• 제목/요약/키워드: xenon

검색결과 282건 처리시간 0.033초

Study on the Performance of Infrared Thermal Imaging Light Source for Detection of Impact Defects in CFRP Composite Sandwich Panels

  • Park, Hee-Sang;Choi, Man-Yong;Kwon, Koo-Ahn;Park, Jeong-Hak;Choi, Won-Jae;Jung, Hyun-Chul
    • 비파괴검사학회지
    • /
    • 제37권2호
    • /
    • pp.91-98
    • /
    • 2017
  • Recently, composite materials have been mainly used in the main wings, ailerons, and fuselages of aircraft and rotor blades of helicopters. Composite materials used in rapid moving structures are subject to impact by hail, lightning, and bird strike. Such an impact can destroy fiber tissues in the composite materials as well as deform the composite materials, resulting in various problems such as weakened rigidity of the composite structure and penetration of water into tiny cracks. In this study, experiments were conducted using a 2 kW halogen lamp which is most frequently used as a light source, a 2 kW near-infrared lamp, which is used for heating to a high temperature, and a 6 kW xenon flash lamp which emits a large amount of energy for a moment. CFRP composite sandwich panels using Nomex honeycomb core were used as the specimens. Experiments were carried out under impact damages of 1, 4 and 8 J. It was found that the detection of defects was fast when the xenon flash lamp was used. The detection of damaged regions was excellent when the halogen lamp was used. Furthermore, the near-infrared lamp is an effective technology for showing the surface of a test object.

방사성제논 탐지를 위한 베타-감마 동시 계측시스템의 측정시간 최적화 (Optimization of Acquisition Time of Beta-Gamma Coincidence Counting System for Radioxenon Measurement)

  • 변종인;박홍모;최희열;송명한;윤주용
    • Journal of Radiation Protection and Research
    • /
    • 제40권3호
    • /
    • pp.181-186
    • /
    • 2015
  • 방사성 제논 탐지는 공기 중 $^{131m}Xe$, $^{133}Xe$, $^{133m}Xe$$^{135}Xe$를 저준위 백그라운드 계측 시스템으로 검출하여 지하 핵실험 여부를 규명하는 핵심기술 중 하나이다. 방사성 제논 감시는 공기 포집, 제논 추출, 측정 및 분석을 통해 수행되며, $^{135}Xe$의 최소검출가능농도는 비교적 짧은 반감기로 인해 포집, 추출 및 측정시간에 따라 큰 차이를 보이게 된다. 본 연구에서는 방사성 제논 계측 시스템의 정해진 시료 포집 및 전처리 조건에서 최적의 방사성 제논 측정시간을 도출하기 위해 이론적 접근 및 SAUNA 시스템을 이용한 실험을 통해 최소의 MDC를 보이는 측정시간을 결정하고 이론적 계산과 실험결과에 대하여 비교 평가하였다.

소형위성용 전기추진시스템을 위한 연료공급부의 발사환경 시험평가 (Launch Environment Test and Evaluation of Fuel Feeding Unit for Electric Propulsion System to Small-Satellite Applications)

  • 김연호;강석현;정연황;강성민;선종호;이상현;차원호;은희광
    • 한국항공우주학회지
    • /
    • 제42권12호
    • /
    • pp.1051-1056
    • /
    • 2014
  • 소형인공위성에 적용을 목적으로 전기추진시스템의 연료공급부가 개발되었다. 연료공급부는 연료로 사용되는 제논을 높은 압력과 밀도의 가스상태로 저장하게 된다. 제논은 상온에서 임계점을 갖는데 발사환경에서 과도상태로 시스템에 영향을 미칠 수 있다. 따라서 발사환경에 대한 본 시스템의 기능적 구조적 안정성은 지상시험을 통한 검증이 필요하다. 본문에서는 연료공급부의 설계점과 검증시험내용을 논하고 시험결과를 정리하였다. 검증시험을 통해 본 시스템이 발사환경에 대하여 안정성을 확보하고 있는 것을 확인하였다.

비활성 기체의 증기압 예측 (Prediction of Vapor Pressure of the Inert Gases)

  • 정재관
    • 대한화학회지
    • /
    • 제47권6호
    • /
    • pp.541-546
    • /
    • 2003
  • 문헌에 보고된 기존의 비활성 기체의 증기압 측정값을 이용하여 환원증기압과 환원온도 형태의 아래와 같은 식의 상수 A, B, C, D와 지수 n을 구하는데 사용하였다: $InP_r=A+{\frac{B}{T_r}+CInT_r+DT_n^r}$ 오차분석법에 의해 위 식에 적용되는 비활성 기체의 각 기체 Ar, Kr, Xe, He과 Ne에 대한 가장 정확한 지수와 4개의 상수를 얻었다. 위 식을 통해 각 기체의 증기압을 계산하기 위해서 필요한 것은 정상 끓는점, 임계압력 및 임계온도뿐이며 5개의 비활성 기체의 406개 증기압 실험값에 적용하여 본 결과 전체 평균편차가 0.31% 였다. Ar, Kr, Xe에 대한 평균편차는 각각 0.24%, 0.09%, 0.22%였으며, Ne은 1.31%, He은 0.61%이다. 이러한 결과는 He과 연관된 큰 양자효과와 Ne에 대한 적은 양자효과 때문에 예상된 것이다.

