• Title/Summary/Keyword: wind-speed change

Search Result 370, Processing Time 0.045 seconds

Study on a Limit MPPT Controller for the Modelling of a Wind Power Generator (풍력발전기 모델링 및 리미트 MPPT제어기에 관한 연구)

  • Kang, Ju-Sung;Koh, Kang-Hoon;Choi, Kwang-Ju;Park, Jae-Yoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.53-59
    • /
    • 2007
  • Now, the study is activity that the energy market depending on a fossil fuel tend to change different way. In middle of the study compositive use of renewable energy(fuel cell and wind power, solar cell, etc.) is dispersion power system which concern is increasing. But in the case of generation of electric wind power system is changeable to be turbulence and wind and win speed are changeable in several seconds, so making the best of wind energy the MPPT that role in this case is important. In this paper suggest a MPPT which is making a use of information of wind speed and turning speed, windmill, electric power but it is simpler than former way. We could verify that a proposed controller working at the highest point of electric power when wind speed is regular speed and changable speed through the simulation.

A Study on the Fault Current of Distribution System according to Connection of Wind Turbine Generation Grid-Connected Transformer (풍력발전 계통연계 변압기의 결선에 따른 배전계통의 고장전류에 관한 연구)

  • An, Hae-Joon;Ro, Kyoung-Soo;Kim, Hyun-Goo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.369-371
    • /
    • 2007
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

The Relationship between Wind Power Generation Grid-connected Transformer Winding Connection and Fault Current in MATLAB & SIMULINK (MATLAB & SIMULINK에서 풍력발전 계통연계 변압기결선과 고장전류와의 관계)

  • An, Hae-Joon;Kim, Hyun-Goo;Jang, Gil-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.307-309
    • /
    • 2008
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

Experimental Study to measure Aerodynamical Wind Effects of KTX for Determining the Distance Between Track Centers (선로간격 설정시 KTX 열차풍 영향 측정에 관한 실험 연구)

  • Nam, Seong-Won;Kwon, Hyeok-Bin
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.518-521
    • /
    • 2008
  • When constructing a high-speed railroad, the reduction of the distance between track centers and the width of track bed will save the construction cost. However the shortening the distance between track centers may cause the stability problems due to higher wind pressure. Therefore the extensive technical review and aerodynamical study should be performed to determine the adequate distance between track centers. In this study, the impact that the increase in wind pressure due to the change of aerodynamic phenomena with the change of the distance between track centers may have on two trains passing by each other was predicted, and the stability of train operation was analyzed in order to review the distance between track centers suitable to Honam HSR trains. And we estimated the aerodynamical effects by the results of the real train experiments by using KTX.

  • PDF

Effect of Wake on the Energy Production of the Downstream Wind Turbine (후류가 하류 풍력발전기의 발전량에 미치는 영향)

  • Hong, Young-Jin;Yoo, Hoseon
    • Plant Journal
    • /
    • v.12 no.3
    • /
    • pp.32-38
    • /
    • 2016
  • In this study, the effect of wake on the energy production of a downstream wind turbine was analyzed on the base of operation practices of wind farm in the coastal complex terrain which has 2 row array of wind turbines. And changes in the variation of wind speed and turbulence intensity was analyzed. In case wind turbines are spaced 4-rotor diameter-apart in the prevailing wind direction, reduction in energy production was confirmed due to the decrease of wind speed and the increase of turbulence intensity by wake. Especially a radical change of wind direction caused wind turbine a sudden stop and energy production significantly reduced. It is considered improvement of yaw brake can prevent the sudden stop and increase energy production.

  • PDF

Estimation of the Topographic Factor of Wind Speed Using GIS Information (GIS 정보를 이용한 풍속지형계수 산정)

  • Seong, Min-Ho;Choi, Se-Hyu
    • Spatial Information Research
    • /
    • v.19 no.5
    • /
    • pp.47-52
    • /
    • 2011
  • Recently damage scale by local winds and typhoon has dramatically increased. Korea has the terrain over 70% of the land and the planning of the wind load is necessary to estimate reflecting appropriately the change of the wind-speed according to the characteristic of the terrain and in the Korean Building Code(2009), this is stated and it reflects to the design process. However, in order to estimate the topographic factor of the wind speed considering the topographic characteristics in the structure design actually, it has many difficult points including the local topographic survey, etc. In this paper, the Digital Elevation Model(DEM) is created using TIN interpolation method in the form of the digital map and then the interface was designed and implemented which can automatically estimate the topographic factor of wind speed by using ESRI(R)ArcObjectTM and the Visual Basic programing language. By applying it to the terrain which positioned in the downtown area, the practicality of the topographic factor of wind speed estimation interface was checked.

Parametric Study of the Effects of Train Wind on Turnover Safety (차량 전복 안전성에 끼치는 열차 풍압의 파라메타 연구)

  • Nam, Seong-Won
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.961-966
    • /
    • 2009
  • When constructing a high-speed railroad, the reduction of the distance between track centers and the width of track bed will save the construction cost. However the shortening the distance between track centers may cause the stability problems due to higher wind pressure. Therefore the extensive technical review and aerodynamical study should be performed to determine the adequate distance between track centers. In this study, the impact that the increase in wind pressure due to the change of aerodynamic phenomena with the change of the distance between track centers may have on two trains passing by each other was predicted, and the stability of train operation was analyzed in order to review the distance between track centers suitable to Honam HSR trains. We conducted the parametric study of the effects of train wind on the running stability.

A Study on Driving Characteristics of Power Compensation Discontinuity Energy Occurrence System (탄성에너지를 이용한 전력보상 불연속에너지발생시스템의 운전특성에 관한 연구)

  • Park, Se-Jun;Lim, Jung-Yeol;Yoon, Suk-Am;Gang, Byeong-Bog;Cha, In-Su
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.622-626
    • /
    • 2002
  • Combined generation system of photovoltaic and wind power is required backup system that such as a storage battery to supply energy, when not enough photovoltaic and wind power source for power supply equally and continually, because the energy source is changeable and stable through change of weather as irradiation, temperature, wind speed, wind speed, wind direction, seasons, etc..

  • PDF

A Study on Driving Characteristics of Power Conpensation Device using elasticit (탄성에너지를 이용한 전력보상장치의 운전특성에 관한 연구)

  • Park, Se-Jun;Kang, Byung-Bog;Lim, Jung-Yeol;Yoon, Jeong-Phil;Cho, Kyung-Jae;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.235-239
    • /
    • 2002
  • Combined generation system of photovoltaic and wind power is required backup system that such as a storage battery to supply energy, when not enough photovoltaic and wind power source for power supply equally and continually, because the energy source is changeable and stable through change of weather as irradiation, temperature, wind speed, wind speed, wind direction, seasons, etc..

  • PDF

Evaluation on Effect of Wind Power Generation System According to Transformer Winding Connection at Matlab&Simulink (MATLAB&SIMULINK에서 변압기 결선에 따른 풍력발전 시스템의 영향 평가)

  • An, Hae-Joon;Ro, Kyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.772-773
    • /
    • 2007
  • This study suggests a modeling of grid-connected wind power generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, rotor speed, terminal voltage, system voltage, and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF