• 제목/요약/키워드: wire model

검색결과 655건 처리시간 0.031초

수평으로 매설된 도선의 접지임피던스의 주파수의존성을 계산하는 기법 (A Method of Computing the Frequency-Dependent Ground Impedance of Horizontally-buried Wires)

  • 조성철;이복희
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.745-752
    • /
    • 2016
  • The parameters of Debye's equation were applied to analyze the frequency-dependent ground impedance of horizontally-buried wires. We present a new method, based on Debye's equation, of analyzing the effect of polarization on frequency-dependent ground impedance. The frequency-dependent ground impedances of a horizontally-buried wire are directly measured and calculated by applying sinusoidal current in the frequency range of 100 Hz to 10 MHz. Also, the results obtained in this work were compared with the data calculated from empirical equations and commercial programs. A new methodology using the delta-gap source model is proposed in order to calculate frequency-dependent ground impedance when the ground current is injected at the middle-point of the horizontal ground electrode. The high frequency ground impedance of horizontal electrodes longer than 30 m is larger or equal to its low frequency ground resistance. Consequently, the frequency-dependent ground impedance simulated with the proposed method is in agreement with the experimental data, and the validity of the computational simulation approach is confirmed.

전송로의 직렬리앤턴스 산정 시 Carson 모델의 적용범위 검토 (Study of the Applicability of the Carson Line Model for the Series Reactance Calculation of the Power Feeding Lines with no Ground Return)

  • 정상기;권삼영;창상훈;장동욱
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.225-231
    • /
    • 2009
  • In this paper, it is shown that Carson's equation can still be applied for the calculation of the series reactance of transmission lines with no ground return current as well as the one with ground return. It is proved in the following method. First two voltage drop equations for three-phase three wire transmission line are derived, one without considering ground return and the other using Carson's equation. The impedance matrix of the two equations are different from each other. But if we put the condition of zero ground current, $I_a+I_b+I_c=0$, those two equations becomes the identical equations. Therefore even a transmission line is not grounded, its line parameters can still be obtained using the Carson's equation. It has been confused whether or not Carson's equation can be used for an ungrounded system. It is because where ever Carson's equation is shown in the book, it also says that the system has ground return current paths as a premise. It is also verified with EMTP studies on the test circuit.

Aerodynamic stability of stay cables incorporated with lamps: a case study

  • Li, S.Y.;Chen, Z.Q.;Dong, G.C.;Luo, J.H.
    • Wind and Structures
    • /
    • 제18권1호
    • /
    • pp.83-101
    • /
    • 2014
  • Lamps installed on stay cables of cable-stayed bridges may alter the configuration of circular cross section of the cables and therefore result in aerodynamically unstable cable vibrations. The background of this study is a preliminary design of lamp installation on the cable-stayed He-dong Bridge in Guangzhou, China. Force measurements and dynamic response measurements wind tunnel tests were carried out to validate the possibility of cable galloping vibrations. It is observed that galloping will occur and the critical wind velocity is far less than the design wind velocity at Guangzhou City stipulated in Chinese Code. Numerical simulations utilizing software ANSYS CFX were subsequently performed and almost the same results as the wind tunnel tests were obtained. Moreover, the pressure and velocity contours around cable-lamp model obtained from numerical simulations indicated that the upstream steel wire in the preliminary design is the key factor for the onset of the galloping vibrations. A modification for the preliminary design of lamp installation, which suggests to remove the two parallel steel wires, is proposed, and it effectiveness is validated in further wind tunnel tests.

