• 제목/요약/키워드: window energy

검색결과 687건 처리시간 0.03초

표면 온도 저하율에 따른 창호부 결로성능 예측에 관한 연구 (Study on Estimate of Window Condensation performance Due to Temperature Depreciation Ratio)

  • 성욱주;조수;장철용;이진성;백상훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1255-1260
    • /
    • 2006
  • This present study analyzed temperature depreciation ratio of window inside surface by KS F 2295 'Procedure for determining fenestration product condensation resistance values'. it estimated window indoor surface condensation due to variable environmental condition. Performance of condensation resistance by using temperature depreciation ratio until applied Low-e and Ar glazing improved about 45% from 24 mm clear. Temperature depreciation ratio by KS F 2295 considers analytic index of window condensation due to variable boundary condition.

  • PDF

공기 전도형 출력을 갖는 정원창 자극형 인공중이의 출력방식 제안 (A Proposal of Output Method of Round Window Stimulation Type Middle Ear Implants using Acoustic Transmission)

  • 성기웅;이규엽;김명남;조진호
    • 한국멀티미디어학회논문지
    • /
    • 제21권6호
    • /
    • pp.678-684
    • /
    • 2018
  • In order to broaden the indication of middle ear implant, research has been actively conducted on the reverse output method that stimulates the round window. However, it is very difficult to transmit the vibration output effectively because the indivisual anatomical difference of the round window niche is very large and also the visual field is not secured even by a skilled otolaryngologic surgeon. In this paper, we propose a new reverse stimulation method of middle ear implants that transmits energy to the inner ear by using air as a medium. This can compensate for the disadvantages of the conventional method of transmitting vibration energy and minimizes the energy transfer efficiency interference due to the combination of the excitation point and the output device. It was shown that forward and backward transfer characteristics were obtained by cadaveric experiments, and it was shown that it can overcome the acoustical impedance of high round window and transmit energy to inner ear. The receiver, which is the output device of the conventional hearing aids, can generate a constant volume velocity, so it can have a high output at a limited volume, such as a round window niche. So, suggested method can overcome the high acoustical impedance of the round window and deliver acoustic energy to the inner ear.

수평 구름 바퀴가 적용된 신 유형 미서기 창문의 기밀성능 개선에 관한 연구 (A Study on the Enhance of Air tightness Performance of a New Type Silding Window with horizontally Rolling Wheels)

  • 장혁수;김영일;정광섭
    • 에너지공학
    • /
    • 제24권4호
    • /
    • pp.63-70
    • /
    • 2015
  • 창문에서의 틈은 열 손실 뿐만 아니라 차음 성능에도 중대한 결함으로 작용되며, 특히 인체에 유해한 미세먼지 유입 경로로도 작용된다. 이러한 틈을 제거하기위해 많은 시도들이 이루어지고 있으나, 창문의 고유 기능인 이동특성으로 인해 해결하기 어려운 난제로 인식되어왔다. 본 연구는 이를 해결하기위해 수평 회전 휠과 곡선 레일을 적용한 새로운 유형의 미서기 창문을 제작하고, KS 시험 기준에 따라 사용성, 내구성, 기밀성능, 등의 성능 시험을 하였다. 시험 결과, 개폐력은 2000 N 중량의 창문에서 30 N, 개폐 반복성 시험에서는 100,000 cycles, 기밀성 시험에서는 10 Pa에서 $0.00m^3/(m^2h)$의 성능을 보여주었다. 상기 시험 결과, 새로운 구동 방식을 지닌 본 연구에서의 창문은 기밀성과 경제적 측면에서 새로운 접근 방식을 제시하고 있다.

창호를 통한 열전달 현상에 관한 연구 (A Study on the Heat Transfer Phenomenon through the Glazing System)

  • 강은율;오명원;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.32-37
    • /
    • 2009
  • An energy loss through the window system occupies about 10 to 30 percent on energy consumption of the whole building. That is the reason, several elements for a building composition of window system are the weakest from the heat. Insulation performance increases for the reducing heat loss. Heat transfer through the window system that is reducing heat transfer through conduction, convection and radiation. Insulation performance reinforcement methods classify improving heat specific quality of window system and improving efficiency of whole window system. The most application method among each methods is reducing emission ratio of the window system(Low-E glass), increasing a number of glazing(multiple window) and a method of vacuuming between glazing and glazing. Therefore this study is investigated a sort of glazing and specific character, U-value calculation with changing glazing thickness and calculation of temperature distribution and U-value with a glazing charging gas kind from double glazing. For a conclusion, an aspect of U-value figure at the smallest value case of vacuum glazing with Low-E coating. That means insulation efficiency is the best advantage during a building plan selecting vacuum glazing with Low-E coating for a energy saving aspect. In this way, U-value become different the number of glazing, coating whether or not and selecting injection gas. Therefore selecting of glazing is very important after due consideration by a characteristic and use of building and consideration of strong point and weak point.

  • PDF

단열셔터를 적용한 구동창호의 에너지 절감 및 야간 난방성능 분석 (Analyses of Energy Savings and Night Heating Performance of a Movable Thermal Insulation Shuttered Window)

  • 이장만;조수;임상훈;송규동
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.150-155
    • /
    • 2013
  • Usually, a window tends to have a lower thermal performance, than that of an ordinary wall. This study analyzes the enhancement of thermal performance of a window, when a Thermal Insulation Shutter is installed. The analyses were conducted at the laboratory, and with a full-scale mockup house, and the U-factor and heating load were examined. The laboratory results show that the U-factor increased by approximately 28%, when a Thermal Insulation Shutter was installed. The temperature difference was about $5^{\circ}C$, and this shows that the Thermal Insulation Shutter enhances the thermal performance of the window, when installed. The mockup house was used to calculate the heating load; the heating load was reduced by more than 41%, and shows that the installation of a Thermal Insulation Shutter is an effective way to reduce heating energy consumption.

