• Title/Summary/Keyword: wire electrode

Search Result 224, Processing Time 0.025 seconds

Design of Compression Pants for Wireless sEMG Monitoring using e-textile (E-textile을 이용한 무선 sEMG 모니터링 컴프레션 바지 설계)

  • Heejae Jin;Hyojeong Lee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.48 no.1
    • /
    • pp.94-107
    • /
    • 2024
  • This study developed compression pants with excellent wearability and signal quality by approaching the design of wireless sEMG monitoring pants from the perspective of technical design, including the evaluation of wearability and the stable wireless transmission of signals through electrode and circuit design, and using e-textiles. An electrode, sewn with silver thread and a circuit stitched in a zigzag pattern using stainless steel wire, were applied. Additionally, polyurethane sealing tape was used to enhance adherence to the skin and reduce electrical resistance. Conductive snaps completed the design, allowing attachment and detachment to the bio-signal acquisition mainboard. Through the subjects' evaluation, it was determined that the final pants were applied with a pattern reduction rate of 25% to provide superior comfort according to different body parts while also minimizing skin irritation around the thigh circuit. The final pants for wireless sEMG monitoring, which demonstrated stable transmission of wireless measurements, was positively evaluated in terms of cognitive acceptability. This study is significant in that it achieved an optimal design by considering both technical aspects and the electrical characteristics of bio-signal monitoring garments, as well as the wearer's perception when designing smart wear.

A Comparison of Surgical Methods of Inducing Femoral Head Osteonecrosis in Rats (랫드에서 대퇴골머리 골괴사 유발 외과적 방법의 비교)

  • Kim, Jun-Soo;Park, Jin-Uk;Choi, Seok-Hwa;Kim, Gon-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.27 no.3
    • /
    • pp.240-245
    • /
    • 2010
  • Osteonecrosis of the femoral head is an idiopathic and progressive disease. It was reported that several animal models have been used for the research of osteonecrosis. However, no standardized animal model for the study of osteonecrosis has been developed to date. This study was conducted to compare the degree of osteonecrosis of three surgically induced osteonecrosis models in rats. Twenty Sprague-Dawley rats (24 weeks old, male) were divided into three experimental groups and a control group, five heads each. Three groups were surgically induced into osteonecrosis; the ligamentum teres were cut and the periosteum of the femoral neck was stripped (Group S), the steel wire was ligated to the neck of the femoral head (Group W), and the femoral neck was tied up with a wire in the same way as in the W group, and burned by attaching the electrode tip to the wire and then the wire was removed (Group B). After two weeks, rats were sacrificed and the femoral head and neck were collected. Histological findings were evaluated with H/E stains, Safranin-O and TUNEL for osteonecrotic lesions in the bones and cartilages of the femoral head. Osteonecrosis was induced successfully in all groups (Group S, W and B) in two weeks, a short period of time. Significant necrotic changes of the cartilage were detected only in Group B. In the modified cautery model in particular, the method of removing the wire after cautery was completed in the experimental model of osteonecrosis more efficiently than any other method.

Manufacturing of Metal Micro-wire Interconnection on Submillimeter Diameter Catheter (서브-밀리미터 직경의 카테터 표면 위 금속 마이크로 와이어 접착 공정)

  • Jo, Woosung;Seo, Jeongmin;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.2
    • /
    • pp.29-35
    • /
    • 2017
  • In this paper, we investigated a manufacturing process of metal micro-wire interconnection on submillimeter diameter catheter. Over the years, flexible electronic researches have focused on flexible plane polymer substrate and micro electrode manufacturing on its surface. However, a curved polymer substrate, such as catheter, is very important for medical application. Among many catheters, importance of submillimeter diameter steerable catheter is increasing to resolve the several limitations of neurosurgery. Steering actuators have been researched for realizing the steerable catheter, but there is no research about practical wiring for driving these actuators. Therefore we developed a new manufacturing process for metal micro-wire interconnection on submillimeter diameter catheter. We designed custom jigs for alignment of the metal micro-wires on the submillimeter diameter catheter. An UV curing system and commercial products were used to reduce the manufacturing time and cost; Au micro-wire, UV curable epoxy, UV lamp, and submillimeter diameter catheter. The assembled catheter was characterized by using an optical microscope, a resistance meter, and a universal testing machine.

