 전지의 대체품으로 주목받고 있는데, 장기 방전시 성능 저하가 따르므로 막을 통한 산소투과성을 방전에 필요한 최소값으로 감소시키는 것이 중요한 과제가 되고있다.

  • PDF

포스트 리튬 이차전지 기술 동향 (Technology Trends in Post-Lithium Secondary Batteries)

  • 최윤호;정형석
    • 전자통신동향분석
    • /
    • 제38권6호
    • /
    • pp.128-136
    • /
    • 2023
  • Lithium accounts for only 0.0017% of the earth crust, and it is produced in geographically limited regions such as South America, the United States, and China. Since the first half of 2017, the price of lithium has been continuously increasing, and with the rapid adoption of electric vehicles, lithium resources are expected to be depleted in the near future. In addition, economic blocs worldwide face intensifying scenarios such as competition for technological supremacy and protectionism of domestic industries. Consequently, Korea is deepening its dependence on China for core materials and is vulnerable to the influence of the United States Inflation Reduction Act. We analyze post-lithium secondary battery technologies that rely on more earth-abundant elements to replace lithium, whose production is limited to specific regions. Specifically, we focus on the technological status and issues of sodium-ion, zinc-air, and redox-flow batteries. In addition, research trends in post-lithium secondary batteries are examined. Post-lithium secondary batteries seem promising for large-capacity energy storage systems while reducing the costs of raw materials compared with existing lithium-based technologies.

아연공기전지용 Pr1-x (Sr, Ca)xCoO3 양극촉매 제조 및 전기화학적 특성 (Preparation and Electrochemical Properties of Pr1-x (Sr, Ca)xCoO3 Cathode Materials for Zinc Air Batteries)

  • 허상훈;엄승욱;김현수
    • 전기화학회지
    • /
    • 제12권4호
    • /
    • pp.342-348
    • /
    • 2009
  • 아연공기이차전지는 고에너지밀도형이고 환경친화적이며 낮은 제조단가와 수용액계의 전해질 사용으로 다른 종류의 전지에 비해 매우 안전한 특성을 가진다. 하지만, 고출력 방전에 취약한 단점이 있으며 수용액에서 산소발생 및 환원반응은 매우 높은 과전압 하에서 일어나 전지효율의 감소 및 수명단축의 결과를 가져온다. 따라서 충 방전이 개시되면서 초기 OCV로부터 전압강하를 최소화 시키는 것이 성능 개선의 관건인데 이는 고성능의 촉매개발로 해결해야 한다. 본 연구에서는구연산법을 이용하여 $Pr_{1-x}(Sr,\;Ca)_x\;CoO_3$분말을 합성하고 각 분말들의 물성을 XRD, SEM, TGA 등을 이용하여 측정하고, 이를 이용한 양극의 환원 및 산화분극과 순환전압전류 등의 전기 화학적 특성을 평가하여 기존에 연구했던 $La_{1-x}Sr_xCoO_3$, $La_{1-x}CaxCoO_3$ 등의 촉매 성능보다 향상된 결과를 얻을 수있었다.

Development and Performance of a Hand-Held CZT Detector for In-Situ Measurements at the Emergency Response

  • Ji, Young-Yong;Chung, Kun Ho;Kim, Chang-Jong;Yoon, Jin;Lee, Wanno;Choi, Geun-Sik;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.87-91
    • /
    • 2016
  • Background: A hand-held detector for an emergency response was developed for nuclide identification and to estimate the information of the ambient dose rate in the scene of an accident as well as the radioactivity of the contaminants. Materials and Methods: To achieve this, the most suitable sensor was first selected as a cadmium zinc telluride (CZT) semiconductor and the signal processing unit from a sensor and the signal discrimination and storage unit were successfully manufactured on a printed circuit board. Results and Discussion: The performance of the developed signal processing unit was then evaluated to have an energy resolution of about 14 keV at 662 keV. The system control unit was also designed to operate the CZT detector, monitor the detector, battery, and interface status, and check and transmit the measured results of the ambient dose rate and radioactivity. In addition, a collimator, which can control the inner radius, and the airborne dust sampler, which consists of an air filter and charcoal filter, were developed and mounted to the developed CZT detector for the quick and efficient response of a nuclear accident. Conclusion: The hand-held CZT detector was developed to make the in-situ gamma-ray spectrometry and its performance was checked to have a good energy resolution. In addition, the collimator and the airborne dust sampler were developed and mounted to the developed CZT detector for a quick and efficient response to a nuclear accident.

