• Title/Summary/Keyword: wind turbines

Search Result 638, Processing Time 0.038 seconds

International Standardization of Reliability Assessment for Wind Turbines and Wind Farms (풍력발전기 및 풍력발전단지 신뢰성 평가 국제 표준화)

  • Kim, Seokwoo
    • Journal of Wind Energy
    • /
    • v.9 no.4
    • /
    • pp.5-8
    • /
    • 2018
  • Optimum performance and reliable operation of wind turbines and/or wind farms are crucial parameters for stakeholders such as OEMs, operators, owners and investors. The efficiency and life time of wind power heavily depends on operation and maintenance efforts. Every manufacturer or owner wants to have wind turbines with high reliability, which can be defined as the probability that a wind turbine will perform its designed function for a certain period of time under stated conditions. In this regard, IEC WG26 is now developing a technical specification defining information categories from which reliability metrics can be identified and reported.

Modifying the aggregated wind farm model with a controller

  • Badr, Mohammed. A.;Atallah, Ahmed. M.;Bayoumi, Mona A.
    • Advances in Energy Research
    • /
    • v.3 no.3
    • /
    • pp.133-142
    • /
    • 2015
  • A large wind farm can be simplified by the aggregated wind farm models for load flow, steady and transient stability studies. When a fault (such as a short circuit) happens in a large wind farm, some of wind turbines trip while others do not. This paper is to design a controller to modify the aggregated wind farm model in the case of one or more unit removed or added from the complete model. This is without stopping the simulation process during performing the steady state and transient analysis of the whole system. This controller can modulate the status of the wind turbines in the aggregated model in a given farm according to any change in this farm. By this controller, we save effort and time to change the status of wind turbines in the aggregated model. The proposed wind farm is composed of some smaller farms of permanent magnet synchronous generators (PMSGs) and others of squirrel cage induction generators (SCIGs).

Load Flow Calculation and Short Circuit Faults Transients in Dispersed Generation Systems

  • Hosseini, Seyed Hossein;Shahnia, Farhad;Tizghadam, Saeed
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.800-804
    • /
    • 2005
  • Load flow and short circuit fault transients of a power distribution system with wind turbines as dispersed generation units is presented. Usage of renewable energies such as wind is already a small part of total installed power system in medium and low voltage networks. In this paper, a radial power distribution system with wind turbines is simulated using DIgSILENT PowerFactory software for their influence on load flow and short circuit fault transients. Short fault occurring in dispersed generation systems causes some problems for the system and costumers such as fault level increase or the problems of sudden fluctuations in the current, voltage, power and torque of the double fed induction machine utilized in the wind turbines which have been studied and investigated.

  • PDF

Overall Vibration Values for Reliable Wind Turbines - The New VDI 3834 and the New ISO 10816-21 Guideline Close a Gap - Less Vibration is Better -

  • Becker, Edwin
    • Journal of KSNVE
    • /
    • v.22 no.4
    • /
    • pp.28-32
    • /
    • 2012
  • Condition-based maintenance on wind turbines not only involves maintenance, but also encompasses servicing, inspection, measurement and evaluation of the condition of the unit. The current condition can be evaluated on the basis of machine-specific overall vibration values. Until now, overall vibration values had not been defined for wind turbines. In fact, ISO 10816-3 explicitly excludes wind power plants. The new VDI 3834 closes this gap shown in Sheet 1: Vibration values for wind turbines up to 3 MW. In addition to the new VDI 3834 is the ISO 10816-21 in preparation. The author of the article Dr. Edwin Becker is the nominated expert for Germany.

Numerical analysis on the low noise designs of Savonius wind turbines by using phase difference in vortex shedding (와류이탈 위상차를 이용한 사보니우스형 풍력터빈의 소음 저감 설계에 관한 수치적 연구)

  • Kim, Sanghyeon;Cheong, Cheolung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.166-171
    • /
    • 2013
  • In this study, low noise designs of a Savonius wind turbines are numerically investigated. From a previous study, it was found that the high harmonic components whose fundamental frequency is higher than the BPF were found to be dominant in noise spectrum of a Savonius wind turbine. On a basis of this observation, S-shaped blade tip is proposed as a low design factors that decrease wind turbine noise by inducing phase differences in vortex shedding. The conventional Savonius and S-shaped turbines are investigated using Hybrid CAA method where flow field around the turbine are computed using CFD techniques and the radiated noise are predicted by applying acoustic analogy to the computed flow data. Noise reductions by these design factors are confirmed by comparing the predicted noise levels from these turbines.

  • PDF

Design of an LCL-Filter for Three-Parallel Operation of Power Converters in Wind Turbines

  • Jeong, Hae-Gwang;Yoon, Dong-Keun;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.437-446
    • /
    • 2013
  • This paper proposes a design scheme for an LCL-filter used for the three-parallel operation of the power converters in high-capacity wind turbines. The designs of the power devices and grid connected filter are difficult due to the high level voltages and currents in huge-capacity wind turbines. To solve these problem, this paper presents three-parallel operation and LCL-filter design techniques optimized by parallel operation. Furthermore, the design of an inverter side inductance of the LCL-filter is discussed in detail considering the switching modulation method. Simulation and experimental results demonstrate the validity of the designed filter and wind turbines.

Prediction of Aerodynamic Performance on Wind Turbines in the Far Wake (후류 영향을 고려한 풍력 발전 단지 성능 예측 연구)

  • Son, Eunkuk;Kim, Hogeon;Lee, Seungmin;Lee, Soogab
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.59.2-59.2
    • /
    • 2011
  • Although there are many activities on the construction of wind farm to produce amount of power from the wind, in practice power productions are not as much as its expected capabilities. This is because a lack of both the prediction of wind resources and the aerodynamic analysis on turbines with far wake effects. In far wake region, there are velocity deficits and increases of the turbulence intensity which lead to the power losses of the next turbine and the increases of dynamic loadings which could reduce system's life. The analysis on power losses and the increases of fatigue loadings in the wind farm is needed to prevent these unwanted consequences. Therefore, in this study velocity deficits have been predicted and aerodynamic analysis on turbines in the far wake is carried out from these velocity profiles. Ainslie's eddy viscosity wake model is adopted to determine a wake velocity and aerodynamic analysis on wind turbines is predicted by the numerical methods such as blade element momentum theory(BEMT) and vortex lattice method(VLM). The results show that velocity recovery is more rapid in the wake region with higher turbulence intensity. Since the velocity deficit is larger when the turbine has higher thrust coefficient, there is a huge aerodynamic power loss at the downstream turbine.

  • PDF

Optimizing Performance of Wind Turbines

  • Kusiak, Andrew
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.467-470
    • /
    • 2009
  • Variable loads along the drive-train are attributed to frequent failures of gears, bearings, and other components. Wind parameters cannot be controlled and therefore any turbine load-reducing remedies must be established based on proper insights into the wind-turbine interactions. A novel control concept to performance optimization of wind turbines is presented. This proposed concept is based on analysis of the turbine status reflected in the SCADA data. Modern computational techniques are used to optimize performance of a wind turbine from tree basic perspectives: drive-train, power output, and power quality. The proposed approach demonstrates that gains in the metrics representing the three perspectives and the corresponding control goals can be significantly improved for any wind turbine. The solution is applicable different turbine types operating in different wind regimes, e.g., winds of different speeds and variability. Simple and transparent parameters allow an operator to determine a balance between the operations and maintenance, technical, business objectives. The proposed modeling framework was embedded in software. The software tool has been tested on the data collected from 1.5 MW wind turbines.

  • PDF

Bus Voltage Analysis of Substation Connected to the Wind Generation Farm (풍력발전단지와 연계된 변전소의 모선전압 분석)

  • Kim Young Hwan;Hyun Gil Ju;Ko Seok Bum;Yang Ik Jun;Na Kyoung Yun;Kim Se Ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.236-238
    • /
    • 2004
  • In recent years wind turbine technology has undergone the rapid development in response to the demands for increased use of renewable sources of energy. Using wind turbines for production of electrical energy requires reliable operation. The increased share of wind power in electrical system makes it necessary to have grid-friendly interfaces between the wind turbines and the grid in order to maintain power quality. Increasingly wind turbines are being connected into electricity distribution system. The grid-connected wind power stations have many impacts on power systems such as voltage variations, harmonics. The paper investigates the influences of grid-connected wind power generation system on substation bus voltage.

  • PDF

Active load control for wind turbine blades using trailing edge flap

  • Lee, Jong-Won;Kim, Joong-Kwan;Han, Jae-Hung;Shin, Hyung-Kee
    • Wind and Structures
    • /
    • v.16 no.3
    • /
    • pp.263-278
    • /
    • 2013
  • The fatigue load of a turbine blade has become more important because the size of commercial wind turbines has increased dramatically in the past 30 years. The reduction of the fatigue load can result in an increase in operational efficiency. This paper numerically investigates the load reduction of large wind turbine blades using active aerodynamic load control devices, namely trailing edge flaps. The PD and LQG controllers are used to determine the trailing edge flap angle; the difference between the root bending moment and its mean value during turbulent wind conditions is used as the error signal of the controllers. By numerically analyzing the effect of the trailing edge flaps on the wind turbines, a reduction of 30-50% in the standard deviation of the root bending moment was achieved. This result implies a reduction in the fatigue damage on the wind turbines, which allows the turbine blade lengths to be increased without exceeding the designed fatigue damage limit.