유한요소법에 의한 변압기 인덕턴스 계산 (The Calculation of Transformer Inductance by the Finite Element Method)

  • 배진호;노채균
    • 대한전기학회논문지
    • /
    • 제34권7호
    • /
    • pp.267-275
    • /
    • 1985
  • The finite element method for calculating single phase transformer inductance is presented in this paper. There are three basic definitions of saturated transormer inductance. The set of nonlinear finite element equations is solved by the Newton-Raphson method which assures nearly quadratic convergence of the iteration process. The effect of perturbation of currents of this transformer is used to calculate the saturated winding inductance. This approach is used to calculate the apparent, effective and incremental inductance of single phase transformer. The apparent inductance is in good agreement with resting result. The approach enabled one to study the variation of winding inductance according to the saturation levels in the core at any operating point.

  • PDF

배전용 FRP전주의 기계적 및 환경성능 (Mechanical and Environment Ability of FRP Pole for a Distribution Line)

  • 박기호;조한구;한동희;이웅선;송일근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.395-398
    • /
    • 2000
  • In this study mechanical and environment ability of FRP pole for a distribution line about high strength and good insulation properties. The basic filament winding process creates a helical winding pattern. In mechanical analysis of splice with mechanical fastened joint it is important to evaluate a critical load of faster having maximum stress. It is also present a result of several examples to compare this with analytical one. On repair design this finite element method will be used as basis. The influence of environmental factors, such as elevated temperatures, high humidity, and corrosive fluids, and ultraviolet(UV) rays, upon the performance of polymeric matrix composite is of concern in many applications.

  • PDF

양측 여자형 LDM의 다권선화에 관한 연구 (A study with multi-winding of double excited type LDM)

  • 이승명;백수현;김용;윤신용;맹인재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.290-293
    • /
    • 2000
  • In this paper, by designing the width of the stator coil, double sided excitation LDM with multi-separated winding which is possible to obtain the constant thrust force is proposed. Using Permeance method, equvalent magnetic circuit method, Maxwell 2D, which is the magnetic field analysis package, we were analyzed and proved the validity of design process, also the characteristics of LDM according to magnet vs. coil width ratio of LDM was almost in accord with the experiment results.

  • PDF

무 구속·구속 실험에 의한 환풍기 온도 특성 (The Characteristic of Temperature in Ventilating Fans by Festraint or Nonrestraint)

  • 김성삼
    • 조명전기설비학회논문지
    • /
    • 제30권1호
    • /
    • pp.44-48
    • /
    • 2016
  • In this paper, we analyzed the operating characteristics of a ventilating fan due to overload and overheating. The experiment assumed the forcible restraint of the blade due to external objects and the aging process. We analyzed the experimental temperature and operating characteristics of the three places in the interior of the ventilating fan. As a result of the analysis, the temperature distribution was highest to lowest in the following order: the thermal fuse, the motor inside, and the above winding. There was smell of burning enamel in the restraint experiment. Following the thermal fuse operation, the insulation of motor winding was good. In the case of rated voltage and new ventilating fan restrained for about 4hours, and the results of restraint experiments in the presence or absence of the thermal fuse, no risk of deformation or fire due to overheating was identified. Henceforward, ignition hazard experiments will be required for additional factors of aging, pollution, and defective insulation.

교류 발전기 고정자 사고 검출을 위한 최적 마더 웨이브릿의 선정 (A Selection of an Optimal Mother Wavelet for Stator Fault Detection of AC Generator)

  • 박철원
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.377-382
    • /
    • 2008
  • For stator winding protection of AC generator, KCL(Kirchhoff's Current Law) is widely applied. Actually a CRDR(Current Ratio Differential Relay) based on DFT(Discrete Fourier Transform) has been used for protecting generator. It has been pointed out that defects can occur during the process of transforming a time domain signal into a frequency domain one which can lead to loss of time domain information. Wavelets techniques are proposed for the analysis of power system transients. This paper introduces an algorithm to choose a suitable Mother Wave1et for generator stator fault detection. For optimal selection, we analyzed db(Daubechies), sym(Symlets), and coif(Coiflects) of Mother Wavelet. And we compared with performance of the choice algorithm using detail coefficients energy and RMS(root mean square) error. It can be improved the reliability of the conventional DFT based CRDR. The feasibility and effectiveness of the proposed scheme is proved with simulation using collected data obtained from ATP (Alternative Transient Program) package.

