• Title/Summary/Keyword: zeta potential of algae

Search Result 11, Processing Time 0.019 seconds

Effect of Zeta Potential of Clay and Algae Particles on Flotation Efficiency (점토와 조류입자의 제타전위가 부상분리 효율에 미치는 영향)

  • Choi, Do-Young;Kim, Seong-Jin;Jung, Heung-Jo;Lee, Se-Ill;Paik, Do-Hyeon;Lee, Jae-Wook;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.437-445
    • /
    • 2005
  • Zeta potential is a key parameter of double layer repulsion for individual particles and can usually be used to interpret the trend of coagulation efficiency. This study focused on the measurement of zeta potential of algae and clay under various experimental conditions including water characteristics (pure water, stream water, reservoir water) and coagulant dose (10~50 mg/L). Results showed that the variation of zeta potential was highly sensitive depending on the water characteristics and coagulation conditions. Zeta potential of two genera of algae (anabaena sp. and microcystis sp.) were changed highly with coagulant dosage, especially. On the basis of trajectory analysis, bubble-floc collision efficiency simulated in terms of zeta potential was fitted well with removal efficiency of chlorophyll-a from algae particles. It was found that the control of zeta potential was important for effective removal of algae particles.

Toxicity evaluation based on particle size, contact angle and zeta potential of SiO2 and Al2O3 on the growth of green algae

  • Karunakaran, Gopalu;Suriyaprabha, Rangaraj;Rajendran, Venkatachalam;Kannan, Narayanasamy
    • Advances in nano research
    • /
    • v.3 no.4
    • /
    • pp.243-255
    • /
    • 2015
  • In this investigation, ecotoxicity of nano and micro metal oxides, namely silica ($SiO_2$) and alumina ($Al_2O_3$), on the growth of green algae (Porphyridium aerugineum Geitler) is discussed. Effects of nano and micro particles on the growth, chlorophyll content and protein content of algae are analysed using standard protocols. Results indicate that $SiO_2$ nano and micro $SiO_2$ particles are non-toxic to P. aerugineum Geitler up to a concentration of 1000 mg/L. In addition, $Al_2O_3$ microparticles are less toxic to P. aerugineum Geitler, whereas $Al_2O_3$ nanoparticles are found to be highly toxic at 1000 mg/L. Moreover, $Al_2O_3$ nanoparticles decrease the growth, chlorophyll content, and protein content of tested algae. In addition, zeta potential and contact angle are also important in enhancing the toxicity of metal oxide nanoparticles in aquatic environment. This study highlights a new insight into toxicity evaluation of nanoparticles on beneficial aquatic organisms such as algae.

A Study on the Elimination of Microcystis sp. using Microbubble (미세기포를 이용한 Microcystis sp. 제거에 관한 연구)

  • Hyung, Sung-Hee;Lee, Kap-Du;Park, Sang-Won
    • Journal of Environmental Science International
    • /
    • v.25 no.3
    • /
    • pp.425-438
    • /
    • 2016
  • This study carried out zeta potential measurements of the Microcystis sp. under various solutions condition and investigated the characteristics of Microcystis sp. through the size control of microbubbles to eliminate algae that causes problems in aquatic ecosystems and human activities. DAF process was adopted and several coagulants were used to remove the Microcystis sp. CCD Camera was used to measure and analyze the size of microbubble, and fluorescent microscope was used to observe the particle, algae species and community. Zeta potential behavior of the algae was analyzed by using ELS-Z. Lab-scale and pilot-scale experiments were conducted to test flotation process. Polyaluminium chloride(PAC) coagulant was used, and the removal efficiency of the algae was assessed through Chlorophyll-a analysis. In the Lab-scale experiment, 2.2 ppm, 11 ppm, 22 ppm, and 44 ppm of polyaluminium chloride was injected to coagulate the algae. The coagulated algae was floated by the microbubble. The microbubbles in the experiments were generated at a air pressure of 450 ~ 550 kPa. The microbubble size was controlled in $36{\mu}m$, $100{\mu}m$, and $200{\mu}m$, respectively by using different diffuser. The results of lab-scale experiments on flotation plant indicated that the average removal rate was about 90% or above for 11 ppm, 22 ppm, and 44 ppm of polyaluminium chloride. On the other hand, in the pilot-scale experiment, the removal efficiency was in the range of 85% to 95% in all dose ranges of polyalumium chloride and aluminium sulfate coagulants.

