• Title/Summary/Keyword: wind-induced forces

Search Result 127, Processing Time 0.023 seconds

Investigation of the Vortex Shedding with the Shear Building (전단건물을 이용한 와류발산현상 파악)

  • Lee, Sang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1785-1790
    • /
    • 2010
  • To study the vortex induced vibrations the wind tunnel and the two story shear building were designed and built. The wind tunnel was designed to generate the wind speed up to 24 m/s, and the building was designed to have the two lowest natural frequencies within the range of the vortex frequencies generated by the wind tunnel. The resonance behaviors by the locking-on phenomena were observed during the wind tunnel tests of the shear building with the cylinder attached. From the locking-on phenomena observed it is found that the effects of the amplitudes and the frequencies of the cylinders should be considered on the forces generated by the vortex shedding.

Motion Analysis of A Wind-Wave Energy TLP Platform Considering Second-order Wave Forces

  • Hongbhin Kim;Eun-hong Min;Sanghwan Heo;WeonCheol Koo
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.390-402
    • /
    • 2022
  • Offshore wind energy has become a major energy source, and various studies are underway to increase the economic feasibility of floating offshore wind turbines (FOWT). In this study, the characteristics of wave-induced motion of a combined wind-wave energy platform were analyzed to reduce the variability of energy extraction. A user subroutine was developed, and numerical analysis was performed in connection with the ANSYS-AQWA hydrodynamic program in the time domain. A platform combining the TLP-type FOWT and the Wavestar-type wave energy converter (WEC) was proposed. Each motion response of the platform on the second-order wave load, the effect of WEC attachment and Power take-off (PTO) force were analyzed. The mooring line tension according to the installation location was also analyzed. The vertical motion of a single FOWT was increased approximately three times due to the second-order sum-frequency wave load. The PTO force of the WEC played as a vertical motion damper for the combined platform. The tension of the mooring lines in front of the incident wave direction was dominantly affected by the pitch of the platform, and the mooring lines located at the side of the platform were mainly affected by the heave of the platform.

Influence of a community of buildings on tornadic wind fields

  • Li, Zhi;Honerkamp, Ryan;Yan, Guirong;Feng, Ruoqiang
    • Wind and Structures
    • /
    • v.30 no.2
    • /
    • pp.165-180
    • /
    • 2020
  • To determine tornadic wind loads, the wind pressure, forces and moments induced by tornadoes on civil structures have been studied. However, in most previous studies, only the individual building of interest was included in the wind field, which may be suitable to simulate the case where a tornado strikes rural areas. The statistical data has indicated that tornadoes induce more significant fatalities and property loss when they attack densely populated areas. To simulate this case, all buildings in the community of interest should be included in the wind field. However, this has been rarely studied. To bridge this research gap, this study will systematically investigate the influence of a community of buildings on tornadic wind fields by modeling all buildings in the community into the wind field (designated as "the Community case under tornadic winds"). For comparison, the case in which only a single building is included in the tornadic wind field (designated as "the Single-building case under tornadic winds") and the case where a community of buildings are included in the equivalent straight-line wind field (designated as "the Community case under straight-line winds") are also simulated. The results demonstrate that the presence of a number of buildings completely destroys the pattern of regular circular strips in the distribution of tangential velocity and pressure on horizontal planes. Above the roof height, the maximum tangential velocity is lower in the Community case under tornadic winds than that in the Single-building case under tornadic winds because of the higher surface friction in the Community case; below the roof height, greater tangential velocity and pressure are observed in the Community case under tornadic wind fields, and more unfavorable conditions are observed in the Community case under tornadic winds than under the equivalent straight-line winds.

Assessment of ASCE 7-10 for wind effects on low-rise wood frame buildings with database-assisted design methodology

  • He, Jing;Pan, Fang;Cai, C.S.
    • Wind and Structures
    • /
    • v.27 no.3
    • /
    • pp.163-173
    • /
    • 2018
  • The design wind pressure for low-rise buildings in the ASCE 7-10 is defined by procedures that are categorized into the Main Wind Force-Resisting System (MWFRS) and the Components and Cladding (C&C). Some of these procedures were originally developed based on steel portal frames of industrial buildings, while the residential structures are a completely different structural system, most of which are designed as low-rise light-frame wood constructions. The purpose of this study is to discuss the rationality (or irrationality) of the extension of the wind loads calculated by the ASCE 7-10 to the light-frame wood residential buildings that represent the most vulnerable structures under extreme wind conditions. To serve this purpose, the same approach as used in the development of Chapter 28 of the ASCE 7-10 that envelops peak responses is adopted in the present study. Database-assisted design (DAD) methodology is used by applying the dynamic wind loads from Louisiana State University (LSU) database on a typical residential building model to assess the applicability of the standard by comparing the induced responses. Rather than the postulated critical member demands on the industrial building such as the bending moments at the knee, the maximum values at the critical points for wood frame buildings under wind loads are used as indicators for the comparison. Then, the critical members are identified through these indicators in terms of the displacement or the uplift force at connections and roof envelope. As a result, some situations for each of the ASCE 7 procedures yielding unconservative wind loads on the typical low-rise residential building are identified.