대형 터빈 발전기용 고정자 권선의 1000 thermal cycle 후 전기적 특성 변화 (Electrical Degradation of Stator Bars for Large Turbine Generator after 1000 Thermal Cycles)

  • 강명국;김태희;이재권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.975-976
    • /
    • 2007
  • Thermal and mechanical stresses, caused by repetitive start and stop and load fluctuation during long time operation, on winding stator bars are one of the main causes for electrical degradation of insulating materials. To understand the degradation process, we manufactured bar specimens with the same processes that make generator winding stator bars and the specimens were subjected to various degrees of thermal cycling. Measurements of the insulation properties, such as dissipation factor, tip-up and partial discharge, for un-aged specimens and for specimens aged by thermal cycling at 50, 100, 250, 500 and 1000 thermal cycles were performed. Finally all specimens were tested to obtain electrical breakdown voltages. In this paper we present the data and electrical degradation analysis results obtained during this program.

  • PDF

웹 표면 수직방향으로 기우러진 롤에 의한 측 방향 웹 거동에 대한 연구 (A study on the lateral Dynamics of the Moving Web Induced by a Tilted Roller)

  • 신기현
    • 한국정밀공학회지
    • /
    • 제17권12호
    • /
    • pp.209-216
    • /
    • 2000
  • The lateral behavior of the moving web is critical to the quality of the web products. The alignment of the rollers carrying the web is found to be one of important factors to the lateral behavior of the moving web. But, the study on the effect of the tilting roller in the direction of the normal to the moving web on the lateral behavior has not been reported in the literature yet. For example, the contact roller often contacts the winding roll in a tilted fashion and causes the lateral motion of the winding web, which induces the offset on the wound roll. The lateral dynamics of the moving web induced by a tilted roller in normal direction of a web is investigated in this paper. The two-dimensional dynamic model developed by Shelton is extended to investigate the effect of a titled roller in a normal direction of the moving web on the lateral motion of the moving web. New boundary conditions are developed to solve the extended model. Computer simulation study proved that the model developed can be used to predict the lateral motion of the moving web ? to a tilted roller in normal direction of the moving web. The lateral deflection is increased exponentially a the tilting angle is increased. As the length of web span is increased, the amount of lateral deflection was increased almost linearly for the same tilting angle. The lateral dynamics turned out to be almost independent to the operating tension. The model developed can be used to solve the offset problem of the staggered winding and also to design a new web guiding mechanism.

  • PDF

FRP-콘크리트 합성말뚝의 개발 (Development of the Hybrid CFFT Pile)

  • 최진우;주형중;남정훈;윤순종
    • 복합신소재구조학회 논문집
    • /
    • 제1권2호
    • /
    • pp.20-28
    • /
    • 2010
  • 이 논문에서는 기존의 CFFT(Concrete Filled FRP Tube) 복합재 말뚝의 휨강성을 확보하기 위한 새로운 복합재 말뚝형식을 제안하였다. 기존의 CFFT 복합재 말뚝은 필라멘트와인딩 공정으로 제작한 FRP를 사용하기 때문에, 압축력이 편심재하될 경우 휨거동에 대한 안전성을 확보하기 위해 철근 등 별도의 보강재를 필요로 한다. 이 연구에서는 별도의 보강재 없이 휨거동에 대한 저항성을 확보하기 위하여 펄트루젼 방식으로 제작된 FRP를 CFFT 외부에 원주방향으로 부착시킨 FRP-콘크리트 합성말뚝(Hybrid CFFT, HCFFT)을 제안하였다. 이 논문은 HCFFT의 구조적 거동을 검토하기 위한 연구의 일부로서, HCFFT에 사용되는 필라멘트와인딩 FRP의 역학적 특성을 알기 위한 실험을 실시하였다. 또한, 기존 연구 결과를 참조하여 HCFFT의 압축강도를 추정하였으며, 유한요소해석을 통해 얻은 결과와 비교분석하였다.

