• Title/Summary/Keyword: work improvement

Search Result 3,704, Processing Time 0.036 seconds

Numerical Calculations of IASCC Test Worker Exposure using Process Simulations (공정 시뮬레이션을 이용한 조사유기응력부식균열 시험 작업자 피폭량의 전산 해석에 관한 연구)

  • Chang, Kyu-Ho;Kim, Hae-Woong;Kim, Chang-Kyu;Park, Kwang-Soo;Kwak, Dae-In
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.803-811
    • /
    • 2021
  • In this study, the exposure amount of IASCC test worker was evaluated by applying the process simulation technology. Using DELMIA Version 5, a commercial process simulation code, IASCC test facility, hot cells, and workers were prepared, and IASCC test activities were implemented, and the cumulative exposure of workers passing through the dose-distributed space could be evaluated through user coding. In order to simulate behavior of workers, human manikins with a degree of freedom of 200 or more imitating the human musculoskeletal system were applied. In order to calculate the worker's exposure, the coordinates, start time, and retention period for each posture were extracted by accessing the sub-information of the human manikin task, and the cumulative exposure was calculated by multiplying the spatial dose value by the posture retention time. The spatial dose for the exposure evaluation was calculated using MCNP6 Version 1.0, and the calculated spatial dose was embedded into the process simulation domain. As a result of comparing and analyzing the results of exposure evaluation by process simulation and typical exposure evaluation, the annual exposure to daily test work in the regular entrance was predicted at similar levels, 0.388 mSv/year and 1.334 mSv/year, respectively. Exposure assessment was also performed on special tasks performed in areas with high spatial doses, and tasks with high exposure could be easily identified, and work improvement plans could be derived intuitively through human manikin posture and spatial dose visualization of the tasks.

A Study on the Improvement of Airspace Legislation in Korea (우리나라 공역 법제의 개선방안)

  • Kim, Jong-Dae
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.33 no.2
    • /
    • pp.61-114
    • /
    • 2018
  • Recently airspace became a hot issue considering today's international relations. However, there was no data that could be fully explained about a legal system of korean airspace, so I looked at law and practice about korean airspace together. The nation's aviation law sector is comletely separate from those related to civil and military aircraft, at least in legal terms. The Minister of Land, Infrastructure and Transport shall carry out his/her duties with various authority granted by the "Aviation Safety Act". The nation's aviation-related content is being regulated too much by the Ministry of Land, Infrastructure and Transport's notice or regulation, and there are many things that are not well known about which clauses of the upper law are associated with. The notice should be clearly described only in detail on delegated matters. As for the airspace system, the airspace system is too complex for the public to understand, and there seems to be a gap between law and practice. Therefore, I think it would be good to reestablish a simple and practical airspace system. Airspace and aviation related tasks in the military need to be clearly understood by distinguishing between those entrusted by the Minister of Land, Infrastructure and Transport and those inherent in the military. Regarding matters entrusted by the Minister of Land, Infrastructure and Transpor, it is necessary to work closely with the Minister of Land, Infrastructure and Transport when preparing related work guidelines, and to clarify who should prepare the guidelines. Regarding airspace control as a military operation, policies or guidelines that are faithful to military doctrine on airspace control are needed.

Report on the improvement of the in vitro and specimen reception environment system (핵의학과 검체 접수 환경시스템의 개선사례 보고)

