• 제목/요약/키워드: winding number

검색결과 194건 처리시간 0.027초

SRM의 고효율화를 위한 적정권선 설계의 연구 (Design standard of winding number of stator pole for high efficiency Switched Reluctance Motor)

  • 정태욱;추영배;공관식;안영주;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.85-87
    • /
    • 1993
  • SRM drive system is suitable for high performance drive over a wide speed range because of its outstanding instantaneous torque characteristics, controllability and simple drive structure. The realization of high efficiency SRM system is archived by design of optimal magnetic structure, and by development of switching drive circuit. So, this study describes the design standard of the winding number of stator pole for optimal magnetic structure.

  • PDF

수력발전기 고정자 권선의 운전중 부분방전 특성 (Properties of On-Line Partial Discharge in Hydrogenerator Stator Windings)

  • 김병한;김희동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.172-177
    • /
    • 2006
  • During normal machine operation, partial discharge(PD) tests were performed with partial discharge analyzer(PDA) in two hydrogenerators. Six cable couplers were installed in circuit ring bus and endwinding of three phases. PDA showed that the normalized quantity number(NQN) and the partial discharge magnitude$(Q_m)$ were very low in hydrogenerator #1 and #2, respectively. The trend analyses of NQN and $Q_m$ value are available for monitoring of the insulation condition in hydrogenerator stator windings. The insulation condition of stator winding can be assessed. Discharge at conductor surface was discovered in B phase(C2 coupler) of hydrogenerator #1. Internal discharges were generated in A and C phases(C2 coupler) of hydrogenerator #1 and in A, Band C phases(C1 and C2 couplers) of hydrogenerator #2. Slot discharges occurred in A, Band C phases(C1 coupler) of hydrogenerator #1. The stator windings of two hydrogenerators were in good condition.

발전기 운전중 회전자 진단에 관한 연구 (On-Line Diagnosis Method for Generator Rotor Windings)

  • 이영준;공태식;김희동;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1846-1849
    • /
    • 2002
  • A shorted-turn test was performed at the Sininchon combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line diagnosis system. The flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change of the flux. This pattern of flux variation is a signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.

  • PDF

발전기 운전중 회전자 계자권선의 단락 진단기법에 관한 연구 (Shorted-Turn Detction Techniques for Generator Rotor)

  • 이영준;김희동;빅종정;주영호;조지원;이병하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1721-1724
    • /
    • 1998
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas. turbine generator #4. The test was conducted using a permanent flux probe and digital oscilloscope. The flux probe installed in the generator air gap, senses the field winding slot leakage flux and produces a voltage proportional to the rate of change of the flux. This pattern of flux variation is a signature unique to each field winding. We have also applied a waveform analysis technique that can identify the pole location, slot number, and number of shorted-Turns with each slot.

  • PDF

코어 변화에 대한 자계 특성 (Magnetic Field Properties About Core Change)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제25권2호
    • /
    • pp.159-164
    • /
    • 2012
  • In this paper, it tried to develop the core sensor for detection of micro magnetic field in electric wires. The sensor is non contact type and is consisted of ferrite core for low price. To investigate their properties for variations of current, it changed the number of winding and the length of sample core, it examined, to check the live wire situation in built-in wires, electrical characteristics due to difference between electric wires and core sensor. As the results, it verified live wire situation at the number of winding(5,000) and within length of 6[cm]. Also, it obtained magnetic field magnitude decreased inverse proportion ratio to a square about difference between electric wires and core sensor.

페라이트 변화에 따른 무전극 형광램프의 휘도 특성 변화 (Brightness special Quality change of wireless electrodeless fluorescent lamp by ferrite change)

  • 백광현;양종경;이종찬;최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.171-176
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relative propertye of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. Coill turn was changed from 13th to 15th turn to recognize brightness change of lamp by winding number. Optical equipment that used in an experiment was used to measure brightness (LS-100). When an electrodeless fluorescent lamp was made using and T company's PE22, was it showed the highest brightness. As number of winding is increased the brightness increased, and starting characteristic became good.

  • PDF

발전기 회전자 권선의 건전성 평가 (Assessment of Insulation Condition for Generator Rotor Windings)

  • 이영준;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.59-60
    • /
    • 2006
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line shorted-turn diagnosis system. The permanent flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.

  • PDF

생사검사방법 및 격부법에 관한 연구 재조검사의 비교연구 (1) (Studies on Raw Silk Test and Classification Comparative Studies on Winding Test and Classification between Korean and Japanese Method)

