• Title/Summary/Keyword: x-ray

검색결과 16,631건 처리시간 0.051초

악관절잡음 및 동통을 동반한 정복성 관절원판 변위환자에 대한 관절강 Pumping 효과 (The Effect of Joint Space Pumping Treatment in Patients with Reducible Disc Displacement Accompanied by TMJ Sound and Pain)

  • 김현철;최종훈;박혜숙;김종열
    • Journal of Oral Medicine and Pain
    • /
    • 제24권1호
    • /
    • pp.9-24
    • /
    • 1999
  • Pumping into the upper joint cavity of the TMJ was done on patients who had reducible disc displacement with pain. This article discusses the change in TMJ sounds before and after the Pumping treatment. 20subjects(mean age of $32.1{\pm}10.2yr$)were selected among those who visited the department of Oral Medicine of Yonsei University for the treatment of craniomandibular dysfunctions. Through a thorough history taking, clinical exam and X-ray taking these subjects were diagnosed as reducible disc displacement patients, and they were subdivided into two groups as acute and chronic according to the time the TMJ sound was made. Sonopak was used to measure the TMJ sound before, right after and one-week after the Pumping treatment. VAS was used to measure the degree of subjective TMJ complaints(sounds and pain) before and one-week after the Pumping treatment. Vibration related items included total integral, high integral, low integral, ratio of high integral to low integral, peak amplitude, peak frequency and median frquency. 1. It was not statistically significant between the acute and chronic groups before the treatment. However, total integral, high integral, low integral, peak amplitude, peak frequency, median frequency showed to be greater in the chronic group. 2. In all the subjects, just after the Pumping treatment was done, total integral, high and low integral, peak amplitude and peak frequency significantly decreased (p<0.05). Even after one week, low integral, peak frequency and median frequency significantly decreased (p<0,05), and the TMJ sound diminished accordingly. 3. Comparing the two groups(before and right after the Pumping treatment), there was the following difference ; in the acute group, high integral, high amplitude, high frequency and median frequency significantly decreased(p<0.05). In the chronic group, total integral, high integral, low integral, ratio, peak amplitude and peak frequency significantly decreased(p<0,05). It was not statistically significant between the acute and chronic group. 4. Comparing the two groups(right after and one week after the Pumping treatment), there was the following difference : in the acute group, high integral, high amplitude, high frequency and median frequency significantly decreased(p<0.05), In the chronic group, low integral significantly decreased(p<0.05). However, although it was not statistically significant, after one week, there was an increase in total integral, ratio, peak amplitude and peak frequency compared to right after the treatment group. 5. In the VAS of before and one week after the Pumping treatment of the TMJ pain and sound, the TMJ pain significantly decreased(p<0.05) in both the acute and chronic group. However, it was not statistically significant between the two groups. There was a statistically significant decrease(p<0.05) in the TMJ sound in the acute group after one week of Pumping treatment, but no change was notable in the chronic group and it was not statistically significant between the two groups. From the above results, we can conclude that Pumping into the upper joint cavity of patients having reducible disc displacement is effective in reducing clicking and pain. Therefore, it can be applied in diverse clinical fields.

  • PDF

진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구 (A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea)

  • 김유현;최종학;김성수;이창엽;조평곤;이영배;김철민
    • 한국의학물리학회지:의학물리
    • /
    • 제16권1호
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA는 영상의 질에 영향을 주지 않는 범위에서 피부흡수선량의 기준선량을 제시하였다. 이러한 개념은 점차적으로 국제적인 기준으로 사용하게 되었다. 이 기준선량은 강제사항이 아니며 권고사항이지만 방사선촬영에서 아주 훌륭한 기준이 된다. 그러나 IAEA에서 제공한 선량기준은 서양 사람을 기준으로 개발된 것이어서 우리나라 사람에게는 맞지 않고, 상대적으로 우리나라의 환자선량은 적으리라 예상된다. 따라서 방사선촬영 시 촬영부위에 따른 환자 피폭선량에 대한 기준을 따로 개발해야 할 필요가 있다. 본 연구팀은 병원협회에 등록되어 있는 종합병원 278개를 대상으로 환자 피폭에 대한 설문조사를 실시하였다. 설문회수율은 57.9%였으며 각 병원에서 답한 촬영조건을 기초로 NDD법을 이용하여 환자 피폭선량을 계산하였고 방사선장치의 이용현황을 분석한 결과는 다음과 같다 1) 방사선장치의 현황은 일반촬영장치가 42.0%, 투시촬영장치가 29.4%, 치과장치가 13.2%, CT 장치가 8.1% 그리고 유방촬영장치가 7.2%로 나타났다. 2) 방사선장치의 정류방식에 따른 분류는 삼상장치가 29.9%, 인버터장치가 29.5%, 단상장치가 25.5%, 콘덴서방식이 9.0% 그리고 무응답이 6.0%였다. 3) 방사선장치의 수광방식에 따른 분류는 F/S 방식이 46.8%, CR 방식이 26.6%, DR 방식이 17.7% 그리고 무응답이 8.9%로 나타났다. 4) 방사선 촬영건수는 흉부가 49.2%, 척추가 16.8% 그리고 복부가 12.7%순으로 나타났다. 5) 환자 피폭선량은 두부 전후방향촬영 2.23 mGy, 복부 전후방향촬영 3.20 mGy 그리고 흉부 후전방향촬영 0.28 mGy로 나타났다.

