• Title/Summary/Keyword: wood fire

Search Result 323, Processing Time 0.029 seconds

Hazard Assessment of Combustion Gases from Interior Materials (주요 건축 내장재의 연소가스 유해성 평가)

  • Seo, Hyun Jeong;Son, Dong Won
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.49-56
    • /
    • 2015
  • Toxic gases from five types of interior building materials were investigated according to Naval Engineering Standard (NES) 713. The materials were plywood, indoor wall coverings (wood wall plate members and pine wood), reinforced Styrofoam insulation, laminate flooring, and PVC. Specimens were measured using an NES 713 toxicity test apparatus to analyze the hazardous substances in combustion gas from the materials. We used the US Department of Defense standard (MIL-DTL, Military Standard) to calculate the toxicity index of the combustion gas. Emissions of $CO_2$ from all specimens did not exceed the NES 713 limit of 100,000 ppm. The amount of CO gas emissions from reinforced Styrofoam insulation was 6,098 ppm. 25 ppm and 49 ppm of formaldehyde were released from the reinforced Styrofoam insulation and PVC flooring, respectively. These values were less than the limit of 400 ppm. The highest emissions were from $NO_X$ emitted by plywood and were above the limit of 250 ppm. The toxicity index of the specimens were calculated as 5.19 for plywood, 4.13 for PVC flooring, 2.35 for reinforced Styrofoam insulation, 2.34 for laminate flooring, and 1.22 for indoor wall coverings (pine wood). Our research helps us to understand the properties of these five interior materials by analyzing the combustion gas and explaining the toxicity of constituents and the toxicity index. Also, it would be useful for giving fundamentals to guide the safe use of interior materials for applications.

A Study on Analysis of Characteristics Combustion of Floor Covering Materials (바닥내장재의 연소특성 분석에 관한 연구)

  • Park, Young-Ju;Lee, Hae-Pyeong;Kim, Hyun-Ju
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.77-83
    • /
    • 2010
  • In this study, we analyzed the combustion characteristics of four different floor covering materials(wood, monorium, laminatedpaper, and varnish-laminated paper) with regard to their ignitibility, thermal characteristics and flame retardancy by using an ignition temperature tester, a dual cone calorimeter, a thermogravimetric analyzer and limited oxygen index, for their fire risk assessment. According to the result, monorium had the lowest ignition temperature of $325^{\circ}C$ and the laminated paper and the varnish-laminated paper promptly ignited before 7s. Further, the wood showed the largest total heat release of $100MJ/m^2$, and the varnish-laminated paper showed the highest peak heat release rate. From the thermogravimetric analysis, it was shown that all specimens underwent rapid weight loss at $300{\sim}400^{\circ}C$. The limit oxygen indices of the laminated paper and the varnish-laminated paper were in the range of 20~21%, while it was 34% for wood. This study enabled us to confirm that wood, laminated paper and varnish-laminated paper have a relatively short ignition time and are easy to burn but they all have low heat release. In contrast, wood showed the lowest fire risk among them and had excellent flame retardancy but with high heat release.

The Control System of Wood Pellet Boiler Based on Home Networks (홈 네트워크 기반의 펠릿 활용 난방 보일러 제어시스템)

  • Lee, Sang-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • This paper presents the implementation of a control system of pellet boiler using wood pellet as carbon neutral material. The system also has the additional features to provide remote controlling and monitoring based on home networking technology through either public switched telephone networks or mobile communication networks. It consists of three kinds of sub-modules; a main controller provides basic and additional features such as a setting of temperature, a supplying of wood pellet, a controlling of ignition and fire-power, and a removing of soot. The second is temperature controller of individual rooms which is connected to the main controller through RS-485 links. And interface modules with PSTN and mobile networks can support remote controlling and monitoring the functions. The test results under the heating area of $172m^2$ show a thermal efficiency of 93.6%, a heating power of 20,640kcal/hr, and a fuel consumption of 5.54kg/hr. These results are superior to those of the conventional pellet boilers. In order to obtain the such high performance, we newly applied a 3-step ignition flow, a flame detection by $C_dS$ sensor, and a fire-power control by fine controlling of shutter to our pellet boiler.

