• 제목/요약/키워드: wood fire

검색결과 325건 처리시간 0.021초

합판(合板)의 내화처리(耐火處理)에 관(關)한 연구(硏究) - III. 제1인산(第一燐酸)암모늄처리합판(處理合板)의 내화도(耐火度) (Studies on Plywood Treated Fire-Retardant - III. The Fire-Retardant Degree of Monoammonium Phosphate Treated Plywood)

  • 김종만
    • Journal of the Korean Wood Science and Technology
    • /
    • 제14권4호
    • /
    • pp.21-28
    • /
    • 1986
  • Plywood used for construction as a decorative inner material is inflammable and can fire accident, causing destruction of human life and property. In this study, 3.5mm Kapur plywoods were soaked in the 23% monoammonium phosphate solutions by cold soaking method 3, 6, 9hrs and hot-cold bath method for 3/3hrs, and redrying was carried out by press-drying at the platen temperature of 110, 130, 160, 180$^{\circ}C$, and then fire test was carried out to investigate burning point, flame exhausted length, frame spread length, back side carbonized area and weight loss. The results are as follows; 1. In cold soaking method for 3, 6, 9hrs. retentions of monoammonium phosphate were 0.377, 0.448, 0.498kg/(30cm)$^3$ respectively, and in hot-cold bath method for 3/3hrs, the retention was 1.331kg(30cm)$^3$ that exceeded the minimum retention 1.124kg/(30cm)$^3$. 2. Correlation coefficients among the variable were shown in table 2. From the table, it could be recognized that there were close negative correlations between the treatment and burning point, flame spread length, back side carbonized area, flame exhausted time and weight loss, and there was negative correlation between treating time and back side carbonized area, but there was positive correlation between platen temperature and burning point. 3. From table 3, it can be observed that there were highly significant differences for burning point, flame spread length, flame exhausted time, back side carhonized area, weight loss between treatments. And in 2-way interactions, there were also highly significant for burning point, flame spread length, flame exhausted time, weight loss between time x treatment. 4. It was observed that burning point, flame exhausted time, flame spread length, back side carbonized area, and weight loss in fire-retardant treated plywood were the best effects in fire-retardant treated plywood, water treated plywood and nontreated plywood. In conclusion, I can estimate that absorbed chemical contents by hot-cold bath method for 3/3hrs, have a lot of effects on fire-retardant factors such as burning point, flame spread length, flame exhausted time, backside carbonized area and weight loss, but platen temperatures have a little effects on the fire factors.

  • PDF

자연 건조된 굴참나무와 느티나무 목재의 연소성(II) (Combustion Properties of the Quercus variabilis and Zelkova serrata Dried at Room Temperature (II))

  • 정영진;진의
    • 공업화학
    • /
    • 제21권4호
    • /
    • pp.469-474
    • /
    • 2010
  • 목재는 연소성이 높은 본질적인 결함을 가지고 있다. 본 연구의 목적은 자연 건조된 굴참나무와 느티나무의 연소성질을 시험하였다. 열방출율과 CO/$CO_2$ 발생과 연기차폐와 같은 연기지수를 콘칼로리미터(ISO 5660-1)를 이용하여 측정하였다. $50kW/m^2$의 외부 열유속하에서 굴참나무의 총 방출열량, THR ($140.2MJ/m^2$)은 느티나무의 THR ($85.7MJ/m^2$) 과 비교하여 높게 나타났다. 그리고 굴참나무의 총 연기발생량, $TSP3.50m^2$는 느티나무의 $TSP0.65m^2$에 비하여 높게 나타났다. 이들 결과는 시험목의 체적밀도에 의존함을 보여준다. CO/$CO_2$ 발생비는 굴참나무와 느티나무가 각각 0.053, 0.043을 나타내었다. 또한 느티나무가 굴참나무에 비해 숯생성으로 인한 증대된 연소 억제성을 보여주었다.