Determination of Optimum Coagulant Dosage for Effective Water Treatement of Chyinyang Lake - The Effect of Coagulant Dosing on Removal of Algae- (진양호소수의 효과적인 정수처리를 위한 최적응집제 주입량 결정 -조류제거를 위한 응집제 주입효과-)

  • 이원규;조주식;이홍재;임영성;허종수
    • Journal of Environmental Science International
    • /
    • v.8 no.5
    • /
    • pp.625-631
    • /
    • 1999
  • This study was performed to determine the optimum coagulant dosing for effective treatment of raw water in Chinyang lake. Removal rates of algae and characteristics of the water according to coagulants dosage were investigated by treatment with Microcystis aeruginosa, which is a kind of blue-green algae, to the raw water below 5NTU. The coagulants dosage for maximum removal rate of algae were 30 mg/$\ell$ of Alum, 30 mg/$\ell$ of PAC and 10 mg/$\ell$ of PACS, respectively. The removal rate of algae in 30 mg/$\ell$ of PAC was highest as 85% compared with the other treatments. At the point of maximum removal rate of algae, the removal rates of turbidity were 34%, 66% and 22% in Alum, PAC and PACS, respectively. Residual Al was decreased depend upon decreasing turtidity in water by treatment of Alum or PAC, but decreased depend upon increasing turbidity in water by treatment of PACS. The removal rate of ${Mn}_{2+}$ in water was high in the order of Alum, PAC and PACS treatment. And ${Fe}_{2+}$ in water was not changed by treatemnt of these coagulants. Particle numbers distributions according to the particle size of suspended solids that were not precipitated at 8 min. of settling time after treatment of coagulants dosage for the maximum removal rate of algae were investigated. Most of the particle sizes were below 30 $\mu$m and particle numbers distributions below 10 $\mu$m were 64%, 56% and 66% by treatment of Alum, PAC and PACS, respectively. Zeta potential was in the range of -6.1~-9.7 mV at optimum coagulants dosage for algae removal.

  • PDF

DAF Technology for Various Kind of Plankton Removal from Eutrophic Lakes (부영양화 호소에서의 우점종 조류 제거를 위한 DAF 기술)

  • Kazuo, Taki;Yoriumi, Ishiyama;Doggo, Seog;Kim, Hag Su
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.247-253
    • /
    • 2004
  • Major species of Lake Deganuma has varied depending on the season. Namely, there are Micractinium pusillum, chlorella., Scenedesmus sp. shown up in spring season, Microcystis aeruginosa, Microcystis wesenbergii, Anabena spiroides in summer and autumn season and Cyclostephanos invisitatus, Diatoma in winter season in the Lake. As the number of plankton increased, the zeta potential on their surface of them decreased. For this reason, they were dispersed in the lake though the population increased. Zeta potential of M. aeruginosa showed -20mV when their outer size got smaller. As for coagulant dosing in DAF, large amount of coagulant was effective to get lots of sludge during water treatment.

Studies on the Flocculation of Algae with Metal Ions (금속이온에 의한 조류 응결에 관한 연구)

  • Park, Yeong Jae;Lee, Sang Soo;Cho, Hye Ryun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.8
    • /
    • pp.441-449
    • /
    • 2015
  • Studies on the flocculation of algae using various metal ions were carried out by measurements of optical density(OD) and zeta potential. Cyanobacteria were used as algaes. Flocculation efficiencies of cyanobacteria by an addition of metal ions were determined from OD values, and the effect of metal ions was greater in the order of $Al^{3+}$>$La^{3+}$>$Ho^{3+}$>$Fe^{2+}$>$Ca^{2+}$. Especially for trivalent metal ions, percentages of metal removed from cyanobacteria solutions on flocculation were measured, showing the same order as in flocculation efficiencies. Zeta potentials of cyanobacteria alone were measured with increasing the concentration, found to be all negative voltages, and were increased with increasing the concentration. The effect of pH on zeta potential of cyanobacteria solution was investigated. Below pH 5.5, the zeta potentials were steeply decreased with increasing pH, whereas in the range of $5.5{\leq}pH{\leq}10$ they were almost constant ($-46{\pm}1mV$) even with increasing pH. At a constant concentration of cyanobacteria ($A_{730}=0.25$), an increase in concentration of metal ions caused an increase in zeta potential of cyanobacteria solution, showing that the effect was greater in the order of $Al^{3+}$>$Ho^{3+}$>$La^{3+}{\gg}Mg^{2+}{\geq}Ca^{2+}{\gg}K^+$. At a constant metal concentration, zeta potentials were measured with increasing cyanobacteria concentration, showing that zeta potentials for $K^+$, $Mg^{2+}$ and $Ca^{2+}$ ions were negligibly changed, whereas those of $Ho^{3+}$ and $La^{3+}$ ions were decreased. Moreover, the effect of $Ho^{3+}$ ion on decreasing zeta potential was smaller than that of $La^{3+}$ ion. $Al^{3+}$ ions showed quite a different behavior that with increasing cyanobacteria concentration the zeta potentials increased and decreased thereafter. Hydrolysis of $Al^{3+}$ ions caused a difficulty to investigate coagulation or flocculation of cyanobacteria by measurement of zeta potential.

