• Title/Summary/Keyword: wind turbines

Search Result 659, Processing Time 0.025 seconds

Modal Analysis of Filament-wound Composite Towers for Large Scale Wind-Turbine (대형 풍력 발전용 필라멘트 와인딩 복합재 타워의 고유 진동수 해석에 관한 연구)

  • Hong, Gheol-Hyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.73-78
    • /
    • 2011
  • The purpose of this study was to investigate the natural frequency of filament-wound composite towers for large scale wind-turbines using the finite element method (FEM). To define the material properties, we used both the effective property method and the stacking properties method. The effective properties method assumes that a composite consists of one ply. The stacking properties method assumes that a composite consists of several stacked plies. First, a modal analysis of the tower, filament-wound with angles of $[{\pm}30]$, was carried out using the two methods for composite material properties, the stacking method and effective method. Then, an FE analysis was performed for composite towers using filament winding angles of $[{\pm}30]$, $[{\pm}45]$, and $[{\pm}60]$. The FE analysis results using the stacking properties of the composite were in good agreement with the results from the effective properties method. The difference between the FEM and material properties methods was approximately 0~0.6%

Buckling Analysis of Filament-wound Composite Towers for Large Scale Wind-Turbine (대형 풍력발전용 필라멘트 와인딩 복합재 타워의 좌굴 해석)

  • Han, Jeong-Young;Hong, Cheol-Hyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.79-84
    • /
    • 2011
  • The purpose of this study was to investigate the buckling load of filament-wound composite towers for large scale wind-turbines using the finite element method (FEM). To define the material properties, we used both the effective property method and stacking properties method. The effective properties method assumes that a composite consists of one ply. The stacking properties method assumes that a composite consists of several stacked plies. First, a linear buckling analysis of the tower, filament-wound with angles of $[{\pm}60]$, was carried out using the two methods for composite material properties: the stacking method and effective method. An FE analysis was also performed for the composite towers using the filament winding angles of $[{\pm}30]$, $[{\pm}45]$, and $[{\pm}60]$. The FE analysis results using the stacking properties of the composite were in good agreement with the results from the effective properties method. The difference between the FEM results and material properties method was approximately 0~2.3%. Above the angle of $[{\pm}60]$, there was little change in the buckling load.

Investigation of wake characteristics in turbulence of stable atmospheric boundary layer (안정경계층 난류에서의 터빈 후류 특성 연구)

  • Na, Jisung;Ko, Seungchul;Lee, Joon Sang
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.3
    • /
    • pp.28-31
    • /
    • 2016
  • In this study, we investigate the wake characteristics in two cases which are laminar inflow and turbulent inflow. To solve the flow with wind turbines and its wake, we use large eddy simulation (LES) technique with actuator line method (ALM) and turbulent inflow of Turbsim. Turbulent inflow which contains the characteristic of the stable atmospheric boundary layer is used. We perform the quantitative analysis of velocity deficit and turbulence intensity in two cases. Time series of velocity deficit at the first, the second column in two cases are compared to observe the performance of wind turbine. The performance in the first column in laminar inflow is overestimated compared to that in turbulent inflow. And we observe that wake in the case with turbulent inflow drive to the span-wise direction and wake recovery in turbulent inflow is more effective. In quadrant analysis of Reynolds stress, the ejection and the sweep motion in turbulent inflow case are bigger than those in laminar inflow case.

Aerodynamic Analysis of the NREL Phase Ⅵ Rotor using the CFD (NREL Phase Ⅵ 로터에 대한 공력해석)

  • Kang, Tae-Jin;Lee, Sea-Wook;Cho, Jin-Soo;Gyeong, Namho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.4
    • /
    • pp.315-320
    • /
    • 2008
  • This paper describes aerodynamic characteristics for the NREL(National Renewable Energy Laboratory) Phase VI rotor using the Fluent which is a commercial flow analysis tool. Aerodynamic analysis results are compared with experimental results by the NREL/NASA Ames wind tunnel tests. For three velocity cases, computed results are compared with experiment results at five spanwise positions. Computed results represented good agreement with the experimental results at low velocity. Otherwise computed results in suction side represents disagreement with the experimental results at high velocity. When interval between wind turbines is 10 times of rotor diameter, CFD research is performed to calculate the wake effect.

Influence of failed blade-pitch-control system to FOWT by aero-elastic-control-floater-mooring coupled dynamic analysis

  • Bae, Yoon Hyeok;Kim, Moo-Hyun
    • Ocean Systems Engineering
    • /
    • v.3 no.4
    • /
    • pp.295-307
    • /
    • 2013
  • More FOWTs (floating offshore wind turbines) will be installed as relevant regulations and technological hurdles are removed in the coming years. In the present study, a numerical prediction tool has been developed for the fully coupled dynamic analysis of FOWTs in time domain including aero-loading, tower elasticity, blade-rotor dynamics and control, mooring dynamics, and platform motions so that the influence of rotor-control dynamics on the hull-mooring performance and vice versa can be assessed. The developed coupled analysis program is applied to Hywind spar design with 5 MW turbine. In case of spar-type floaters, the control strategy significantly influences the hull and mooring dynamics. If one of the control systems fails, the entire dynamic responses of FOWT can be significantly different. Therefore, it is important to maintain various control systems in a good operational condition. In this regard, the effects of failed blade pitch control system on FOWT performance including structural and dynamic responses of blades, tower, and floater are systematically investigated. Through this study, it is seen that the failure of one of the blade pitch control system can induce significant dynamic loadings on the other blades and the entire FOWT system. The developed technology and numerical tool are readily applicable to any types of floating wind farms in any combinations of irregular waves, dynamic winds, and steady currents.

