배전반 설비의 온라인 모니터링 및 진단 (On-Line Condition Monitoring and Diagnostics of Distribution Equipment)

  • 윤주호;임완수;황종선;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.525-526
    • /
    • 2007
  • Continuous on-line temperature monitoring provides the means to evaluate current condition of equipment and detect abnormality. It allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

Development of a Novel Noncontact ECG Electrode by MEMS Fabrication Process

  • Mathias, Dakurah Naangmenkpeong;Park, Jaesoon;Kim, Eungbo;Joung, Yeun-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권3호
    • /
    • pp.150-154
    • /
    • 2016
  • Contact electrodes pose threats like inflammation, metal poisoning, and allergic reaction to the user during long term ECG procedure. Therefore, we present a novel noncontact electrocardiographic electrode designed through microelectromechanical systems (MEMS) process. The proposed ECG electrode consists of small inner and large outer circular copper plates separated by thin insulator. The inner plate enables capacitive transduction of bio-potential variations on a subject’s chest into a voltage that can be processed by a signal processing board, whereas the outer plate shields the inner plate from environmental electromagnetic noise. The electrode lead wires are also coaxially designed to prevent cables from coupling to ground or electronic devices. A prototype ECG electrode has an area of about 2.324 cm2, is very flexible and does not require power to operate. The prototype ECG electrode could measure ECG at about 500 um distance from the subject’s chest.

고온초전도선재 제초기술과 개발 동향 (Manufacturing technology and R&D status of high temperature superconducting wire)

  • 오상수;하동우;하홍수;박찬;송규정;고락길;권영길;류강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.67-73
    • /
    • 2002
  • The development of high performance HTS wire is a key factor for various electrical applications of coils and cables. The purpose of this paper is to review and consider the main manufacturing technologies of HTS wire and its current status. A lot of efforts have been focused on the optimization of PIT parameters for Bi-2223/Ag wire. According to this, long Bi-2223 wires having Ic of 130 A were recently produced and their mass production has been underway in US. The current status performance of Bi-2223 wire is supposed to be used in power transmission cable because of its lower self-field property. Y-123 second generation conductor is extensively being developed throughout the world and many fabrication processes are competed with each other. 30 m-long Y-123 wire with Ic of 0.8 MA/$\textrm{cm}^2$ was recently fabricated using IBAD and PLD techniques in Japan. This result offers promise of scalable processing of practical multi-layer coated conductor.

  • PDF

상용차용 액셀 케이싱의 너트부 용접공정 자동화 시스템 개발 (Development about Welding-process Automatic System on the department of Axle Casing Nut for Commercial Vehicle)

  • 김재열;유신;오성민;장종훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.810-814
    • /
    • 1996
  • The purpose of this exclusive welding-machine process using the welding Torch-rotation form is to develop a mechanism which can solve the problem of twisted welding wires and cables. The technique was developed by revising the torch position and smooth controlling of both the formal and reverse rotation. Some of the advantages of using the Torch-rotation form over the Work-rotation technique are the practical uses of increased work space and link work with the automation system of the plant. Using this welding machine process, It is possible to design a specific tool in order to solve the implemental problem. And I produced a control plate which can manipulate the progress of the entire process at the work place. Even if another kind of axle casing's welding work is used this process can be utilized if the fixed tip and work is produced and changed. The development if this exclusive welding-machine could reduce the manpower of skilled welding labor and after considerable analysis, this machine was found to increase productivity and better quality product in comparison to the handmade product.

  • PDF

Nonlinear Dynamic Analysis of a Large Deformable Beam Using Absolute Nodal Coordinates

  • Jong-Hwi;Il-Ho;Tae-Won
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권4호
    • /
    • pp.50-60
    • /
    • 2004
  • A very flexible beam can be used to model various types of continuous mechanical parts such as cables and wires. In this paper, the dynamic properties of a very flexible beam, included in a multibody system, are analyzed using absolute nodal coordinates formulation, which is based on finite element procedures, and the general continuum mechanics theory to represent the elastic forces. In order to consider the dynamic interaction between a continuous large deformable beam and a rigid multibody system, a combined system equations of motion is derived by adopting absolute nodal coordinates and rigid body coordinates. Using the derived system equation, a computation method for the dynamic stress during flexible multibody simulation is presented based on Euler-Bernoulli beam theory, and its reliability is verified by a commercial program NASTRAN. This method is significant in that the structural and multibody dynamics models can be unified into one numerical system. In addition, to analyze a multibody system including a very flexible beam, formulations for the sliding joint between a very deformable beam and a rigid body are derived using a non-generalized coordinate, which has no inertia or forces associated with it. In particular, a very flexible catenary cable on which a multibody system moves along its length is presented as a numerical example.