  • PDF

미생물을 이용한 자철석으로부터 철 침출에 관한 연구 (Microbial Leaching of Iron from Magnetite)

  • 노열;오종민;서용재;장희동
    • 한국광물학회지
    • /
    • 제19권4호
    • /
    • pp.265-275
    • /
    • 2006
  • 미생물을 이용한 원석 또는 폐석으로부터 인류에 유용한 원소 및 중금속의 용출은 초기 연구단계에 있는 새로운 생물학적 기술 중의 하나이다. 본 연구의 목적은 갯벌 퇴적물에서 분리한 미생물(Microcosm)을 이용하여 자철석으로부터 철의 용출 및 용출된 철의 생광화작용에 따른 2차 물질의 형성을 규명하고자 한다. 갯벌퇴적물에서 분리한 철 환원 박테리아(Microcosm)가 글루코스($10{\sim}20mM$)를 이용하여 성장하는 동안 자철석으로부터 철의 용출 및 2차 물질의 형성을 ICP, XRD, SEM-EDX 및 TEM을 이용하여 연구하였다. 미생물배지에 상업용 자철석(미생물배지 : 자철석 = 100 : 1)과 철환원 박테리아를 넣고 혐기성 및 호기성 조건하에서 철 용출 및 2차 물질의 형성실험을 실시한 결과, 철의 용출 실험동안 미생물배지의 Eh는 호기성 조건에서 +250 mV에서 -520 mV 까지 감소하고, pH 7.3에서 5.5까지 감소하였다. 혐기성 환경에서 박테리아의 활동에 따라 15일째 자철석으로부터 94 ppm의 Fe를 용출하였으며, 박테리아가 없는 혐기성 조건 하에서는 0.9 ppm의 Fe의 용출을 보여 주었다. 호기성 환경에서 박테리아의 활동에 따라 자철석으로부터 15일째 107 ppm의 Fe를 용출하였다. 배양을 시작한지 1개월이 지난 시점에서는 미생물배지에 용출되어 있는 Fe가 혐기성 조건에서는 57ppm의 Fe가, 호기성 조건하에서는 6.5 ppm의 Fe 각각 존재하였다. 박테리아가 배양되는 동안 용출된 철의 감소는 2차물질의 형성에 철이 소비된 것으로 사료되며, 호기성 조건하에서는 적갈색의 2차 물질 형성을 보여주었다. 미생물에 의한 자철석으로부터 철과 망간의 용출은 미생물의 활동에 따른 미생물배지의 열역학적인 조건(Eh/pH)의 변화 및 유기물의 산화에 따른 유기산의 형성에 기인한 것으로 사료된다. 미생물을 이용한 결정질의 자철석으로부터 철의 용출 및 비정질의 2차물질의 형성은 미생물의 퇴적물 내에서 철의 순환에 중요한 역할을 담당할 뿐만 아니라 미생물을 이용한 유용물질의 침출(Bioleaching) 및 생광화작용에 따른 광물의 합성 가능성을 시사한다.

