• Title/Summary/Keyword: zero-energy

Search Result 1,178, Processing Time 0.028 seconds

The thermal cycle degration of MEA in PEMFC under cold start condition (냉시동 환경에서 thermal cycle이 FEMFC의 MEA 열화에 미치는 영향)

  • Rhee, Jun-Kee;Seo, Dong-Ho;Jeon, Yu-Kwon;Shul, Yong-Gun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.412-414
    • /
    • 2009
  • In recent times, starting up polymer electrolyte membrane fuel cells(PEMFC) in sub-zero condition is a great challenge of fuel cell electric vehicle(FCEV). The water produced in a cathode during PEMFCs operate. The water changes into the form of solid/ice in sub-zero temperatures and this makes trouble in PEMFC cells. Voltage of PEMFC drops and cold startup is failed. This paper describes an experimental study on the effect of thermal cycle to degradation of MEA in PEMFC.

  • PDF

Effective Compensation Method of Power Factor at Induction Load Using MERS(MAGNETIC ENERGY RECOVERY SWITCH) (단상유도성 부하와 직렬 연결된 MERS 효과검증)

  • Lee, Dong-Geun;Choi, Dong-Uk;Ko, Kwang-Cheo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2197-2198
    • /
    • 2006
  • 본 논문은 역률개선 효과가 있는 MERS(Magnetic Enery recovery switch)를 사용하여 에너지 효율에서의 결과를 입증하고자 한다. 전원과 유도성부하에 직렬 연결된 MERS는 Full Bridge와 비슷한 구성으로 전력용 MOSFET(or IGBT) SWITCH 4개와 전해 DC콘덴서 1개로 구성되어진다. MERS의 콘덴서는 부하와 콘덴서의 리액턴스, $X_C<X_L$을 만족하는 콘덴서의 용량을 선택하고 콘덴서에 충전된 전압에 의해 부하의 유도계수를 보상하여 역률을 1로 추종하며 개선된다. 이때 스위치는 전원 전압에 대해 zero-voltage switching 과 zero-current switching을 하게 된다. 만약 부하가 변하더라도 $X_C<X_L$을 만족한다면 자동적으로 역률은 1에 맞추어지게 된다

  • PDF

An Isolated Soft-Switching Bidirectional Buck-Boost Inverter for Fuel Cell Applications

  • Zhang, Lianghua;Yang, Xu;Chen, Wenjie;Yao, Xiaofeng
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.235-244
    • /
    • 2010
  • This paper presents a new isolated soft-switching bidirectional buck-boost inverter for fuel cell applications. The buck-boost inverter combines an isolated DC-DC converter with a conventional inverter to implement buck-boost DC-DC and DC-AC conversion. The main switches achieve zero voltage switching and zero current switching by using a novel synchronous switching SVPWM and the volume of the transformer in the forward and fly-back mode is also minimized. This inverter is suitable for wide input voltage applications due to its high efficiency under all conditions. An active clamping circuit reduces the switch's spike voltage and regenerates the energy stored in the leakage inductance of the transformer; therefore, the overall efficiency is improved. This paper presents the operating principle, a theoretical analysis and design guidelines. Simulation and experimental results have validated the characteristics of the buck-boost inverter.

The Analysis and Control of Dynamic Voltage Restorer with Zero Sequence (영상 성분을 고려한 배전 계통용 DVR 해석 및 제어)

  • Park, Sang-Young;Chung, Il-Yop;Moon, Seung-Il;Park, Jeong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.220-222
    • /
    • 2000
  • The propose of Dynamic Voltage Restorer(DVR) is the Power Quality controller of very short term (under 10 cycle). In this paper, we propose a model of distribution for zero sequence analysis and DVR for compensation. With EMTDC/PSCAD simulation, we can verify our method and problems of existing method. A new energy optimizing method is also investigation.

  • PDF

A comparative study between French schwa and Korean [i] - An experimental phonetic and phonological perspective -

  • Lee, Eun-Yung;Kim, Seon-Jung
    • Speech Sciences
    • /
    • v.7 no.1
    • /
    • pp.171-186
    • /
    • 2000
  • The aim of this paper is to investigate the acoustic characteristics of the French vowel [e] and Korean [i] and to seek a way of understanding them from a phonological point of view. These two vowels have similar distributional properties, i.e. they alternate with zero in some contexts. Therefore, in both languages, they are not found when immediately followed by a nucleus with phonetic content and in word-final positions. We firstly compare the two vowels by measuring the actual frequencies of the formants, pitch and energy using CSL. We also consider whether the realisation of the two vowels is affected by the speed of speech sounds. In order to show that realisation of the two vowels in both languages is not arbitrary, rather predicted, we will introduce the notion of proper government, proposed and developed by Kaye (1987, 1990) and Charette (1991).