구조용(構造用) 내화처리(耐火處理) 합판(合板)의 재건조(再乾燥)에 관(關)한 연구(硏究) (Redrying Fire - Retardant - Treated Structural Plywood)

  • 이필우;이.엘,샤풔
    • Journal of the Korean Wood Science and Technology
    • /
    • 제9권4호
    • /
    • pp.1-21
    • /
    • 1981
  • 미송(美松) 및 포푸라 내수합판(耐水合板)을 내장용내화제(內裝用耐火劑)로 가압처리한 다음 저온(低溫), 중온(中溫) 및 고온건조상태(高溫乾燥狀態)에서 재건조(再乾燥)를 실시(實施)하였다. 붕사(硼砂)-붕산(硼酸), 크롬화(化) 염화아연, 미나리스, 파이레소오트 및 일종(一種)의 상업용(商業用) 내화제(耐火劑)로 내화처리(耐火處理)를 실시(實施)하였다. 건조방법(乾燥方法)은 키른건조(乾燥)와 열판건조(熱板乾燥)를 적용(適用)하였으며 건조속도(乾燥速度)와 건조결함(乾燥缺陷)에 관하여 검토(檢討)하였다. 붕사(硼砂)-붕산(硼酸)은 수분처리합판(水分處理合板)과 유사(類似)한 건조속도(乾燥速度)를 나타내었으나 기타(其他)의 내화제(耐火劑)는 일층(一層) 늦은 건조속도(乾燥速度)를 나타내었고 더 많은 건조결함(乾燥缺陷)을 일으키는 경향(傾向)이 있었다. 특(特)히 크롬화(化) 염화아연은 가장 건조속도(乾燥速度)가 느렸으며 가장 많은 건조결함(乾燥缺陷)을 일으키는 경향(傾向)이 있었다. 열판건조(熱板乾燥)는 키른 건조(乾燥)와 비교(比較)하여 같은 온도수준(溫度水準)에서 삼배(三倍)나 더 빨리 건조(乾燥)하였으나 열판압력을 50 $1b/in^2$(3.52$kg/cm^2$)를 적용(適用)하였기 때문에 두께 수축율(收縮率)은 이배(二倍)를 나타내었다.

  • PDF

제2인산(第二燐酸) 암모늄에 의(依)한 합판(合板)의 내화처리(耐火處理)(II) - 열판온도(熱板溫度)가 처리합판(處理合板)의 곡강도(曲强度)에 미치는 영향(影響) - (Fire Retardant Treatment to the Plywood with Di-ammonium Phosphate [(NH4)2HPO4] (II) - Effect of Platen Temperature on Bending Strength of Treated Plywoods -)

  • 정우양;이필우
    • Journal of the Korean Wood Science and Technology
    • /
    • 제12권2호
    • /
    • pp.3-9
    • /
    • 1984
  • This study was carried out to examine the practicality of DAP[$(NH_4)_2HPO_4$] as fire retardant for plywood by static bending test the redried plywoods which had been soaked in 20% $(NH_4)_2HPO_4$ solution. Being hot/cold soaked in the solution for 3/3, 6/3, 9/3 and 12/3 hours and redried by cyclic press-drying method at the platen temp. of 130, 145, 100 and $175^{\circ}C$, the treated plywoods were tested to offer the mechanical data, that is, $S_{pl}$(stress at proportional limit), MOE(modulus of elasticity), MOR(modulus of rupture) and $W_{pl}$(work per unit volume to proportional limit ) in flexure. The results obtained were summarized as follows. 1. $S_{pl}$ of fire retardant treated plywoods ("FRP" would be used hereinafter) decreased as the platen temperature increased, but it was superior to that of non-treated plywoods(Control) at $160^{\circ}C$ or higher. 2. MOE of FRP decreased roughly with the increase of temperature, hut this tendency was not constant. And the value of FRP was higher than that of Control even at $175^{\circ}C$. 3. MOR of FRP showed same temperature-dependent tendency as MOE, but it was influenced more sensitively at the higher temperature. 4. $W_{pl}$ of FRP also decreased gradually with the increase of platen temperature and the value in DAP 9/3 treatment was Jess than 70% of control plywoods. 5. In view of redrying time and mechanical properties, the most reasonable platen temperature for DAP treated FRP was $160^{\circ}C$ in this study.