전남 화순군 백아산 아천동굴(석회동굴) 동굴생성물을 이용한 생광물화작용 연구 (Carbonate Biomineralization Using Speleothems and Sediments from Baekasan Acheon Cave (Limestone Cave) in Hwasun-gun, Jeollanam-do, South Korea)

  • 김유미;서현희;조경남;정다예;신승원;허민;노열
    • 한국광물학회지
    • /
    • 제31권2호
    • /
    • pp.113-121
    • /
    • 2018
  • 전라남도 화순군에 위치한 백아산 아천동굴은 전남지역에서 발견된 유일한 석회동굴이다. 이 연구에서는 백아산 아천동굴 내부에서 채취한 동굴생성물(동굴산호, 붕암)과 주변 점토 퇴적물의 광물학적 특성을 확인하고, 생성물 내에 존재하는 호기성 미생물을 농화배양하여 탄산염광물을 형성하는 생광물화작용에 대해 알아보고자 하였다. 연구를 위한 시료는 동굴 내 세 지점에서 점토, 동굴산호, 붕암을 채취하였다. XRD 분석결과, 동굴산호와 붕암은 주로 탄산염광물인 Mg가 풍부한 방해석(Mg-rich calcite)으로 이루어져 있었고, 점토는 석영, 백운모, 질석으로 구성되어 있었다. 탄산염광물 형성 미생물의 농화배양을 위하여 각각 소량의 동굴생성물을 D-1 배지에 넣고 상온의 호기 조건에서 미생물을 배양하였다. 그리고 미생물들의 탄산염광물 형성능을 확인하고자 요소가 포함된 D-1 배지에 칼슘이온(Ca-acetate, Ca-lactate)을 주입한 후 각 시료로부터 농화배양된 미생물 배양액을 1% (v/v)씩 주입하였다. 그 결과 모든 조건에서 흰색의 침전물이 형성되었으며, XRD 분석결과 침전물이 방해석과 바테라이트(vaterite)로 구성된 것을 확인하였다. SEM-EDS 분석 결과 Ca, C, O를 주성분으로 하는 능면체, 구형, 주상형의 탄산칼슘이 관찰되었다. 따라서 백아산 아천동굴 내 영구암대에 분포하는 임의의 동굴생성물로부터 확인된 미생물들은 동굴생성물 형성에 관여하고 탄소와 칼슘의 지화학적 순환에 기여했을 것으로 추정된다.

Stellite bearings for liquid Zn-/Al-Systems with advanced chemical and physical properties by Mechanical Alloying and Standard-PM-Route

  • Zoz, H.;Benz, H.U.;Huettebraeucker, K.;Furken, L.;Ren, H.;Reichardt, R.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2000년도 춘계학술강연 및 발표대회 강연 및 발표논문 초록집
    • /
    • pp.9-10
    • /
    • 2000
  • An important business-field of world-wide steel-industry is the coating of thin metal-sheets with zinc, zinc-aluminum and aluminum based materials. These products mostly go into automotive industry. in particular for the car-body. into building and construction industry as well as household appliances. Due to mass-production, the processing is done in large continuously operating plants where the mostly cold-rolled metal-strip as the substrate is handled in coils up to 40 tons unwind before and rolled up again after passing the processing plant which includes cleaning, annealing, hot-dip galvanizing / aluminizing and chemical treatment. In the liquid Zn, Zn-AI, AI-Zn and AI-Si bathes a combined action of corrosion and wear under high temperature and high stress onto the transfer components (rolls) accounts for major economic losses. Most critical here are the bearing systems of these rolls operating in the liquid system. Rolls in liquid system can not be avoided as they are needed to transfer the steel-strip into and out of the crucible. Since several years, ceramic roller bearings are tested here [1.2], however, in particular due to uncontrollable Slag-impurities within the hot bath [3], slide bearings are still expected to be of a higher potential [4]. The today's state of the art is the application of slide bearings based on Stellite\ulcorneragainst Stellite which is in general a 50-60 wt% Co-matrix with incorporated Cr- and W-carbides and other composites. Indeed Stellite is used as the bearing-material as of it's chemical properties (does not go into solution), the physical properties in particular with poor lubricating properties are not satisfying at all. To increase the Sliding behavior in the bearing system, about 0.15-0.2 wt% of lead has been added into the hot-bath in the past. Due to environmental regulations. this had to be reduced dramatically_ This together with the heavily increasing production rates expressed by increased velocity of the substrate-steel-band up to 200 m/min and increased tractate power up to 10 tons in modern plants. leads to life times of the bearings of a few up to several days only. To improve this situation. the Mechanical Alloying (MA) TeChnique [5.6.7.8] is used to prOduce advanced Stellite-based bearing materials. A lubricating phase is introduced into Stellite-powder-material by MA, the composite-powder-particles are coated by High Energy Milling (HEM) in order to produce bearing-bushes of approximately 12 kg by Sintering, Liquid Phase Sintering (LPS) and Hot Isostatic Pressing (HIP). The chemical and physical behavior of samples as well as the bearing systems in the hot galvanizing / aluminizing plant are discussed. DependenCies like lubricant material and composite, LPS-binder and composite, particle shape and PM-route with respect to achievable density. (temperature--) shock-reSistibility and corrosive-wear behavior will be described. The materials are characterized by particle size analysis (laser diffraction), scanning electron microscopy and X-ray diffraction. corrosive-wear behavior is determined using a special cylinder-in-bush apparatus (CIBA) as well as field-test in real production condition. Part I of this work describes the initial testing phase where different sample materials are produced, characterized, consolidated and tested in the CIBA under a common AI-Zn-system. The results are discussed and the material-system for the large components to be produced for the field test in real production condition is decided. Outlook: Part II of this work will describe the field test in a hot-dip-galvanizing/aluminizing plant of the mechanically alloyed bearing bushes under aluminum-rich liquid metal. Alter testing, the bushes will be characterized and obtained results with respect to wear. expected lifetime, surface roughness and infiltration will be discussed. Part III of this project will describe a second initial testing phase where the won results of part 1+11 will be transferred to the AI-Si system. Part IV of this project will describe the field test in a hot-dip-aluminizing plant of the mechanically alloyed bearing bushes under aluminum liquid metal. After testing. the bushes will be characterized and obtained results with respect to wear. expected lifetime, surface roughness and infiltration will be discussed.

