• 제목/요약/키워드: wood fire

검색결과 323건 처리시간 0.025초

Fire Performance of the Wood Treated with Inorganic Fire Retardants

  • Son, Dong-Won;Kang, Mee-Ran;Kim, Jong-In;Park, Sang-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • 제40권5호
    • /
    • pp.335-342
    • /
    • 2012
  • To prepare the eco-friendly fire retardant wood, Japanese red pine (Pinus densiflora), Hemlock (Tsuga heterophylla), and Radiata pine (Pinus radiata) were treated with inorganic chemicals, such as sodium silicate, boric acid, ammonium phosphate, and ammonium borate. Different combination and concentration of those chemicals were impregnated by vacuum/pressure treatment methods. The electron-beam treatment was used to increase the chemical penetration into the wood. The fire performance of the fire retardant treated wood was investigated. The penetration of chemicals into the wood was enhanced after electron beam treatment. Ignition time of the treated wood was the most effectively retarded by sodium silicate, ammonium phosphate, and ammonium borate. The most effective chemical combination was found at 50% sodium silicate and 3% ammonium borate, which satisfied flammability criteria for a fire retardant material in the KS F ISO 5660-1 standards.

Survey on the Utilization of Fire-Wood Boiler using Woody Biomass in Gangwon Province

  • Cha, Du-Song;Oh, Jae-Heun;Yi, Jae-Seon;Bae, Young-Soo
    • Journal of Forest and Environmental Science
    • /
    • 제23권2호
    • /
    • pp.79-85
    • /
    • 2007
  • This survey was carried out to investigate the utilization situation of fire-wood boiler by the questionnaire and personal interview on rural and mountain households of Gangwon province from 1998 to 2005. The questionnaire include 7 questions on installation, 7 questions on fuel, 3 questions on use, and 3 questions on improvement. Each question was analyzed by percentage to investigate the use situation. This survey indicated that the general problems in use of fire-wood boiler are fuel purchase, collection and transportation, that the development of the household heating boiler using wood-based forming fuel which is cheap, small volume, easy handling, convenient purchase and high heat efficiency could be an alternative to improve the problems and that the continuous expansion of the supply of fire-wood boiler can prevent the devastation of forest through the regulation of imprudent fuel supply. Although the financial aid plan on the installation of fire-wood boiler is in active, many petty households in rural and mountain areas lose a chance to install the fire-wood boiler due to the unsatisfactory information. Thus, it will be desirable for municipal government to prepare the information plan to offer the equal chance and condition to all households in rural and mountain areas and to increase the financial aid for the continuous supply of fire-wood boiler.

  • PDF

전원주택의 벽난로와 관련된 화재사례의 분석 (A Case Study on Fire Investigation for a Wood-Burning Stove in an Idyllic House)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.119-128
    • /
    • 2015
  • 이 논문에서는 신축 후 약 2년이 경과한 전원주택에서 벽난로 가동 중에 벽난로로 인한 화재가 발생하여 전소된 사례에 대해 법원을 통해 소방서, 경찰서, 화재보험관련 조사기관, 주택을 시공한 건설회사와 벽난로를 시공한 벽난로제조업체로부터 제공받은 자료들을 분석하여 벽난로 옆 벽체의 목재기둥에 남아 있는 저온장기발화의 화재패턴을 근거로 벽난로 옆 벽체의 목재기둥에 벽난로 화실(火室)의 열이 전도되어 화재가 발생하였음을 입증하였다. 그리고 벽난로 옆의 목재기둥이 저온장기발화를 한 이유는 굴뚝에 환기를 위한 공기창을 설치하지 않았기 때문임을 화재시뮬레이션을 통해 입증하였다.