Power Quality Analysis of Sungsan Substation Bus Connected to Hangwon Wind Farm (행원풍력단지와 연계된 성산변전소 모선의 전기품질 분석)

  • Ahn, J.H.;Ko, S.M.;Na, K.Y.;Kim, S.H.;Kim, H.C.;Kim, Y.H.;Choi, B.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.146-148
    • /
    • 2005
  • The number of wind generation installations are growing substantially in Jeju, Korea. Many of these installations are significant in size and directly connected to the distribution system. In these distributed applications, it is not uncommon for the turbines to be connected near the end of a long rural distribution feeder from which end-users are served. Therefore, utility grid interconnection standards for interconnecting non-utility distributed generation systems are essential to both power system company and generation company. In this paper, it is investigated the power quality of Sungsan substation bus connected to Hangwon wind power generation farm.

  • PDF

Predicting Double-Blade Vertical Axis Wind Turbine Performance by a Quadruple-Multiple Streamtube Model

  • Hara, Yutaka;Kawamura, Takafumi;Akimoto, Hiromichi;Tanaka, Kenji;Nakamura, Takuju;Mizumukai, Kentaro
    • International Journal of Fluid Machinery and Systems
    • /
    • v.7 no.1
    • /
    • pp.16-27
    • /
    • 2014
  • Double-blade vertical axis wind turbines (DB-VAWTs) can improve the self-starting performance of lift-driven VAWTs. We here propose the quadruple-multiple streamtube model (QMS), based on the blade element momentum (BEM) theory, for simulating DB-VAWT performance. Model validity is investigated by comparison to computational fluid dynamics (CFD) prediction for two kinds of two-dimensional DB-VAWT rotors for two rotor scales with three inner-outer radius ratios: 0.25, 0.5, and 0.75. The BEM-QMS model does not consider the effects of an inner rotor on the flow speed in the upwind half of the rotor, so we introduce a correction factor for this flow speed. The maximum power coefficient predicted by the modified BEM-QMS model for a DB-VAWT is thus closer to the CFD prediction.

Measurement and Monitoring of Mechanical Loads of Wind Turbines Using Distributed Fiber Optic Sensor (분포형 광섬유 센서를 이용한 풍력발전기의 기계적 부하 측정 및 모니터링)

  • Lee, Jong-Won;Huh, Young-Cheol;Nam, Yong-Yun;Lee, Geun-Ho;Kim, Yoo-Sung;Lee, Yong-Bae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1028-1036
    • /
    • 2007
  • A method for measurement and monitoring of mechanical loads in large slender structures such as wind turbine blade and tower is presented based on continuous strain data obtained from distributed fiber optic sensor. An experimental study was carried out on an aluminum cantilever beam. A static load test was performed and the calculated moment from the distributed fiber optic sensor agree well with the actual applied moment. A series of damages was inflicted on the beam, and vibration tests were carried out for each damage case. The estimated natural frequencies from the distributed fiber optic sensor for each damage case are found to compare well with those from a conventional accelerometer and a numerical analysis based on an energy method.

Semi-active control of vibrations of spar type floating offshore wind turbines

  • Van-Nguyen, Dinh;Basu, Biswajit;Nagarajaiah, Satish
    • Smart Structures and Systems
    • /
    • v.18 no.4
    • /
    • pp.683-705
    • /
    • 2016
  • A semi-active algorithm for edgewise vibration control of the spar-type floating offshore wind turbine (SFOWT) blades, nacelle and spar platform is developed in this paper. A tuned mass damper (TMD) is placed in each blade, in the nacelle and on the spar to control the vibrations for these components. A Short Time Fourier Transform algorithm is used for semi-active control of the TMDs. The mathematical formulation of the integrated SFOWT-TMDs system is derived by using Euler-Lagrangian equations. The theoretical model derived is a time-varying system considering the aerodynamic properties of the blade, variable mass and stiffness per unit length, gravity, the interactions among the blades, nacelle, spar, mooring system and the TMDs, the hydrodynamic effects, the restoring moment and the buoyancy force. The aerodynamic loads on the nacelle and the spar due to their coupling with the blades are also considered. The effectiveness of the semi-active TMDs is investigated in the numerical examples where the mooring cable tension, rotor speed and the blade stiffness are varying over time. Except for excessively large strokes of the nacelle TMD, the semi-active algorithm is considerably more effective than the passive one in all cases and its effectiveness is restricted by the low-frequency nature of the nacelle and the spar responses.

An Optimal Installation Strategy for Allocating Energy Storage Systems and Probabilistic-Based Distributed Generation in Active Distribution Networks

  • Sattarpour, Tohid;Tousi, Behrouz
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.6
    • /
    • pp.350-358
    • /
    • 2017
  • Recently, owing to increased interest in low-carbon energy supplies, renewable energy sources such as photovoltaics and wind turbines in distribution networks have received considerable attention for generating clean and unlimited energy. The presence of energy storage systems (ESSs) in the promising field of active distribution networks (ADNs) would have direct impact on power system problems such as encountered in probabilistic distributed generation (DG) model studies. Hence, the optimal procedure is offered herein, in which the simultaneous placement of an ESS, photovoltaic-based DG, and wind turbine-based DG in an ADN is taken into account. The main goal of this paper is to maximize the net present value of the loss reduction benefit by considering the price of electricity for each load state. The proposed framework consists of a scenario tree method for covering the existing uncertainties in the distribution network's load demand as well as DG. The collected results verify the considerable effect of concurrent installation of probabilistic DG models and an ESS in defining the optimum site of DG and the ESS and they demonstrate that the optimum operation of an ESS in the ADN is consequently related to the highest value of the loss reduction benefit in long-term planning as well. The results obtained are encouraging.