• Title/Summary/Keyword: wire-plate

Search Result 287, Processing Time 0.024 seconds

Bond Stress-Strain Predict Model with Inner Cover Thickness of Steel Wire Used in Void Deck Plate (중공 데크플레이트에 사용된 철선의 내부피복두께에 따른 부착응력-변형률 예측모델)

  • Kim, Hee-Hyeon;Choi, Chang-Sik
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.41-51
    • /
    • 2018
  • In case of evaluating the bond stress of a void deck plate using a wire steel, there is no standard formula considering both the influence on the void and the type of the reinforcing bar. Therefore we proposed a model equation considered the bond characteristics of the void deck plate. A total of 46 specimens was carried out a direct pull-out test and the test variables were the presence of a void body, type of reinforcing bar, the inner cover thickness according to the location of reinforcing bars and bond region. As a result of the comparison between the steel bar and steel wire, the bond stress of the steel wire with the relative rib area of 0.071 is 4.5 ~ 28.58% lower than that of the steel bar with 0.092 and the bond stress reduction rate increases when the inner cover thickness is insufficient. In the case of the inner cover thickness of $1.7d_b$ and $2.7d_b$, the bond stress was reduced to 48.7 ~ 68.4%. In the inner cover thickness was $4.9d_b$ and $5.2d_b$, the bond stresses were equivalent to those of the solid specimens. It was confirmed that the average bond stress and strain were affected by the inner cover thickness. Therefore the predicted model for one module of the void deck plate is proposed and verified by considering the bond characteristics of the void deck plate.

Reduction Characteristics of Electromagnetic Penetration through Narrow Slots in Conducting Screen

  • Park Eun-Jung;Kim Ki-Chai
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.2
    • /
    • pp.130-134
    • /
    • 2006
  • This paper presents the reduction characteristics of penetrated electromagnetic fields through a narrow slot in a planar conducting screen of infinite extent. When a plane wave is excited to the narrow slot, the aperture electric field is controlled by the parallel wire or parallel plate connected on the slot. The magnitude of penetrated electromagnetic fields through a narrow slot is controlled by electric field distributions on the slot. An integral equation for the aperture electric field on narrow slots is derived and solved by applying Galerkin's method of moments. The results show that the magnitude of the penetrated electromagnetic field can be effectively reduced by installing the parallel wire or parallel plate on the slot.

Simulation of Magnetic Field and Removal Characteristic of Nitrogen Oxide Using Wire-Plate Type Plasma Reactor (선 대 평판형 플라즈마 반응기를 이용한 자계 시뮬레이션과 질소산화물제거 특성)

  • 이현수;박재윤
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.407-411
    • /
    • 2003
  • The purpose of this paper is to study the removal of nitrogen oxide(NOx) using a wire-plate type plasma reactor with magnet attached for indoor air purification. In order to produce a more effective reactor, we conducted magnetic field simulations. The results of the magnetic field simulations show that NOx can be removed more effectively. The results from the magnetic field simulation show that when 7 magnets were applied to the reactor, the magnetic flux density was at its highest amount than when using 0, 3, or 5 magnets. From the data obtained by the simulation results a plasma reactor was made and thus, several experiments were conducted. The best removal efficiency was obtained with 14 W AC power to the reactor with 5 magnets.

A Study on the Removal of SOx/NOx by a Pulsed Corona Discharge in the Wire-Plate Reactor (Wire-Plate 반응기에서 펄스 코로나 방전을 이용한 탈황 탈질에 관한 연구)

  • Shin, Wan-Ho;Song, Yong-Hoon;Kim, Han-Seok;Choi, Yeon-Seok;Kim, Seok-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1910-1912
    • /
    • 1996
  • This paper presents the results of laboratory experimentals to remove $SO_2$ and $NO_x$ by a pulsed corona discharge in the wire-plate reactor. A rotating spark gap switch was used to generate the pulse by chewing the dc high voltage. Repetition frequency of the pulse was 60Hz and rising time of 50ns. The photo pictures of positive streamer corona taken by ICCD camera, pulse voltage and current were measured using a digital oscilloscope. Simultaneous effects of $C_{2}H_{4}$ injection and heterogeneous chemical reactions on nonthermal plasma process to remove $SO_2$ and $NO_x$ from flue gas were investigated in the present study

  • PDF

Effect of Magnetic Field on NOx Removal for Wire-Plate Plasma Reactor (선대 평판형 플라즈마 반응기에서 NOx 제거에 미치는 자계의 영향)

  • Park, J.Y.;Son, S.D.;Han, S.B.;Lee, D.H.;Kim, J.D.;Mun, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2251-2252
    • /
    • 1999
  • In this paper, the effect of magnetic field was measured on NOx removal characteristics for wire-plate plasma reactor with magnetic field applied to electric field vertically. NOx from simulated diesel engine flue gas are decomposed by the corona discharge of DC, AC and Pulsed voltages in wire-plate reactor. Consumption power increased with increasing discharge voltage. When magnetic field was applied to electric field vertically, consumption power decreased. NOx removal rate and arc transition voltage of plasma reactor with magnetic field were higher than those of plasma reactor without magnetic field.

  • PDF

Experimental Study on the Discharge Electrode of A Two-Stage Electrostatic Air Cleaner (2단 평행판 전기집진기의 방전부 특성 실험)

  • Kim, I.S.;Lee, J.O.;Kim, Y.J.;Choi, H.O.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.1
    • /
    • pp.27-34
    • /
    • 1993
  • The two-stage electrostatic air cleaner is a particle control device that uses electrical forces to move particles in the flowing gas stream onto collector plates. Despite a general understanding of electrostatic air cleaner operation and their successful use in industry, many questions regarding flow, electric fields and particle collection have remained unanswered. In this paper, an experimental investigation for designing the discharge electrode, including ionizer wire diameter, plate length and wire-to-plate spacing, is carried out. The electrical conditions, namely the electric field intensity, the space current and the particle charge intensity, in wire-plate electrostatic air cleaner are reported and examined.