자외선 및 블루영역 차단 화장품 응용을 위한 박막 판형 인공 칼라민 소재의 합성 및 특성 평가 연구 (Preparation and Characterization of Planar-type Artificial Calamine Powder with a High Aspect Ratio for the Application to Ultraviolet and Blue Band Protection Cosmetics)

  • 이정환;이건섭;조동현;홍다희;유재훈;곽지유;이희철
    • 대한화장품학회지
    • /
    • 제47권3호
    • /
    • pp.227-235
    • /
    • 2021
  • 자외선 및 블루영역 차단 기능을 갖는 화장품의 원료로 사용되기 위한 박막 판형의 ZnO 및 Fe2O3 성분을 포함하는 인공 칼라민 세라믹 분말 소재를 합성하였다. 20 : 1에서 50 : 1 범위의 높은 종횡비를 가지는 (0001)면의 판형 ZnO 세라믹 분말 소재는 아연공기전지로 전력 생산한 후에 회수한 전해질을 출발 물질로 하여 징크아세테이트와 소듐시트레이트 혼합 용액에서 중화반응을 통한 석출로 합성하였다. 아이언 클로라이드 용액의 첨가량을 증가시키는 방법으로 인공 칼라민 세라믹 분말 내의 Fe2O3 함량을 높일 수 있었으며, 이 경우 자외선뿐만 아니라 가시광선의 블루 영역을 일부 흡수하였다. 포타슘 아세테이트 용액을 첨가시킬 경우에는 Zn(OH)42- 음이온의 분해를 촉진하여 (0001) 면 위에 수직 방향으로 격벽 형태로 성장한 박막을 얻을 수 있었는데, 이 경우 자외선을 흡수할 수 있는 기회가 증가하면서 자외선 흡수율이 증가하였다. 아이언 클로라이드 용액과 포타슘 아세테이트 용액의 첨가량을 함께 조절하면 박막 판형의 인공 칼라민 세라믹 분말의 조성 및 형상을 최적화시킬 수 있어서 화장품 제형을 진행할 경우 블루영역의 광투과도가 크게 감소하였다.

축전지 제조업에서 입사 1년 미만 남자 사원들의 연 노출 지표치에 관한 연구 (A study on lead exposure indices of male workers exposed to lead less than 1 year in storage battery industries)