  • Kim, Jung In;Kang, Mi Ji;Kim, Na Kyung;Park, Ji Sol;Kwon, Won Hyun;Lee, Kyung Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.29-34
    • /
    • 2021
  • Purpose Sample reception environment system in nuclear medicine has not changed much compared to 20 years ago. When preparing sample for in vitro test, there was no significant change because the test was carried out by generating an own specimen from the parent specimen. In this study, We would like to introduce a method that automatically removes the sample cap using the automated decapper equipment and enables automatic reception at the same time. In addition, including a provisional reception system. Materials and Methods In 2019, it was intended to get a device that automatically removes the cap of a patient's blood sample. This equipment is the same as the equipment used in the Department of Laboratory Medicine (Vacuette Ⓡ Unicap Belt Decapper, Greiner bio-one, Austria). However, the purchase was delayed due to differences in tube size, budget, and space. In January 2020, we borrowed domestic automatic decapper equipment and modified it to suit our laboratory environment. After 9 months, we were able to introduce a system that automatically removes the lid of a patient's blood sample and at the same time automatically accepts the test. And, through the provisional reception system, it was possible to know the arrival of the specimen in a short time. Results With the use of an automatic decapper device, the sample cap was automatically removed, and the reception proceeded at the same time. So, it was very efficient at work because it shortened the sample preparation time by about 20 minutes. In addition, it was possible to prevent the examiner's musculoskeletal disorders caused by repeated wrist use. After using the provisional reception system, patients were able to be discharged quickly, and the number of phone calls to confirm the arrival of samples was reduced. Conclusion Most hospitals have about four employees in the nuclear medicine in vitro laboratory. It is effective to use automatic decapper equipment and a provisional reception system for organizations that perform work with the minimum number of personnel.

The Efficient Merge Operation in Log Buffer-Based Flash Translation Layer for Enhanced Random Writing (임의쓰기 성능향상을 위한 로그블록 기반 FTL의 효율적인 합병연산)

  • Lee, Jun-Hyuk;Roh, Hong-Chan;Park, Sang-Hyun
    • The KIPS Transactions:PartD
    • /
    • v.19D no.2
    • /
    • pp.161-186
    • /
    • 2012
  • Recently, the flash memory consistently increases the storage capacity while the price of the memory is being cheap. This makes the mass storage SSD(Solid State Drive) popular. The flash memory, however, has a lot of defects. In order that these defects should be complimented, it is needed to use the FTL(Flash Translation Layer) as a special layer. To operate restrictions of the hardware efficiently, the FTL that is essential to work plays a role of transferring from the logical sector number of file systems to the physical sector number of the flash memory. Especially, the poor performance is attributed to Erase-Before-Write among the flash memory's restrictions, and even if there are lots of studies based on the log block, a few problems still exists in order for the mass storage flash memory to be operated. If the FAST based on Log Block-Based Flash often is generated in the wide locality causing the random writing, the merge operation will be occur as the sectors is not used in the data block. In other words, the block thrashing which is not effective occurs and then, the flash memory's performance get worse. If the log-block makes the overwriting caused, the log-block is executed like a cache and this technique contributes to developing the flash memory performance improvement. This study for the improvement of the random writing demonstrates that the log block is operated like not only the cache but also the entire flash memory so that the merge operation and the erase operation are diminished as there are a distinct mapping table called as the offset mapping table for the operation. The new FTL is to be defined as the XAST(extensively-Associative Sector Translation). The XAST manages the offset mapping table with efficiency based on the spatial locality and temporal locality.

Searching for the SCM Improvement Directions through the Power Attribute and Partnership (파워 유형과 파트너십 연계를 통한 공급사슬관리 개선방안 모색)

  • Jung, Dae-Hyun;Park, Kwang-O
    • Management & Information Systems Review
    • /
    • v.35 no.3
    • /
    • pp.57-79
    • /
    • 2016
  • It is required to derive various conclusions by identifying the type of power and the relationship between SCMs and presenting practical implications. Thus, we can identify the differential effects of each type of power on SCM performance. We can contribute to develop the practical implications at more sophisticated multi-dimension by comparing results of this study with various SCM theories. Through previous studies, the source of power is largely divided into binding power and non-binding power. Binding power is classified into behavior coercion, binding reward and relationship legitimacy. Non-binding power is classified into work expertise, information superiority and value compliance. Enterprises should fully understand and recognize partners within supply chains including understanding of the source of power, imbalance and results. Thus, we look into types of power and effects on trust and commitment, and identify a causal relationship leading to collaboration and SCM performance. Specific research results are as follows. First, the binding power did not give a significant effect to the trust. However, the binding power gave a positively(+) significant effect to the commitment. Second, non-binding power showed a significant effect on both trust and commitment. As a result of analysis on total effects, it was shown that non-binding power gave indirect effects to collaboration and SCM performance. Third, it was shown that both trust and commitment significantly affected collaboration. From the perspectives of social exchange theory and trading cost theory among inter-organizational relationship theory, it may lead to SCM performance of trust, commitment and collaboration. Moreover, it was found that association of each attribute of power led to the significant result. Fourth, it was shown that trust and collaboration significantly affected SCM performance. However, commitment did not directly affect SCM performance, but it indirectly significantly affected SCM performance through collaboration. Proper use of this power can firmly build partnerships between members of the supply chain and induce the improvement on supply chain performance and satisfaction of members.

