• Title/Summary/Keyword: x-ray imaging

Search Result 1,065, Processing Time 0.041 seconds

Study on the Production Methods and Conservation Treatment of the Gold Earrings Excavated from the Ancient Tombs in Seokchon-dong in Seoul (석촌동 고분군 출토 금제이식의 제작기법 연구 및 보존처리)

  • Kim, Yeseung;Jeong, Seri;Lee, Dahye;Jang, Minkyeong;Kim, Naeun;Yang, Seokjin
    • Conservation Science in Museum
    • /
    • v.26
    • /
    • pp.143-160
    • /
    • 2021
  • The Seoul Baekje Museum has been conducting excavations at the Ancient Tomb Complex in Seokchon-dong, Seoul (Historic Site No. 243), known to be tombs of the royal family and the ruling class during the Hanseong period of the Baekje Kingdom. In this study, gold earrings that were revealed during the excavation underwent scientific analysis and conservation treatment. Stereo microscopy, SEM, X-ray imaging, CT, and XRF were applied in the analysis, and the characteristics, internal structure, and composition of the earrings as well as their production method were investigated. The results confirmed that the main hoops of the gilt-bronze earrings were made of copper cores gilt using mercury amalgamation. The findings also revealed that the hexahedron in the middle pendant was made by connecting small rings using molten gold powder, and the pendant sphere at the end was formed by soldering two hemispheres. As for the two thin-hoop earrings, they showed similar surface compositions but were made using different methods, with one made from a copper core wrapped with a gold plate and the other made by bending a gold rod. The gold content varied depending on the item and the place of measurement, but overall the earrings showed a relatively high gold content of approximately 19 to 21K. The purity of the golden earrings and the sophisticated manufacturing techniques applied indicate the high status of the buried person and of the tomb complex in Seokchong-dong.

Extent of Subprosthetic Pannus after Aortic Valve Replacement: Changes Over Time and Relationship with Echocardiographic Findings (대동맥판막치환술 후 발생한 판막하 판누스(Pannus): 시간에 따른 변화 및 심초음파 소견)

  • Mi Yeon Park;Hyun Jung Koo;Hojin Ha;Joon-Won Kang;Dong Hyun Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1151-1163
    • /
    • 2020
  • Purpose This study aimed to evaluate changes of subprosthetic pannus on cardiac CT and determine its relationship to echocardiographic findings in patients with mechanical aortic valve replacement (AVR). Materials and Methods Between April 2011 and November 2017, 17 AVR patients (56.8 ± 8.9 years, 12% male) who showed pannus formation on CT and had undergone both follow-up CT and echocardiography were included. The mean interval from AVR to the date of pannus detection was 10.5 ± 7.1 years. In the initial and follow-up CT and echocardiography, the pannus extent and echocardiographic parameters were compared using paired t-tests. The relationship between the opening angle of the prosthetic valve and the pannus extent was evaluated using Pearson correlation analysis. Results The pannus extent was significantly increased on CT (p < 0.05). The peak velocity (3.9 ± 0.8 m/s vs. 4.2 ± 0.8 m/s, p = 0.03) and mean pressure gradient (36.4 ± 15.5 mm Hg vs. 42.1 ± 15.8 mm Hg, p = 0.03) were significantly increased. The mean opening angles of the mechanical aortic leaflets were slightly decreased, but there was no statistical significance (73.1 ± 8.3° vs. 69.4 ± 12.1°, p = 0.12). The opening angle of the prosthetic leaflets was inversely correlated with the pannus extent (r = -0.57, p < 0.001). Conclusion The pannus extent increases over time, increasing transvalvular peak velocity and the pressure gradient. CT can be used to evaluate the pannus extent associated with hemodynamic changes that need to be managed by surgical intervention.