  • PDF

CFRP 파이프의 와인딩 적층 패턴 설계 및 HNT 나노입자 보강에 따른 수 환경에서의 기계적 물성 평가 (Comparison of Mechanical Properties on Helical/Hoop Hybrid Wound HNT Reinforced CFRP Pipe with Water Absorption Behavior)

  • 최지수;박수정;김윤해
    • Composites Research
    • /
    • 제34권3호
    • /
    • pp.174-179
    • /
    • 2021
  • 유체 이송에 사용되는 강재 파이프는 신설과 도장, 또는 부식과 노후화로 인한 제반 시설 보수에 거대한 규모의 시간과 비용이 요구된다. 이에 본 연구에서는 강재 파이프의 대체재로, 내부식성과 내화학성이 우수한 탄소섬유강화복합재료(Carbon Fiber Reinforced Plastic, CFRP) 파이프 구조의 최적화 설계를 수행하였다. 헬리컬 패턴 표면에 후프 패턴을 혼합적층하여 내구성을 향상시켰으며, 수분 환경에서의 에폭시 흡습 현상을 억제하기 위해, 할로이사이트 나노튜브(Halloysite Nanotube, HNT)를 첨가하였다. HNT/CFRP 파이프는 필라멘트 와인딩 공정으로 제작하였으며, 기계적 물성 시험과 70℃ 고온 증류수 환경하에서 흡습 시험을 진행하였다. 그 결과, 파이프 두께의 0.6%에 해당하는 후프 패턴의 적층 시, 가장 우수한 물성을 나타냈다. 또한 0.5 wt.% HNT 첨가 시 상대적으로 높은 내흡습성을 가졌으며, 층간 계면에서의 박리 현상이 지연되어 가장 낮은 강도 저하율을 보였다.

Type III 수소탱크 경화조건에 따른 잔류응력 비교 (Residual Stress Comparison of Type III Hydrogen Tank by Curing Conditions)

  • 신용철
    • Composites Research
    • /
    • 제37권1호
    • /
    • pp.15-20
    • /
    • 2024
  • 수소탱크의 잔류응력은 내구도와 직접적인 관련이 있기 때문에 안전을 위해 이를 줄이는 것이 매우 중요하다. Type II~IV 수소탱크는 섬유에 수지를 함침시켜 라이너에 감는 필라멘트 와인딩 공법으로 제작하게 된다. 필라멘트 와인딩에서 잔류응력은 경화조건, 섬유 인장 등에 영향을 받게 되는데, 본 연구에서는 탄소섬유 필라멘트 와인딩 공정을 이용한 Type III 수소탱크 제작 시 경화조건이 잔류응력에 미치는 영향을 분석하였다. 먼저 에폭시 수지의 경화거동을 시차주사열량계를 이용하여 분석하였다. 이를 통해 경화온도를 140℃로 설정하였다. 같은 경화시간 동안 140℃에 먼저 도달하는 2-stage 경화조건과, 보다 늦게 도달하는 4-stage 경화조건으로 각각 시편을 경화시켰다. 경화 후 복합재 부분의 잔류응력을 ring slitting 법으로 측정하였고, 이 실험값을 수치해석적인 값과 비교하였다. 그 결과, 경화조건 최적화에 따른 유의미한 잔류응력의 차이가 발생함을 확인하였다.