Silicone Rubber Membrane-Based Chloride Ion-Selective Electrode (실리콘러버-지지체 염화이온선택성 막전극)

  • Sakong, Dong-Sik;Kim, Jin-Mog;Cha, Jin-Mog
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.12
    • /
    • pp.653-660
    • /
    • 1997
  • Silicone rubber-matrix membranes doped with tetradecyltrimethylammonium chloride (TDTMACl) are used to enhance electrode performance for chloride measurements in physiological samples. The optimized membrane formulation incorporates 95.4 wt% silicone rubber and 4.6 wt% TDTMACl, and its pH response is negligible in the range of pH 6-10. The TDTMACl-doped silicone rubber membrane exhibits sub-Nernstian response to chloride from 10 to 300 mM (-37.5 mV/decade), but its selectivities for chloride over other anions are remarkably enhanced: KpotCl,NO3=1.3, KpotCl,I=2.0, KpotCl,Sal=0.8, KpotCl,SCN=2.0 and KpotCl,ClO4=0.8. Furthermore, since the silicone rubber-matrix membrane exhibits better adhesion to the solid surface than do PVC membranes, the lifetime of the coated-wire type membrane electrode is greatly improved. The response properties toward chloride and salicylate for solid-state sensor are not significantly changed after at least 35 days of use.

  • PDF

The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal (ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템)

  • Kim, Jeong-Do;Kim, Kap-Jin;Chung, Gi-Su;Lee, Jung-Hwan;Ahn, Jin-Ho;Lee, Sang-Goog
    • The KIPS Transactions:PartA
    • /
    • v.17A no.3
    • /
    • pp.145-152
    • /
    • 2010
  • Most wearable system for mobile healthcare applications consists of three parts. The first part is the sensing elements based on bio-signal, the second is the circuit module for control, data acquisition and wireless communication and control and the third is garment with a built-in electrodes and circuits. The existing healthcare garment systems have to find a solution to signal-wire and uncomfortable and inappropriate electrode to long-term attachment. Even if the wireless communication is used for healthcare garment system, the interface between sensors and circuits have to use wires. To solve these problems, this paper use electrode using PEDOT coated PVDF nanoweb for ECG signal and PVDF film sensor for respiratory signal. And, we constructed garment network using digital yarn of 10um, and transmitted ECG and respiratory signal to mobile phone through the integrated circuit with bluetooth called station To evaluate feasibility of the proposed mobile healthcare garment system, we experimented with transmission and measurement of ECG and respiratory signal using nanoweb electrode and digital yarn. We got a successful result without noise and attenuation.

Effect of High Pressure on Polarographic Parameters of Metal Complex Ion (金屬錯이온의 폴라로그래피的 파라미터에 미치는 壓力의 影響)

  • Heung Lark Lee;Zun Ung Bae;Jong Hoon Yun
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.444-451
    • /
    • 1987
  • The dependence of polarographic parameters on the pressure for the reduction of copper(II), cadmium(II), and zinc(II) complex ions with ethylenediamine, propylenediamine, and diethylenetriamine has been studied. In this study the dropping mercury electrode, the mercury pool electrode, and helix type of platinum wire were used as the working, the reference, and the auxilary electrode, respectively. With increasing the pressure from 1 atmosphere to 1,500 atmospheres, the reduction half-wave potentials of metal complex ions are shifted to the negative values and the diffusion currents become considerably larger, in keeping with the theory on the change of the physical properties of the electrolytic solution such as the density, the viscosity, the dielectric constant, and the electrical conductance, etc. The slope values of the logarithmic plot are increased with increasing the pressure, which indicates the more irreversible reduction. The temperature coefficients of diffusion current observed over the range of the temperature from 25$^{\circ}$C to 35$^{\circ}$C are about two percentage with increasing the pressure, therefore the polarographic reduction under the high pressure is controlled by diffusion. The linear relationships between diffusion current and concentration of metal complex ions are established over all pressure range.

