Energy Performance Evaluation of A Primary School Building for Zero Energy School (제로에너지 스쿨을 위한 초등 교육시설의 에너지 성능평가)

  • Yoon, Jong-Ho;Shin, U-Cheul;Cho, Jin-Il;Park, Jae-Wan;Kim, Hyo-Jung;Lee, Chul-Sung
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.121-126
    • /
    • 2009
  • This study analyzed the standard school's energy usage and patterns as the zero-energy goal of primary school building, and proposed the energy reduction process of school building using energy analysis computing simulation tool. As a analysis simulation tool, Visual DOE 4.0 is used. For analysis of actual energy usage, selected primary school that is standard in the nation's energy consumption. Standard of the school's energy consumption analysis were devided into electric and gas energy. Input parameters of the simulation program based on the literature material and field survey material. after, but it was calibrated to comparison with the standard school's energy consumption. Finally, its energy usage analyzed by component and made the priority order of energy saving. Applied energy saving technologies are envelopment insulation, high efficiency lighting, high performance HAVC system and used active equipment system of solar collector and photovoltaic generation for additional savings.

  • PDF

Study on the Recognition Analysis of Zero Energy House and Associated Policy Suggestion (에너지제로하우스 인식분석 및 정책 추진방향 제안에 관한 연구)

  • Lee, Chung-Kook;Lee, Jeong-Cheol;Kim, Sang-Su;Suh, Seung-Jik
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.16-26
    • /
    • 2012
  • The consultation with building energy experts working at domestic government-funded research institutes and enterprises on performance set, element technology, and policy for the realization of low-energy and the survey with construction workers on the relevance of climate change in building construction, government support policy, and methodologies for the construction of low-energy house were carried in the study. In addition the public element preference survey on the low-energy house and awareness research on the low-carbonization of building were carried and presented for the development of affordable low-energy house. There was a big difference in the recognition of building energy performance setting and setting for the construction cost to realize it between experts and ordinary citizens in the study. To fill this gap education and promotion of zero energy house and securing economic feasibility through the commercialization of element technology will be needed. The satisfaction in government's zero energy house policy was normally low. To improve this low satisfaction administrative and technical support are considered to be expanded. Common high cost of construction was the top priority to resolve the problem, and enhancing renewable energy grants, tax relief, and substantial cost support could be as detailed solutions.

Developing the Construction Guideline for ZEB Based on Air-tightness of Public Buildings in Korea (국내 비주거용 건물의 기밀성능 측정 결과를 통한 기밀 시공 가이드라인 개발)

  • Bae, Minjung;Choi, Gyeongseok
    • Land and Housing Review
    • /
    • v.11 no.3
    • /
    • pp.69-74
    • /
    • 2020
  • Since the design Standard for Energy Conservation in Building was implemented in 2008 for the first time, building elements such as window and door should satisfy the minimum criteria to apply for a building. Though its regulation does not cover the whole building yet, recent demand to reduce energy consumption in building sector grows rapidly year by year and also draws a lot of interest to ensure the whole building level. For example, a Zero energy building, one of low-energy buildings, requires a customized solution to resolve the air leakage issue to meet the standards in achieving the high level of air tightness. In this study, six non-residential buildings were tested by fan pressurization method to observe the air tightness of whole building to suggest the construction guideline for air tightness of low-energy building. Five out of six tested buildings showed 0.27 to 1.16 h-1 of number of air changes except one community center. These buildings were carefully constructed not only for building planning but also for parts where there was a concern of air leakage, thereby securing high levels of air-tightness. The construction skills were developed as a checklist to manage and supervise the construction site. It is our suggestion to use this checklist at construction sites for ZEB with the high level of air-tightness.