Analysis of Fire Occurrence Characteristics According to Ignition Heat Sources (발화열원에 따른 화재발생 특성 분석)

  • Lee, Kyung-Su;Kim, Tae-Hyeung;Lee, Jae-Ou
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.280-289
    • /
    • 2022
  • Purpose: In this study, the characteristics of fire occurrence according to ignition heat sources such as operating equipment, cigarette/lighter fire, and flame/fire were analyzed. Method: One-way ANOVA and cross-analysis were used to analyze the characteristics of fire occurrence by verifying the difference between the ignition environment, fire damage status and scale, and cause of ignition according to the ignition heat source. Result: The fire occurrence characteristics were analyzed through As a result of the analysis, it was found that fires caused by operating devices occurred more frequently on weekdays than other ignition heat sources, and the number of victims and the number of victims were the highest, so mobilization of firefighting power and property damage were the greatest. The initial ignition was generated by electric and electronic devices, and the combustion was expanded by the synthetic resin. For fires caused by cigarette and lighter fires, the most fires occurred on Saturdays and Sundays, and the mobilization of the police force was more characteristic than the mobilization of the firefighting force. In particular, it was found that the initial ignition and combustion expansion were caused by paper, wood, and hay. Fires caused by sparks and sparks occurred most frequently on Saturdays and Sundays, and initial ignition and combustion expansion were found to be caused by paper, wood, and hay. In particular, it showed the characteristic that it occurred in the place farthest from the fire station. The common characteristic of all ignition heat sources was that the fire occurred most frequently in the afternoon time, and the fire type was predominantly the building structure fire, and only the ignition point was burned the most. Conclusion: In order to prevent fire and minimize damage, it is necessary to analyze the tendency of fire occurrence and to prepare appropriate preparations according to the fire occurrence factors. In order to analyze the characteristics of fire occurrence using public data in the future, it is necessary to standardize disaster data and to open and activate data.

Rating Evaluation of Fire Risk for Combustible Materials in Case of Fire (화재 시 연소성 물질에 대한 화재 위험성 등급 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.75-82
    • /
    • 2021
  • This study investigated the fire risk assessment of woods and plastics for construction materials, focusing on the fire performance index-III (FPI-III), fire growth index-III (FGI-III), and fire risk index-IV (FRI-IV) by a newly designed method. Japanese cedar, red pine, polymethylmethacrylate (PMMA), and polyvinyl chloride (PVC) were used as test pieces. Fire characteristics of the materials were investigated using a cone calorimeter (ISO 5660-1) equipment. The fire performance index-III measured after the combustion reaction was found to be 1.0 to 15.0 with respect to PMMA. Fire risk by fire performance index-III increased in the order of PVC, red pine, Japanese cedar, and PMMA. The fire growth index-III was found to be 0.5 to 3.3 based on PMMA. Fire risk by fire growth index-III increased in the order of PVC, PMMA, red pine, and Japanese cedar. COpeak concentrations of all specimens were measured between 106 and 570 ppm. In conclusion, it is understood that Japanese cedar with a low bulk density and PMMA containing a large amount of volatile organic substances have a low fire performance index-III and high fire growth index-III, and thus have high fire risk due to fire. This was consistent with the fire risk index-IV.

The model development and verification for surface branch wood fuels moisture prediction after precipitation during spring period at the east coast region (영동지역 봄철 소나무림에서 강우후 지표연료 직경별 연료습도변화 예측모델 개발 및 검증)

  • Lee, Si-Young;Lee, Myung-Woog;Kwon, Chun-Geun;Yeom, Chan-Ho;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.434-437
    • /
    • 2008
  • In this study, we developed a fuel moisture variation prediction model on each day after precipitation during a spring forest fire exhibition period. For this research, we selected plots in pine forest on Sam-Chuck si and Dong-hae si in Kangwon do according to a forest density(low, mediate, high) and classified a surface woody fuel by a diameter.(below 0.6cm, $0.6{\sim}3cm$, $3{\sim}6cm$, and above 6cm). A validity of this model was verified by applying a fuel moisture variation after precipitation in this spring. In the result, $R^2$ was $0.76{\sim}0.92$. This model will be a useful for improvement of a forest fire danger rate forcast through a prediction a fule moisture in forest.

