• Title/Summary/Keyword: wind turbines

Search Result 659, Processing Time 0.025 seconds

A Study on Development of Test Site for Wind Turbine Prototype Test (풍력터빈시험을 위한 실증시험장 개발에 관한 연구)

  • Moon, Chae-Joo;Chang, Young-Hag;So, Soon-Yeol;Kim, Tae-Gon;Kim, Young-Gon;Jeong, Moon-Seon;Jeong, Seong-Won
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.101-107
    • /
    • 2013
  • It is evident that in the wind energy business as an economic activity there is a close relationship between the wind speed and the revenues. The wind turbine test facility for wind turbine accreditation is intended to be used by the industry for testing of both main components and systems. This paper suggest the wind test site for certification of prototype wind turbine with international regulations. The test site has an environmental permit for wind turbines with a maximum hub height of 120m and a rotor diameter up to 120m, and can accommodate prototypes with installed electrical powers up to 5MW each. A wind turbine manufacturer can lease the location for a period of type certification. And also researchers are the development of new methods for measuring the influence, performance and durability of the components, a mathematical and numerical modelling of component responses by using the site.

Short-term fatigue analysis for tower base of a spar-type wind turbine under stochastic wind-wave loads

  • Li, Haoran;Hu, Zhiqiang;Wang, Jin;Meng, Xiangyin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.1
    • /
    • pp.9-20
    • /
    • 2018
  • Due to integrated stochastic wind and wave loads, the supporting platform of a Floating Offshore Wind Turbine (FOWT) has to bear six Degrees of Freedom (DOF) motion, which makes the random cyclic loads acting on the structural components, for instance the tower base, more complicated than those on bottom-fixed or land-based wind turbines. These cyclic loads may cause unexpected fatigue damages on a FOWT. This paper presents a study on short-term fatigue damage at the tower base of a 5 MW FOWT with a spar-type platform. Fully coupled time-domain simulations code FAST is used and realistic environment conditions are considered to obtain the loads and structural stresses at the tower base. Then the cumulative fatigue damage is calculated based on rainflow counting method and Miner's rule. Moreover, the effects of the simulation length, the wind-wave misalignment, the wind-only condition and the wave-only condition on the fatigue damage are investigated. It is found that the wind and wave induced loads affect the tower base's axial stress separately and in a decoupled way, and the wave-induced fatigue damage is greater than that induced by the wind loads. Under the environment conditions with rated wind speed, the tower base experiences the highest fatigue damage when the joint probability of the wind and wave is included in the calculation. Moreover, it is also found that 1 h simulation length is sufficient to give an appropriate fatigue damage estimated life for FOWT.

Saemangeum feasibility study for offshore wind in yeongeunhae Remote monitoring pungryeokgecheuk (새만금 연근해의 해상풍력 타당성 조사를 위한 원격감시 풍력계측)

  • Choi, Yeon-Sung;Choi, Yong-Won;Jeon, Chil-Hwan
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.3
    • /
    • pp.3-8
    • /
    • 2009
  • Environmental pollution caused by fossil fuel use and energy sources, the big concern is the rise of the current situation, one of the ways to overcome the interest in renewable energy is Gozo. Located on the west coast, especially the Saemangeum area and the northwest wind, the big advantage of the vast area that's got quite a number of wind turbines is expected. This study affirms that these expectations can be a wind energy resource survey sea area of the average wind speed of Kunsan 5 ~ 7m / s is enough, books are linked to the local marine wind farms can safely say that none of choejeokji said. In addition, the emergence of the wind resource to determine the density of the Weibull distribution is calculated using the number 1, the shape factor as a parameter to calculate the density of the wind a result, Gunsan Province was able to predict the emergence of the wind. In addition, by controlling the remote monitoring through the measurement exceeded the convenience and reliability at the same time you can achieve great results.

