Application of AE Technique for On-line monitoring of Quencl in superconducting coil at Cryogenic Environment (음향방출을 이용한 극저온 환경하에서의 초전도 계자코일의 ?칭탐지에 관한 연구)

  • 이준현;이민래;권영길;류강식
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.34-38
    • /
    • 1999
  • An acoustic emission(AE) technique has been used to monitor and diagnose quenching phenomenon in racetrack shaped superconducting magnets at cryogenic environment of 4.2K. The ultimate goal is to ensure the safety and reliability of large superconducting magnet systems by being able to identity and locate the sources of quench in superconducting magnets. The characteristics of AE parameters have been analyzed by correlating with quench number, winding tension of superconducting coil and charge rate by transport current. It was found in this study stat there was good correlation between quench current and AE parameters. The source location of quenching in superconducting magnet was also discussed on the correlation between magnet voltage and AE energy.

  • PDF

Design and Performance Test of the Force Motor for Direct Drive-type Pneumatic Servo Valve (직동식 공압서보밸브의 Force Motor 설계 및 성능시험)

  • 이원희;김동수;박상운
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.836-839
    • /
    • 2003
  • A pneumatic servo valve which is widely applied in industrial field. And It is consist of force motor, spool & sleeve and servo controller. In this study. we developed the force motor which is consume to low power for a pneumatic servo valve. We could reduce the number of turn of the solenoid by using ferromagnetic permanent magnet and took different direction of each other using one coil instead of two coil. we modeled a system consisting of various electro-mechanical subsystems. The appropriateness of the model was verified by simulation. The simulation model resolved the motion of spool, the winding current and the magnetic force. Also, we calculated the displacement and velocity of the spool, flux contour line, b vector. flux density. flux linkage, back EMF etc.

  • PDF

A Study on the Improvement of Attraction Force of Solenoid Operated Valves (솔레노이드 밸브의 흡인력 개선을 위한 연구)

  • Lim, Byung-Ju;Park, Chang-Dae;Lee, Tae-Gu;Yun, So-Nam;Chung, Kyung-Yul
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2012.06a
    • /
    • pp.121-122
    • /
    • 2012
  • In this research, we studied on improvement of the attraction force of solenoid operated valve for normal operation in harsh environment like vessel. Attraction force of the solenoid valves is effected by the B-H characteristics of magnetic material and the size of coil. In order to specify impact of the affection, we performed the B-H characteristics test and attraction force. Test results show that magnetic flux densities of the materials are difference each other more than 2 times in same magnetic intensity, and attraction force of the solenoid valve is 1.7 times difference as changes of resistance and the number of coil winding of solenoid.

  • PDF

Flowrate characteristics and application of screw pump (스크류펌프의 유량특성과 적용)

  • Lim, Jong-Soon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.614-625
    • /
    • 2004
  • The main purpose of this study is to get flowrate coefficient 'q' and to study characteristics of flowrate of screw pump. This study is based on Muskin's formula and depends on the computer simulation. The results of study are as follows. 1. Flowrate coefficient will reduce according to increase of inclination. The larger the pitch ratio is and the smaller the diameter ratio is, the more coefficient reduces. 2. As a rule, the coefficient increases according to reduction of the diameter ratio, but the coefficient tends to reduce when the ratio is less than 0.45. So, in actual application, it is recommended that the ratio should be above 0.45. 3. If the pitch ratio increases, the coefficient increases in case of small inclination and decreases in case of large inclination. 4. The coefficient increases according to number of windings. Especially, singles winding is not used in actual application because it has too small coefficient. 5. The coefficient decreases when the influent water level falls. Flowrate is almost zero when the water level is below $40\%$ of Filling Points.