온도센서를 이용한 전력설비의 온라인 상태 감시 (On-Line Condition Monitoring of Electrical Equipment Using Temperature Sensor)

  • 최용성;김선재;김영민;송환기;이경섭
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.202-208
    • /
    • 2008
  • Condition monitoring technologies allow achieving this goal by minimizing downtime through the integrated planning and scheduling of repairs indicated by condition monitoring techniques. Thermal runaways induced by conduction problems deteriorate insulating material and cause disruptive dielectric discharges resulting in arcing faults. Therefore, having the ability to directly measure the temperature of the contacts while in service will provide more information to determine the true condition of the equipment. It allows connective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on -line condition monitoring of energized equipment is applicable both as stand alone system and with an interface for power quality monitoring system. The paper presents the results of wireless temperature monitoring: of electrical equipment at a power plant.

Design and performance validation of a wireless sensing unit for structural monitoring applications

  • Lynch, Jerome Peter;Law, Kincho H.;Kiremidjian, Anne S.;Carryer, Ed;Farrar, Charles R.;Sohn, Hoon;Allen, David W.;Nadler, Brett;Wait, Jeannette R.
    • Structural Engineering and Mechanics
    • /
    • 제17권3_4호
    • /
    • pp.393-408
    • /
    • 2004
  • There exists a clear need to monitor the performance of civil structures over their operational lives. Current commercial monitoring systems suffer from various technological and economic limitations that prevent their widespread adoption. The wires used to route measurements from system sensors to the centralized data server represent one of the greatest limitations since they are physically vulnerable and expensive from an installation and maintenance standpoint. In lieu of cables, the introduction of low-cost wireless communications is proposed. The result is the design of a prototype wireless sensing unit that can serve as the fundamental building block of wireless modular monitoring systems (WiMMS). An additional feature of the wireless sensing unit is the incorporation of computational power in the form of state-of-art microcontrollers. The prototype unit is validated with a series of laboratory and field tests. The Alamosa Canyon Bridge is employed to serve as a full-scale benchmark structure to validate the performance of the wireless sensing unit in the field. A traditional cable-based monitoring system is installed in parallel with the wireless sensing units for performance comparison.

Development of Prototype Multi-channel Digital EIT System with Radially Symmetric Architecture

  • Oh, Tong-In;Baek, Sang-Min;Lee, Jae-Sang;Woo, Eung-Je;Park, Chun-Jae
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권4호
    • /
    • pp.215-221
    • /
    • 2005
  • We describe the development of a prototype multi-channel electrical impedance tomography (EIT) system. The EIT system can be equipped with either a single-ended current source or a balanced current source. Each current source can inject current between any chosen pair of electrodes. In order to reduce the data acquisition time, we implemented multiple digital voltmeters simultaneously acquiring and demodulating voltage signals. Each voltmeter measures a differential voltage between a fixed pair of adjacent electrodes. All voltmeters are configured in a radially symmetric architecture to optimize the routing of wires and minimize cross-talks. To maximize the signal-to-noise ratio, we implemented techniques such as digital waveform generation, Howland current pump circuit with a generalized impedance converter, digital phase-sensitive demodulation, tri-axial cables with both grounded and driven shields, and others. The performance of the EIT system was evaluated in terms of common-mode rejection ratio, signal-to-noise ratio, and reciprocity error. Future design of a more innovative EIT system including battery operation, miniaturization, and wireless techniques is suggested.

2세대 도체 344B를 사용한 초전도 모델 케이블에서의 과전류 특성분석 (Over current characteristic analysis of superconducting model cable using 2G wire 344B)

  • 김대원;김아롱;김진근;박민원;유인근;조전욱;심기덕;김석호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.603_604
    • /
    • 2009
  • HTS tape is developed for the purpose of being applied to the power cable, motor and generator, etc. The resistance of conventional power cables is not changed a lot by over current condition. But HTS(High temperature superconductor)power cable has some different properties. The impedance of superconductor is changed due to the magnitude of current, temperature, and magnetic field. And the characteristics analysis of HTS power cable under many kind of fault conditions are important to apply real system. In addition the magnitude of over current is 10 times larger than rated current. In this paper, the characteristics of HTS power cable are analyzed when over current flows. Model cable used 2G wires was made and experimented. The results will be helpful to manufacture real HTS power cable.

  • PDF

웨이브렛 변환을 이용한 혼합송전계통에서의 디지털 거리계전 알고리즘에 관한 연구 (A Study on the Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line with Underground Power Gables)

  • 정채균;홍동석;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.383-386
    • /
    • 2001
  • Distance relay is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and cable cover protection units (CCPUs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable system, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using db1 coefficient summation. And also, error compensation factor was proposed for correct calculation of impedance in power cable.

  • PDF