  • PDF

Analysis of the Multi-layered Soil on Monopile Foundation of Offshore Wind Turbine (해상 풍력 타워의 모노파일 기초에 대한 다층 지반 해석)

  • Kim, Nam-Hyeong;Go, Myeong-Jin
    • Journal of Navigation and Port Research
    • /
    • v.37 no.6
    • /
    • pp.655-662
    • /
    • 2013
  • Recently, by the problems owing to utilization of fossil fuel, various green energies receive attention. Wind, the impetus for the wind power generation as one of the green energies, is observed higher quality value in the offshore than onshore. Also, the development of offshore wind turbines is in the spotlight as alternative to solve the problems of onshore wind farm such as securing sites, noise, and electromagnetic waves, and to get efficient wind energy. Therefore, the many researches on offshore wind energy have been carried out. As wind towers are advanced to ocean, offshore wind towers have been enlarged. Thus, stability is required to endure wind force and wave force. In this study, the external forces act on the foundation in multi-layered are calculated by p-y relation.

CCT Analysis of Power System Connected to DFIG Wind Turbine (DFIG 풍력터빈이 연계된 전력계통의 CCT 영향분석)

  • Seo, Gyu-Seok;Park, Ji-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2388-2392
    • /
    • 2013
  • Wind generation systems are very different in nature from conventional generation systems. Therefore it is necessary to research dynamic characteristics of wind generation systems connected to a power system. The stability analysis of wind turbine generator is an important issue in the operation of the power system. The result of angular stability of the power system that consists of only synchronous generators is different from that of the power system including wind turbine generators. This is due to the fact that generators connected to wind turbines are generally induction generators. The angular stability assessing synchronization of generators is determined by its corresponding critical clearing time(CCT). Wind turbine models for the analysis of power system are varied and difficult to use, but now these are standardized into four types. In this paper, the analysis of the CCT of the power system connected to wind farm considering the location and capacity is performed by using DFIG(Doubly-Fed induction Generator) wind turbine built-in type3 model in PSS/E-32.

New approach to calculate Weibull parameters and comparison of wind potential of five cities of Pakistan

  • Ahmed Ali Rajput;Muhammad Daniyal;Muhammad Mustaqeem Zahid;Hasan Nafees;Misha Shafi;Zaheer Uddin
    • Advances in Energy Research
    • /
    • v.8 no.2
    • /
    • pp.95-110
    • /
    • 2022
  • Wind energy can be utilized for the generation of electricity, due to significant wind potential at different parts of the world, some countries have already been generating of electricity through wind. Pakistan is still well behind and has not yet made any appreciable effort for the same. The objective of this work was to add some new strategies to calculate Weibull parameters and assess wind energy potential. A new approach calculates Weibull parameters; we also developed an alternate formula to calculate shape parameters instead of the gamma function. We obtained k (shape parameter) and c (scale parameter) for two-parameter Weibull distribution using five statistical methods for five different cities in Pakistan. Maximum likelihood method, Modified Maximum likelihood Method, Method of Moment, Energy Pattern Method, Empirical Method, and have been to calculate and differentiate the values of (shape parameter) k and (scale parameter) c. The performance of these five methods is estimated using the Goodness-of-Fit Test, including root mean square error, mean absolute bias error, mean absolute percentage error, and chi-square error. The daily 10-minute average values of wind speed data (obtained from energydata.info) of different cities of Pakistan for the year 2016 are used to estimate the Weibull parameters. The study finds that Hyderabad city has the largest wind potential than Karachi, Quetta, Lahore, and Peshawar. Hyderabad and Karachi are two possible sites where wind turbines can produce reasonable electricity.

New Development of Hybrid Concrete Support Structure with Driven Piles for Offshore Wind Turbines (하이브리드 해상풍력 파일 기초 콘크리트 지지구조(MCF) 개발)