  • PDF

Experimental Operation Analysis of Unified Power Flow Controller with Cascaded H-Bridge Modules (다계 H-브리지 모듈로 구성된 UPFC(Unified Power Flow Compensator)의 실험적 동작분석)

  • Baek, Seung-Taek;Bae, Byung-Yeol;han, Byung-Moon;Baek, Doo-Hyun;Jang, Byung-Hoon;Yoon, Jong-Soo;Kim, Soo-Yeol
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.389-391
    • /
    • 2005
  • This paper describes experimental analysis of UPFC, which is composed of cascaded H-bridge modules and single-phase multi-winding transformers for isolation. The operational characteristic was analyzed through experimental works with a scaled model, and simulation results with PSCAD/EMTDC. The UPFC proposed In this paper can be directly connected to the transmission line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual UPFC system applicable for the transmission system.

  • PDF

Design of 65kW Class SRM for HEV (65kW급 HEV용 SRM의 설계)

  • Kim, Tae-Hyoung;Ahn, Jin-Woo;An, Young-Joo;Moon, Jae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.562-564
    • /
    • 2005
  • This paper presents the reasonable design parameters of a SRM for hybrid electric vehicle driving. For the design of SRM, the initial model is designed using the equivalent magnetic circuit method. In order to optimize the SRM for HEV. The initial model is redesigned by FEM with the variation of the stock length and turns of winding. This paper shows that a flat-topped current of a phase can be made from a change of the stack length and the number of turns for high efficiency, high average torque and a lower torque ripple. The change of current falling time as a variation of turn-off angle was shown by FEA. The iron loss and copper loss were described. The torque of the redesigned motor is suitable for low and high speed ranges to drive a HEV that was verified by the speed-torque curve.

  • PDF

Analysis of Cogging Torque and Characteristics in Brushless DC Motor (브러시레스 전동기의 코깅토크 해석 및 특성해석)

  • Lee, Ji-Young;Lim, Yang-Soo;Hong, Jung-Pyo;Kim, Gyu-Tak;Sin, Sang-Yun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.629-631
    • /
    • 2000
  • This paper deals with the design of a inner rotor type Brushless DC (BLDC) motor for Electric Power Steering to reduce the cogging torque. The effect of the design parameters on the characteristic and cogging torque is analyzed by Finite Element Method (FEM). The considered design parameters are as follows : the number of pole and slot. dead-zone and skew angle. and teeth shape. The winding resistance of each motor is calculated and the characteristic curve is derived from considering reactance drop voltage for original model.

  • PDF

Experimental Analysis Result of Unified Power Quality Controller with Cascaded H-Bridges using Scaled Prototype (H-브리지로 구성된 UPQC(Unified Power Quality Conditioner)의 축소모형 실험결과 분석)

  • Cho, Yun-Ho;Han, Syung-Moon;Kim, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.93-96
    • /
    • 2005
  • This paper describes experimental analysis of UPQC, which is composed of cascaded H-bridges and single-phase multi-winding transformers. The operational characteristic was analyzed through experimental works with a scaled model, and simulations with PSCAD/EMTDC. The UPQC proposed in this paper can be directly connected to the distribution line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual UPQC system applicable for the actual distribution system.

  • PDF

Operation Analysis of UPQC(Unified Power Quality Conditioner) based on H-bridge Modules (H-브리지 모듈로 구성된 UPQC(Unified Power Quality Conditioner)의 동작 분석)

  • Lee Bum-Kyoo;Bae Byung-Yeol;Baek Seung-Tak;Han Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • This paper proposes a novel UPQC(unified power quality conditioner) based on H-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with PSCAD/EMTDC, assuming that the UPQC is connected with the 22.9kV distribution line. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of H-bridge modules and can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems.

Experimental Operation Analysis of Unified Power Flow Controller with Cascaded H-Bridge Modules (다계 H-브리지 모듈로 구성된 UPFC(Unified Power flow Compensator)의 실험적 동작분석)

  • Baek Seung-Tak;Han Byung-Moon;Choo Jin-Boo;Chang Byung-Hoon;Yoon Jong-Su
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.9
    • /
    • pp.422-430
    • /
    • 2005
  • This paper describes experimental analysis of UPFC, which is composed of cascaded H-bridge modules and single-phase multi-winding transformers for isolation. The operational characteristic was analyzed through experimental works with a scaled model, and simulation results with PSCAD/EMTDC. The UPFC proposed in this paper can be directly connected to the transmission line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual WFC system applicable for the transmission system.