Browse > Article
http://dx.doi.org/10.7836/kses.2016.36.2.031

Analysis of Generating Efficiency in PV Window System consequent on Apartment House Wall Reflectivity  

Choi, Doo-Sung (Department of Building Equipment & Fire Protection System, Chungwoon University)
An, Jun-Ho (Department of Architectural Engineering, Suwoon University)
Jeon, Hung-Chan (Department of Architectural Engineering, Suwoon University)
Do, Jin-Seok (Department of Architecture, Yeoju Institute of Technology)
Publication Information
Journal of the Korean Solar Energy Society / v.36, no.2, 2016 , pp. 31-39 More about this Journal
Abstract
This study did quantitative comparative evaluation of changes in generation consequent on reflectivity of the protruding wall near the widow in case of application of PV window system to an apartment house. To be concrete, this study did comparative analysis of the generation of (B) through the process of composing Mock-up (A)comprising the protruding window near the window and Mock-up(B) free of nearby wall interference, and giving change to the reflectivity of the wall (Case_1~3). The analysis result showed that the difference in generation was slight in case solar radiation was less than 10,000Wh in all three conditions. On the contrary, in case solar radiation was more than 10,000 Wh, the generation as against Module(B), was analyzed to be 87~91% in Case_1(5% reflectivity), 18~60% in Case_2(85% reflectivity), and 16~71% in case_3(93% reflectivity), respectively.
Keywords
Photovoltaic windows system; Apartment; Reflectivity; Amorphous module;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Yoon. J. H, An. Y. S, Song. J. H, Kim. S.G, Lee. S. J and Chung. Y. K, A Study on the Power Performance Measurement of Transparent Thin-film PV Windows Depending on the Inclined Angle, Journal of the Architectural Institute of Korea, Vol. 24, No. 9, pp. 271-278, 2010
2 Han. J. K., Lee. M. S and Lim. H. S, A Study on the performance of the Application of Building Integrated Photovoltaic System, The Annual Conference for Architectural Institute of Korea, Vol. 29, No. 1, pp. 343-346, 2009
3 Park. K. E, Study on the Performance Characteristics of Semi-Transparent BIPV Modules for Glazing, a doctor's thesis, Depart of Architectural Engineering, A Kongju National University, Republic of Korea, 2010
4 Kim. M. S, Annual energy yield prediction of building added PV system depending on the installation angle and in Korea, a master's thesis, Depart of Architectural Engineering, Hanbat National University, Republic of Korea, 2013
5 LEE, K. J, A Study on the Electric Performance Evaluation of Variable PV Lightshelf by the Field Experiment, a master's thesis, Depart of Architectural Engineering, Korea National University of Transpotation, Republic of Korea, 2014
6 Jeong. S. Y, Kim. S. W and Yeo. H. S, Color Image Analysis of the Apartment Exterior Color according to the Gwanggyo New Town Color Guideline, Korea Design Knowledge Journal, Vol. 34, pp. 25-34, 2015
7 http://innocity.mltm.go.kr/
8 http://www.seoul.go.kr
9 http://ebook.gg.go.kr
10 http://www.nyj.go.kr
11 http://design.seongnam.go.kr
12 http://www.uw21.net/kr/guide
13 Department of Energy, DOE 2.1E Manual, 1991.08
14 Song. J. H, Yoon. J. H, An. Y. S, Kim. S. G, Lee. S. J, and Choung. Y. K, Power Performance Characteristics of Transparent Thin-film BIPV Module depending on an installation angle, Journal of the Korean Solar Energy Society, Vol. 28, No.2, pp. 58-63, 2008