  • Kim, Hyun Gi;Kim, Bum Jun;Kim, Ki Du
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.307-320
    • /
    • 2013
  • This paper proposes a new hybrid support structure by the driven piles which removes disadvantages of the existing type of support structure for offshore wind turbines. The hybrid type of support structure is combined with concrete cone and steel shaft, and is supported not only by gravity type foundations but also by driven piles. For three dimensional analysis of the huge and thick concrete structure, a solid-shell element that is capable of exact modeling and node interpolations of stresses is developed. By applying wave theory of stream function and solid-shell element in XSEA simulation software for fixed offshore wind turbines, a quasi-static analysis and natural frequency analysis of proposed support structure are performed with the environmental condition on Southwest Coast in Korea. In the result, lateral displacement is not exceed allowable displacement and a superiority of dynamic behavior of new hybrid support structure is validated by natural frequency analysis. Consequently, the hybrid support structure presented in this study has a structural stability enough to be applied on real-site condition in Korea. The optimized structures based on the preliminary design concept resulted in an efficient structure, which reasonably reduces fabrication costs.

An analysis of horizontal deformation of a pile in soil using a continuum soil model for the prediction of the natural frequency of offshore wind turbines (해상풍력터빈의 고유진동수 예측을 위한 지반에 인입된 파일의 연속체 지반 모델 기반 수평 거동 해석)

  • Ryue, Jungsoo;Baik, Kyungmin;Lee, Jong-Hwa
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.480-490
    • /
    • 2016
  • As wind turbines become larger and lighter, they are likely to respond sensitively by dynamic loads applied on them. Since the responses at resonances are particularly interested, it is required to be able to predict natural frequencies of wind turbines reliably at early design stage. To achieve this, the foundation-soil analysis is needed to be carried out and a finite element approach is adopted in general. However, the finite element approach would not be appropriate in early design stage because it demands heavy efforts in pile-soil modelling and computing facilities. On the contrary, theoretical approaches adopting linear approximations for soils are relatively simple and easy to handle. Therefore, they would be a useful tool in predicting a pile-soil interaction, particularly in early design stage. In this study an analysis for a pile inserted in soil is performed. The pile and soil are modelled as a beam and continuum medium, respectively, within an elastic range. In this analysis, influence factors at the pile head for lateral loads are predicted by means of this continuum approach for various length-diameter ratios of the pile. The influence factors predicted are validated with those reported in literature, proposed from a finite element analysis.

Wind Speed Estimation using Regression Method for Maximum Power Control (리그레션 방법을 이용한 최대출력제어 풍속예측)

  • Ko, SeungYoun;Kim, Ho-Chan;Huh, Jong-Chul;Kang, Min-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.4
    • /
    • pp.327-333
    • /
    • 2015
  • Wind turbines, in the case of less than rated wind speed, is controlled to achieve maximum power. MPC(Maximun Power Control) method, by controlling the rotational speed of the generator, is a method to achieve maximum power but should know the wind speed. However, for several reasons, there have been proposed methods of estimating the wind speed rather than measuring wind speed. TSR(Tip Speed Ratio) is needed to know to estimate the wind speed. However, a complex interaction formula has to be solved to find a TSR. Therefore, many methods have been suggested to solve a complex interaction formula. In this paper, the new method has been proposed to simplify the complicated interaction formula by using the regression method. Matlab/Simulink is used to simulate and to verify the proposed method.

A Study on Design of Control Device on Small Wind Generator Using 2-Level Boost Converter (2레벨용 부스트 컨버터를 이용한 소형풍력발전기 제동장치 설계에 관한 연구)

  • Moon, Chae-Joo;Chang, Young-Hak;So, Soon-Youl;Park, Tae-Sik;Jeong, Moon-Seon;Youn, Young-Chan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1481-1486
    • /
    • 2013
  • The small wind generator with existing mechanical control system has a frequent failure and malfunction, and its maintenance is difficult. In this paper, an electric control method using a boost converter for small wind generator was suggested. The suggested 2-level boost converter control device was manufactured and its experimental operation were conducted on a wind generator with 200 [W] capacity. As a result of experimental device, the control by a boost converter was executed at the point that the output voltage of a wind generator became 36 [V] so it could be identified that the output voltage of a wind generator diminished and then it became 0 [V] after 5 [sec]. Besides, in case of applying the method suggested in this paper to a small wind power generation facility for street lights, it is expected to reduce its maintenance by preventing a frequent failure of a generator and to improve its utilization rate.