Fundamental Structure in Simultaneous Removal for Phytoplankton and Nutrient Salt in Lakes

  • SEKI, Tatsuhiro;ISHII, Yuuichi;ISHII, Toshio;TAKI, Kazuo
    • Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.220-225
    • /
    • 2009
  • The water quality in eutrophic lakes is affected by serious problems, such as abnormal increasing of Cyanobacteria. The purpose of this study was to investigate the possibility of a modified flotation system using a hybrid technique formed by chemical compounds and an electrostatic bridge. Therefore, experiments using the hybrid technique were performed to measure the zeta potential value on the phytoplankton surface and the removal efficiencies of phytoplankton, ammonia nitrogen, nitrate nitrogen and phosphoric acid. The results were as follows: Firstly, the zeta potential of M.aeruginosa was observed to approach charge neutralization due to adhesion of magnesium hydroxide precipitate on the phytoplankton surface in the pH range 10.5 to 11. Secondly, the concentration of chlorophyll-a decreased from about 150 to 20${\mu}g$g/L, with a maximum removal efficiency of 84% due to coagulation with pH values higher than 10. Thirdly, the N$H_4$-N concentration was observed to decrease from 0.62 to 0.54mg-N/L (13%), and the P$O_4$-P concentration, which is a limiting factor to the formation of algae blooms, decreased from 0.27 to 0.02mg-P/L (92%). These findings suggest that the modified flotation system can be applied for the purification of the raw water of numerous lakes containing high phytoplankton populations and elevated pH.

Adsorption-DAF Hybrid Process for the Simultaneous Removal of Algae and Organic Compounds (조류와 유기화합물의 동시제거를 위한 흡착 - DAF 복합공정)

  • Lee, Jae-Wook;Kwak, Dong-Heui;Choi, Seung-Phil;Jung, Heung-Joe
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.208-214
    • /
    • 2004
  • Dissolved air flotation (DAF) is an effective solid/liquid separation process for low density floc particles such as algal, color-alum and clay-alum flocs produced from low turbidity water. The removal of taste and odor-causing organics (2-mthylisoboneol and geosmin) originating from algae in drinking water is a local and worldwide concern. Although DAF has been effectively applied for the removal of suspended solid, its application for the treatment of dissolved organic carbon is very limited. In this study, a new hybrid system consisting of adsorption and DAF processes was introduced for the simultaneous removal of algae and taste and odor-causing organics. Powdered activated carbon (PAC) was used as an adsorbent. In this proposed system, the major concern of eliminating the spent PAC from the system was also addressed. It was found that zeta potential of algae and PAC was increased with coagulant dosage, and the removal efficiency in DAF was also enhanced up to 90~95% under the given experimental conditions. Based on this study, the hybrid process was found to be a promising technology for the simultaneous removal of algae and dissolved organic pollutants.

Water Quality Improvement System Using High Voltage Electric Field with Self-Generation System (자가 발전 시스템을 갖춘 고전압 전기장 수질개선 장치 개발)

  • Kang, Rae-Yun;Kang, Chul-Ung
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.84-89
    • /
    • 2015
  • The occurrence of algae caused by eutrophication of fresh water is a pollution source to destroy the aquatic environment. When the high voltage electric field is applied in the water, When a high voltage is applied to the electric field in the water, the algae can be broken the balance of cell membranes, and is dead. In this paper, we develop a water quality improvement system for generating an electric field having a higher energy than the zeta potential when a high voltage is applied to 4,000V. To ensure the mobility of the water quality improvement system, we designed the PV generation system using the optimal size technique that is based on the model of power lack ratio. By evaluating the output characteristics of the water quality improvement system, power generation characteristics of the PV generation system, and battery charging characteristics, we can show that the proposed system can be applicable to the water quality improvement system inhibiting the growth rate of the algae in the fresh water.

Experimental Application of DAF Hybrid Process to Remove Algae Particles for Conventional Water Treatment Processes and Change of Particle Characteristics (재래식 정수처리공정에서 조류입자 제거를 위한 DAF Hybrid 공정의 실험적 적용과 입자특성 변화)

  • Kwak, Dong-Heui;Yoo, Seung-Joon
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.516-520
    • /
    • 2008
  • There are many water treatment plants built over couple of decade ago in Korea. For most of those plants, they are required a countermeasure to cope with the deterioration caused from the superannuated facilities and the objective materials change of water treatment from inorganic particles like clay to algae particles due to eutrophication of lake and reservoir. A series of field and laboratory experiments was performed to investigate the feasibility of DAF hybrid process and the variation of particle characteristics by applying the additional DAF unit in conventional water treatment processes. On the basis of this experiments, the DAF was effective as an additive process in filtration basin (DAF-CSF combination processes). Using DAF-CSF combination process, the efficiency of stable particle removal can be achieved to produce the safe drinking water.