Hygroscopic Property, Leaching Resistance and Metal Corrosive Efficacy of Wood Treated with Fire Retardants

  • Son, Dong Won;Kang, Mee Ran;Hwang, Won Joung;Lee, Hyun Mi;Park, Sang Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권2호
    • /
    • pp.157-162
    • /
    • 2014
  • This study was conducted to examine the functionality of the fire retardant treated wood. The hygroscopic property, leaching resistance, metal corrosive efficacy and gas toxicity of retardant treated wood were analyzed. Sodium silicate was penetrated to the wood for making fire retardant treated wood. The subsequent treatment agents such as boric acid, ammonium borate, di-ammonium phosphate were treated after sodium silicate treatment due to fixation. As results for the test, the leaching resist was improved by subsequent treatment. The fire retardant combination such as sodium silicate, boric acid and di-ammonium phosphate showed high hygroscopic property, metal corrosive efficacy. The gas toxicity was also satisfied KS standard.

Characterization of Burned Architectural Woods by Fire Using SEM-EDXS and Computerized Tomography

  • Lee, Hyun-Mi;Hwang, Won-Joung;Lee, Dong-Heub;Son, Dong-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권5호
    • /
    • pp.516-522
    • /
    • 2014
  • Old architectural wood materials damaged by a fire were evaluated on the basis of wood species and scanning electron microscopy (SEM) observation of wood tissues in combination with energy dispersive X-ray spectroscopy (EDXS) analysis. Results of SEM observation showed that tracheid wall thickness of burned parts was very thin compared with undamaged and sound wood, and tylosoid in the resin canals disappeared after the exposure to fire. SEM-EDXS analysis indicated that carbon and oxygen peaks occurred in the original energy band, and the carbon peak was higher than that of the oxygen in the burned part. A computerized tomography was also undertaken to investigate the carbonization layer formed by fire and possible internal defects.

건축용 난연 목재 개발에 대한 실험 연구 (An Experimental Study on the Development of Fire-retardant Treated Wood for Construction)

  • 서현정;김남균;조정민;이민철
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.149-156
    • /
    • 2017
  • This study investigates fire-retardant performances and combustion/thermal characteristics of fire-retardant treated wood by comparing them with those of fire-retardant untreated wood from the expreimental resutls of cone calorimeter and thermo-gravimetric(TG) analyzer. Hazardousness of combustion product gases for fire-retardant treated wood and untreasted wood were also observed from the results of internal finish material incombustibility test according to the Korea standard code of KS F 2271. In this study, we also tried to improve the fire retardant performance of wood by applying fire-retardant chemical composites, and to secure the fire safety performance in buildings. Red pine (Pinus densiflora) was selected as a test specimen because it is mostly used as a building material in Korea. Fire retardant chemical composites (FRCs) were prepared by mixing boron, phosphorous, and nitrogen species and treated by press-impregnation method. Water-based FRCs were composed of 3% boric acid($H_3BO_3$), 3% borax decahydrate($Na_2B_4O_7$), 8% ammonium carbonate($(NH_4)_2CO_3$), diammonium phosphate ($(NH_4)_2HPO_4$) varied from 10-30% and potassium carbonate($K_2CO_3$) varied from 10-30%. From the test results of cone calorimeter, TG analysis and gas hazard assessments, newly proposed were the optimal composition and production methods of FRCs which can sufficiently meet fire-retardant level 3 based on Korea law of construction. Thus, the FRCs, developed in this study, are anticipated to contribute to the improvement of fire safety and widespread of usage in wood as building materials.

합판류 목재의 두께별 입사열유속에 따른 연소특성 비교 연구 (Analysis of Fire Characteristics based on the Thickness and Incident Heat Flux of Wood)

  • 황선우;박원희;김창용
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.13-21
    • /
    • 2020
  • 본 연구에서는 건축내장용 합판류 목재를 대상으로 목재의 두께별 다양한 입사열유속에 따른 연소특성 측정 실험을 수행하였으며, 측정한 연소특성은 EHC, HRR peak 및 도달시간, MARHE, 인화온도이다. 실험에 사용된 목재 시편은 4.8~18 mm 두께, 목재 시편에 유입되는 입사열유속은 25, 35, 50 및 60 kW/㎡을 적용하였으며, 목재 시편의 종류는 MDF 2종, 파티클 보드, 일반 합판이다. 종합적인 비교를 통하여 연소특성별 각각의 목재에 해당하는 화재패턴을 분석하여 화재에 대한 위험성을 검토하였다. 파티클 보드의 경우 화재 위험성이 높게 나타났으며, 제시한 연소특성 정량화 결과는 복합 가연물의 화재하중 산정에 중요한 입력 요소로 기여될 수 있다.

