• Title/Summary/Keyword: window energy

Search Result 693, Processing Time 0.019 seconds

Energy Performance Evaluation of Zero Energy Technologies for Zero Energy Multi-House (공동주택의 에너지 자립을 위한 핵심요소기술의 에너지 성능평가)

  • Yoon, Jong-Ho;Kim, Byoung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.161-167
    • /
    • 2007
  • Zero Energy Multi-House(ZeMH) signifies a residential building which can be self sufficient with just new and renewable energy resources without the aid of any existing fossil fuel. For success of ZeMH, various innovative energy technologies Including passive and active systems should be well integrated with a systematic design approach. The first step for ZeMH is definitely to minimize the conventional heating and cooling loads over 50% with major energy conservation measure and passive solar features which are mainly related to building design components such as super-insulation, super window, including infiltration and ventilation issues. The purpose of this study is to analyze the thermal effect of various building design components in the early design of ZeMH. The process of the study is presented in the following. 1) selection reference model for simulation 2) verification of reference model with computer simulation program(ESP-r 9.0). 3) analysis of effect according to insulation-thickness, kinds of windows, rate of infiltration. and The simulation results indicate that almost 50% savings of conventional heating load in multi-house can be achieved with the optimum design of building components such as super insulation, super window, infiltration, ventilation.

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (기존 노후건축물의 최적 리모델링 개선안 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Oh, Se Min
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.207-216
    • /
    • 2014
  • The energy loss can be divided into the loss caused by heat transfer and the loss caused by air flow. Heat transfer is the loss resulting from the heat transmittance of external wall, roof, and floor, and represents one of the most vulnerable elements of existing buildings. To prevent such loss, it is necessary to increase the mean heat transmittance of entire external wall, including the window, to a level above the standard regional value and ensure the air-tightness of window. The old buildings have the structure which is prone to the loss of greater air flow due to the air infiltration through the exit/entrance door upward along the stairway by the stack effect and simultaneous suction of air from each floor, and becomes even vulnerable to the loss of heat insulation for each floor, although the external wall and windows are the most vulnerable parts. The improvement plans for each floor need to be submitted in tandem with the diagnosis of whole building, regarding the diagnosis plan and energy improvement measures based on the survey of site, rather than adhering to the misconception that the replacement of window alone will result in energy-savings.

Window Integrated Solar Collectors (창호일체형 태양열 집열기)

  • Park, Seong-Bae;Lim, Seong-Whan;Park, Mann-Kwi
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.61-65
    • /
    • 2009
  • Window integrated solar collector is to simply install inside of the existing double glass window frame. Double glass window frame is consist of inner glass of Low-E coating and Silver coating, and outer glass of low iron reinforced glass. In order to secure natural lighting in a room, only 50% of window frame is covered with solar collectors. Solar absorption or transmission rate varies seasonally depending on sun angles. Part of inner glass where right behind of the solar plate is covered with silver coating to increase absorption rate of solar plate. The collector is made of a copper serpentine where aluminum fins are soldering. To improve the effect of insulation of inside of the window frame is recommend vacuum. As a result, we are making the 3th sample and will archieve below $F_RU_L=7.5W/m^2^{\circ}C$ that is the account of heat lossed, and above $F_R({\tau}{\alpha})=0.45$.

  • PDF

A Study on the Simulation of Natural Ventilation Effect for Single-sided Casement Window as Opening Types (케이스먼트 창호 개폐방식에 따른 자연환기 효과에 관한 시뮬레이션 연구)

  • Choi, Taehwoan;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.57-62
    • /
    • 2007
  • At the moment, the reduction of building energy consumption is a unavoidable task of mankind for conserving global environment. Decreasing overall U-value of building envelope and air infiltration, especially in Korean climate condition with clear four seasons, are the obvious solutions for the objective. Thus low glazing ratio with small window openings are required for heating and cooling load reduction in buildings. Using larger window openings could provide better natural ventilation but it also increases the direct solar radiation penetration into indoor space, heat gain in summer and heat loss in winter. On the other hand, the ventilation rates decreasing problem with smaller window openings could be occurred. As a solution for it, the use of casement window can cause increasing natural ventilation rates by wing wall effect. This paper focuses on deduce the most efficient opening type of casement window in Korean climate. To estimate ventilation performance of each opening types, CFD simulation was used. The best performance of opening type in every wind direction is opening both windows to the center and the most appropriate opening type for Korean climate is also opening both windows to center.

Effects of Different Fenestration Configurations on Daylighting Performance in Unilateral Window under Clear and Overcast Sky Conditions (편측창에서 창개구부의 형상이 천공상태별 채광성능에 미치는 영향)

  • Azmiree, Sultana;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.105-113
    • /
    • 2009
  • Daylighting provides the opportunity for both energy savings and improved visual comfort. An accurate estimation of the amount of daylight entering a building is the key step for daylight designing. This research aims to assess comparative daylighting performance of four different configurations of fenestration in case of unilateral windows and their variation under clear and overcast sky conditions. The selected window openings in this study were single punched, double punched, multiple punched and clerestory, and the area was same for each type of window. The experiment was designed for an office space using 1/10 scale model. Daylighting performance was evaluated by measuring the illuminance on work-plane height using Agilent data logger and photometric sensor Li-Cor. Thecomputer program ECOTECT was also used to simulate the pattern of interior illuminance distribution. Clerestory window showed the best performance in term of both illuminance level and distribution in the experiment. Multiple punched window provided more uniform illuminance distribution than single punched window. Lowest daylighting performance in the experiment was shown by double punched window.

Prediction of Reduction Rates of Daylight Illuminance for Blind Conditions in a Small Office (소규모 사무실의 블라인드 조건에 따른 주광조도 감소비율 예측)

  • Gu, Renyan
    • Land and Housing Review
    • /
    • v.12 no.2
    • /
    • pp.79-89
    • /
    • 2021
  • This simulation based study analyzed the horizontal daylight distribution on the floor and ceiling of a small office space based on window orientations and interior window blind positions. South and north facing windows were each tested without window blinds and with window blinds at 45° and 180° (horizontal). The study showed that the illuminance value was highest 1m from the window. On the floor and ceiling, the difference in illuminance value was the greatest and least in December and June, respectively. The indoor illuminance value was highest when there was no window blind and under south-facing conditions. The greatest illuminance difference occurred between window blinds positioned at 45° and 180°. Under north-facing conditions, windows without blinds or with blinds at 45° had the least impact on indoor illuminance with illuminance being more evenly distributed.

An Experimental Study on Relationship Between Temperature Change and Generation Performance of a-Si BIPV Window System (박막 BIPV창의 온도변화와 발전성능 상관관계에 관한 실측연구)

  • Kim, Bit-Na;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.179-184
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temperature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish monitoring system and analysis the data from the monitoring system to evaluate the performance of PV windows that have thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

Analysis of Generating Efficiency in PV Window System consequent on Apartment House Wall Reflectivity (공동주택 벽체 반사율에 따른 PV창호시스템 발전효율 분석)

  • Choi, Doo-Sung;An, Jun-Ho;Jeon, Hung-Chan;Do, Jin-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.2
    • /
    • pp.31-39
    • /
    • 2016
  • This study did quantitative comparative evaluation of changes in generation consequent on reflectivity of the protruding wall near the widow in case of application of PV window system to an apartment house. To be concrete, this study did comparative analysis of the generation of (B) through the process of composing Mock-up (A)comprising the protruding window near the window and Mock-up(B) free of nearby wall interference, and giving change to the reflectivity of the wall (Case_1~3). The analysis result showed that the difference in generation was slight in case solar radiation was less than 10,000Wh in all three conditions. On the contrary, in case solar radiation was more than 10,000 Wh, the generation as against Module(B), was analyzed to be 87~91% in Case_1(5% reflectivity), 18~60% in Case_2(85% reflectivity), and 16~71% in case_3(93% reflectivity), respectively.

A Study on Change in Window Transmitted Solar and the Resultant Wall Surface Convective Heat Gain with Regard to Slat Reflectance of External and Internal Blinds (실내·외 블라인드의 Slat 반사율에 따라 창호 일사투과량 및 그에 따른 벽체 대류열획득량 분석)

  • Hyun, In-Tak;Lee, Jae-Ho;Yoon, Yeo-Beom;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.565-571
    • /
    • 2014
  • Nowadays, to make buildings light weight and aesthetically pleasing, curtain wall structure are commonly used. Therefore, window to wall ratio is increasing, which has caused cooling and heating load in crease in buildings as well. This phenomenon has negative impact from energy point of view. This paper analyzes window and wall convective heat gain when the slat reflectance of external and internal blinds are changed for the better understanding of the fundamentals behind the phenomena. It was observed that, if slat reflectance is increased, window transmitted solar increases and convection heat rate is clearly affected. Among six surfaces including four walls, ceiling and floor, maximum convection heat rate occurs on the south wall in summer. On the other hand, ceiling and floor showed the lowest convection heat gain, since they are shared by adjacent floors.

The Efficiency Analysis of Firms Having Established a Business Intelligence System Using DEA/Time-Window Analysis (DEA를 이용한 기업의 Business Intelligence 시스템 도입 효율성에 대한 비교 평가 연구)

  • Baek, Seong-Hyun;Park, Kwang-Ho;Kim, Tai-Young
    • Information Systems Review
    • /
    • v.17 no.3
    • /
    • pp.113-133
    • /
    • 2015
  • In this paper, DEA analysis is employed to compare and evaluate the relative efficiency of a business intelligence (BI) system among five industrial groups such as IT and financial services, electricity and electronics, energy and chemistry, automotive and heavy machinery, and food and apparel. Especially, this study has analyzed the improving tendency of relative efficiency of the industrial groups since they adopted the BI System using Time-Window Analysis. The research findings show that the energy and chemical industry group tends to be remarkably more efficient than the other groups and the electrical and electronic industry turns out to gradually improve their efficiency since the adoption of the BI system.