  • PDF

Timing Driven Analytic Placement for FPGAs (타이밍 구동 FPGA 분석적 배치)

  • Kim, Kyosun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.21-28
    • /
    • 2017
  • Practical models for FPGA architectures which include performance- and/or density-enhancing components such as carry chains, wide function multiplexers, and memory/multiplier blocks are being applied to academic FPGA placement tools which used to rely on simple imaginary models. Previously the techniques such as pre-packing and multi-layer density analysis are proposed to remedy issues related to such practical models, and the wire length is effectively minimized during initial analytic placement. Since timing should be optimized rather than wire length, most previous work takes into account the timing constraints. However, instead of the initial analytic placement, the timing-driven techniques are mostly applied to subsequent steps such as placement legalization and iterative improvement. This paper incorporates the timing driven techniques, which check if the placement meets the timing constraints given in the standard SDC format, and minimize the detected violations, with the existing analytic placer which implements pre-packing and multi-layer density analysis. First of all, a static timing analyzer has been used to check the timing of the wire-length minimized placement results. In order to minimize the detected violations, a function to minimize the largest arrival time at end points is added to the objective function of the analytic placer. Since each clock has a different period, the function is proposed to be evaluated for each clock, and added to the objective function. Since this function can unnecessarily reduce the unviolated paths, a new function which calculates and minimizes the largest negative slack at end points is also proposed, and compared. Since the existing legalization which is non-timing driven is used before the timing analysis, any improvement on timing is entirely due to the functions added to the objective function. The experiments on twelve industrial examples show that the minimum arrival time function improves the worst negative slack by 15% on average whereas the minimum worst negative slack function improves the negative slacks by additional 6% on average.

Development of teaching-learning lesson plan untilizing TAI model based on module, used in survey subject of construction department - By applying standard-based assessment system for technical subject (건설계열 측량교과에서 활용할 모듈 기반의 TAI 모형 적용 교수-학습 과정안 개발 - 전문교과 성취평가제를 적용하여)

  • Lee, Ju-Min;Jang, Young-Il;Park, Wan-Shin
    • 대한공업교육학회지
    • /
    • v.38 no.2
    • /
    • pp.89-113
    • /
    • 2013
  • The study started from the point that learners should be basically equipped to quickly respond to changes in demand for future human resources efficiently and effectively, and an attitude to take part in learning voluntarily should thus be cultivated. To this end, the author applied the TAI model based on a module as a class strategy to solve problems related to several classes occurred in specialized high schools. This application of the TAI model was also motivated by the necessity for designing an appropriate teaching-learning method that encourages improvement of self-learning capacity, consistent learning motivation, and willingness rather than external factors. Through this work, the author aims to heighten the interest of learners and improve endurance in learning. The study results are as follows. First, the learning unit was structuralized as a module and then learning stages were proceeded with so that capacity to adapt to learning would improve. The achievement standard (learning goal) was structuralized in a module type by analyzing and reorganizing the textbook considering the link between the actual practice field and a curriculum based on subject characteristics. Through the process of module type learning stages, the student's capacity to ascertain characteristics of units and to adapt to learning both improved. Second, through application of a TAI model based on a module, Self-Directed Learning capacity and capacity to adapt to a new field improved. By applying the module, Self-Directed Learning could be accomplished more effectively than in the existing passive learning environment. By grafting cooperative learning of the TAI model, students had greater interest and achievement in classes, self-confidence and community consciousness, and an opportunity to broaden their thinking. In particular, improvement of self-confidence is effective in cultivating the capacity required in industrial society to transcend the learning of simple functions and knowledge, as well as the capacity to adapt to new environments. Third, by solving tasks focused on fields related to industrial sites, not only actual survey capacity but also additional capacity to identify and solve tasks through various experiences improved. Furthermore, it was helpful for students to have interest and motivation about their own life and learning to cultivate the qualities and capacity to adapt to the working world where new knowledge and technology rapidly change. Fourth, by applying a standard-based assessment system for technical subjects introduced in 2012 to model design for learning plans, clearer and more objective assessment criteria were arranged, and individual learning through instruction at each achievement level could be accomplished. This improved achievement level of individual learners was helpful in reaching achievement goals at specific levels by overcoming the disadvantages of cooperative learning in each group.