  • 김한수
    • 한국잠사곤충학회지
    • /
    • 11호
    • /
    • pp.81-86
    • /
    • 1970
  • 본 연구는 재조검사의 비교연구에 관한 것으로 우리나라의 실험성적 (1668.9∼ll)과 개정법 실시 이전에 조사된 일본의 실험성적(1968.6)을 비교 검토한 결과 다음과 같은 결론을 얻었다. (1) 우리나라 생사는(21D.춘) 현행법에서 평균절단수 5.91회인 것이 개정법에서는 8.6회로 평균 2.7회가 증가되었다. 일본생사는 (21D.) 현행법에서 평균절단수 3.6회 인 것이 개정법에서는 4.7회로 평균 1.1회가 증가되었다. (Table 1,2 참조) (2) 절단회수별 하구수분포는 우리나라의 경우 현행법에서 절반수가 3,4 및 5회의 것이 가장 많았고(48%) 개정법에서는 5,6 및 7회의 것이 많았으며 (36%) 평균절단수증가 만큼의 (2.7회) 차와 같은 경향의 분포를 나타내었다. 일본의 경우에도 현행법에 있어서는 절단수 1.2 및 3회의 것이 가장 많았고 (55%) 재정법에서는 2.3및 4회의 것이 많았으며 (50%) 평균절단수 증가만큼의 (1.1과) 차와 같은 경향의 분포를 나타내었다. (Table 1.2참조) (3) 겉타래의 예비재조시간의 절단수 분포를 보면 우리나라와 일본이 다같이 평균절단수를 중심으로 분포되어 있으나 무절단 비율은 우리나라의 7%에 비해 일본은 43%로 월등히 많았다. (Table 3 참조) (4)표 2.3및 4의 성적을 현행 및 개정격부법에 준해 비교검토하면 우리나라 생사는 현행격부법에 준한 경우 1계급(6회) 이 68%, 2계급(10회)이 22%, 그러고 3계급(4회)이 13% 밖에 안되며 2계급(10회)이 56% 3계급(18회)이 29%로 약 55%가 1계급에서 2계급으로 하락하였으며 2계급에서 3제급으로 약 20%가 하락하는 경향을 보였다. 이에 대해 일본 생사는 현행격부법에 준한 경우 1계급(6회)이 85%, 2계급(10회)이 10% 그리고 3계급(13회)이 5%이었으며 개정격부법에서는 1계급이 60% 2계급이 33% 그리고 3계급이 7%로 우리나라 생사에 비해 소수의 것만이 1계급에서 2계급으로 하락하였을 뿐 출현도에 별차가 없었다. (Table 6 참조) (5) 재정격부법중 재조의 계급구분을 1계급의 것을 6회에서 4회로 특히 강화 하였는데 이것은 오직 일본 생사의 평균제조 절단수 만을 (4회 ;1969) 참작한 일본생사 위주로 작성된 것이라 생각한다. 그것은 생사생산국간의 재조검사 성적을 보아도 한국은 일본의 다음이며 그외 품질의 우수함도 널리 알려져 있기 때문이다. (6) 이상의 여러가지를 비교 검토할 때 현행법에서 평균절단수 5회 정도인 우리나라 생사는 재정법을 적용하는 경우 8∼9회를 쉽게 예상할 수 있는 것이며 생사수요자들이 중요시하는 재조성적으로 인한 격 하락의 수가 증가하리라 생각한다.

  • PDF

Studies on Reduction of Yarn Hairiness by Nozzles in Ring Spinning and Winding by Airflow Simulation

  • Rengasamy R. S.;Patnaik Asis;Punekar Hemant
    • Fibers and Polymers
    • /
    • 제7권3호
    • /
    • pp.317-322
    • /
    • 2006
  • Reduction of yam hairiness by nozzles in ring spinning and winding is a new approach. Simulation of the airflow pattern inside the nozzles provides useful information about actual mechanism of hairiness reduction. The swirling air current inside the nozzles is capable of wrapping the protruding hairs around the yam body, thereby reducing yam hairiness. Since production rate of winding is very high and the process itself increases yarn hairiness any method to reduce the hairiness of yarns at this stage is a novel approach. A CFD (computational fluid dynamics) model has been developed to simulate the airflow pattern inside the nozzles using Fluent 6.1 software. In this study, both S- and Z-type nozzles having an axial angle of 500 and diameter of 2.2 mm were used for simulation studies. To create a swirling effect, four air holes of 0.4 mm diameter are made tangential to the inner walls of the nozzles. S- and Z-twisted yams of 30 tex were spun with and without nozzles and were tested for hairiness, tensile and evenness properties. The total number of hairs equal to or exceeding 3 mm (i.e. the S3 values) for yam spun with nozzle is nearly 49-51 % less than that of ring yams in case of nozzle-ring spinning, and 15 % less in case of nozzle-winding, while both the yarn types show little difference in evenness and tensile properties. Upward airflow gives best results in terms of hairiness reduction for nozzle-ring and nozzle wound yams compared to ring yarns. Yarn passing through the centre of the nozzle shows maximum reduction in S3 values.

2차 권선을 직.병렬연결한 자속구속형 전류제한기의 퀜치특성 (Quench Characteristics of a Flux-lock type SFCL with Secondary Windings Connected in Serial and Parallel)

  • 박형민;조용선;최효상;오금곤;한태희;임성훈;황종선
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.432-434
    • /
    • 2006
  • We investigated the quench characteristics of a flux-lock type superconducting fault current limiter (SFCL) according to the number of the superconducting elements at the subtractive polarity winding of a transformer. The flux-lock type SFCL consists of the transformer with a primary winding and two secondary windings connected in parallel, and the superconducting element was connected with secondary winding in series, respectively. The applied voltage at that tin was 200V. when two superconducting elements of the secondary winding was connected in parallel, the peak lie current increased up to 99A, while that flowing in a superconducting element in conventional flux-lock type SFCL showed 50A under the same conditions, the impedance of secondary winding under the same situation showed the opposite behavior. This enabled the parallel structure to be easy to increase the capacity of power system, in the meantime, The quench between two superconducting elements in the SFCL with two secondary windings connected in parallel was achieved simultaneously. While the quench-starting point was slightly different in the SFCL with two superconducting elements connected in series. We found that the parallel connection between the secondary windings increased the power capacity and let quench characteristics improve through their mutual linkage.

  • PDF