Investigation of the Vortex Shedding with the Spring Mounted Circular Cylinder (스프링장착 원통형 실린더를 이용한 와류발산현상 파악)

  • Lee, Sang-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.11
    • /
    • pp.446-451
    • /
    • 2010
  • To investigate the vortex induced vibrations the 2-d.o.f. spring mounted circular cylinder was tested in the wind tunnel. The circular cylinder was designed to have the translational and the rotational mode uncoupled to each other. During the wind tunnel tests the resonance behaviors of the translational and the rotational modes by the locking-on phenomena were observed. From the locking-on phenomena observed it is shown that the vortex shedding is correlated with the responses of the structures. And the forces generated by the vortex shedding are influenced by the amplitudes and the frequencies of the cylinders.

Simulation of Atmospheric Dispersion over the Yosu Area -I. Terrain Effects- (여수지역 대기확산의 수치 모사 -I. 지형의 영향-)

  • 김영성;오현선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.3
    • /
    • pp.211-223
    • /
    • 2000
  • The atmospheric dispersion of a pollutant emitted from a hypothetical source located in the middle of the Yochon Industrial Estate was simulated by using the Regional Atmospheric Modeling System (RAMS). Four horizontally nested grids were employed: the coarsest one covered the southern part of the Korean Peninsula including Mt. Chiri and the finest one covered the Yochon Industrial Estate and the surrounding area. Wind fields were initially assumed horizontally homogeneous with a wind speed of 4m/s, the average for the Yosu area, and were developed without both external forces and diurnal changes in order to investigate the terrain-induced phenomena. Wind directions that could emphasize the terrain effects on the pollutant transport and that could carry pollutants to a highly-popluated area were selected for the dispersion study. A pollutant was released for 24hours from a grid-base volume source after a 24-h blank run for developing the wind field. The dispersion study showed that the pollutant from the present source location did not directly affect the Yosu City, but showed high concentrations at locations behind the hills 5 to 6 km away from the source according to wind directions. When the wind speed was low, close to calm condition, the pollutant was detected at upstream locations 6 to 7 km from the source. In comparison with the results from the RAMS simulation, the Industrial Source Complex Short-Term Model(ISCST3) predicted a narrow dispersion that was sensitive to the wind direction. When the wind velocity was affected by the local environment, the ISCST3 calculation using that data also gave a lop-sided result, which was different from the distribution of the pollutant reproduced by RAMS.

  • PDF

Aeroelastic modeling to investigate the wind-induced response of a multi-span transmission lines system

  • Azzi, Ziad;Elawady, Amal;Irwin, Peter;Chowdhury, Arindam Gan;Shdid, Caesar Abi
    • Wind and Structures
    • /
    • v.34 no.2
    • /
    • pp.231-257
    • /
    • 2022
  • Transmission lines systems are important components of the electrical power infrastructure. However, these systems are vulnerable to damage from high wind events such as hurricanes. This study presents the results from a 1:50 scale aeroelastic model of a multi-span transmission lines system subjected to simulated hurricane winds. The transmission lines system considered in this study consists of three lattice towers, four spans of conductors and two end-frames. The aeroelastic tests were conducted at the NSF NHERI Wall of Wind Experimental Facility (WOW EF) at the Florida International University (FIU). A horizontal distortion scaling technique was used in order to fit the entire model on the WOW turntable. The system was tested at various wind speeds ranging from 35 m/s to 78 m/s (equivalent full-scale speeds) for varying wind directions. A system identification (SID) technique was used to evaluate experimental-based along-wind aerodynamic damping coefficients and compare with their theoretical counterparts. Comparisons were done for two aeroelastic models: (i) a self-supported lattice tower, and (ii) a multi-span transmission lines system. A buffeting analysis was conducted to estimate the response of the conductors and compare it to measured experimental values. The responses of the single lattice tower and the multi-span transmission lines system were compared. The coupling effects seem to drastically change the aerodynamic damping of the system, compared to the single lattice tower case. The estimation of the drag forces on the conductors are in good agreement with their experimental counterparts. The incorporation of the change in turbulence intensity along the height of the towers appears to better estimate the response of the transmission tower, in comparison with previous methods which assumed constant turbulence intensity. Dynamic amplification factors and gust effect factors were computed, and comparisons were made with code specific values. The resonance contribution is shown to reach a maximum of 18% and 30% of the peak response of the stand-alone tower and entire system, respectively.

