H$_2$ Gas Sensing Properties of Pt/MoO$_3$ Gas Sensor (Pt/MoO$_3$가스센서의 수소 감지 특성)

  • 최용일;김창교;김진걸;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.118-122
    • /
    • 1996
  • 1wt% Pt/MoO$_3$ gas sensors for detecting H$_2$ gas were fabricated by the pressed pellet method and surface structures of Pt/MoO$_2$ were investigated by TEM and XRD. It was observed that as the calcination temperature is increased, the overlayers of MoO$_3$ on Pt are produced, but the Cl content in PtCl$\_$x/ are decreased. H$_2$ gas sensing properties in N$_2$ ambient and in air ambient were investigated, respectively, and Pt/MoO$_3$ had high sensitivity at low working temp ; 7.8% at 50$^{\circ}C$, 97.7% at 100$^{\circ}C$, 97.1% at 150$^{\circ}C$ when the specimens are treated at 400$^{\circ}C$, and 99.6% at 150$^{\circ}C$ when they are treated at 200$^{\circ}C$. It shows the development of a low-power type sensor is possible by using Pt/MoO$_3$.

  • PDF

Fabrication of NO sensor integrated SiC micro heaters for harsh environments and its characteristics (SiC 마이크로 히터가 내장된 극한 환경용 NO 센서의 제작과 특성)

  • Kim, Kang-San;Chung, Gwiy-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.197-201
    • /
    • 2010
  • This paper describes the fabrication and characteristics of a NO sensor using ZnO thin film integrated 3C-SiC micro heater based on polycrystalline 3C-SiC thin film of operation in harsh environments. The sensitivity, response time, and operating properties in high temperature and voltages of NO sensors based SiC MEMS are measured and analyzed. The sensitivity of device with pure ZnO thin film at the heater operating power of 13.5 mW ($300^{\circ}C$) is 0.875 in NO gas concentration of 0.046 ppm. In the case of Pt doping, the sensitivity of at power consumption of 5.9 mW ($250^{\circ}C$) was 1.92 at same gas flow rate. The ZnO with doped Pt was showed higher sensitivity, lower working temperature and faster adsorption characteristics to NO gas than pure ZnO thin film. The NO gas sensor integrated SiC micro heater is more strength than others in high voltage and temperature environments.

Analysis of Thermal Control Characteristics of VCHP by the Charging Mass of Non-Condensible Gas (불응축가스 주입량에 따른 VCHP의 열제어 특성)

  • Suh Jeong-Se;Park Young-Sik;Chung Kyung-Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1139-1144
    • /
    • 2005
  • This study has been performed to investigate the thermal performance of variable conductance heat pipe (VCHP) with meshed wick. The length of condenser portion in a VCHP is varied by the expansion of inert gas with the operation temperature, and the heat transport capacity is thus varied with the operating temperature. In this study, numerical evaluation of the VCHP is made for the thermal performance of VCHP, based on the diffusion model of inert gas. Water is used as a working fluid and nitrogen as a control inert gas in the copper tube. As a result, the thermal performance of VCHP has been compared with that of constant conductance heat pipe (CCHP) according to the variation of operation temperature. Maximum heat transport capacity of VCHP is mainly presented for operation temperature and the variation of operation temperature is also presented for heat transfer rate of VCHP.

Exhaust-Gas Heat-Recovery System of Marine Diesel Engine (II) - Exergy Analysis for Working Fluids of R245fa and Water - (선박용 디젤엔진의 배기가스 열회수 시스템 (II) - R245fa 및 Water 의 작동유체에 대한 엑서지 분석 -)

  • Choi, Byung-Chul;Kim, Young-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.593-600
    • /
    • 2012
  • The exergy characteristics for R245fa and water working fluids have been analyzed for an electric generation system utilizing the Rankine cycle to recover heat from the wasted exhaust gas from a diesel engine used for the propulsion of a large ship. The theoretical calculation results showed that the efficiencies of exergy and system exergy improved as the turbine inlet pressure increased for R245fa at a fixed mass flow rate. Furthermore, the exergy destruction rates of the condenser and evaporator were relatively larger than those in other components. The exergy efficiency of the system increased with increasing mass flow rate. For a water working fluid, although the exergy destruction rate of the evaporator was similar to that for R245fa, the exergy loss rate varied significantly in response to variations in the pressure and mass flow rates at the turbine inlet.