제논 플래시 램프 사용 시 조사 영역 균일도 개선을 위한 반사경 설계 (Reflector Design to Improve the Uniformity of an Irradiated Area Using a Xenon Flash Lamp)

  • 김서영;이한율;전원균;강동화;조예지;정미숙
    • 한국광학회지
    • /
    • 제30권5호
    • /
    • pp.197-203
    • /
    • 2019
  • 본 논문은 광 소결 공정에 쓰이는 제논 플래시 램프 사용 시 조도 균일도를 개선시킬 수 있는 반사경 설계에 대한 연구를 진행하였다. 조사 영역에서 기판의 완전한 소결이 이루어지기 위해서 광효율과 조도 균일도를 목표 성능으로 설정하였다. 기존의 타원 반사경 또는 포물 반사경을 이용한 방식은 광효율을 만족하기 용이하지만 조도 균일도를 만족하는데 어려움이 있다. 따라서 본 논문에서는 조도 균일도를 만족시키기 위해 포물경의 중앙부에 쌍오목 형상을 추가하였다. 이러한 쌍오목 형태의 중앙부 형상을 갖는 포물 반사경의 조도 균일도가 기존의 반사경에 비해 향상됨을 확인하였다.

녹색발광 Zn2SiO4:Mn2+ 형광체가 코팅된 엑시머 램프의 제작 및 특성 (Fabrication and Property of Excimer Lamp Coated with Green-emitting Zn2SiO4:Mn2+ Phosphor Film)

  • 강부식;정현지;정용석;손세모;김종수
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.106-109
    • /
    • 2022
  • The green-emitting Zn2SiO4:Mn2+ phosphor film was evaluated in a xenon excimer lamp. The phosphor film with 2 ㎛ thick was formed of monolithic structure on the inner side of quartz through a long-time annealing process of coated ZnO solution doped with Mn2+ ion and SiO2 of quartz tube. The coated quartz was filled with 100 torr of xenon gas, and simultaneously both sides was melt and sealed. The xenon-field quartz tube was discharge by applying the voltage of 15 kV with a frequency of 26 kHz, and emitted the glow with dominant peak at 172 nm. The vacuum ultraviolet excited the inner-side coated Zn2SiO4:Mn2+ phosphor film, which emitted the pure and strong green light.

원자로에 있어서 Xenon 독소의 최적제어 (Optimal Control of Xenon Poison In Nuclear Reactor)

  • 곽은호;고병준
    • 대한전자공학회논문지
    • /
    • 제13권5호
    • /
    • pp.17-23
    • /
    • 1976
  • 고속열중성자로에서 정상 운전중인 원자로를 운전정지하였다가 재가동할 때 가장 문제가 되는 것은 핵분열 생성물인 Xe135의 독소작용이다. 이것은 Xe135가 원자로 출력에 영향을 주는 열중성자에 대한 흡수단면적이 크고 그의 반감기가 길기 때문이다. 그러므로 원자로의 일시적 운전정지가 요구될 때 이의 재가시에는 반듯이 이 독소를 능과할 수 있는 충분한 초과반응도를 가해 주던지, Xe135가 붕괴되어 그의 농도가 줄어든 이후에야 원자로의 재가동이 가능하게 된다. 위와 같은 문제는 사실상 원자로 운전시 안전성 뿐만 아니라 경제성에도 큰 영향을 주고 있다. 본 논문에서는 이 점을 고려하여 Pontoyagin의 최대원리를 이용하여 운전정지를 최적화시키므로서 언제든지 원자로를 전출력으로 재가동할 수 있도록 운전정지 방법을 개선하였다. 그러나 제어과정에서나 그 이후에도 X, 농도는 제어된 허용치를 넘지 않고 최소시간 이내에 모든 제어를 끝내도록 하였다. The buildup of fission product, i.e. Xe-135 poisoning, is a prime factor in restarting a nuclear reactor from the shutdown, which was under normal operation in the high flux thermal reactor, It is caused by the high absorption crosssection of Xe-135 to thermal neutrons and its long half life, from which the thermal power is affected. It is then possible to restart a nuclear reactor after the sufficient excess reactivity to override this poisoning must be inserted, or its concentration is decreased sufficiently when its temporary shutdown is required. As ratter of fact, these have an important influence not only on reactor safety but also on economic aspect in operation. Considering these points in this study, the shutdown process was cptimized using the Pontryagin's maximum principle so that the shutdown mirth[d was improved as to restart the reactor to its fulpower at any time, but the xenon concentration did not excess the constrained allowable value during and after shutdown, at the same time all the control actions were completed within minimum time from beginning of the shutdown.

  • PDF

The Helium-Xenon Interaction Potential

  • Elaheh K. Goharshadi;Majid Moinssadati
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권9호
    • /
    • pp.945-947
    • /
    • 2001
  • The He-Xe interaction potential has been determined using a direct inversion of the experimentally reduced-viscosity collision integrals obtained from the corresponding states correlation. The potential is in a good agreement with the previously determined potential. The potential predicts viscosity and diffusion coefficients and they are found to be in a good agreement with experiment.

Hyperpolarized 129 NMR Study of TiO2 Nanotubes

  • Lee, Sang-Man;Lee, Soon-Chang;Mehrotra, Vandana;Kim, Hae-Jin;Lee, Hee-Cheon
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권2호
    • /
    • pp.511-514
    • /
    • 2012
  • A continuous flow hyperpolarized (HP) $^{129}Xe$ NMR spectroscopy was employed for the first time to investigate $TiO_2$ nanotubes (Ti-NTs) synthesized from commercial nanoparticles with different reaction times. A single peak attributing to channels for Ti-NTs was observed for variable temperature HP $^{129}Xe$ NMR spectra. It was also noted that there is alteration in value for heat of adsorption, ${\Delta}H$ from $12.6{\pm}1.3$ to $16.4{\pm}0.4kJ/mol$ and variation in chemical shift of the xenon adsorbed in channels, ${\delta}_s$ from $120{\pm}2\sim135{\pm}9ppm$ which were closely correlated to channel length and it was shown that P25-24 Ti-NTs with longest channel is most favorite Ti-NTs for Xe adsorption.