• 제목/요약/키워드: winding number

검색결과 194건 처리시간 0.035초

다중브리지로 구성된 UPQC(Unified Power Quality Conditioner)의 동적 성능분석 (Dynamic Performance Analysis of Unified Power Quality Conditioner with Cascaded H-Bridges)

  • 한병문;소용철;김현우
    • 전기학회논문지P
    • /
    • 제55권2호
    • /
    • pp.94-102
    • /
    • 2006
  • This paper describes experimental analysis of UPQC, which is composed of cascaded H-bridges and single-phase multi-winding transformers. The operational characteristic was analyzed through experimental works with a scaled model, and simulations with PSCAD/EMTDC. The UPQC proposed in this paper can be directly connected to the distribution line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual UPQC system applicable for the actual distribution system.

치수적 결함에 따른 PMSM의 법선방향 힘의 변화에 관한 연구 (Analysis of Radial Force on a Permanent Magnet Synchronous Motor Caused by Dimensional Variation)

  • 이치우
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1990-1995
    • /
    • 2010
  • Main reasons for causing vibration in a permanent magnet synchronous motor (PMSM) are torque ripple and radial force harmonics, and hence, both of them are undesirable in high-precision machine tools and accurate motion-control actuators. Recent research on radial force is the prediction of major vibration frequencies and modes in terms of motor design such as different winding types and a fractional slot number per pole in the stator. Also, proper phase current has been investigated for minimizing radial force harmonics. During the previous studies, all the motors are assumed to be ideally built up in terms of mechanical dimensions, but it is impossible due to dimensional variation within or outside tolerance in production. Therefore, in this paper, the effect of several key factors on radial force is examined and compared regarding manufacturing imperfection.

최소자승법을 이용한 Y-$\Delta$ 변압기 파라미터 추정 방법 (Parameter Estimation of Y-$\Delta$ Transformer Using the Least Square Method)

  • 강용철;황태근;이병은;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.42-43
    • /
    • 2007
  • This paper proposes a parameter estimation technique of a power transformer. Based on the combined equation, it estimates separately the primary and secondary leakage inductances, winding resistances using the least square method from the instantaneous voltages and currents in the steady state. The performance of the proposed technique was investigated by varying the cut-off frequency of the filter and the number of samples per cycle. The technique estimates the parameters with higher sampling frequencies.

  • PDF

3-레벨 반브리지 인버터로 구성된 새로운 UPFC의 동특성 분석 (Dynamic Characteristic Analysis of Novel Unified Power Flow Controller Using 3-Level Half-Bridge Inverter Modules)

  • 백승택;소용철;한병문
    • 전기학회논문지P
    • /
    • 제53권3호
    • /
    • pp.116-121
    • /
    • 2004
  • This paper proposes a novel UPFC based on 3-level Half-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with EMTDC, assuming that the UPFC is connected with the 138-kV transmission line of one-machine-infinite-bus power system. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of 3-level Half-bridge modules.

HEV용 SRM의 설계 및 구동특성 (Design and Drive Characteristics of SRM for HEV)

  • 김태형;안진우;안영주;문재원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1141-1143
    • /
    • 2005
  • This paper presents the reasonable design parameters of a SRM for hybrid electric vehicle driving. For the design of SRM, the initial model is designed using the equivalent magnetic circuit method. In order to optimize the SRM for HEV. The initial model is redesigned by FEM with the variation of the stock length and turns of winding. This paper shows that a flat-topped current of a phase can be made from a change of the stack length and the number of turns for high efficiency, high average torque and a lower torque ripple. The change of current falling time as a variation of turn-off angle was shown by FEA. The iron loss and copper loss were described. The torque of the redesigned motor is suitable for low and high speed ranges to drive a HEV that was verified by the speed-torque curve.

  • PDF

마찰을 고려한 경편기용 정경빔의 설계에 관한 연구 (A Study on the Design of the Warper Beam Considering Friction)

  • 임문혁;김영규;신현명
    • 한국정밀공학회지
    • /
    • 제20권3호
    • /
    • pp.140-148
    • /
    • 2003
  • An analysis fur the warping process has been performed to design the warper beam. Nonlinear material response is included in the physical model of polyester yarn. Large deformation finite element simulation considering contact and frictional analysis are used to obtain the pressure on the barrel of the warper beam. Loading condition on the flange is assumed by using the pressure on the barrel, winding number of yarn, Poisson's ratio of fiber, and fiber volume fraction. By using the above loading conditions NASTRAN finite element simulation is performed to calculate stress distribution and deformation of the warper beam. By comparing the deformed shape of the flange with experimental result, loading condition on the flange has been obtained. The obtained loading conditions on the barrel and flange can be utilized to design the warper beam.