A Study on the Optimum Design of a Facade with Shading-type BIPV in Office Building (차양형 BIPV가 적용된 사무소 건물의 외피 최적 설계에 관한 연구)

  • Park, Se-Hyeon;Kang, Jun-Gu;Bang, Ah-Young;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 2015
  • Zero energy building is a self sufficient building that minimizes energy consumption through passive elements such as insulation, high performance window system and installing of high efficiency HVAC system and uses renewable energy sources. The Korea Government has been strengthening the building energy efficiency standard and code for zero energy building. The building energy performance is determined by the performance of building envelope. Therefore it is important to optimize facade design such as insulation, window properties and shading, that affect the heating and cooling loads. In particular, shading devices are necessary to reduce the cooling load in summer season. Meanwhile, BIPV shading system functions as a renewable energy technology applied in solar control facade system to reduce cooling load and produce electricity simultaneously. Therefore, when installing the BIPV shading system, the length of shadings and angle that affect the electricity production must be considered. This study focused on the facade design applied with BIPV shading system for maximizing energy saving of the selected standard building. The impact of changing insulation on roof and walls, window properties and length of BIPV shading device on energy performance of the building were investigated. In conclusion, energy consumption and electricity production were analyzed based on building energy simulations using energyplus 8.1 building simulation program and jEPlus+EA optimization tool.

An Analysis of the Self-reliance Rate by Element according to the Implementation of Zero Energy Certification System in School Facilities (학교시설 제로에너지인증제 시행에 따른 요소별 자립률 분석)

  • Meang, Joon-Ho;Kim, Sung-Joon;Lee, Seung-Min;Ko, Hyun-Su
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.20 no.1
    • /
    • pp.19-28
    • /
    • 2021
  • The Ministry of Land, Infrastructure, and Transport (MOLIT) is implementing a zero-energy building (ZEB) certification to save energy for the building section and to accelerate the achievement of national greenhouse gases reduction goals in accordance with a new climate regime. In 2014, the MOLIT announced a plan for early activation of the ZEB, and in January 2016, the "Green Buildings Construction Support Act" was revised and established. In addition, the plan was established to gradually spread zero-energy buildings from the public sector in 2020 to the private sector by 2025. Therefore, this study analyzed the self-sufficiency rate of each energy factor according to the implementation of the zero energy building certification of school facilities that belong to the public sector and are included in the mandatory zero energy buildings from 2020.

BIM-DRIVEN ENERGY ANALYSIS FOR ZERO NET ENERGY TEST HOME (ZNETH)

  • Yong K. Cho;Thaddaeus A. Bode;Sultan Alaskar
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.276-284
    • /
    • 2009
  • As an on-going research project, Zero Net Energy Test Home (ZNETH) project investigates effective approaches to achieve whole-house environmental and energy goals. The main research objectives are (1) to identify energy saving solutions for designs, materials, and construction methods for the ZNETH house and (2) to verify whether ZNETH house can produce more energy than the house uses by utilizing Building Information Modeling (BIM) and energy analysis tools. The initial project analysis is conducted using building information modeling (BIM) and energy analysis tools. The BIM-driven research approach incorporates architectural and construction engineering methods for improving whole-building performance while minimizing increases in overall building cost. This paper discusses about advantages/disadvantages of using BIM integrated energy analysis, related interoperability issues between BIM software and energy analysis software, and results of energy analysis for ZNETH. Although this investigation is in its early stage, several dramatic outcomes have already been observed. Utilizing BIM for energy analysis is an obvious benefit because of the ease by which the 3D model is transferred, and the speed that an energy model can be analyzed and interpreted to improve design. The research will continue to use the ZNETH project as a testing bed for the integration of sustainable design into the BIM process.

  • PDF

The Study of Optimal Operation Development of PV + ESS Active System for Zero Energy Building (제로에너지건물 구축을 위한 PV + ESS 액티브 시스템의 최적운영개발에 관한 연구)

  • Woo, Sung-Min;Moon, Jin-Chel;Ahn, Jong-Wook;Kim, Yong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.5
    • /
    • pp.53-63
    • /
    • 2019
  • This paper in order to efficiently operate zero energy buildings developed a methodology for optimal operation of PV + ESS active systems. This program consists of three steps. First step is PV optimal operation and second step is PV + ESS optimal operation. Third step is the analysis of the results by PV + ESS optimal operation. The optimal operation of PV + ESS was calculated by using Dynamic Programming (DP). Therefore, the optimal capacity and operating plan of PV + ESS in this study are calculated for electric load at building. This paper conducted case study to verify the validity of the developed algorithm. Also, the sensitivity analysis analyzed the effect of each variable on the optimal operation.