  • PDF

실온에서 건조된 리기다 소나무와 밤나무의 연소특성 (Combustion Chracteristics of the Pinus rigida and Castanea savita Dried at Room Temperature)

  • 정영진;진의
    • 한국화재소방학회논문지
    • /
    • 제24권3호
    • /
    • pp.86-92
    • /
    • 2010
  • 건자재로서 나무 결함중의 하나는 화재에 대한 취약성이다. 본 연구의 목적은 한국에서 자란 리기다 소나무와 밤나무의 연소성질을 시험하는 것과 건자재로서의 사용에 대한 바람직한 특성을 알아내는 것이다. 콘칼로리미터(ISO 5660-1)는 열방출율과 CO, $CO_2$ 발생과 연기차폐와 같은 연기지수를 측정하는 데 이용되었다. $50kW/m^2$의 외부 열유속하에서 밤나무의 평균열방출율($HRR_{mean}$)은 소나무의 평균열방출율 $68.5kW/m^2$과 비교하여 $70.4kW/m^2$을 나타내었다. 게다가 총열방출율(THR)은 밤나무($120.8MJ/m^2$)가 소나무($81.9MJ/m^2$)보다 높게 나타났다. 이들 결과는 시험된 나무종의 체적밀도에 의존된다. 밤나무는 소나무에 비하여 높은 $CO_{mean}$ 수율과 높은 CO/$CO_2$ 수율을 나타내었다.

폴리인산염 첨가에 의한 폴리프로필렌 기반의 Wood Plastic Composites 열안정성 (Thermal Stability of Polypropylene-Based Wood Plastic Composites by The Addition of Ammonium Polyphosphate)

  • 전상진;이선영
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권6호
    • /
    • pp.682-690
    • /
    • 2014
  • 본 연구에서는 WPC의 열안정성을 향상시키기 위해 폴리프로펠렌 매트릭스에 목분과 폴리인산염(ammonium polyphosphate, APP)의 삼종혼합 후, 목분과 난연제 첨가에 따른 목재플라스틱 복합재(wood plastic composites, WPC)의 열분해 거동이 조사되었다. 모든 배합비의 WPC 열분해 거동은 질소의 환경에서 분당 $10^{\circ}C$ 상승속도로 제어하여 열중량분석기(Thermogravimetric analyzer)를 통해 분석하였다. 목분의 열분해온도가 PP의 열분해온도 보다 낮기 때문에 목분에 의해 생성된 char막은 PP로의 열전달 속도를 낮추며, 2차 열분해온도 증가 및 열분해속도를 늦춘다. APP를 첨가한 WPC의 경우 1차 열분해온도 감소 및 2차 열분해온도의 증가를 보여준다. 목분의 함량이 높은 WPC의 경우, APP 첨가 시 1차 열분해온도 감소 및 2차 열분해속도가 증가하였고, 고온에서 잔여물의 양은 APP 함량이 증가할수록 크게 증가하였다. APP가 첨가된 WPC 경우, 목분의 함량이 10 wt%에서 50 wt%로 증가 시 고온에서 잔여물 양이 증가하였는데, 이는 APP 및 목질섬유의 char화가 동시에 발생되기 때문으로 보이며 결과적으로 목분 함량이 증가할수록 APP의 효과가 높게 나타나 열안정 효과를 관찰할 수 있었다.

