• 제목/요약/키워드: winding number

검색결과 194건 처리시간 0.025초

2중 인버터 시스템을 갖는 해상용 풍력발전기의 3상 평형성에 관한 연구 (A Study on 3-Phase Balance of Offshore Wind Generator with Dual Inverter System)

  • 서장호
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.23-30
    • /
    • 2013
  • This paper shows the method of winding connection and the balance of three phase of dual inverter systems used for offshore wind power generator. In order to satisfy low cost manufacturing of large scaled wind generator, the number of slot per pole per phase should be reduced. For this reason, in this research, the number is selected as '1' which is the minimum number that stator can have. Based on the prototype machine, three types of machine for the analysis are selected, and various performances especially in terms of electrically balanced condition are also investigated. Moreover, in this paper, new inductance modeling of dual 3-phase considering cross-coupling between two inverter systems is proposed. The several inductances such as mutual-, synchronous inductances are studied. By using FEA, based on calculated the flux linkage of d and q-axis, the validity of the proposed inductance modeling is confirmed.

고압권선에서 발생하는 부분방전에 의한 초음파 신호 검출 (Detection of Ultrasonic Signals by PD at the High Voltage Winding)

  • 권동진;곽희로;정상진;김한상;송일근;김경화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.456-458
    • /
    • 1995
  • This paper describes a diagnosis of power transformers by on-line detection of ultrasonic signals. Partial discharge in power transformer generates ultrasonic signals. The trend of the ultrasonic signal number can be measured when partial discharge is generated in HV Winding. The trend of the ultrasonic signal number could easily be distinguished by taking moving average. The insulation failure due to partial discharge in transformers can be predicted based in the trend analysis of the number of ultrasonic signals caused by partial discharge.

  • PDF

퍼지이론을 적용한 최적 인덕터 설계 파라미터 선정에 관한 연구 (A Study on the Selection of Parameter for the Optimal Inductor Design using Fuzzy Theory)

  • 윤창선;배동관;김광헌;이재신;김병철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.58-61
    • /
    • 1999
  • This paper describes the program of optimally choosing parameter in designing inductor, which applied by fuzzy theory, and verifies the reliability of program to use in design of power supply of electronic machine and information communication. It is available to find optimal value of complex and various parameter, such as core, winding, winding number, and air-gap, etc., needed on designing inductor. We expects to minimize time and cost of inductor design.

  • PDF

복합재료 압려용기 Type-4 설계 프로그램 개발 (Development of Design Program for Composite Pressure Vessel Type-4)

  • 이호용;조치룡
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 추계학술발표대회 논문집
    • /
    • pp.224-227
    • /
    • 2004
  • A computer program for composite pressure vtlssel design is developed. In-puts are : material-property(young's modulus, shear modulus, tensile strength, poisson's ratio, density), operating pressure, burst pressure, liner thickness, boss diameter, boss weight and number of helical angles. Out-puts are; thickness of each layer, weight of the vessel, dimension of the vessel, inner volume, dome-shape and helical winding angle. Also filament winding angles can be selected various kinds of utilizing virtual boss diameter.

  • PDF

유한요소법을 이용한 공심 원통현자석의 인덕탄스 계산에 관한 연구 (Iductance Computations of Air-Core Solenoid Magnets by FEM)

  • Kown, Young-Ahn
    • 대한전기학회논문지
    • /
    • 제39권3호
    • /
    • pp.247-253
    • /
    • 1990
  • The inductances of air-core solenoid magnets with circular cross sections depend on the geometric structure and winding number. For the calculation of the inductance of these magnets, Grover's table is normally used. This study presents a method to calculate the inductance using finite element method. The result of the computation agrees well with those found in the literature. Inductances of solenoid magnets with nonuniform winding distribution of complicated shapes can also be computed using this method.