Usefulness of LIFE in diagnosis of bronchogenic carcinoma (기관지 암의 진단에서 형광기관지 내시경검사의 유용성)

  • Lee, Sang Hwa;Shim, Jae Jeong;Lee, So Ra;Lee, Sang Youb;Suh, Jung Kyung;Cho, Jae Yun;Kim, Han Gyum;In, Kwang Ho;Choi, Young Ho;Kim, Hark Jei;Yoo, Se Hwa;Kang, Kyung Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.69-84
    • /
    • 1997
  • Background : Although the overall prognosis of patients with lung cancer is poor, highly effective treatment exists for the small subset of patients with early lung cancer(carcinoma in situ/micro- invasive cancer). But very few patients have benefit from them because these lesions are difficult to detect and localize with conventional white-light bronchoscopy. To overcome this problem, a Lung Imaging Fluorescence Endoscopic device(LIFE) was developed to detect and clearly delineate the exact location and extent of premalignant and early lung cancer lesions using differences in tissue autofluorescence. Purpose : The purpose of this study was to determine the difference of sensitivity and specificity in detecting dysplasia and carcinoma between fluorescence imaging and conventional white light bronchoscopy. Material and Methods : 35 patients (16 with abnormal chest X-ray, 2 with positive sputum study, 2 with undiagnosed pleural effusion, 15 with respiratory symptom) have been examined by LIFE imaging system. After a white light bronchoscopy, the patients were submitted to fluorescence bronchoscopy and the findings of both examinations have been classified in 3 categories(class I, II, III). From of all class n and III sites, 79 biopsy specimens have been collected for histologic examination: a comparison between histologic results and white light or fluorescence bronchoscopy has been performed for assessing sensitivity and specificity of the two methods. Results : 1) Total 79 sires in 35 patients were examined. Histology demonstrated 8 normal mucosa, 21 hyperplasia, 23 dysplasia, and 27 microinvasive and invasive carcinoma. 2) The sensitivity of white light or fluorescence bronchoscopy in detecting dysplasia was 60.9% and 82.6%, respectively. 3) The results of this study showed 70.3 % sensitivity for microinvasive or invasive carcinoma with LIFE system, versus 100% sensitivity for white light in 27 cases of carcinoma. The false negative study of LIFE system was 8 cases(3 adenocarcinoma and 5 small cell carcinoma), which were infiltrated in submucosal area and had normal epithelium. Conclusion : To improve the ability 10 diagnose and stage more accurately, fluorescence imaging may become an important adjunct to conventional bronchoscopic examination because of its high detection rate of premalignant and malignant epithelial lesion. But. it has limitation to detect in submucosal infiltrating carcinoma.

  • PDF

Bone Mineral Density Measurement of Rats Using Dual-energy X-ray Absorptiometry: Precision of In Vivo Measurements for Various Skeletal Sites with or without Repositioning (쥐에서 이중에너지 방사선 흡수법을 이용한 골밀도의 측정: 다양한 골부위에서 재위치 여부에 따른 생체내 측정의 정밀도)

  • Oh, Dong-Hyun;Jung, Jae-Ho;Woo, Sang-Keun;Cheon, Gi-Jeong;Kim, Byung-Il;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.72-78
    • /
    • 2009
  • Purpose: Bone mineral density (BMD) measurements need to be precise enough to be capable of detecting small changes in bone mass of rats. Using a regular dual-energy X-ray absorptiometry (DXA), we measured many BMD of various skeletal sites in rats to examine precision of DXA in relation to the repositioning on the bones of rats. Materials and Methods: Using DXA and small animal software, scans were performed 4 times in all 12 male rats without repositioning (Group 1a). Another four scans for 6 of 12 rats were done with repositioning between scans (Group 2). Customized regions of interest (ROIs), encapsulate the right hind limb, L1-4, skull and pelvic bones were drawn at each measurement. The precision of the measurements was evaluated by measuring the coefficient of variation (CV) of four measurements of BMD at each skeletal site of all rats with or without repositioning. Significance of differences between group 1b (six rats out of group 1a, which were come under group 2) and group2 were evaluated with Wilcoxon Signed Rank Sum Test. Results: CVs obtained at different skeletal sites of all measurements in Group 1b and 2. It was $3.51{\pm}1.20$, $ 2.62{\pm}1.20$ for the hindlimb (p=0.173), $3.83{\pm}2.02$, $4.59{\pm}2.02$ for L1-4 (p=0.600), $3.73{\pm}1.87$, $1.53{\pm}0.89$ for skull (p=0.046), and $2.92{\pm}0.60$, $1.45{\pm}0.60$ for pelvic bones (p=0.075). Conclusion: Our study demonstrates that the DXA technique has the precision necessary when used to assess BMD for various skeletal sites in rats regardless of repositioning.