도료의 주성분에 따른 편백 합판의 방염성능 비교 분석 (Comparative Analysis of Flame Retardant Performance of Japanese Cypress Plywood Based on the Main Ingredients of Fire Retardant Paint)

  • 임수희;공하성
    • 대한안전경영과학회지
    • /
    • 제25권1호
    • /
    • pp.61-66
    • /
    • 2023
  • The purpose of this study is to compare and analyze the flame retardant performance of Japanese cypress(Chamaecyparis obtusa) plywood, commonly used in indoor decoration, furniture, and tableware, by treating it with three different fire retardants with different primary ingredients. The experiment was conducted in compliance with Article 31, Paragraph 2 of the Enforcement Decree of the Fire Facilities Installation and Management Act and Articles 4 and 7-2 of the Flame Retardant Performance Standards. After flame time, after glow time, char length, and char area were measured. As a result, first, after flame time was measured at 0 seconds regardless of whether the flame retardant treatment was applied. Second, after glow time was relatively long, measuring 22.7 seconds without treatment, which is likely due to the weak fire resistance and high concentration of carbon monoxide generated by the chemical characteristics of the Japanese cypress itself. Third, it was confirmed that the effects of the primary ingredient, phosphorus, in the flame retardant treatment varied depending on the technological development of the manufacturers of the same species of Japanese cypress plywood. In the future, it is expected that the results of this study will provide fundamental data to select flame retardant treatments that show high flame retardant performance according to the botanical characteristics of the wood.

내화약제(耐火藥劑)의 처리방법(處理方法) 및 처리단판(處理單板)의 조판형태(調板形態)가 합판(슴板)의 성능(性能)에 미치는 영향(影響) (Effects of Treatment Methods of Fire-retardant and Layup of Treated Veneers on the Performances of Plywoods)

  • 손정일;조재성;서진석
    • Journal of the Korean Wood Science and Technology
    • /
    • 제27권3호
    • /
    • pp.39-50
    • /
    • 1999
  • 라디에타소나무, 케루잉, 딜레니아, 터미날리아 및 칼로필롬 단판에 내화약제로서 20% 제2인산암모늄 수용액을 상압 침지 및 진공가압침지 처리한 시험을 실시 하였으며, 라디에타소나무와 케루잉 단판의 구성형태와 내화약제의 침지처리 조건들을 여러형태로 조합한 합판을 요소 멜라민 수지와 페놀수지 접착제를 사용하여 제조하였다. 결과, 라디에타소나무가 케루잉보다 약제보유도 및 처리효과가 뛰어났으며, 진공가압침지가 상압침지보다 약제보유면에서는 유효하였다. 그리고, 기계적 성질에 있어 단판첨지법으로 내화처리를 하여 제조한 합판이 반드시 접착력 및 휨강도적 성질의 저하를 가져오지는 않았으며, 내화성에 있어서는 요소 멜라민수지 접착이 우수한 성능을 보였다. 결과적으로, 접착 강도성능과 내화성능을 고려한 단판 수종의 적정한 선택, 층간구성(조합) 및 교호약제처리가 실제 사용시 가능할 것이다.

  • PDF

건물 화재 시 LPG소형저장탱크 보호용 화재 저항 재료 성능 실증 (Experimental validations of fire-resistant materials for protecting LPG small storage tank from building fires)

  • 김승환;김경식;허승건;이재훈
    • 한국가스학회지
    • /
    • 제24권4호
    • /
    • pp.18-24
    • /
    • 2020
  • 본 연구의 목적은 화재사고가 발생한 건물에 인접한 LPG 탱크용 방화벽의 적용성을 검증하는 것이다. 제안된 방화벽 재료는 (1) 두께 10 mm 목재합판, (2) 내화도료를 도포한 목재합판, (3) 두께 75 mm Expanded Polystyrene, (4) 두께 75 mm 유리섬유 충진 샌드위치 판넬, (5) 두께 75 mm Autoclave Lightweight Concrete이다. 화원은 1 m 정사각형으로 120-140 g/s의 LPG를 균일하게 분사하여 방화벽과 후단의 탱크를 가열한다. 적용성은 시험 후 방화벽의 구조적 건전성 확인, 방화벽 양면 및 탱크표면 온도, 탱크 인근 복사열을 분석하여 판단한다. 그 결과, ALC 방화벽이 유일하게 구조 건전성을 유지하였고 저장탱크 온도를 가작 적게 상승시켜 폭발 방지 적용성을 확인하였다. 본 실험결과를 활용하여 방화벽의 성능평가 기준 마련에 필요한 핵심인자를 도출하였다.