  • PDF

Effect of High Pressure of Voltammetric Parameters of Copper (구리의 전압전류법적 파라미터에 미치는 압력의 영향)

  • Zun Ung Bae;Heung Lark Lee;Hong Soon Park
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.4
    • /
    • pp.399-405
    • /
    • 1989
  • The dependence of voltammetric parameters on the pressure for the reduction of Cu(II) in 0.5M KCl aqueous solution has been studied. In this system micro platinum electrode, standard calomel electrode and a helix type of platinum wire were used as the working, the reference and the auxilary electrode, respectively. With increasing the pressure from 1 to 1,800 bars, the half wave potentials of first reduction wave are shifted to the more negative potentials. And the diffusion currents of first and second reduction wave become considerably larger with increase in pressure from 1 to about 1,000 bars but are getting smaller beyond 1,000 bars. The good linear relationships between diffusion current and the concentrations of Cu(II) are established over all pressure range($1{\sim}1,800$ bars). The reversibility of the each reduction step is not changed with increasing pressure.

  • PDF

Variation of Performance with Operation Condition of Benthic Microbial Fuel Cells (저생 미생물 연료전지(BMFC)의 구동조건에 따른 성능 변화)

  • Oh, So-Hyeong;Kwag, Ha-Won;Lee, Ye-Jin;Kim, Young-Sook;Chu, Cheun-Ho;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.57 no.2
    • /
    • pp.172-176
    • /
    • 2019
  • A benthic microbial fuel cells(BMFC) is fuel cell using electricity produced by decomposing organic matter in a sea or a lake. In this study, we used a gas diffusion layer (GDL) of a polymer electrolyte fuel cell (PEMFC) as a BMFC electrode to find out the operation conditions with high performance. The performance of BMFC was increased as resistance of external resistor increased. It was possible to maintain the performance by avoiding the increase of the contact resistance with the electrode due to corrosion of the lead wire in seawater. The bubble generator was able to increase the maximum power density by more than 2 times and the optimum operating temperature was $40^{\circ}C$.

Beam stability improvement of a liquid metal ion source (액체 금속 이온원의 빔 안정도 향상)

  • 현정우;임연찬;김성수;박철우;이종항;강승언
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.504-507
    • /
    • 2004
  • Previous studies on the liquid Gallium ion sources used an electro-chemically etched tungsten wire with a coil-type heater. Such a structure requires excessive power consumption in the course of heating the liquid metal. In this work, a new structure is proposed that replaces the coil-type heater. It uses a Gallium reservoir made of six pre-etched 250 $\mu\textrm{m}$ tungsten wires that surround the needle electrode. Gallium loading at the reservoir is observed to be much more stable, resulting in an improved beam stability.

  • PDF

Preparation of crack-free YBCO films by EPD on silver

  • Soh, Deawha;Li, Yingmei;Korobova, N.
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.359-362
    • /
    • 2003
  • Electrophoretic deposition (EPD) of alcohol YBCO suspensions on the Ag wire electrode is studied. Poly(ethylene glycol) was coordinated to a structure formed by the EPD process with YBCO particles. The suspension is characterized in terms of zeta potential and conductivity. The d.c electric fields of 200-300 V/cm are applied for 1-10 min. The optimal condition for the EPD allows modifying the properties and microstructure of the deposited films. Superconducting coatings with nanometer-sized pores and a preferred orientation along the c-axis were prepared from the result with chemically modified precursor solution. In contrast, YBCO coatings of submicrometer-sized pores and randomly orientated grains were prepared from the solution without PEG.

  • PDF