Thermodynamic Performance Analysis of Ammonia-Water Power Generation System Using Low-temperature Heat Source and Liquefied Natural Gas Cold Energy (저온 열원과 LNG 냉열을 이용하는 암모니아-물 동력 사이클의 열역학적 성능 해석)

  • Kim, Kyoung Hoon;Kim, Kyung Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.483-491
    • /
    • 2014
  • In this study, a thermodynamic analysis was carried out for a combined power generation system using a low-temperature heat source in the form of sensitive energy and liquefied natural gas cold energy. An ammonia-water mixture, which is a zeotropic mixture, was used as the working fluid, and systems with and without a regenerator were comparatively analyzed. The effects of the mass fraction of ammonia and the condensation temperature of the working fluid on the system variables, including the net work production, exergy destruction, and thermal and exergy efficiencies, are analyzed and discussed. The results show that the performance characteristics of the system varied sensitively with the ammonia concentration or condensation temperature of the working fluid. The system without regeneration was found to be better in relation to the net work per unit mass of the source fluid, whereas the system with regeneration was better in relation to the thermal or exergy efficiency.

A Study on the Health Management of Dental Technicians and Their Awareness of the Same (치과기공사들의 건강관리 실태 및 인식수준에 관한 조사 연구)

  • Choi, Un-Jae
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.113-128
    • /
    • 2000
  • The purpose of this study was to serve as a basis for the development of dental technology and for creating a condition that dental technicians could work with pride and right values, by examining what problems there were in their health care, what they thought about them, and how the problems could be solved, The findings of this study were as below: 1. The most serious and harmful element in dental technology workshop was a dust(57.5%) and a noise(33.3%). 2. Approximately 99.0% of the dental technicians investigated made a complain of air pollution caused by noise. Their opinion on a possible measure to remove noise air pollution was that the noise-generating machine should be replaced(64.1%) or that it should be isolated(28.8%). 3. 76.0% complained air pollution cause by dust deteriorates their working efficiency. As a way to eliminate it, they suggested a dust chamber(35.3%) or an air cleaner(27.5%) should be installde. 4. About 80% made a complain of gas air pollution. The most common related symptom was a headache(56.9%). They thought that gas-generating machine should be isolated(39.9%) or that an air purifier should be prepared(33.3%). 5. The largest impact of heat and light on their body was weakening their eyesight(56.9%). 47.1% got burn once though four times, and 34.3% did five times or more. The way to prevent them was to install an automatic casting machine(66.0%) or use protective glasses(28.1%). 6. Approximately 47.7% were considering a change of occupation, and the most common reason was heavy work(23.5%), followed by poor prospect(21.6%) and working environment(19.0%) in the order named. 7. 88.9% responded they were likely to have an occupational disease. Their idea about the proper frequency of regular health examination was once a year(53.6%), or once per every six months(41.8%). 8. The field they were most interested in was health care(39.2%), followed by academic research activities(31.4%). This fact indicated it's most urgently required to improve their working environment.

  • PDF

Working Environment and Risk Assessment of Gasoline in Workplace (Gasoline 취급 사업장의 작업환경 측정 및 위해성 평가)

  • Kim, Hyeon-Yeong
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.1-7
    • /
    • 2014
  • To protect the workers' health, we evaluated the hazards of gasoline which the large amounts of use and lack of information, and perform the risk assessment through the measurement of working environment. It is estimated the reproductive toxicity, and has germ cell mutagenicity class 1B, also IARC 2B, ACGIH A3 with carcinogenicity. With working environment, it is measured as below the TLV-TWA $900mg/m^3$. It is also calculated $0.3mg/m^3$ as carcinogenicity RfC (worker), $2.7mg/m^3$ as chronic inhalation toxicity RfC (worker), $2.7mg/m^3$ as developmental toxicity RfC (worker). From all of these results, it is calculated that the risks are 459, 51 and 51 as carcinogenicity, chronic inhalation toxicity and developmental toxicity, respectively. It is concluded that the risk of gasoline is evaluated over 1.

