• 제목/요약/키워드: xy stage

검색결과 62건 처리시간 0.034초

평면 XY 공기정압 스테이지의 운동특성 분석 (Analysis on the motion characteristics of surface XY aerostatic stage)

  • 황주호;박천홍;이찬홍;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.359-362
    • /
    • 2003
  • The aerostatic stage. which is used in semiconductor process, is demanded higher velocity and more precise accuracy for higher productivity and integrated performance. So, in the case of XY stage, H type structure, which is designed two co-linear axis of guide-way, driving force in one surface, has advantage of velocity and accuracy compared to conventional tacked type XY stage. To analyze characteristics of H type aerostatic stage, H type aerostatic surface XY stage is made, which is driven by linear motor and detected position with precise optical linear scale. And, analyze characteristics of motion error, effect of angular motion on positioning accuracy error and effect of simultaneous control on variation of velocity.

  • PDF

원자현미경용 XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 원자 현미경의 측정 불확도 평가 (Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of measuring uncertainty of AFM system)

  • 김동민;이동연;권대갑
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1438-1441
    • /
    • 2005
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In this system, measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100um\times{100um}$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. Using this AFM system, 3um pitch specimen was measured. As a result, the uncertainty of total system has been evaluated.

  • PDF

평면 XY 스테이지용 공기베어링 안내면 오차 평가 (The evaluation of aerostatic guide-ways for planar XY stage)

  • 황주호;박천홍;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.141-142
    • /
    • 2006
  • This paper describes estimation method for 2D position error of planar XY stage from measured profiles of guide-ways. The XY stage usually moves along its guide ways. The motion error of each stage has effect on 2D position errors of XY stages and affected mainly by profiles of guide-ways. To estimate 2D position error and flatness of stages, the profiles of guide-ways were measured and used in motion error estimation.

  • PDF

XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 나노 정밀도의 원자 현미경 피치 측정 불확도 평가 (Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of pitch measuring uncertainty of a nano-accuracy AFM system)

  • 김동민;이동연;권대갑
    • 한국정밀공학회지
    • /
    • 제23권6호
    • /
    • pp.96-103
    • /
    • 2006
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In the long range (about several tens of ${\mu}m$), measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100{\mu}m\times100{\mu}m$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. As a result, XY scanner can have good performance. Using this AFM system, 3um pitch specimen was measured. The uncertainty of total system has been evaluated. X and Y direction performance is different. X-direction measuring performance is better. So to evaluate only ID pitch length, X-direction scanning is preferable. Its expanded uncertainty(k=2) is $\sqrt{(3.96)^2+(4.10\times10^{-5}{\times}p)^2}$ measured length in nm.

정밀 XY 스테이지 잔류진동 억제를 위한 실시간 입력성형에서의 이산화 효과에 관한 연구 (Discretization Effects of Real-Time Input Shaping in Residual Vibration Reduction for Precise XY Stage)

  • 박상원;최훈석;;홍성욱
    • 한국공작기계학회논문집
    • /
    • 제16권4호
    • /
    • pp.71-78
    • /
    • 2007
  • Input shaping is known to be a very effective tool for suppressing residual vibration without introducing any complicated sensors and feedback control. Real-time input shaping schemes necessitate a process such that the input command is discretized to deal with non-prescribed, real-time input. Thus parameters associated with input command discretization, such as time spacing and duration time, are unknowns which affect the performance of input shaping schemes, especially for small and fast XY stages. This paper investigates the effects of input command discretization parameters, such as time spacing and duration time, on the dynamic performance of XY stages subjected to real-time input shaping. An experimental system is developed which is equipped with an XY stage driven by servo-motors and real-time user command. Experiments are performed to investigate the dynamic performance of XY stage by changing these parameters and to yield a strategy to gain better performance.

박형 병렬구조 XYθ 정렬 스테이지 개발 (Development of Thin and Parallel XYθ Alignment Stage)

  • 강동배;안중환;손성민
    • 한국산학기술학회논문지
    • /
    • 제12권1호
    • /
    • pp.74-79
    • /
    • 2011
  • 정렬 시스템(Alignment System)은 다축의 스테이지를 이용하여 신속하게 물체를 정렬오차 범위 내로 위치결정시키는 역할을 한다. 본 연구에서는 병렬구조로 설계하여 두께가 얇고 높은 정밀도와 더불어 강성이 높은 XY${\theta}$ 정렬 스테이지를 개발하였다. 개발된 박형 병렬구조 XY${\theta}$정렬 스테이지는 직각도, 반복정밀도, 진직도 등의 3가지 측정항목에 대해 초정밀급을 달성하였으며 반복정밀도는 $1{\mu}m$미만이다. 비전시스템 및 정렬알고리즘을 활용한 정렬성능 평가에서는 정렬오차 ${\pm}6.25{\mu}m$를 달성하였다.

AFM 시스템을 위한 XYZ 3축 스테이지의 설계 (The design of XYZ 3-axis stage for AFM system)

  • 김동민;김기현;심종엽;권대갑;엄천일
    • 한국결정학회:학술대회논문집
    • /
    • 한국결정학회 2002년도 정기총회 및 추계학술연구발표회
    • /
    • pp.36-36
    • /
    • 2002
  • To Establish of standard technique of length measurent in 2D plane, we develope AFM system. The XY scanner scans the sample only in XY plane, while the Z scanner scans the specimen only in Z-direction. Cantilever tip is controlled to has constant height relative to speciman surface by feedback of PSPD signal. To acquire high accuracy, Z-axis measuring sensor will be added.(COXI or others). In this paper we design XYZ stage suitable for this AEM system. For XY stage, single module parallel-kinnematic flexure stage is used which has high orthogonality and minimum out-of-plane motion. To obtain best performance optimal design is performed. For XY stage, to be robust about parasitic motion optimal design of maximizing Z and tilt stiffness is performed under the constraint of motion range and stage size. And for Z stage, optimal design of maximizing 1st resonant frequency is performed. Because if resonant frequency is get higher, scan speed is improved. So it makes reduce the error by sensor drift. Resultly XYZ stage each have 1st natural frequency of 115㎐, 201㎐, 2.66㎑ and range 109㎛, 110㎛, 12㎛.

  • PDF

Estimation of 2D Position and Flatness Errors for a Planar XY Stage Based on Measured Guideway Profiles

  • Hwang, Joo-Ho;Park, Chun-Hong;Kim, Seung-Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권2호
    • /
    • pp.64-69
    • /
    • 2007
  • Aerostatic planar XY stages are frequently used as the main frames of precision positioning systems. The machining and assembly process of the rails and bed of the stage is one of first processes performed when the system is built. When the system is complete, the 2D position, motion, and stage flatness errors are measured in tests. If the stage errors exceed the application requirements, the stage must be remachined and the assembly process must be repeated. This is difficult and time-consuming work. In this paper, a method for estimating the errors of a planar XY stage is proposed that can be applied when the rails and bed of the stage are evaluated. Profile measurements, estimates of the motion error, and 2D position estimation models were considered. A comparison of experimental results and our estimates indicated that the estimated errors were within $1{\mu}m$ of their true values. Thus, the proposed estimation method for 2D position and flatness errors of an aerostatic planar XY stage is expected to be a useful tool during the assembly process of guideways.