Analyses of Energy Savings and Night Heating Performance of a Movable Thermal Insulation Shuttered Window  

Lee, Jang-Man (Department of Environmental Engineering of Architecture, Hanyang University)
Cho, Soo (Department of Building Energy, Korea Institute of Energy Research)
Lim, Sang-Hoon (Department of Building Energy, Korea Institute of Energy Research)
Song, Kyoo-Dong (School of Architecture and Architectural Engineering, Hanyang University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.25, no.3, 2013 , pp. 150-155 More about this Journal
Abstract
Usually, a window tends to have a lower thermal performance, than that of an ordinary wall. This study analyzes the enhancement of thermal performance of a window, when a Thermal Insulation Shutter is installed. The analyses were conducted at the laboratory, and with a full-scale mockup house, and the U-factor and heating load were examined. The laboratory results show that the U-factor increased by approximately 28%, when a Thermal Insulation Shutter was installed. The temperature difference was about $5^{\circ}C$, and this shows that the Thermal Insulation Shutter enhances the thermal performance of the window, when installed. The mockup house was used to calculate the heating load; the heating load was reduced by more than 41%, and shows that the installation of a Thermal Insulation Shutter is an effective way to reduce heating energy consumption.
Keywords
High energy efficiency; Thermal insulation shutter; Thermal transmittance; Heating load;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 KS F 2278, Test Method of Thermal Resistance for Windows and Doors.
2 Cho, S., 2012, A Study on Thermal Performance Simulation and Evaluation of the Window Combined with Thermal Insulating Shutter, Architectural Institute of Korea, Vol. 28, No. 10, pp. 327-334   과학기술학회마을
3 Kim, C. N., 2010, A Study on the Reduction Performance of Building Energy Demand by Using the Shading Device Control, Korea Institute of Ecological Architecture and Environment, Vol. 10, No. 2, pp. 303-306.
4 Choi, G. S., 2010, Performance Evaluation of Apartment Building in Case of Applying a Blind Integrated Window System, Vol. 22, No. 7, pp. 429-435.   과학기술학회마을
5 ISO 7730, Ergonomics of the thermal environment- Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria.
6 Yoo, M. H., 2012, Evaluation on Cooling Performance of Thermally Activated Building System by Insulation and Shading Conditions in Apartments, Journal of the Korean Housing Association, Vol. 23, No. 2, pp. 107-114.   과학기술학회마을   DOI   ScienceOn
7 Park, S. H., 2010, An Analysis of Heating and Cooling Loads by Insulated Shades and Control Method in an Energy Saving Apartment, Vol. 22, No. 6, pp. 392-397.   과학기술학회마을