  • PDF

Treatment of Acute Acromioclavicular Joint Dislocation: Kirschner's Wire Trans-acromial Fixation versus AO Locking Hook Plate Fixation

  • Kim, Young-Jun;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.149-154
    • /
    • 2016
  • Background: The purpose of this study is to compare clinical and radiological outcomes between trans-acromial fixation with Kirschner's wire (K-wire) and AO locking hook plate fixation for acute acromioclavicular (AC) joint dislocation. Methods: This study included 61 patients who underwent either closed reduction and trans-acromial fixation with K-wire (group A, 23 patients) or open reduction and internal fixation with AO locking hook plate (group B, 38 patients). Pain on a visual analogue scale (VAS) score, the University of California Los Angeles (UCLA) shoulder score, the American Shoulder and Elbow Surgeons (ASES) score, and active range of motion (ROM) were used in the functional evaluation. For radiological evaluation, coracoclavicular distance (CCD) was measured on both clavicular anteroposterior view and compared between groups. Results: At one-year follow-up, no significant differences in VAS pain score, UCLA shoulder score, ASES score, and active ROM were observed between groups, despite five cases (22.7%, 5/23) of complication in group A. The side-to-side difference between normal and affected CCD was $2.4{\pm}2.2mm$ in group A and $0.2{\pm}0.7mm$ in group B. This difference showed a statistical significance between groups (p<0.001). Conclusions: For the treatment of acute AC joint dislocation, the K-wire trans-acromial fixation group showed a significantly greater CCD than the AO locking hook plate group. In addition, during the follow-up period, much higher incidence of complication related to implant was observed in the trans-acromial fixation group. Although clinical outcomes between groups were not significantly different, these results should be interpreted carefully.

Development of 22,000Ton Hydraulic Press for the Forming of Heat Plate with Ultra-Large Size (초대형 열교환기용 열판 성형을 위한 22,000Ton급 유압 프레스 개발)

  • Lim S. J.;Park H. J.;Yoon D. J.;Kim E. Z.;Lim H.;Na K. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.166-169
    • /
    • 2001
  • 22,000 Ton hydraulic press was developed using wire winding method. The hydraulic press consists of three piece of frame type. The outer layers of yoke-column frame and main cylinder linear were wound with piano wire(1mm${\times}$4mm) under controlled tension and the total length of wound wire was about 450Km. The developed hydraulic press is used for the forming of heat plate with ultra-large size. To obtain large force with relative small apparatus, high pressure of $1,500 Kgf/cm^2$ was supplied to main cylinder through pressure amplification by booster pump. Therefore sealing technique of main cylinder is so crucial that the seals were made of mitre ring type with super-elastic metal. The press total weight is about 150 tons, which is quite light and compact relative to that of conventional hydraulic press.

  • PDF

Flexural Capacity and CO2 Reduction Evaluation for Composite Beam with Weight Reducing Steel Wire-Integrated Void Deck Plate slab (자중저감 철선일체형 중공 데크플레이트 슬래브를 사용한 합성보의 휨내력 및 CO2 감소량 평가)

  • Kim, Sang-Seop;Park, Dong-Soo;Boo, Yoon-Seob
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.313-323
    • /
    • 2012
  • The purpose of this study is to evaluate $CO_2$ reduction and the flexural performance of steel wire-integrated void deck plate slabs that were inserted in omega-shaped steel plates to reduce concrete and welded H-section beams. The void deck plate slab can secure the structure, not only reducing the weight of the building but it is also eco-friendly. Therefore, this study evaluated the flexural performance of the composite beam by conducting a monotonic loading test with the use of actuators. It quantitatively evaluated the $CO_2$ emission based on earlier studies. The main test parameters are the concrete thickness of upper slabs, and the interrupted width of the omega-shaped steel plate. The result of the test showed that the welded H-section beam applied steel wire-integrated void deck plate slabs that were inserted into the omega-shaped steel plate declined in flexural performance on the composite beam after reducing concrete volume. Likewise, it is effective in reducing $CO_2$.

Recycling of Wastepaper(IX)-Effects of KOCC Fines and Other Contamination on Condebelt Press Drying System- (고지재생연구(제 9보)-국산 골판지 고지 내의 미세분 및 이물질들이 Condebelt Press Drying System에 미치는 영향-)

  • 지경락;류정용;신종호;송봉근
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.1
    • /
    • pp.19-25
    • /
    • 2000
  • In Condebelt press drying system, the temperature difference between top and bottom plate of Condebelt transfers water to bottom side, Fine fibers, stickies , ink , and various inorganic materials are also migrated to the fine wire located at the bottom plate by highly pressurized moisture flow. As a result, the fine wire contaminated by plugging of these fine and sticky materials can cause many problems such as blistering or partial crushing of paper. The contaimination of fine wire leads to a deterioroated strength together with uneven physical properties of paper. In this paper, froth-flotatiion method, which is commonly used in the field of ONP recycling process, were adopted to separate the contaminants in KOCC as a new fiber fractionation method. Standard deviation of paper strength and brighteness decreased of Condebelt fine wire were measured to investigate the effect of contaminants removal . The standard deviations of paper strength obtained from the flotated accept were not dependent on the number of condebelt press drying . However, in the case of untreated KOCC, the standard deviations were increased as press drying repeated. This indicates that the contaminant gives uneven physical properties to the paper by wire plugging . Optical and SEM images clearly illustrate the effect of contaminants on the wire condition.

  • PDF