Comparison of Electrical Signal Properties about Top Electrode Size on Photoconductor Film (광도전체 필름 상부 전극크기에 따른 전기적 신호 특성 비교)

  • Kang, Sang-Sik;Jung, Bong-Jae;Noh, Si-Cheul;Cho, Chang-Hoon;Yoon, Ju-Sun;Jeon, Sung-Pyo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.93-96
    • /
    • 2011
  • Currently, the development of direct conversion radiation detector using photoconductor materials is progressing in widely. Among of theses photoconductor materials, mercuric iodide compound than amorphous selenium has excellent absorption and sensitivity of high energy radiation. Also, the detection efficiency of signal generated in photoconductor film varies by electric filed and geometric distribution according to top-bottom electrode size. Therefore, in this work, the x-ray detection characteristics are investigated about the size of top electrode in $HgI_2$ photoconductor film. For sample fabrication, to solve the problem that is difficult to make a large area film, we used the spatial paste screen-print method. And the sample thickness is $150{\mu}m$ and an film area size is $3cm{\times}3cm$ on ITO-coated glass substrate. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a magnetron sputtering system and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$. From experimental measurement, the dark current, sensitivity and SNR of the $HgI_2$ film are obtained from I-V test. From the experimental results, it shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high dark current. Therefore, the optimized size of electrode is importance for the development of photoconductor based x-ray imaging detector.

A Study of Radiation Incidence Angle in Cervical Vertebra Anteroposterior(AP) Examination by Position (자세에 따른 목뼈 정면 입사각에 대한 연구)

  • Kwak, Jonghyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.101-107
    • /
    • 2015
  • In anteroposterior radiation test for cervical vertebra, it is general that the incidence angle of X-ray is $15^{\circ}$ to $20^{\circ}$ degrees to head regardless of position. So this study suggests appropriate incidence angle of cervical vertebra depended on the position. From 1 January 2013 to 31 December 2013, cervical spine radiographys and magnetic resonance imaging was performed in 107 people who visited P Hospital located in Pusan. Among them, 39 people(men 24, women 15) were below 80 above 20 years old(average age 54 years) with normal cervical lordosis(normal $40^{\circ}{\pm}5^{\circ}$). In erect position, the incidence angle of cervical vertebra is measured from lateral radiographic images. And in supine position, it measured from MRI sagittal images. Results based on gender, the incidence angle of cervical vertebra in erect position was $25.9^{\circ}$ for men, women was $23.1^{\circ}$, showed statistically significant (p<0.05). And the angle in supine was $11.6^{\circ}$ for men, women was $12.6^{\circ}$, showed not statistically significant (p>0.05) An analysis of age group shows, the incidence angle of cervical vertebra in erect position was $24.6^{\circ}$ under 50, and $25.0^{\circ}$ over 50. The angle in supine was $12.0^{\circ}$ under 50, and $11.9^{\circ}$ over 50. And all of them showed not statistically significant (p>0.05). At all ages, the average of incidence angles in erect position were $24.8^{\circ}$, and the angle in supine was $12.0^{\circ}$, showed statistically significant (p<0.05). The cervical vertebra incidence angle for X-ray was $15^{\circ}$ to $20^{\circ}$ degrees to head in general. But, through the results, it is recommended that the angle is $24.8^{\circ}$ in erect and $12.0^{\circ}$ in supine position. It could be shown true anteroposterior(AP) view of cervical vertebra and accurate intervertebral fusion fixing devices.