  • PDF

Research on a New 12-Pulse Step-Up and Step-Down Aviation Auto-Transformer Rectifier

  • Jiang, Fan;Ge, Hong-juan;Dong, Xiao-xu;Zhang, Lu
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.266-276
    • /
    • 2018
  • This paper presents a new step-up and step-down multi-pulse auto-transformer rectifier unit (ATRU) topology. This structure can achieve a wide range of output voltages, which solves the problem of auto-transformer output voltage being difficult to regulate. Adding middle taps to the primary winding and reasonably setting the number of auto-transformer windings, constituted two groups of three-phase output voltages with a $30^{\circ}$ phase difference. Multi-pulse output DC voltage is obtained after a three-phase output voltage across two rectifier bridges and inter-phase reactor. Thus, the output DC voltage is related to the number and configuration of the auto-transformer winding. In this paper, the relationship between the voltage ratio of the auto-transformer and the ratio of winding, input current and auto-transformer kilovoltampere rating are deduced and validated by simulations. On this basis, the output voltage range is optimized. An experiment on two different voltage ratio principle prototypes was carried out to verify the correctness of the analysis design.

자속구속형 초전도전류제한기의 권선비 변화에 따른 전류제한 및 전압강하 보상 특성 (Current Limiting and Voltage Sag Suppressing Characteristics of Flux-lock Type SFCL According to Variations of Turn Number's Ratio)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제24권5호
    • /
    • pp.410-415
    • /
    • 2011
  • In this paper, we investigated the fault current limiting and the load voltage sag suppressing characteristics of the flux-lock type SFCL, designed with the additive polarity winding, according to the variations of turn number's ratio and the comparative analysis between the resistive type and the flux-lock type SFCLs were performed as well. From the analysis for the short-circuit tests, the flux-lock type SFCL designed with the larger turn number's ratio was shown to perform more effective fault current limiting and load voltage sag suppressing operations compared to the flux-lock type SFCL designed with the lower turn number's ratio through the fast quench occurrence of the high-$T_C$ superconducting (HTSC) element comprising the flux-lock type SFCL. In addition, the recovery time of the flux-lock type SFCL after the fault removed could be confirmed to be shorter in case of the flux-lock type SFCL designed with the lower turn number ratio.

단상유도기의 권선법 및 슬롯 구조에 따른 특성 해석 연구 (A Study on the Characteristic Analysis of Winding Method and Slot Structure for Single Phase Induction Motor)

  • 황요한;김기찬;원성홍;정대성;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.203-205
    • /
    • 2006
  • This paper presents a study on the winding method and structure of core of single phase induction motor in order to design the high efficiency motor. In case of single phase induction motor, winding fill factor and the number of turns in each slot are not uniform in general. Moreover, these can be the critical parameters for high efficiency design in case the size of motor should be restricted within certain volume. Therefore, we should analyze the effects of these parameters related to efficiency parameter. The characteristic analysis was performed by using FEM.

  • PDF

터빈 발전기 회전자 권선의 층간단락 분석 (Analysis of Shorted Turns in Turbine Generator Rotor Windings)

  • 김희동;김병래;최형주
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1555-1559
    • /
    • 2011
  • Turbine generator(13.8 kV, 137.5 MW) has high bearing vibration at rotation speed. Shorted turns in generator rotor windings have strong correlation with increased field current which is thus related to increase in bearing vibration. The recurrent surge oscillograph (RSO) test is performed on the rotor winding in turbine generator to detect shorted turns. The result of the RSO test indicates that shorted turns of rotor winding are generated in two locations. The RSO test was capable of identifying the presence, number, and location of shorted turns in generator rotor windings.

가스터빈 발전기 고정자 권선의 절연상태 평가 (Assessment of Insulation Condition in Gas Turbine Generator Stator Windings)

  • 김희동;양규현;주영호
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1423-1428
    • /
    • 2010
  • The results of off-line and on-line diagnostic tests performed on the stator winding of an air-cooled gas turbine(G/T) generator are reported in this paper. Off-line diagnostic tests included measurements of the ac current, dissipation factor(tan${\delta}$), and partial discharge(PD). Six epoxy-mica capacitors were installed in the three phases of G/T generator for performing on-line diagnostic testing with the turbine generator analyzer(TGA). The TGA showed that the normalized quantity number(NQN) and the PD magnitude($Q_m$) were high in phase A of the stator winding. Internal discharges were generated in phases B and C, and slot discharge occurred in phase A. According to the trend analyses of the NQN and $Q_m$ values available for insulation condition assessment for G/T generator stator windings, it was concluded that phases B and C were in good condition, whereas phase A has been significantly deteriorated.