• Title/Summary/Keyword: without fire protection

Search Result 104, Processing Time 0.023 seconds

조사연구-각국 방화문의 내화시험 방법 비교

  • Park, Seung-In
    • Fire Protection Technology
    • /
    • s.18
    • /
    • pp.28-35
    • /
    • 1995
  • To survive in the 21C every nations in the World squeeze their intelligence. To our country, having a marvelous growth career in viewpoint of the economy, making efforts to renovate. Behind the breath of the economy a lot of law, regulations, standards of industry, and specifications are exists and the in-dustry controlled by these. Regretably in spite of surprising growth of our economy in a short period still keeps them old rules as they have been applies on our industry without change. In the part of the rife resistance standards, espacially for the fire door, needs grad-up much for the recently version compared with the other countries's. The rapid reshape of the world urges us be revolutionized in the part of the software, ie. these unchanged rules.

  • PDF

Simulation of Fire in Large Cleanrooms (대규모 클린룸 화재의 시뮬레이션)

  • Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.29-33
    • /
    • 2014
  • Cleanroom fires were simulated by using Fire Dynamics Simulator. A grid size of $0.5{\times}0.5{\times}0.2m^3$ was selected following review of grid sizes. Fires in three large cleanrooms were investigated to confirm safety by applying the requirements on temperature, visibility, and carbon monoxide concentration in performance based design. The worst situation without sprinkler system and air flow of 0.1 m/s downward in the cleamrooms was considered. It was confirmed that all the three cleanrooms were safe in case without sprinklers since the temperature was below the safety requirement. Decrease in visibility and carbon monoxide concentration due to the fires were negligible.

An Experimental Study on the Evaluation of the Fire-Resistance Performance of a Spray-Applied Rectangular Steel Structure (뿜칠피복 각형 강관의 내화성능 평가를 위한 실험적 연구)

  • Ok, Chi-Yeol;Kim, Jae-Jun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • Structures of steel frame buildings getting vary depending on the development of construction technology. Fire-resistant steel beams and Columns accredited by accreditation bodies from the performance of various fire-resistant coating is applied to the current pillar method is most H-beams. H-beam has been proposed a non-load test specifications in the relevant regulations, its scope of accreditation to be granted without limitation of size H-beams from the performance of the test specification. However, in the case of the rectangular steel structure is to check its performance and to a separate one of the receive acknowledge and so take advantage of the cross-sectional shape factor in this study to test the performance of the fire-resistant structure proposed for standard test specimen.

Arson Fire Analysis Involving the Use of Flammable Liquilds as Accelerants (인화성액체를 촉진제로 사용한 방화화재의 감식기법에 관한 연구)

  • Choi, Min-Ki;Han, Dong-Hun;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.64-72
    • /
    • 2014
  • Flammable liquids residues in fire debris and pyrolysis products of flammable materials were analyzed by using Gas detecting tube, Gas Chromatograph/Mass Spectrometers (GC/MS), and Pyrolyzer. Comparison studies between chemical components detected in debris fired with and without Flammable liquids were performed. Though Flammable liquids were not present in debris, Gas detecting tube colors were also changed. Chemical components produced from conventional combustions were different from those produced from pyrolysis. Due to the difference of the reaction conditions between combustions and pyrolysis, different chemical products were produced. Petrochemical products of PVC wood-linoleum block could produce ignitable chemicals, such as toluene, ethylbenzene, undecane, and dodecane. So, for better fire investigation more consideration of those chemicals will be porformed.

A study on the fire performance and heat transfer of the HPC column with fiber-cocktail in ISO fire under loading condition

  • Kim, Hyung-Jun;Kim, Heung-Youl;Kwon, In Kyu;Kwon, Ki-Hyuk;Min, Byung-Yeol;Cho, Bum-Yean
    • Computers and Concrete
    • /
    • v.12 no.5
    • /
    • pp.717-737
    • /
    • 2013
  • In this study, experiment and numerical analysis were conducted to identify the heat transfer characteristics and behavior of high-strength concrete upon a fire. The numerical analysis was employed to forecast the characteristics and properties of the high-strength concrete upon a fire, which can not be accomplished through a fire test due to the specific conditions and restrictions associated with the test. The result of the numerical analysis was compared with that of the test to verify the reliability of the analysis. In the numerical analysis of the heat transfer characteristics and behavior of 80 and 100 MPa high-strength concrete upon a fire, the commercial software of ABAQUS(V.6.8) was used. It was observed from the experiment that the contraction of the concrete with fiber-cocktail was mitigated by 25~55 % compared with that without fiber-cocktail because the fiber controlled the heat transfer of the concrete and thus improved the fire-resistance performance of the column.

Effects of the structural strength of fire protection insulation systems in offshore installations

  • Park, Dae Kyeom;Kim, Jeong Hwan;Park, Jun Seok;Ha, Yeon Chul;Seo, Jung Kwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.493-510
    • /
    • 2021
  • Mineral wool is an insulation material commonly used in passive fire protection (PFP) systems on offshore installations. Insulation materials have only been considered functional materials for thermal analysis in the conventional offshore PFP system design method. Hence, the structural performance of insulation has yet to be considered in the design of PFP systems. However, the structural elements of offshore PFP systems are often designed with excessive dimensions to satisfy structural requirements under external loads such as wind, fire and explosive pressure. To verify the structural contribution of insulation material, it was considered a structural material in this study. A series of material tensile tests was undertaken with two types of mineral wool at room temperature and at elevated temperatures for fire conditions. The mechanical properties were then verified with modified methods, and a database was constructed for application in a series of nonlinear structural and thermal finite-element analyses of an offshore bulkhead-type PFP system. Numerical analyses were performed with a conventional model without insulation and with a new suggested model with insulation. These analyses showed the structural contribution of the insulation in the structural behaviour of the PFP panel. The results suggest the need to consider the structural strength of the insulation material in PFP systems during the structural design step for offshore installations.