Conservation and Scientific Analysis of Human Bone Excavated in Sabi Period of Baekje from Eungpyeong-ri, Buyeo (부여 응평리 출토 백제 사비기 인골 보존처리 및 과학적 분석)

  • KIM, Mijeong;LEE, Yunseop;CHO, Eunmin;PARK, Sujin;MOON, Minseong
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.1
    • /
    • pp.305-321
    • /
    • 2022
  • The stone chamber tomb in Eungpyeong-ri, Buyeo, is a joint tomb that contains the bodies of two individuals. This paper investigates the relationship between the buried persons and the characteristics of the stone chamber tomb. Based on the geographical location, relics, and the excavated human bones, it was determined that the tomb was built during the Sabi Period of the Baekje Dynasty and that the buried individuals were most probably residents of high stature or government officials. To study the excavated bones, the remains were carefully collected and conservation was carried out. Before collecting samples from the human bones for the analytical research, the results of near-infrared analysis were used to collect the samples for the isotope analysis and DNA analysis. The most important issue when handling the excavation site was the reinforcing agent and the concentration of the agent used. In situations like this, Paraloid B-72 is the most suitable agent. When the shape of human bones was difficult to distinguish from the soil, conservation was performed using X-ray and CT imaging data. The same chemical used for the reinforcement of the site was used to complete a minimum level of conservation to the surface areas where the conservation treatment of removing foreign substances, the reinforcement areas, and bonded areas were carried out. The collagen yield from the sample obtained at selected position was 3.8% to 6.1%. The results of analyzing the stable isotopes of carbon and nitrogen found in the extracted collagen showed that the stable isotope ratios came out to δ13C -18.3‰±0.1‰, -19.0‰±0.1‰ for EBW and δ15N 10.7‰±0.5‰, 10.6‰±0.1‰ for EBE. It is believed the two individuals consumed small amounts of minor cereals, mainly from C3 plants, and protein was obtained from eating terrestrial animals. What's more, the deviations in data obtained from the two individuals were so small that it could be inferred that the individuals ate similar foods. Considering the preservation state of the sample, amplifying DNA for the DNA analysis would have been very difficult since the amount of surviving DNA was so deficient. For DNA analysis, it is anticipated that the results could be derived by applying improved extraction methods that will be developed in the future. In this research, any association between scientific analysis(DNA and stable isotope ratio) and near-infrared spectroscopy was difficult to establish. Further research is needed on the utilization of near-infrared analysis for gathering samples from human bones.

Predictive Value for Vesicoureteral Reflux in Children with Urinary Tract Infection (요로감염 환아에서 방광요관 역류를 예측할 수 있는 인자에 대한 연구)

  • Lee, Seung-Hyun;Noh, Sung-Hoon;Oh, Jeung-Eun;Kim, Min-Sun;Lee, Dae-Yeol
    • Childhood Kidney Diseases
    • /
    • v.12 no.1
    • /
    • pp.62-69
    • /
    • 2008
  • Purpose: The most concerning issue in children with urinary tract infection(UTI) is the probability of underlying genitourinary anomalies and vesicoureteral reflux (VUR), which is frequently associated with renal scarring and eventually end-stage renal disease. Therefore, voiding cystourethrography(VCUG) is usually recommended at the earliest convenient time for children with UTI. However, VCUG is an invasive procedure that requires catheterization and exposure to X-ray. In this study, we aimed to determine the predictability of clinical, laboratory and imaging parameters for VUR in children with UTI. Methods: Data of children with bacteriologically proven UTI who underwent VCUG were evaluated retrospectively for clinical(age, gender, fever), laboratory(leukocytosis, ESR, CRP, pyuria, blood urea nitrogen, serum creatinine) and imaging(renal ultrasound and DMSA renal scan) findings. First, children with UTI were divided into two groups according to the presence of VUR as non-VUR group and with VUR group, and clinical, laboratory variables were compared between these groups. Second, patients who had VUR were reclassified as low-grade VUR(grade I-II) group and high-grade(grade III-V) VUR group according to grading of VUR, and clinical, laboratory and imaging variables were compared between these groups. Results: Among 410 children with UTI, 137 had VUR and 78 high-grade VUR. Fever, leukocytosis, ESR, CRP, pyuria were associated with VUR. In addition, abnormal findings of ultrasonography and DMSA renal scan were closely related to VUR. However, these clinical and laboratory variable in patients with high grade VUR were not different significantly, compared to those with low-grade VUR group. Conclusion: Fever, leukocytosis, ESR, CRP seems to be potentially useful predictors of VUR in pediatric patients with UTI. In addition, renal ultrasonography and DMSA renal scan findings supported the presence of VUR. Further study of these findings could limit unnecessary VCUG in patients with UTI.