  • 황보영;김용배;리갑수;이성수;안규동;이병국;김정순
    • Journal of Preventive Medicine and Public Health
    • /
    • 제29권4호
    • /
    • pp.747-764
    • /
    • 1996
  • This study intended to obtain an useful information for health management of lead exposed workers and determine biological monitoring interval in early period of exposure by measuring the lead exposure indices and work duration in all male workers (n=433 persons) exposed less than 1 year in 6 storage battery industries and in 49 males who are not exposed to lead as control. The examined variables were blood lead concentration (PBB), Zinc-protoporphyrin concentration (ZPP), Hemoglobin (HB) and personal history; also measured lead concentration in air (PBA) in the workplace. According to the geometric mean of lead concentration in the air, the factories were grouped into three categories: A; When it is below $0.05mg/m^3$, B; When it is between 0.05 and $0.10mg/m^3$, and C; When it is above $0.10mg/m^3$. The results obtained were as follows: 1. The means of blood lead concentration (PBB), ZPP concentration and hemoglobin(HB) in all male workers exposed to lead less than 1 year in storage battery industries were $29.5{\pm}12.4{\mu}g/100ml,\;52.9{\pm}30.0{\mu}g/100ml\;and\;15.2{\pm}1.1\;gm/100ml$. 2. The means of blood lead concentration (PBB), ZPP concentration and hemoglobin(HB) in control group were $5.8{\pm}1.6{\mu}g/100ml,\;30.8{\pm}12.7{\mu}g/100ml\;and\;15.7{\pm}1.6{\mu}g/100ml$, being much lower than that of study group exposed to lead. 3. The means of blood lead concentration and ZPP concentration among group A were $21.9{\pm}7.6{\mu}g/100,\;41.4{\pm}12.6{\mu}g/100ml$ ; those of group B were $29.8{\pm}11.6{\mu}g/100,\;52.6{\pm}27.9{\mu}g/100ml$ ; those of group C were $37.2{\pm}13.5{\mu}g/100,\;66.3{\pm}40.7{\mu}g/100ml$. Significant differences were found among three factory group(P<0.01) that was classified by the geometric mean of lead concentration in the air, group A being the lowest. 4. The mean of blood lead concentration of workers who have different work duration (month) was as follows ; When the work duration was $1\sim2$ month, it was $24.1{\pm}12.4{\mu}g/100ml$, ; When the work duration was $3\sim4$ month, it was $29.2{\pm}13.4{\mu}g/100ml$ ; and it was $28.9\sim34.5{\mu}g/100ml$ for the workers who had longer work duration than other. Significant differences were found among work duration group(P<0.05). 5. The mean of ZPP concentration of workers who have different work duration (month) was as follows ; When the work duration was $1\sim2$ month, it was $40.6{\pm}18.0{\mu}g/100ml$, ; When the work duration was $3\sim4$ month, it was $53.4{\pm}38.4{\mu}g/100ml$ ; and it was $51.5\sim60.4{\mu}g/100ml$ for the workers who had longer work duration than other. Significant differences were found among work duration group(P<0.05). 6. Among total workers(433 person), 18.2% had PBB concentration higher than $40{\mu}g/100ml$ and 7.1% had ZPP concentration higher than $100{\mu}g/100ml$ ; In workers of factory group A, those were 0.9% and 0.0% ; In workers of factory group B, those were 17.1% and 6.9% ; In workers of factory group C, those were 39.4% and 15.4%. 7. The proportions of total workers(433 person) with blood lead concentration lower than $25{\mu}g/100ml$ and ZPP concentration lower than $50{\mu}g/100ml$ were 39.7% and 61.9%, respectively ; In workers of factory group A, those were 65.5% and 82.3% : In workers of factory group B, those were 36.1% and 60.2% ; In workers of factory group C, those were 19.2% and 43.3%. 8. Blood lead concentration (r=0.177, P<0.01), ZPP concentration (r=0.135, P<0.01), log ZPP (r=0.170, P<0.01) and hemoglobin (r=0.096, P<0.05) showed statistically significant correlation with work duration (month). ZPP concentration (r=0.612, P<0.01) and log ZPP (r=0.614, P<0.01) showed statistically significant correlation with blood lead concentration 9. The slopes of simple linear regression between work duration(month, independent variable) and blood lead concentration (dependent variable) in workplace with low air concentration of lead was less steeper than that of poor working condition with high geometric mean air concentration of lead. The study result indicates that new employees should be provided with biological monitoring including blood lead concentration test and education about personal hygiene and work place management within $3\sim4$ month.

  • PDF

연 노출 근로자들의 ALAD genotype에 따른 연 노출지표 및 증상과의 관련성 (Relationship on the lead exposure indices and symptoms by ALAD genotype in lead worker)

  • 안규동;이종천;조광성;김진호;이성수;이병국
    • 한국산업보건학회지
    • /
    • 제11권2호
    • /
    • pp.111-117
    • /
    • 2001
  • A cross-sectional study was performed to evaluate associations between lead biomarkers, lead-related symptoms, and ${\delta}$-aminolevulinic acid dehydratase (ALAD) genotype among 598 lead workers and 144 control office workers in storage battery industries, secondary smelting and litharge making industries. Lead inhibits the second enzymes, ALAD, in the heme synthesis pathway. ALAD gene, which codes for one of three isozymic proteins (termed ALAD1-1, ALAD1-2, and ALAD2-2), seems to modify the toxicokinetics of lead. The result as follows; The percents of total workers whose genotype of ALAD1-1 and ALAD1-2 were 88.4% and 11.6%, respectively. The zinc protoporphyrin in blood (ZPP) and ${\delta}$-aminolevulinic acid in urine (ALAU) of lead workers with ALAD1-2 were significantly lower than those of lead workers with ALAD1-1, but there were no significant difference between two genotype for blood lead, age, and work duration. The proportion of ALAD1-2 genotype in control office workers was 13.2%. The proportions of ALAD1-2 genotype of lead workers were 14.0%(their mean air lead level below $0.024mg/m^3$), 10.4%($0.025-0.049mg/m^3$), 11.8%($0.050-0.099mg/m^3$), and 9.4%(above $0.100mg/m^3$), respectively. In the logistic analysis of 15 lead related symptoms, 'arthralgia'(S7) symptom of ALAD1-2 was significantly lower (OR=0.481; 95% CI=0.248-0.932) than that of ALAD1-1, but 'feeling of irritation'(S11) of ALAD1-2 was significantly higher(OR=1.636; 95% CI=1.035-2.586) than that of ALAD1-1 after controlling possible confounder (blood lead, work duration, smoking and drinking habit).

  • PDF