Working Conditions, Job Satisfaction and Organizational Commitment of Physical Therapists (물리치료사의 근무실태와 직무만족 및 직장애착)

  • Ahn Soyoun;Kim Won-Joong;Huh Young-Bae
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.308-322
    • /
    • 2002
  • The main objective of this paper is to examine the working conditions of physical therapists and to investigate the level of job satisfaction and organizational commitment under different working conditions. A survey was conducted through structured questionnaire for the physical therapists working in Busan area, and data from 175 therapists were utilized in the final analysis. Survey items included general characteristics of the therapists(sex, age, education, marital status, religion, income, career years, etc.), their working conditions(kinds of organizations they work in, location of PT room, weekly working hours, average number of patients, number of co-workers, equipments/facilities, etc.), and organizational effectiveness measured in terms of job satisfaction and organizational commitment. Major results are as follows: 1) As for the general characteristics of the surveyed physical therapists, male(51.4$\%$) slightly exceeded female(48.6$\%$) and majority(more than 90$\%$) was 20-39 in age. Also, there were more single(57.7$\%$) than married(42.3$\%$), and 54.9$\%$ of the respondents had religion while 45.1$\%$ did not. In terms of the ranks in their organizations, only a few of them(6.9$\%$) were managers, and monthly salary mostly ranged from $\₩$1,000,000 to $\₩$2,500,000. More than half of them worked in various kinds of hospitals, with the remaining in health centers or social welfare institutions. 2) In regard to the working conditions of the respondents, 19.4$\%$ of PT rooms were located in basement areas while the remaining 80.6$\%$ in first to third floors. 34.3$\%$ of them treated 15 patients or less per day, whereas 25.1$\%$ treated 31 patients or more. Also, 52$\%$ recorded physical therapy charts periodically. As for the equipments and facilities, 25.1$\%$ felt 'sufficient' and 40$\%$'insufficient.' 3) The respondents provided various kinds of suggestions for the improvement of their working conditions, where the most important were 'salary raise' and 'reduction of working hours.' In addition, their requests to the PT Association included 'permission of opening of independent practice,' 'permission of legal specialty,' and 'vitalization of the Association.' 4) The comparative analysis of job satisfaction and organizational commitment among different characteristics of the respondents revealed that there was no significant difference between male and female, but in terms of age, the group of 40 or older was highest in both aspects. Besides, therapists who had 15 or more years of hospital career reported higher job satisfaction and organizational commitment than the others. It was also found that the level of organizational commitment increased as the rank of the respondents got higher. There were no significant differences in terms of marital status and religion. 5) Comparison with regard to working conditions showed that therapists employed in university hospitals, health centers and social welfare institutions felt higher job satisfaction and organizational commitment than those in community hospitals and clinics. Also, respondents who worked in basement areas had significantly lower job satisfaction than otherwise. The length of weekly working hours did not really affect the level of job satisfaction, but it was important to maintain 'regular working hours' for the hospitals to improve the employees' organizational commitment. As for the number of patients per day, 'medium level' (21-25 patients) had highest scores in both aspects. And, finally, sufficiency of equipments and facilities was found to be important for the improvement of organizational commitment.