Experimental Study on the Fire Resistance of SC Composite Coloumn (SC 합성기둥의 내화성능에 대한 실험연구)

  • Lee, Sueng Jea;Kang, Seong Deok;Oh, Myoung Ho;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.4
    • /
    • pp.425-434
    • /
    • 2007
  • The SC (steel-concrete) composite column was developed to take advantage of the relative economy of using concrete as opposed to steel in carrying large compressive forces. As the SC composite column is pre-fabricated, its use can minimize laborand can speed up the erection of a steel building. In this study, an experiment was conducted to analyze the influence of several parameters, such as the load ratio, the concrete ratio of an area, and its performance with or without fire protection, on the performance of the SC composite column. This paper proposes that the calculation of the strength reduction ratios of columns be done by increasing the temperature. Theoretical equations were used to evaluate the effectiveness of the fire resistance of the SC composite column, and the results of the test and analysis were compared. The fire resistance of the SC composite column was increased by decreasing its load ratio, but the concrete ratio of an area has minimal influence on the fire resistance of the SC composite column.

Enhancing the Fire Performance of Concrete-Filled Steel Columns through System-Level Analysis

  • Fike, R.S.;Kodur, V.K.R.
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.11-21
    • /
    • 2013
  • The use of concrete filling offers a practical alternative for achieving the required stability of steel Hollow Structural Section (HSS) columns under fire conditions. However, current methods for evaluating fire resistance of Concrete Filled Hollow Structural Steel (CFHSS) columns are highly conservative as they are based on an elemental approach without due consideration to structural interactions that occur in framed structural systems. To overcome this limitation, a system level fire resistance analysis was carried out by treating CFHSS columns as part of an overall structural frame. In this analysis, an eight story steel-framed building was modeled under a range of standard and performance-based fire scenarios (including multi-story progressive burn-out fires) to evaluate the contribution of various structural members/assemblies to overall fire resistance. One of the primary factors considered was the use of concrete filling in HSS columns as an alternative to standard W-shape columns. Results from the analysis indicate that the use of CFHSS columns, in place of W-shape columns, in a performance-based environment can fully eliminate the need for applied fire protection to columns, while providing the required level of structural fire resistance.

A Study on the Problem and Improvement of the Fire Detector Test in the Field (화재감지기 현장점검의 문제점 및 개선방안에 관한 연구)

  • Ok, Kyung-Jea;Cha, Ha-Na;Kim, Shi-Kuk;Lee, Chun-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.180-184
    • /
    • 2008
  • Fire prevention strategies should be aimed at the prevention of structured fire since average annual rates of structured fire have been increased due to economic growth resulted in increasing high rise buildings and multipurpose occupancies over the past ten years. Hence, this study mainly focused on the improve method and problems in the field test of fire detector in compliances with experimental consideration. And it leads us to the flowing conclusions : Firstly, it is necessary to formulate a safety standards on field test. Nowadays, the test enforced in many ways without formulated standard. Therefore it is necessary to be complete the arrangements standardized and how to do the test with formulated safety standards. Second, it is necessary to establish the regal guidance with regard to inspection equipment, ie density, component and temperature of test equipment should be considered. Also the equipment is need to be standardized and improved. Third, fire inspector's competency in their practice should be enhanced. The problems arising from the lack of knowledge and competence regarding inspection could be settled by providing professional education to ensure proficiency in their practice. Specialized training, as has been noted, should be offered in accordance with occupancy type, scale and fire protection system in the fire facilities.

  • PDF

Numerical analysis of simply supported two-way reinforced concrete slabs under fire

  • Wenjun Wang;Binhui Jiang;Fa-xing Ding;Zhiwu Yu
    • Computers and Concrete
    • /
    • v.31 no.6
    • /
    • pp.469-484
    • /
    • 2023
  • The response mechanism of simply supported two-way reinforced concrete (RC) slabs under fire was numerically studied from the view of stress redistribution using the finite element software ABAQUS. Results show that: (1) Simply supported two-way RC slabs undergo intense stress redistribution, and their responses show four stages, namely elastic, elastic-plastic, plastic and tensile membrane stages. There is no cracking in the fire area of the slabs until the tensile membrane stage. (2) The inverted arch effect and tensile membrane effect improve the fire resistance of the two-way slabs. When the deflection is L/20, the slab is in an inverted arch effect state, and the slab still has a good deflection reserve. The deformation rate of the slab in the tensile membrane stage is smaller than that in the elastic-plastic and plastic stages. (3) Fire resistance of square slabs is better than that of rectangular slabs. Besides, increasing the reinforcement ratio or slab thickness improves the fire resistance of the slabs. However, an increase of cover thickness has little effect on the fire resistance of two-way slabs. (4) Compared with one-way slabs, the time for two-way slabs to enter the plastic and tensile cracking stage is postponed, and the deformation rate in the plastic and tensile cracking stage is also slowed down. (5) The simply supported two-way RC slabs can satisfy with the requirements of a class I fire resistance rating of 90 min without additional fire protection.