  • PDF

Comparative Analysis of Image Quality and Adverse Events between Iopamidol 250 and Ioversol 320 in Hepatic Angiography for Transcatheter Arterial Chemoembolization (경동맥 화학색전술을 위한 간동맥 혈관조영술에서 Ioversol 320과 비교한 Iopamidol 250의 영상 화질 비교 분석과 조영제 유해반응 평가)

  • Min Jae Gu;Jae Hyuck Yi;Young Hwan Kim;Hee Jung Lee;Ung Rae Kang;Seung Woo Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.166-175
    • /
    • 2020
  • Purpose This study aimed to compare the image quality and adverse events between Iopamidol 250 and Ioversol 320 usage during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). Materials and Methods Medical records and hepatic angiography from 113 patients who underwent TACE with Iopamidol 250 (44 patients) and Ioversol 320 (69 patients) were retrospectively reviewed. Vessel perception on hepatic angiography was graded into three categories by two radiologists for hepatic subsegmental arteries, the right gastroepiploic artery, right gastric artery, and pancreaticoduodenal artery. Imaging concordance was assessed by comparing the number of detected HCCs on hepatic angiography and CT. The adverse events before and after hepatic angiography were evaluated. Results The mean vessel perception scores were 2.92 and 2.94 for Iopamidol 250 and Ioversol 320, respectively. The imaging concordance was 31 (70.5%) and 46 (66.7%) patients for Iopamidol 250 and Ioversol 320, respectively. There were no statistical differences in vessel perception or imaging concordance (p > 0.05). One and six patients experienced nausea for Iopamidol 250 and Ioversol 320, respectively. There was no statistical difference in adverse events (p = 0.24). Conclusion Iopamidol 250 can be used in hepatic angiography for TACE without significant difference in image quality or occurrence of adverse events from Ioversol 320.

Radiographic differential diagnosis between ameloblastoma and odontogenic keratocyst: with emphasis on CT (법랑모세포종과 치성각화낭의 방사선학적 감별진단 : CT를 중심으로)

  • Soh Byung-Chun;Heo Min-Suk;An Chang-Hyeon;Choi Mi;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.167-173
    • /
    • 2002
  • Purpose : To evaluate clinical and radiographic differential diagnosis between ameloblastoma and odontogenic keratocyst (OKC) using clinical data, plain radiographs, and CT. Materials and Methods: 25 cases of ameloblastoma and 44 cases of OKC diagnosed in biopsy, were selected from the files stored in Department of Oral and Maxillofacial Radiology, Seoul National University Dental Hospital from 1999 to 2001, and evaluated using following criteria: sex and age, location, shape, border to normal bone tissue, effect to adjacent tissues, homogeneity in the lumen of the lesion, response of the cortical bone, long-to-short length (LIS) ratio of the lesion, and expansion angle of the cortex. Results: Ameloblastoma and OKC were seen most frequently in third decades and no statistical significance was noted between both sexes. Ameloblastoma occurred most frequently in mandibular angle and ramus area (68%) and OKC at the maxillary molar (34.1 %), and mandibular angle and ramus area (43.2%). The root resorption of the adjacent teeth, mandibular canal displacement, and the impaction of teeth were seen more frequently in ameloblastoma than in OKC. The LIS ratio measured in CT was largest in maxillary OKC cases, followed by mandibular ameloblastoma, and mandibular OKC (1.2, 1.8 and 2.4 respectively). The expansion angle of the cortex shows a statistically significant difference between ameloblastoma (48.8°) and OKC (31.5°). Conclusion : The numeric morphology (LIS ratio) and expansion angle of the cortical bone of the lesion measured in computed tomography can be used to differentiate the ameloblastoma and odontogenic keratocyst.

  • PDF