  • PDF

($CO_2$ 분해시 $LiMn_2O_4$의 상변화 (Phase Transitions of $LiMn_2O_4$ on $CO_2$ Decomposition)

  • 권태환;양천모;박영구;조영구;임병오
    • 한국응용과학기술학회지
    • /
    • 제20권1호
    • /
    • pp.33-43
    • /
    • 2003
  • $LiMn_2O_4$ catalyst for $CO_2$ decomposition was synthesized by oxidation method for 30 min at 600$^{\circ}C$ in an electric furnace under air condition using manganese(II) nitrate $(Mn(NO_3)_2{\cdot}6H_2O)$, Lithium nitrate ($LiNO_3$) and Urea $(CO(NH_2)_2)$. The synthesized catalyst was reduced by $H_2$ at various temperatures for 3 hr. The reduction degree of the reduced catalysts were measured using the TGA. And then $CO_2$ decomposition rate was measured using the reduced catalysts. Phase-transitions of the catalysts were observed after $CO_2$ decomposition reaction at an optimal decomposition temperature. As the result of X-ray powder diffraction analysis, the synthesized catalyst was confirmed that the catalyst has the spinel structure, and also confirmed that when it was reduced by $H_2$, the phase of $LiMn_2O_4$ catalyst was transformed into $Li_2MnO_3$ and $Li_{1-2{\delta}}Mn_{2-{\delta}}O_{4-3{\delta}-{\delta}'}$ of tetragonal spinel phase. After $CO_2$ decomposition reaction, it was confirmed that the peak of $LiMn_2O_4$ of spinel phase. The optimal reduction temperature of the catalyst with $H_2$ was confirmed to be 450$^{\circ}C$(maximum weight-increasing ratio 9.47%) in the case of $LiMn_2O_4$ through the TGA analysis. Decomposition rate(%) using the $LiMn_2O_4$ catalyst showed the 67%. The crystal structure of the synthesized $LiMn_2O_4$ observed with a scanning electron microscope(SEM) shows cubic form. After reduction, $LiMn_2O_4$ catalyst became condensed each other to form interface. It was confirmed that after $CO_2$ decomposition, crystal structure of $LiMn_2O_4$ catalyst showed that its particle grew up more than that of reduction. Phase-transition by reduction and $CO_2$ decomposition ; $Li_2MnO_3$ and $Li_{1-2{\delta}}Mn_{2-{\delta}}O_{4-3{\delta}-{\delta}'}$ of tetragonal spinel phase at the first time of $CO_2$ decomposition appear like the same as the above contents. Phase-transition at $2{\sim}5$ time ; $Li_2MnO_3$ and $Li_{1-2{\delta}}Mn_{2-{\delta}}O_{4-3{\delta}-{\delta}'}$ of tetragonal spinel phase by reduction and $LiMn_2O_4$ of spinel phase after $CO_2$ decomposition appear like the same as the first time case. The result of the TGA analysis by catalyst reduction ; The first time, weight of reduced catalyst increased by 9.47%, for 2${\sim}$5 times, weight of reduced catalyst increased by average 2.3% But, in any time, there is little difference in the decomposition ratio of $CO_2$. That is to say, at the first time, it showed 67% in $CO_2$ decomposition rate and after 5 times reaction of $CO_2$ decomposition, it showed 67% nearly the same as the first time.