고압전동기 운전중 부분방전 감시 시스템 개발 (Development of On-Line Partial Discharge Monitoring System in High Voltage Motors)

  • 김희동;공태식;주영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

Numerical Analysis for Characterization of Single Phase Induction Motors by using Circuit Equations Coupled with Magnetic Field Distribution

  • Kim, Young Sun;Lee, Dong Yoon
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.255-259
    • /
    • 2013
  • In this paper a new coupling method for efficient and simple analysis of single phase induction motor is presented. The circuit representation of both the stator winding and each conducting rotor loop (composed of rotor bar and end ring segment) is used in conjunction with the distribution of magnetic flux linkage instead of inductance matrix. The flux linkage is calculated using air-gap flux density distributions driven by unit currents in the stator windings and rotor bars. The field distribution of one turn of a coil is calculated by FEM and the result is used to calculate total flux linkage by employing a coordinate transformation. The numerical results give good agreement with prior literature. The method is particularly effective in analyzing the effect of the number of rotor bars.

동파방지열선 화재 흔적분석과 발화원인 연구 (A Study for the Fire Analysis and Igniting Cause of Freezing Protection Heating Cables)

  • 이정일;하각천
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.15-20
    • /
    • 2018
  • There have been a number of major fatal fire accidents in Korea recently. The number of fires in 2017 were 44,178, which is not only increasing number of fires but also increasing in casualties. Particularly, the fire at Jecheon Sports Center, which suffered many casualties, is expected to have a huge impact. The cause of the fire has not been determined yet, but heat waves on the ceiling have also been pointed out. As such, the copper heating waves, which are used as a preventive measure against damage of pipes due to freezing of pipes, etc., always have a fire hazard. To determine the possibility of a flame-resistant heated fire, a positive electric cable product was used to artificially ignite and analyze the results. In case of a short circuit, the external covering of the positive electric cable is damaged, but not short circuit unless the heating material surrounding the wire is damaged. Due to the characteristics of heating cable for preventing copper waves, the chances of insulation becoming more severe due to moisture and temperature changes are higher than normal wires. If the internal heating system is carbonized by insulating deterioration without damage to the outer coating, it is likely to cause trekking, to form a winding loop in the heating materials, and to cause short circuit in the heated materials. For the positive temperature line, if the middle is shorted, the current continues to flow to the short circuit unless the breaker disconnects. Consequently, a heated fire that does not cut off the power immediately may leave multiple marks or cuts.

Multi-Secondary Transformer: A Modeling Technique for Simulation - II

  • Patel, A.;Singh, N.P.;Gupta, L.N.;Raval, B.;Oza, K.;Thakar, A.;Parmar, D.;Dhola, H.;Dave, R.;Gupta, V.;Gajjar, S.;Patel, P.J.;Baruah, U.K.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.78-82
    • /
    • 2014
  • Power Transformers with more than one secondary winding are not uncommon in industrial applications. But new classes of applications where very large number of independent secondaries are used are becoming popular in controlled converters for medium and high voltage applications. Cascade H-bridge medium voltage drives and Pulse Step Modulation (PSM) based high voltage power supplies are such applications. Regulated high voltage power supplies (Fig. 1) with 35-100 kV, 5-10 MW output range with very fast dynamics (${\mu}S$ order) uses such transformers. Such power supplies are widely used in fusion research. Here series connection of isolated voltage sources with conventional switching semiconductor devices is achieved by large number of separate transformers or by single unit of multi-secondary transformer. Naturally, a transformer having numbers of secondary windings (~40) on single core is the preferred solution due to space and cost considerations. For design and simulation analysis of such a power supply, the model of a multi-secondary transformer poses special problem to any circuit analysis software as many simulation softwares provide transformer models with limited number (3-6) of secondary windings. Multi-Secondary transformer models with 3 different schemes are available. A comparison of test results from a practical Multi-secondary transformer with a simulation model using magnetic component is found to describe the behavior closer to observed test results. Earlier models assumed magnetising inductance in a linear loss less core model although in actual it is saturable core made-up of CRGO steel laminations. This article discusses a more detailed representation of flux coupled magnetic model with saturable core properties to simulate actual transformers very close to its observed parameters in test and actual usage.