제어법칙 개발을 위한 소프트웨어 전환장치 설계에 관한 연구 (A Study on the Design of Software Switching Mechanism for Develops the Flight Control Law)

  • 김종섭;조인제;안종민;신지환;박상선
    • 제어로봇시스템학회논문지
    • /
    • 제12권11호
    • /
    • pp.1130-1137
    • /
    • 2006
  • Relaxed Static Stability(RSS) concept has been applied to improve aerodynamic performance of modern version supersonic jet fighter aircraft. Therefore, the flight control systems are necessary to stabilizes the unstable aircraft and provides adequate handling qualities. The initial production flight control system are verified by flight test and it's always an elements of danger because of flight-critical nature of control law function and design error due to model base design method. These critical issues impact to flight safety, and it could be lead to a loss of aircraft and pilot's life. Therefore, development of an easily modifiable RFCS(Research Flight Control System) capable of reverting to a PFCS(Primary Flight Control System) of reliable control law must be developed to guarantee the flight safety. This paper addresses the concept of SSWM(Software Switching Mechanism) using the fader logic such as TFS(Transient Free Switch) based on T-50 flight control law. The result of the analysis based on non-real time simulation in-house software using SSWM reveals that the flight control system are switching between two computers without any problem.

A Novel Fault Location Scheme on Korean Electric Railway System Using the 9-Conductor Representation

  • Lee, Chang-Mu;Lee, Han-Sang;Yoon, Dong-Hee;Lee, Han-Min;Song, Ji-Young;Jang, Gil-Soo;Han, Byung-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.220-227
    • /
    • 2010
  • This paper presents a novel fault location scheme on Korean AC electric railway systems. On AC railway system, because of long distance, 40[km] or above, between two railway substations, a fault location technique is very important. Since the fault current flows through the catenary system, it must be modeled exactly to analyze the fault current magnitude and fault location. In this paper, suggesting the novel scheme of fault location, a 9-conductor modeling technique including boost wires and impedance bonds is introduced based on the characteristics of Korean AC electric railway. After obtaining a 9-conductor modeling, the railway system is constructed for computer simulation by using PSCAD/EMTDC. By case studies, we can verify superiority of a new fault location scheme and propose a powerful model for fault analysis on electric railway systems.

등치선 삼각분할을 위한 띠 분할 알고리즘 (A Band Partitioning Algorithm for Contour Triangulation)

  • 최영규;조태훈
    • 한국정보처리학회논문지
    • /
    • 제7권3호
    • /
    • pp.943-952
    • /
    • 2000
  • The surface reconstruction problem from a set of wire-frame contours is very important in diverse fields such as medical imaging or computer animation. In this paper, surface triangulation method is proposed for solving the problem. Generally, many optimal triangulation techniques suffer from the large computation time but heuristic approaches may produce very unnatural surface when contours are widely different in shape. To compensate the disadvantages of these approaches, we propose a new heuristic triangulation method which iteratively decomposes the surface generation problem from a band (a pair of vertices chain) into tow subproblems from two sub-bands. Generally, conventional greedy heuristic contour triangulation algorithm, suffer from the drastic error propagation during surface modeling when the adjacent contours are different in shape. Our divide-and-conquer algorithm, called band partitioning algorithm, processes eccentric parts of the contours first with more global information. Consequently, the resulting facet model becomes more stable and natural even though the shapes are widely different. An interesting property of our method is hat it supports multi-resolution capability in surface modeling time. According to experiments, it is proved to be very robust and efficient in many applications.

  • PDF

인체 모델 생성을 위한 등고선 삼각분할 기반의 3차원 전신 스캐너 개발 (Development of a 3D Whole Body Scanner for Reconstructing Human Body based on Contour Triangulation Technique)

  • 최영규;구본기;최병태
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제30권7_8호
    • /
    • pp.397-407
    • /
    • 2003
  • 인간의 신체에 대한 정확한 3차원 표면모델을 추출할 수 있는 기술에 대한 요구와 관심이 최근 멀티미디어 등 다양한 응용 분야에서 증폭되고 있다. 본 논문에서는 인체의 ,3차원 모델을 효율적으로 추출하기 위한, 3차원 스캐너를 소개하였으며, 취득된 3차원 정보로부터 등고선(Wire-frame Contour)을 안정적으로 생성하는 반자동 등고선 생성 방법을 제안하였다. 또한 생성된 등고선으로부터 3차원 표면모델을 추출하기 위한 표면 삼각분할 알고리즘을 제안하였다. 실험을 통해 개발된 시스템과 제안된 방법이 안정적이고 효과적으로 인체의, 3차원 표면모델을 생성하는 것을 확인할 수 있었다.