비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰 (Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity)

  • 백승훈;최창혁
    • 대한정형외과 초음파학회지
    • /
    • 제6권1호
    • /
    • pp.1-9
    • /
    • 2013
  • 목적: 상완골 골절에 대한 비확공성 전향적 금속정 내고정술 시행 후, 초음파을 이용하여 회전근 개 상태 및 영향 인자를 객관적으로 평가하고, 초음파 검사의 유용성을 확인하였다. 대상 및 방법: 상완골 골절로 골수강 내 금속정 내고정술을 시행받고 견관절의 초음파 검사를 시행한 17례를 연구 대상으로 하였다. 평균 연령은 $55.7{\pm}18.6$세였으며, 최초 수술 후 평균 추시 기간은 $43.5{\pm}32.2$개월이었다. 전 례에서 술중 회전근개 상태를 확인하였고, 4례(24%)에서 피부절개 후 회전근 개의 파열이 관찰되어 금속 봉합나사못을 이용하여 단열 봉합술을 시행하였다. 임상적 평가는 visual analogue scale (VAS), 운동범위, Korean Shoulder Scoring System (KSS) 및 American Shoulder and Elbow Society (ASES) 점수를 측정하였다. 회전근개의 상태에 대한 초음파 검사를 시행하였고, 견관절 기능에 영향을 미칠 수 있는 방사선학적 유합 시기, 금속정 근위 첨부 돌출 및 근위 교합 나사의 이동을 평가하였다. 금속정 근위 첨부 돌출에 대해서는 방사선학적 검사와 함께 초음파적 검사도 병행하였다. 결과: 최종 추시시 VAS는 평균 $1.65{\pm}1.84$, 운동 범위는 전방 굴곡 평균 $137.0{\pm}33.5^{\circ}$, 외회전 평균 $43.5{\pm}12.7^{\circ}$, 내회전 평균 $16.4{\pm}2.0^{\circ}$이었다. KSS점수는 평균 $79.6{\pm}20.7$점이었으며, ASES점수는 평균 $83.7{\pm}17.0$점이었다. 방사선학적 평가상 전례에서 골유합을 얻었으며, 골유합 기간은 평균 $3.4{\pm}1.3$개월이었으며, 근위 교합 나사의 이동이 6례(35%) 관찰되었다. 견관절 초음파 검사상 회전근 개는 정상 8례(47%), 굴곡변화 4례(24%) 및 부분파열 5례(29%)가 관찰되었으나 완전파열은 관찰되지 않았다. 금속정 첨부 돌출은 방사선 검사상 8례(47%), 초음파 검사상 총 11례(65%)에서 관찰되었고, 고령의 환자에서 호발하였다(p=0.038). 회전근 개의 굴곡 변화 및 부분파열은 첨부 돌출과 관련이 있었으나(p=006), 술전 파열의 봉합여부와는 관련이 없었다(p>0.05). 결론: 금속정 삽입술시 회전근 개 손상을 피하기 위하여 금속정 첨부의 연골하골 내 적절한 함입을 요하며, 초음파를 이용한 경과 관찰은 단순 방사선 검사상 파악하기 곤란한 금속정 첨부의 돌출 및 회전근 개 손상을 확인할 수 있는 유용한 진단 및 평가 도구가 될 수 있을 것으로 판단된다.