Preparation of Pt/porous Gold Electrode for CO Oxidation (CO 가스 산화를 위한 백금/다공성 골드 전극의 개발)

  • Shin, So-Hyang;Kim, He-Ro;Oh, Cheon-Seok;Ko, Jae-Wook;Kim, Young-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.4
    • /
    • pp.27-32
    • /
    • 2011
  • Management of gas safety is becoming important with increasing use of gas facilities. U-safety system is being promoted as part of national management of gas, and thus real-time and in-situ gas sensor should be developed. Detection method for When the gas sensor is installed in gas conduit, explosion may be likely, because hydrocarbon gases is usually used the difference of thermal resistance between reference and working electrode. Therefore, it is required to detect the hydrocarbons, such as $CH_4$ and CO, at room temperature via electrochemically catalytic reaction. In this study, Pt nanoparticle was doped on the porous gold powder by electrolytic plating method, and then it was used as catalytic electrode for CO oxidation. For Pt/PAu electrode, approximately 21% of CO conversion was obtained. It is noted that Pt/PAu electrode could be used to react the oxidation of hydrocarbon gases at room temperature via applying of external voltage.

Health Risk Assessment and Analysis on the Volatile Organic Compounds in Some Workplace (모작업장에서 휘발성 유기오염물질의 분석과 근로자들의 건강위해성 평가)

  • Lee, Hyo-Min;Kim, Myung-Soo;Choi, Shi-Nai;Yoon, Eun-Kyung;Park, Jong-Sei
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.530-539
    • /
    • 1997
  • This study was conducted to assess the health risk on the volatile organic compounds such as toluene, xylene, and styrene in painting workplace. It was monitored through personal air sampling during working time in selected 5 workplaces and analysed using gas chromatography. For the settlement of exposure situation, there were regarded working conditions such as working hours, yearly working days, and working years. Also, Monte-Carlo simulation was used for the induction of hazard index using toxicity value from IRIS(Integrated risk information system) database. The results of risk assessment were summarized as follows. 1. The air concentration of toluene was $7.096{\pm}15,644ppm,\;2.586{\pm}4.275ppm\;for\;xylene,\;1.914{\pm}5.320ppm$ for styrene in blast painting workplaces. The level of toluene was different significantly compared with the level of xylene and styrene. 2. Computated chronic daily intake values of 95th percentile on toluene, xylene and styrene treated by Monte-Carlo simulation were 9.616, 3.567, 2.782 mg/kg/day, respectively. 3. Computated hazard index values of 75th percentile on toluene, xylene and styrene treated by Monte-Carlo simulation were 3.5, 1.0 and 1.6, respectively. Adverse health effects on the toluene, xylene and styrene would be expected by working exposure in selected 5 workplaces since the hazard indices of three compounds were exceeded 1 in the surroundings of 75th percentile though having the low emerged frequency.

  • PDF

The Effect of LiBr Concentration on Corrosion of Absorption Refrigeration Systems Using $LiBr-H_2O$ Working Fluids ($LiBr-H_2O$계 흡수식냉동기의 부식에 미치는 LiBr 농도의 영향)

  • Lim Uh Joh;Jeong Ki Cheol
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.33-39
    • /
    • 2001
  • This paper was studied on corrosion behavior of absorption refrigeration systems using $LiBr-H_2O$ working fluids. In the various concentration of lithium bromide solution, polarization test of SS 400, Cu(C1220T-OL) and Al-Ni bronze is carried out. And the corrosion behavior of materials forming absorption refrigeration systems is investigated. The main results are as following: 1) As concentration of lithium bromide solution increases, polarization resistance of materials of each kinds is low. And open circuit potential becomes less noble, the corrosion current density is high drained 2) Open circuit potential of SS 400 is less noble than that of Cu and Al-Ni bronze, corrosion current density of SS5 400 is high drained than that of Cu and Al-Ni bronze. 3) Anodic polarization of Cu and Al-Ni bronze in $62\%$ LiBr solution continues the active state. that of Cu and Al-Ni bronze in the natural sea water maintains the active state and the critical current for passivation appears.

  • PDF