The verification about possibility of introducing Window to Floor Ratio as design index for building energy performance

  • Choi, Won-Ki;Lee, Yong-Jun;Lee, Hyun-Soo;Eom, Jae-Yong;Lee, Chung-Kook
    • KIEAE Journal
    • /
    • 제17권1호
    • /
    • pp.23-28
    • /
    • 2017
  • Purpose: Many design index that are using in planning phase have been developed. The most popular things among them are Window to Wall Ratio and Surface to Volume Ratio. However there are some limits. Window to Wall Ratio cannot consider building size and Surface to Volume Ratio cannot do Window to Wall Ratio. Accordingly, in this paper, the Window to Floor Ratio was proposed that it can be considered both building size and Window to Wall Ratio. And analyzed correlation of energy demand. Method: For the test, 16 modules with the size of $6m{\times}6m{\times}4m$ were used to make 35 models with the same volume. The simulation was conducted to 945 cases using the window-to-wall ratio of 30, 50 and 70 % in three areas such as Seoul, Gwangju and Jeju and three kinds of windows. And IES_VE was used. Result: The findings above show that the Window to Floor Ratio that can be considered both building size and Window area have to become as design index. It was found out that design criteria with SHGC is necessary, not with the thermal performance (U-value). It is needed to additional analysis about residential building and the effect of 24-hours heating and cooling condition. It plans to carry out research to establish design indicators for climatic conditions in the country and building applications.

건물에너지 절감을 위한 열차단 필름의 성능 평가 (Thermal Performance Evaluation of The Window Film Insulation for Building Energy Savings)

  • 남중우;원종서
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.75-80
    • /
    • 2008
  • Recently, Energy savings in buildings has received much attention in response to the increased needs for global warming and better comforts of the occupants in apartment housing. This study proposes the method which uses the sun control window film to reduce the cooling load and heating load improving the thermal performance of the building and it improves an energy efficiency. The film which used in actual measurement has a low shading coefficient and a solar energy transmission. so we measured the surface temperature of the triple Low-e glazing system used and inside temperature according to the change of outside temperature and solar energy to study thermal performance evaluation. As a result, it was helpful to use window film insulation to reduce inside temperature in summer and to keep room warm in winter.

  • PDF

창호 에너지소비효율등급제에 따른 공동주택의 열성능 평가 (Energy Performance Evaluation of Apartment Houses According to Window Energy Consumption Efficiency Rating System in Korea)

  • 임희원;김동윤;이수만;안정혁;윤종호;신우철
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.159-166
    • /
    • 2018
  • The Korean fenestration energy consumption efficiency rating system only considers thermal performance of the heat transfer coefficient (U-value) and airtightness excluding optical characteristics of the solar heat gain coefficient (SHGC). This study analyzed annual heating and cooling energy requirements on the middle floor of apartment by optical and thermal performance of windows to evaluate the suitability of the rating system. One hundred and twenty-eight windows were analyzed using THERM and WINDOW 7.4, and energy simulation for a reference model of an apartment house facing south was performed using TRNSYS 17. The results showed that window performance was the main factor in the heating and cooling load. The heating load of the reference model was 539 kWh to 2,022 kW, and the cooling load was 376 kWh to 1,443 kWh. The coefficient of determination ($R^2$) of the heating and cooling loads driven from the SHGC were 0.7437 and 0.9869, which are more compatible than those from the U-value, 0.0558 and 0.4781. Therefore, it is not reasonable to evaluate the energy performance of windows using only the U-value, and the Korean fenestration energy consumption efficiency rating system requires a new evaluation standard, including SHGC.

Dynamic Adjustment of Ad hoc Traffic Indication Map(ATIM) window to save Power in IEEE 802.11 DCF

  • Nam, Jae-Hyun
    • Journal of information and communication convergence engineering
    • /
    • 제6권3호
    • /
    • pp.343-347
    • /
    • 2008
  • Wakeup schemes that turn off sensors' radio when communication is not necessary have great potential in energy saving. At the start of each beacon interval in the IEEE 802.11 power saving mode specified for DCF, each node periodically wakes up for duration called the ATIM Window. However, in the power saving mechanism specified in IEEE 802.11, all nodes use the same ATIM window size. Since the ATIM window size critically affects throughput and energy consumption, a fixed ATIM window does not perform well in all situations. This paper proposes an adaptive mechanism to dynamically choose an ATIM window size according to network condition. Simulation results show that the proposed scheme outperforms the IEEE 802.11 power saving mechanism in terms of the amount of power consumed and the packet delivery ratio.

PV 일체형 차세대 스마트 윈도우 기술개발 동향 (Technology Development Trends of Self-Powered Next Generation Smart Windows)

  • 변선호
    • 한국전기전자재료학회논문지
    • /
    • 제28권12호
    • /
    • pp.753-764
    • /
    • 2015
  • Among several types of energy saving smart window technologies, the leader, the dynamic EC (electrochromic) window one needs integrated PV (photovoltaics), to minimize expensive electrical wiring as well as to obviate the need for external energy. Self-powered smart windows were reviewed according to PV types used. DSSCs (dye sensitized solar cells) were found to be compatible with EC cells, to have several categories of next generation smart windows such as PECCs (photoelectrochromic cells), PVCCs (photovoltachromic cells), EC polymer PECCs. In addition silicon solar cells and third generation solar cells were investigated. They are summarized in a table showing their advantages and disadvantages respectively for a fast comparison. The strategy to expedite the commercialization of these next generation smart windows includes developing retrofit smart window coverings for use on flexible polymer substrates adhered to the inside surface of a window and easily replaced after use for upto 10 years.