  • PDF

산소 치료를 받은 극소저출생 체중아에서 폐 실질변화에 관한 고해상컴퓨터 단층촬영술 소견에 관한 연구 (High-resolution computed tomography findings of lung parenchyme changes in very low birth weight infants treated with oxygen)

  • 진용만;정찬욱;장영표;이영석;이인선
    • Clinical and Experimental Pediatrics
    • /
    • 제50권3호
    • /
    • pp.255-261
    • /
    • 2007
  • 목 적 : 산소치료를 받았던 극소저출생 체중아에서 교정 주령 38에서 42주에 폐 HRCT를 시행하여 폐 실질 내의 변화를 관찰하고 기관지폐이형성증의 임상적 중증도와 비교 하고자 하였다. 방 법 : 산소 치료 받은 재태연령 32주미만, 출생체중 1,500 g미만의 극소저출생 체중아 44명을 대상으로 출생 후 교정주령 38-42주에 폐 HRCT를 시행하였다. 흔히 관찰되는 폐 HRCT 소견들을 기술하고 그들의 빈도를 구했다. 폐 HRCT 소견에서 폐 손상 정도를 정량적으로 표시한 공기폐색 점수, 무기폐 점수, 총 CT 점수와 기관지-폐동맥 직경 비를 기관지 폐이형성증 환아군과 기관지폐이형성증이 없는 환아군 사이에 비교하고, Jobe-Bancalari 진단 기준에 의한 기관지폐이형성증의 임상적 중증도와 비교하였다. 결 과 : 1) 폐 HRCT 소견은 공기 폐색(56.8%), 무기폐(70.5 %), 선상 음영 증가(77.3%), 기관지-폐혈관 다발의 변형(65.9%) 등이 흔히 관찰되었다. 이들 소견들은 기관지폐이형성증이 있는 환아 군에서 기관지폐이형성증이 없는 환아 군에 비해 통계적으로 의미 있게 혼재되어 자주 관찰되었으나(P<0.05), 기관지폐이형성증이 없는 환아 군 일부에서도 관찰되었다. 공기폐색 점수, 무기폐 점수, 총 CT 점수는 기관지폐이형성증이 있는 환아 군에서 기관지폐이형성증이 없는 환아 군에 비해 통계적으로 의미 있게 높았고(P<0.05), 기관지-폐동맥 직경 비는 통계적으로 의미 있게 낮았다(P<0.05). 총 CT 점수(r=0.799, P<0.0001)와 기관지-폐동맥 직경 비(r=0.576, P<0.0001)는 임상적 기관지폐이형성증의 중증도와 통계적으로 의미 있는 직선의 상관관계를 보였다. 결 론 : 산소치료를 받았던 극소저출생 체중아를 대상으로 신생아기에 촬영한 폐 HRCT 소견은 폐 실질 내의 변화를 잘 반영하고, 기관지폐이형성증의 임상적 중증도와 의미 있는 상관관계를 보였다.

세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향 (Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy)

  • 김선영;이두현;조정근;정도형;김호식;최계숙
    • 대한방사선치료학회지
    • /
    • 제18권1호
    • /
    • pp.1-5
    • /
    • 2006
  • 목 적: 세기조절 방사선치료의 환자별 정도관리는 이온전리함을 이용한 일정 지점에서의 절대 선량 측정과 필름을 이용한 상대 선량측정의 두 단계로 구성된다. 이온전리함을 이용한 절대 선량 측정은 동일한 지점에서 치료계획상의 점선량과 실제 측정 점선량 간의 일치도에 대한 정보를 제공한다. 일반적으로 정확한 점선량을 측정하기 위해 volume이 작은 0.015 cc 이온전리함(pin point chamber, PTW, Germany)을 사용하고 있다. 그러나 이 경우 이온전리함의 볼륨이 작아 선량의 오차가 크게 나타나는 경우도 있어, 적합한 볼륨의 이온전리함 사용이 권고되기도 한다. 따라서 볼륨이 다른 세 가지의 이온전리함을 이용하여 점선량을 측정하여 치료계획상의 점 선량과 비교해 보고, 0.015 cc 이온전리함을 이용한 세기조절 방사선치료에서의 절대 점선량 측정의 유효성을 평가해 보고자 한다. 대상 및 방법: 두경부(Head & Neck) 종양의 세기조절 방사선치료가 요구되는 환자 6명을 대상으로 Sliding-window 방법의 IMRT 치료계획을 수립하였으며 치료기는 21EX(Varian, USA) 선형가속기의 6 MV 광자선을 사용하였다. 측정 조건은 120 millenium MLC를 이용하여 Gantry 0도에서 300 MU/min의 선량률로 선원-이온전리함(source-axis-distance)거리를 100 cm, 고체팬텀의 표면으로부터 5 cm 깊이에 이온전리함을 위치시켰다. 치료계획용 컴퓨터(CAD-Plan, USA)에서 결정된 결과를 0.015 cc(pin point, type 31014, PTW, Germany), 0.125 cc(micro type 31002, PTW, Germany ), 0.6 cc(famer type 30002, PTW, Germany) 전리함에 각각 조사하여 측정치를 비교 분석하였다. 측정점은 선량값의 변화가 상대적으로 적은 선량 저변동 영역(Low-gradient area)에 위치시켰다. 결 과: 각각의 이온전리함을 이용하여 측정한 결과 0.015 cc의 경우 평균 ${\pm}0.91%$, 0.125 cc의 경우 ${\pm}0.52%$, 0.6 cc의 경우 ${\pm}0.76%$로 0.125 cc 이온전리함의 경우가 모든 측정조건에서 가장 적은 오차를 보였다. 결 론: 세기조절 방사선치료에 있어서 선량의 평가는 매우 중요하다. 방사선치료가 정밀해지는 만큼 정확한 선량평가가 이루어져야 한다. 점선량을 평가하기 위해 제작된 0.015 cc 이온전리함은 작은 출력신호와 큰 신호 대 잡음비가 절대 선량 측정 시 선량오차를 발생시키는 큰 요인으로 작용할 수 있다. 반면에 이온전리함의 볼륨이 큰 경우 출력신호가 크므로 정확한 선량을 반영할 수 있으나, 작은 측정점에 이온전리함을 정확히 위치시키기 어려워 절대 점선량을 측정하기 어려운 단점이 있다. 따라서 본 연구의 결과에서 본 바와 같이 세기조절 방사선치료의 절대 점선량 측정에는 오차가 상대적으로 적은 0.125 cc 이온전리함의 사용이 고려되어야 한다.

  • PDF

호흡동조 방사선치료용 팬텀의 제작 및 유용성 평가 (Production and Assessing Usefulness of the Moving Phantom for Respiration Gated Radiotherapy)

  • 이양훈;이제희;유숙현
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.135-144
    • /
    • 2010
  • 목 적: 호흡동조 방사선치료용 팬텀 제작을 통해 실시간움직임관리(RPM, Real-time Position Management)에 의한 치료시 호흡에 따른 방사선 조사선량의 적절성을 평가 하고자 한다. 대상 및 방법: 호흡동조 팬텀은 선형 액츄에이터(SCN6-050-50, Dyadic, Japan) 2개, 아크릴판, 지지대, 철판 등으로 팬텀위에 측정 대상을 위치시켜 구동 가능(상 하, 전 후)하도록 제작하였다. 4D CT를 촬영해 환자의 호흡을 분석하여 컴퓨터를 통해 팬텀의 위치와 속도를 제어하여 움직임을 재현하였다. 호흡동조 팬텀위에 2D-Array (PTW)와 4.5 cm의 팬텀(White water 4.5 cm)을 위치하여 21 EX 15 MV X선을 100 Mu, 조사야 $10{\times}10\;cm$의 open field와 2 cm 간격으로 10 cm까지 정방형으로 움직이는 Sliding MLC (DMLC)를 Gantry $0^{\circ}$, $90^{\circ}$에서 팬텀을 (1) 움직이지 않은 경우 (2) 움직인 경우 (3) RPM을 이용하여 동조한 경우(30%)로 나누어 조사하였다. 7.5 cm의 팬텀에 0.125 CC 이온화전리함(PTW)을 위치하여 위와 같은 조건으로 측정하였다. 결 과: 이온화전리함에 의한 중심선량 측정값은 Gantry $90^{\circ}$, $10{\times}10\;cm$ 조사야와 DMLC을 이용한 조사에서 동조시 0.3%이내, 비동조시 약 2%의 오차가 있었다. 2D-Array를 통한 분석시 Gamma index Method (3 mm, 3%)를 적용한 경우 Gantry $90^{\circ}$, $10{\times}10\;cm$ 조사야와 DMLC을 이용한 조사에서 동조시 오차이내, 비동조시 전체 조사야의 약 16% 오차를 보였다. 결 론: 호흡동조 방사선치료용 팬텀의 자체 제작으로 환자 움직임에 의한 치료계획과 방사선 측정으로 인하여 치료시 실제 조사되는 방사선량의 정량적 분석이 가능하였으며, IMRT 환자의 RPM을 이용한 호흡동조 치료시 적절한 평가가 가능하였다.

  • PDF