Ignition and Heat Release Rate of Wood-based Materials in Cone Calorimeter Tests

  • Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권2호
    • /
    • pp.1-8
    • /
    • 2008
  • This study was performed to evaluate the burning characteristics of wood-based materials and the effect of surface treatment of fire retardant using cone calorimeter. Four types of wood-based materials, such as Plywood, Oriented Strand Board (OSB), Particle Board (PB) and Medium Density Fiberboard (MDF), were tested at a constant heat flux of $50kW/m^2$ to investigate the time to ignition, mass loss rate, heat release rate, effective heat of combustion, etc. In addition, each type of wood-based material was tested at the same heat flux after fire retardant treatment on the surface to evaluate the effect of this treatment on the burning characteristics. The surface treatment of fire retardant, by the amount of $110g/m^2$, delayed the time to ignition almost twice. However, it was indicated that heat release rate, mass loss rate, and effective heat of combustion were not significantly affected by fire retardants treatment for all types of wood-based materials.

목재 가연물의 두께에 따른 화염연소와 훈소상태에서의 화재특성 (Fire Characteristics of Flaming and Smoldering Combustion of Wood Combustibles Considering Thickness)

  • 김성찬;남동군
    • 한국화재소방학회논문지
    • /
    • 제29권4호
    • /
    • pp.67-72
    • /
    • 2015
  • 본 연구는 콘칼로리미터 실험을 통해 건축물 마감재와 가구소재로 널리 적용되는 목재 가공품의 화염연소와 훈소시 화재특성을 파악하고자 한다. 시험대상 목재 가연물은 MDF, 합판, 칩보드이며 $50kW/m^2$의 복사열유속을 시편에 가하여 점화를 유도하였다. 실험과정에서 화재특성을 나타내는 발열량, 연소가스 생성율, 유효연소율 등의 주요 인자를 가연물의 두께에 따라 정량화하였다. 실험결과 초기 평면방향의 화염전파와 후기 시편의 관통에 의한 화재확대로 인해 단위면적당 발열량에 대한 두 개의 피크점이 관측되었다. 화염연소시의 질량감소율이 훈소시에 비해 5배 이상 높게 나타난 반면에 훈소과정에서 CO 생성율은 화염연소에 비해 10배 이상 높게 측정되어 훈소시 높은 독성가스 생성율을 보였다. 본 연구는 목재 가연물의 화재성상을 이해하고 화재해석을 위한 물성자료로 활용될 수 있다.

목질.시멘트보드의 물리.기계적 성질, 열전도성 및 내화성 (Physical and Mechanical Properties, Thermal Conductivity and Fire-Proof Performance of Wood-Cement Board)

  • 서진석;박종영
    • 한국가구학회지
    • /
    • 제14권2호
    • /
    • pp.31-38
    • /
    • 2003
  • This study was carried out to investigate characteristics of wood-based panels and wood-cement board for the possible uses as flooring and wall materials. The optimum cement/wood ratio(C/W ratio) of wood~cement board manufactured by clamp-pressing was from 2.7 to 3.2. The dimesional stability was superior in the C/W ratio of 3.2. Particularly, the dimensional stability of cement board using fine particle for particleboard face layer was favorable through three levels of C/W ratio. According to types of wooden material, bending strength of cement board using coarse particle for particleboard core layer or old newspaper(ONP) fiber was relatively higher than others. Thermal conductivities of wood-cement boards were no lower than that of gypsum board, and higher than those of plywood and boards. In case of wood-cement board of the C/W ratio of 2.7, the fire-proof performances of cement composite boards were greater than that of gypsum board, and weight loss reached to about a half of gypsum board. Then, wood-cement boards showed superior fire-proof performance compared to wood-based panels.

  • PDF