A Structural Consideration of Storage Interface Unit(SIU) for DC Distributed Net Zero Energy Building (Net Zero Energy Building의 효율 증대를 위한 DC배전의 에너지 저장장치 연계에 대한 연구)

  • Lee, S.W.;Seo, G.S.;Kim, H.J.;Cho, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.255-256
    • /
    • 2014
  • 최근 환경 문제가 사회적으로 대두됨에 따라 탄소배출권 제도에 대한 관심이 증대되면서 Net Zero Energy Building(NZEB)에 대한 관심 역시 커지고 있다. NZEB는 주로 태양광을 에너지원으로 이용하며, 더 효율적인 에너지 사용을 위해 에너지 저장장치(SIU)를 이용하는데 이 두 요소들은 DC전압을 출력으로 갖고 있으며, NZEB의 특성상 외부 AC그리드와 연결된 양방향 AC/DC컨버터의 사용량이 적기 때문에 건물 내 배전을 DC로 할 경우 더 효율적인 에너지 사용이 가능하다 본 논문은 기존 DC배전의 구조에 대해 살펴보고, 여기에 Renewable-Storage Connecting Unit(RSCU)을 더해 NZEB에서 에너지 사용의 효율성을 높이는 방법에 대해 연구하며, 또한 그 시스템 제어 방법에 대해 연구한다.

  • PDF

Retrofit of a UK residential property to achieve nearly zero energy building standard

  • Salem, Radwa;Bahadori-Jahromi, Ali;Mylona, Anastasia;Godfrey, Paulina;Cook, Darren
    • Advances in environmental research
    • /
    • v.7 no.1
    • /
    • pp.13-28
    • /
    • 2018
  • It is currently agreed upon that one of the major challenges in the construction industry is the energy efficiency of existing buildings. The World Meteorological Organisation (WMO) and United Nations (UN) have reported that the concentration of global atmospheric carbon dioxide has increased by an average of 50%, a record speed, from 2015 to 2016. The housing sector contributes to 45% of the UK's carbon emissions. To help tackle some of those issues the recast Energy Performance Building Directive (EBPD) has introduced Nearly Zero Energy Buildings (NZEBs) in the coming years (including buildings that will undergo refurbishment/renovations). This paper will explore the retrofitting of a UK residential dwelling using Thermal Analysis Simulation (TAS, EDSL) software by focusing on building fabric improvements and usage of on-site renewables. The CIBSE Test Reference Year (TRY) weather data has been selected to examine the performance of the building under current and future climate projections. The proposed design variables were finally implemented in the building altogether on TAS. The simulation results showed a reduction in the building's annual energy consumption of $122.64kWh/m^2$ (90.24%). The greatest savings after this were achieved for the annual reduction in carbon emissions and avoided emissions, which were 84.59% and $816.47kg/CO_2$, respectively.

Properties of lightweight matrix for inorganic insulation by cement types (시멘트 종류별 무기단열재용 경량 경화체의 특성)

  • Lim, Jeong-Jun;Pyeon, Su-Jeong;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.222-223
    • /
    • 2018
  • Recent government policies are increasing interest in zero-energy housing, a building that minimizes energy consumption (90% reduction). As the importance of building passive performance is emphasized, the role of insulation is increasing as a way to reduce indoor heat loss in order to minimize the use of cooling and heating energy. There are two main types of insulation. Organic insulation is widely used for various construction structures such as construction and industrial due to some merits such as the convenience of construction and construction cost. However, it has been pointed out as a main cause every time a fire accident occurs, Jecheon Sports Center', the fire damage of buildings caused by the use of organic insulation materials is expanding to social problems, so it is urgent to research on nonflammable inorganic insulation materials.