Influence of latitude wind pressure distribution on the responses of hyperbolodial cooling tower shell

  • Zhang, Jun-Feng;Ge, Yao-Jun;Zhao, Lin
    • Wind and Structures
    • /
    • v.16 no.6
    • /
    • pp.579-601
    • /
    • 2013
  • Interference effects are of considerable concern for group hyperboloidal cooling towers, but evaluation methods and results are different from each other because of the insufficient understanding on the structure behavior. Therefore, the mechanical performance of hyperboloidal cooling tower shell under wind loads was illustrated according to some basic properties drawn from horizontal rings and cantilever beams. The hyperboloidal cooling tower shell can be regarded as the coupling of horizontal rings and meridian cantilever beams, and this perception is beneficial for understanding the mechanical performance under wind loads. Afterwards, the mean external latitude wind pressure distribution, CP(${\theta}$), was artificially adjusted to pursue the relationship between different CP(${\theta}$) and wind-induced responses. It was found that the maximum responses in hyperboloidal cooling tower shell are primarily dominated by the non-uniformity of CP(${\theta}$) but not the local pressure amplitude CP or overall resistance/drag coefficient CD. In all the internal forces, the maximum amplitude of meridian axial tension shows remarkable sensitivity to the variation of CP(${\theta}$) and it's also the controlling force in structure design, so it was selected as an indicator to evaluate the influence of CP(${\theta}$) on responses. Based on its sensitivity to different adjustment parameters of CP(${\theta}$), an comprehensive response influence factor, RIF, was deduced to assess the meridian axial tension for arbitrary CP(${\theta}$).

Long-term monitoring of super-long stay cables on a cable-stayed bridge

  • Shen, Xiang;Ma, Ru-jin;Ge, Chun-xi;Hu, Xiao-hong
    • Wind and Structures
    • /
    • v.27 no.6
    • /
    • pp.357-368
    • /
    • 2018
  • For a long cable-stayed bridge, stay cables are its most important load-carrying components. In this paper, long-term monitoring of super-long stay cables of Sutong Bridge is introduced. A comprehensive data analysis procedure is presented, in which time domain and frequency domain based analyses are carried out. In time domain, the vibration data of several long stay cables are firstly analyzed and the standard deviation of the acceleration of stay cables, and its variation with time are obtained, as well as the relationship between in-plane vibration and out-plane vibration. Meanwhile, some vibrations such as wind and rain induced vibration are detected. Through frequency domain analysis, the basic frequencies of the stay cables are identified. Furthermore, the axial forces and their statistical parameters are acquired. To investigate the vibration deflection, an FFT-based decomposition method is used to get the modal deflection. In the end, the relationship between the vibration amplitude of stay cables and the wind speed is investigated based on correlation analysis. Through the adopted procedure, some structural parameters of the stay cables have been derived, which can be used for evaluating the component performance and corresponding management of stay cables.

A Study on the Installation method of the Spacer Damper for Bundled T/L (송전선로 스페이서댐퍼 적정 설치방안 연구)

  • Lee, H.K.;Sohn, H.K.;Lee, D.I.;Wi, H.B.;Park, W.D.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.436-438
    • /
    • 2003
  • Wind-induced oscillations are known to cause damage to the conductors and related hardware through fatigue, clashing of the bundled conductors and bolt loosening. Wake-induced oscillations have been known since the advent of bundled conductors, they are caused by aerodynamically unstable forces acting on the leeward conductors in the wake of the windward conductors, They take the form of horizontal galloping, snaking or rolling, in which case all subconductors move together in unison. They can also take the form of the subspan oscillation, which appear as elliptical motions of the subconductors moving out of phase, mainly in the horizontal plane within a subspan. In order to decrease amplitudes of the oscillation, this paper examines the application status of the spacer dampers and suggests proper installation methods.

  • PDF