  • PDF

Triple Detector SPECT Imaging with $^{99m}Tc-DMSA$ in Adult Patients with Urinary Tract Infection (성인 요로 감염 환자에서 $^{99m}Tc-DMSA$ 삼중검출기 SPECT 영상의 유용성)

  • Ryu Jin-Sook;Bae, Won-Gyu;Moon Dae-Hyuk;Lee, Myung-Hae;Kim, Soon-Bae,;Park, Su-Kil;Park, Jung-Sik;Hong, Chang-Gi D.;Cho, Kyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.290-298
    • /
    • 1992
  • Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head $^{99m}Tc-DMSA$ SPECT imaging in urinary tract infection. We prospectively performed $^{99m}Tc-DMSA$ planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), $^{99m}Tc-DMSA$ SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of $^{99m}Tc-DMSA$ SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radioligic studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on $^{99m}Tc-DMSA$ SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on $^{99m}Tc-DMSA$ SPECT imaging. Follow-up $^{99m}Tc-DMSA$ SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) $^{99m}Tc-DMSA$ SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. $^{99m}Tc-DMSA$ SPECT is useful as a initial diagnostic tool in adult patients with urinary tract infection. 2) The multiple RCD on $^{99m}Tc-DMSA$ SPECT represent the high probability of irreversible tissue change and need of extensive urological work-up.

  • PDF

Study on the Small Grain Bin for the Improvement of Grain Drying and Storage (곡물건조저장법 개선을 위한 농가용 Grain Bin에 관한 연구)

  • 김성래
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.1
    • /
    • pp.3263-3291
    • /
    • 1974
  • Experimental work of grain bin was carried out to develop the methods of natural air in-bin drying and storage. The method is considered to be more economical, labour saving, and an effective countermeasure to grain loss. To examine the possibility of farm use of the grain bin and to analyze the related factors concerned with in-bin grain drying and storage, ambient air conditions (especially the change of air temperature and relative humidity) and grain quality during drying and storage periods were investigated. A laboratory model bin was constructed to investigate the effect of different forced air conditions on the drying characteristics of rice. In addition, a grain bin with 2.2m diameter and 1.8m height, considered to be the optimum size for the average Korean farm, was constructed and tested to examine the drying and storing characteristics of rice. The weather data analyzed in this study was the nine-year (from 1964 to 1972) record of air temperature and relative humidity in the Suweon area, and the thirty-year (from 1931 to 1960) record of pentad normal relative humidity and air temperature in the Seoul area. From the results of the weather data analyses, the adequate air delivery hours (which was arbitrary defined as the condition to give less than 75% relative humidity) to dry the rice during October were about nine hours (from approximately 10 A.M. to 7 P.M, ) a day, in which the average air temperature was about 15.9$^{\circ}C$ and average relative humidity was 66%. The occurence of days having three hours of such conditions was 1, 2, and 1-day within the 1st, 2nd add last 10-day periods for the month of October, respectively. Therefore, it may be considered that the weather condition in October was satisfactory for the forced natural air drying. The results of the laboratory model bin test were analyzed to obtain the drying curve and drying rate for different drying stages and grain layers in the bin corresponding to various conditions of forced natural air. A drying experiment with a prototype grain bin showed that an approximate 5 percent grain moisture gradient through a 1.6 meter grain deposit was observed after 80 hours of intermittent drying, giving an over dried zone in the lower grain layers and an extremely high grain moisture zone in the upper layers. This indicates that an effective measure should be taken to reduce this high moisture gradient. In order to investigate the drying characteristics of bulk grain in a layerturning operation a grain bin test was performed. This showed a significant improvement of uniform drying. In this test, approximate 107 hours were required to dry a depth of 1.6 meter of grain from an initial moisture content of 22.2 percent to a moisture content of 16.7 percent using an air delivery rate of 2.8 cubic meter per a minute per every cubic meter of grain. This resulted in a 2 percent moisture gradient from the top to the bottom of the bin. During storage period, till the end of June the average temperature of grain was 2~3$^{\circ}C$ higher than ambient air temperature. But during July when the grain moisture content went up slightly (less than 1 percent), the average temperature of the grain also increased to 3~5$^{\circ}C$ higher than ambient air temperature. It is therefore recommended that for safe grain storage, grain should not be stored in sheet metal bins after mid May. From the above results, in-bin rice drying and storage can be used effectively on Korean farms. It is strongly recommended that the use of grain-bin system should be implemented for farm use to improve farm drying and storage of rice.

  • PDF