  • PDF

The Effect of Cattle Slurry on the Forage Yield and Grassland Ecosystem (목초생산성과 초지 생태계에 미치는 액상분뇨의 시용효과)

  • ;H. Jacob
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.17 no.1
    • /
    • pp.35-42
    • /
    • 1997
  • Many farmers apply cattle slurry on grassland, often in excess of crop N requirements, resulting in groundwater contamination. Our research objective was the development of grassland management systems that reduce undesirable sideeffects on other compartment of the ecosystem. Field experiment was conducted during 1991~1993 on sandy loam soil at AllgZiu south western Germany. Different sets of conditions were tested such as : zero fertilization, reduced sluny application$(l20kg N ha^{-1}yr^{-1})$, intensive sluny application(conventional sluny application, $240kg N ha^{-1}yr^{-1}$). The plots of the reduced slurry application had no significant effect on dry matter yields, digestible dry matter and net energy of herbage. Dry matter yield of zero fertilization was significantly lower than that of usual slurry application, however the content of Ca and Mg in herbage tended to increase. We conclude that reduced sluny application can be applied on grassland without adverse effects on dry matter production and quality of herbage.

  • PDF

Effects of Thermal-Carrier Heat Conduction upon the Carrier Transport and the Drain Current Characteristics of Submicron GaAs MESFETs

  • Jyegal, Jang
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 1997.11a
    • /
    • pp.451-462
    • /
    • 1997
  • A 2-dimensional numerical analysis is presented for thermal-electron heat conduction effects upon the electron transport and the drain current-voltage characteristics of submicron GaAs MESFETs, based on the use of a nonstationary hydrodynamic transport model. It is shown that for submicron GaAs MESFETs, electron heat conduction effects are significant on their internal electronic properties and also drain current-voltage characteristics. Due to electron heat conduction effects, the electron energy is greatly one-djmensionalized over the entire device region. Also, the drain current decreases continuously with increasing thermal conductivity in the saturation region of large drain voltages above 1 V. However, the opposite trend is observed in the linear region of small drain voltages below 1 V. Accordingly, for a large thermal conductivity, negative differential resistance drain current characteristics are observed with a pronounced peak of current at the drain voltage of 1 V. On the contrary, for zero thermal conductivity, a Gunn oscillation characteristic is observed at drain voltages above 2 V under a zero gate bias condition.

  • PDF

Effective Compensation Method of Power Factor at Induction Load Using MERS(MAGNETIC ENERGY RECOVERY SWITCH) (단상유도성 부하와 직렬 연결된 MERS 효과검증)

  • Lee, Dong-Geun;Choi, Dong-Uk;Kol, Kwang-Cheo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1231-1232
    • /
    • 2006
  • 본 논문은 역률개선 효과가 있는 MERS(Magnetic Enery recovery switch)를 사용하여 에너지 효율에서의 결과를 입증하고자 한다. 전원과 유도성부하에 직렬 연결된 MERS는 Full Bridge와 비슷한 구성으로 전력용 MOSFET(or IGBT) SWITCH 4개와 전해 DC콘덴서 1개로 구성되어진다. MERS의 콘덴서는 부하와 콘덴서의 리액턴스, $X_C<X_L$을 만족하는 콘덴서의 용량을 선택하고 콘덴서에 충전된 전압에 의해 부하의 유도계수를 보상하여 역률을 1로 추종하며 개선된다. 이때 스위치는 전원 전압에 대해 zero-voltage switching 과 zero-current switching을 하게 된다. 만약 부하가 변하더라도 $X_C<X_L$을 만족한다면 자동적으로 역률은 1에 맞추어지게 된다.

  • PDF

A Korean Speech Recognition Using Fuzzy Rule Base (Fuzzy Rule Base를 이용한 한국어 연속 음성인식)

  • Song, Jeong-Young
    • The Journal of Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.13-21
    • /
    • 1997
  • This paper describes how to represent varations of feature parameters to improve recognition of continuous speech. For speech recognition, feature parameters, which are formant frequencies, pitches, logarithmic energies and zero crossing retes are used in general. But, their values and variations depend on speakers, for example disparities between man and woman, and on their age. It is difficult to decide a priority the value of the variation width. Hence, we try to represent this variation by introducing fuzziness and recognize a continuous speech by fuzzy inference using fuzzy production rules.

  • PDF

A Finite Element Solution to the Group Diffusion Problems with Albedo-Type Boundary Conditions (Albedo형 경계조건을 가진 다군확산문제에 대한 유한요소해)

  • Kun Joong Yoo;Chang Hyo Kim;Chang Hyun Chung
    • Nuclear Engineering and Technology
    • /
    • v.14 no.4
    • /
    • pp.178-185
    • /
    • 1982
  • Albedo-type boundary condition is incorporated into the finite element formulation of the cubic Hermite polynomials for the two-dimensional solution of the two-group diffusion problem. Two modifications are introduced with respect to the conventional expression for the weak form of the group diffusion equation with the zero flux or zero current boundary condition and the cubic element functions over the boundary nodes. The finite element formulations obtained from those modifications are tested with the two-dimensional ZION problem. The numerical effectiveness of the modifications are examined.

  • PDF