  • PDF

Feasibility Analysis of a Wood Bioenergy System in an Apartment Complex (목질계 바이오에너지 시스템의 공동주택 적용성 평가)

  • Ko, Myeong-Jin;Choi, Mi-Young;Choi, Doo-Sung;Chang, Jae-Dong;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.81-88
    • /
    • 2010
  • This study compared the feasibility of utilizing a wood bioenergy system over a conventional central heating and cooling system and a cogeneration system in an apartment complex. The performance of the three systems were compared in the following areas: energy consumption, environmental impact(output of CO2, CH4, and N2O), and life cycle cost. The results showed that energy performance of the wood bioenergy system was similar to the conventional central system (just a 1% improvement) but the cogeneration system showed a 12% reduction in energy consumption compared to the conventional system. In terms of environmental impact, the bioenergy system reduced pollutants by 50% while the cogeneration system reduced pollutants by 30% compared to the conventional system. Life cycle cost analysis indicated bioenergy and cogeneration to have an 8% and 19% improvement over the conventional system. The findings of the study suggest that it is both economically and environmentally beneficial to use a wood bioenergy system in place of a conventional central heating and cooling system in apartment complexes.

Hazard Assessment of Explosion in Suspended Dust of Wood (목재 부유분진의 폭발 위험성 평가)

  • Lee, Keun Won;Lee, Su-Hee;Han, Ou-Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.81-86
    • /
    • 2013
  • Accidents of dust explosion has been occurred in various industries as a plastics, pharmaceuticals, timber, grain storage, solid fuels and chemicals. In this study, the silo dust, hammer mill dust and Nyusong dust in the manufacturing process of the particle board to utilize west wood, which were selected for this experiment and were evaluated the characteristics of dust explosion. The explosion characteristics such as a maximum explosion pressure, explosion index, lower explosive limit, and minimum ignition energy in suspended dust of the wood by Siwek 20 L apparatus were measured and evaluated for the experiment. The results of this study can be used the process safety measures to prevent accidents of fire and explosion in the suspended dust of wood.

A Study on the Combustion Characteristics of Useful Imported Wood for Building Materials - Focusing on the North American species (Douglas-fir, Western Red cedar) and African species(Makore, Padauk, Bubinga) - (국내 유용 건축자재용 수입 목재의 연소특성에 관한 연구 - 북미 산재(Douglas-fir, Western Red cedar)와 아프리카 산재 (Makore, Padauk, Bubinga)를 중심으로 -)

  • Seo, Hyun Jeong;Baek, Jong Kyo;Lee, Min Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.8-14
    • /
    • 2017
  • This study examined the combustion and thermal characteristics of imported woods for building materials in Korea. Wooden specimens were confirmed by a cone calorimeter according to the KS F ISO 5660-1 standard. The combustion properties of the wooden specimens were measured in terms of the heat release rate (HRR), total heat released (THR), mass lose rate (MLR), and ignition time (time to ignition; TTI). The optical microscope was used for determine the anatomical characteristics of wood pit and structure. Also, the thermal properties were measured by thermogravimetric analysis (TGA) to determine the thermal stability of wooden specimens. The result of this experiment would be useful for fundamentals of guiding the combustion properties and thermal stability using wood application.

Development of Ventilator without Power using Air Flow (공기흐름을 이용한 무동력 환풍장치 개발)

  • Kim, Bum-Suk;Kwon, Taek-Joo;Jeong, Ji-Hyun
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.26-31
    • /
    • 2016
  • The studies on the efficient ventilator to reduce fire and save energy have been proceeded actively. The purpose of this paper is to design a ventilator used in residential wood stove. The ventilator consists of rotation and support part, and it is operated by natural wind without power. The shape of rotation part of the ventilator is like airfoil to reinforce pressure drop. We designed direction controller for the rotation part to track the direction of wind continuously. The rotation and support part have point-contact each other to minimize a friction. We verify the properties of the proposed ventilator though simulation and experiment. The results show the proposed ventilator can exhaust safely combustion gas of the stove more than other ventilator.