Browse > Article
http://dx.doi.org/10.9726/kspse.2015.19.2.084

Water Quality Improvement System Using High Voltage Electric Field with Self-Generation System  

Kang, Rae-Yun (Department of Mechatronics Engineering, Jeju National University)
Kang, Chul-Ung (Department of Mechatronics Engineering, Jeju National University)
Publication Information
Journal of Power System Engineering / v.19, no.2, 2015 , pp. 84-89 More about this Journal
Abstract
The occurrence of algae caused by eutrophication of fresh water is a pollution source to destroy the aquatic environment. When the high voltage electric field is applied in the water, When a high voltage is applied to the electric field in the water, the algae can be broken the balance of cell membranes, and is dead. In this paper, we develop a water quality improvement system for generating an electric field having a higher energy than the zeta potential when a high voltage is applied to 4,000V. To ensure the mobility of the water quality improvement system, we designed the PV generation system using the optimal size technique that is based on the model of power lack ratio. By evaluating the output characteristics of the water quality improvement system, power generation characteristics of the PV generation system, and battery charging characteristics, we can show that the proposed system can be applicable to the water quality improvement system inhibiting the growth rate of the algae in the fresh water.
Keywords
PV generation system; Optimal size design; High voltage electric field; Water quality improvement; Power lack ratio;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 K. S. Lee, K. S. Yoon, H. J. Kim, 2003, "A Program of Water Quality Management for Agricultural Reservoirs by Trophic State", Korean Journal of Environmental Agriculture, Vol. 22, No. 2, pp. 166-171   DOI   ScienceOn
2 M. K. Kang, G. W. Shin, H. S. Park, T. S. Kim, S. I. Lee, 2014, "The Performance for the Lanthanum-Zeolite Composite for the Eutrophication Prevention", Journal of the Korean Society of Environmental Engineers, Vol. 36, No. 3, pp. 203-213.
3 Y. Y. Kim, D. G. R, 2004, "Assessment of Wastewater Treatment Efficiency by Water Surface Contacting Cover System on Aeration Tank", Journal of the Korean Society of Environmental Engineers, Vol. 26, No. 4, pp. 417-421.
4 S. G. Kim, Y. G. Son, 2014, "Basic Study on the Design and Optimization of Sonoreactors for Sonochemical Water/Wastewater Treatment Processes", Journal of the Korean Wetlands Society, Vol. 16, No. 2, pp. 205-212.
5 S. M. Kang, S. J. Park, W. J. Kim, I. S. Chang, J. H. Lee, 2005, "Sterilization Experiment by High-Voltage Pulsed Electric Fielde", Journal of the Korean Institute of Electrical Engineers, Vol. 36, No. 3, pp. 206-213
6 H. K. Lee, M. H. So, 2000, "Effect of Impulse Voltage Waveform on Electrical Sterilization by High Voltage Pulsed Electric Fields", Journal of the Korean Society for Food Engineering, Vol. 4, No. 3, pp. 136-140.
7 I. H. Hwang, E. H. Kim, K. S. Ahn, 2011, "A Study on the Optimal Design of Large-Scale Photovoltaic Array", Journal of the Korean Solar Energy Society, Vol. 31, No. 1, pp. 8-14.   DOI
8 S. S. Jung, 2014, "A Study on the Benefit- Cost Analysis of Photovoltaic System in the Greenhome", Journal of the Korea Society for Power System Engineering, Vol. 18, No. 3, pp. 112-117.   DOI
9 K. H. Park, C. U. Kang, G. M. Lee, J. H. Kim, 2011, "Design of Optimal Combination for New and Renewable Hybrid Generation System", Communications in Computer and Information Science, Vol. 266 pp. 189-198.   DOI
10 I. Y. Kong, 2014, "A Study on the Load Forecasting Methods of Peak Electricity Demand Controller", Institute of Embedded Engineering of Korea, Vol. 16, No. 2, pp. 205-212.