Force monitoring of steel cables using vision-based sensing technology: methodology and experimental verification

  • Ye, X.W.;Dong, C.Z.;Liu, T.
    • Smart Structures and Systems
    • /
    • 제18권3호
    • /
    • pp.585-599
    • /
    • 2016
  • Steel cables serve as the key structural components in long-span bridges, and the force state of the steel cable is deemed to be one of the most important determinant factors representing the safety condition of bridge structures. The disadvantages of traditional cable force measurement methods have been envisaged and development of an effective alternative is still desired. In the last decade, the vision-based sensing technology has been rapidly developed and broadly applied in the field of structural health monitoring (SHM). With the aid of vision-based multi-point structural displacement measurement method, monitoring of the tensile force of the steel cable can be realized. In this paper, a novel cable force monitoring system integrated with a multi-point pattern matching algorithm is developed. The feasibility and accuracy of the developed vision-based force monitoring system has been validated by conducting the uniaxial tensile tests of steel bars, steel wire ropes, and parallel strand cables on a universal testing machine (UTM) as well as a series of moving loading experiments on a scale arch bridge model. The comparative study of the experimental outcomes indicates that the results obtained by the vision-based system are consistent with those measured by the traditional method for cable force measurement.

Reinforcement design for the anchorage of externally prestressed bridges with "tensile stress region"

  • Liu, C.;Xu, D.;Jung, B.;Morgenthal, G.
    • Computers and Concrete
    • /
    • 제11권5호
    • /
    • pp.383-397
    • /
    • 2013
  • Two-dimensional tensile stresses are occurring at the back of the anchorage of the tendons of prestressed concrete bridges. A new method named "tensile stress region" for the design of the reinforcement is presented in this paper. The basic idea of this approach is the division of an anchor block into several slices, which are described by the tensile stress region. The orthogonal reinforcing wire mesh can be designed in each slice to resist the tensile stresses. Additionally the sum of the depth of every slice defined by the tensile stress region is used to control the required length of the longitudinal reinforcement bars. An example for the reinforcement design of an anchorage block of an external prestressed concrete bridge is analyzed by means of the new presented method and a finite element model is established to compare the results. Furthermore the influence of the transverse and vertical prestressing on the ordinary reinforcement design is taken into account. The results show that the amount of reinforcement bars at the anchorage block is influenced by the layout of the transverse and the vertical prestressing tendons. Using the "tensile stress region" method, the ordinary reinforcement bars can be designed more precisely compared to the design codes, and arranged according to the stress state in every slice.

AC 전기철도 급전선 선로정수 산정시 Carson 모델 적용 검토 (Applicability Study of the Carson Model for the calculation of the series inductance of the power feeding lines in AC traction system)

  • 정상기;권삼영;창상훈;장동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.169-178
    • /
    • 2008
  • In this paper, it is shown that Carson's equation can still be applied for the calculation of the series reactance of transmission lines with no ground return current as well as the one with ground return. It is proved in the following method. First two voltage drop equations for three-phase three wire transmission line are derived, one without considering ground return and the other using Carson's equation. The impedance matrix of the two equations are different from each other. But if we put the condition of zero ground current, $I_a+I_b+I_c=0$, those two equations becomes the identical equations. Therefore even a transmission line is not grounded, its line parameters can still be obtained using the Carson's equation. It has been confused whether or not Carson's equation can be used for an ungrounded system. It is because where ever Carson's equation is shown in the book, it also says that the system has ground return current paths as a premise. It is also verified with EMTP studies on the test circuit.

  • PDF