• Title/Summary/Keyword: wind tunnel experiment

Search Result 252, Processing Time 0.031 seconds

Determination of aerodynamic configuration of passenger car by wind tunnel experiment (풍동실험에 의한 승용차의 최적외형결정에 관한 연구)

  • 김근호;노오현;조경국
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.56-63
    • /
    • 1983
  • The aerodynamic characteristics of the most popular car (PONY 2) produced in Korea have been experimentally investigated by Seoul National University's wind tunnel. The model (PONY 2) chosen for the wind tunnel was a 1/5 scale of the original car without simulated underbody, cooling air flow and accessories. The measured aerodynamic drag coefficient corrected by JARI formula is 0.45 which is very close to those of small foreign cars. To see the effect of the different configurations on the aerodynamic drag, the modifications have been made by changing the hood slope and backlight slope, and putting the add-on-aerodynamic devices on the orignal shape. The rear spoiler was found the most effective one to reduce the aerodynamic drag. It may be concluded that the considerable aerodynamic drag reduction can be achieved by changing the slopes and A-O-A devices at the proper places of the car.

  • PDF

Numerical Investigation of the Unsteady Adaptive Wall Models in the Unsteady Wind Tunnel Testing (비정상유동 실험시의 비정상 적응벽면 모델의 수치적 연구)

  • Chang Byeong-Hee;Chang Keun-Shik
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.219-224
    • /
    • 1995
  • The adaptive wall test section has distinct advantage over the other devices for reduction of wall interference in the wind tunnel testing. For two-dimensional steady flows the wall adaption strategy has been well established and, in some extent, has been effectively applied to three-dimensional steady flows. For unsteady testing, the wall adaptation is conceptually possible but has never been realized in the wind tunnel experiment. In this study, relatively simple adaptive wall models have been proposed and evaluated through numerical tests. The effect of Mach number, frequency, and amplitude of pitching oscillation on the wall interference reduction has been also studied.

  • PDF

서로 다른 두께 비를 가진 Eppler 387익형에서의 공력특성에 관한 연구

  • Choe, Won-Gyu
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.632-637
    • /
    • 2016
  • This study shows what difference would be made to the aerodynamic characteristic with different thickness ratio of the same airfoil, Eppler 387, at low Reynolds number, at the angle of attack of $0^{\circ}$. Konkuk Univ.'s airfoil has a bigger thickness ratio than that of the original Eppler 387 airfoil. The reason for the thicker camber is a Pt 100 ohm heater mounted inside the Konkuk Univ.'s airfoil and this was assumed to make some differences to aerodynamic characteristic. The comparison of these two airfoils' CFD data, provided by EDSION_CFD, with real experiment that had been made in subsonic wind tunnel at Konkuk Univ. is done. A finer result would come out if the complement of the homogeneity of the wind tunnel's fluid is done in the future.

  • PDF

Investigation on the Effective Calibration of Annubar (다점식 피토관의 효율적인 교정에 대한 연구)

  • Choi Yong-Moon;Choi Hae-Man;Choi Ji-Chul;Hong Kyung-Ki;Han Sang-Woo;Kim Woong-Sun;Chun Se-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.4 s.247
    • /
    • pp.373-380
    • /
    • 2006
  • Annubar is one of popular tools to measure the exhausted gas flow rate from the stacks. For the accurate monitoring of the amount of discharged pollutants, calibration of annubar is very important. Calibration of annubar has been carried out in a wind tunnel. When the length of annubar is longer than the test section size of wind tunnel, it is very difficult to find out typical value of annubar coefficients. So, a measurement technique to calibrate annubar longer than the size of the test section of wind tunnel must be developed. In the present study, an experiment is performed to measure the annubar coefficients in such a limited size of the wind tunnel. The experimental annubar coefficient by using a partial blocking technique is very close to the annubar coefficient of normal condition.

Parameterization of Along-Wind Dispersion Coefficients based on Field and Wind Tunnel Data

  • Kang, Sung-Dae
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_1
    • /
    • pp.11-22
    • /
    • 2001
  • Observations related to the along-wind dispersion of puffs were collected from 12 field sites and from a wind tunnel experiment and used to test simple similarity relations. Because most of the date made use of concentration time series observation from fixed monitors, the basic observation was t, the standard deviation of the concentration time series. This data also allowed the travel time, t, from the source to the receptor to be estimated, from which the puff advective speed ue, could be determined. The along-wind dispersion coefficient, x, was then assumed to equal tue. The data, which extended over four orders of magnitude, supported the similarity relations t=0.1 t and x=1.8 $u^*$t, where t is the travel time and $u^*$ is the friction velocity. About 50% of the observations were within a factor of two of the predictions based on the similarity relations.

  • PDF

Effect of taper on fundamental aeroelastic behaviors of super-tall buildings

  • Kim, Yong Chul;Tamura, Yukio;Yoon, Sung-Won
    • Wind and Structures
    • /
    • v.20 no.4
    • /
    • pp.527-548
    • /
    • 2015
  • Aeroelastic wind tunnel experiments were conducted for conventional and tapered super-tall building models to investigate the effect of taper on fundamental aeroelastic behaviors in various incident flows. Three incident flows were simulated: a turbulent boundary-layer flow representing urban area; a low-turbulent flow; and a grid-generated flow. Results were summarized focusing on the effect of taper and the effect of incident flows. The suppression of responses by introducing taper was profound in the low-turbulence flow and boundary-layer flow, but in the grid-generated flow, the response becomes larger than that of the square model when the wind is applied normal to the surface. The effects of taper and incident flows were clearly shown on the normalized responses, power spectra, stability diagrams and probability functions.

Characteristic of Wind Pressure Distribution on the Roof of Hyperbolic Paraboloid Spatial Structures (쌍곡선포물선 대공간 구조물의 측벽개구율에 따른 지붕의 풍압특성)

  • You, Jang-Youl;You, Ki-Pyo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.1
    • /
    • pp.51-57
    • /
    • 2013
  • There can be diverse causes in the destruction of a large space structure by strong wind such as characteristics of construction materials and changes in internal and external wind pressure of the structure. To evaluate the wind pressure of roof against the large space structure, wind pressure experiment is performed. However, in this wind pressure experiment, peak internal pressure coefficient is set according to the opening of the roof in Korea wind code. In this article, it was tried to identify the change of internal pressure coefficient and the characteristics of wind pressure coefficient acting on the roof by two kinds of opening on the side of the structure with Hyperbolic Paraboloid Spatial Structures roof. When analyzing internal pressure coefficient according to roof shape, it was found that minimum (52%) and maximum (30%~80%) overestimation was made comparing to partial opening type proposed in the current wind load. It is judged that evaluation according to the opening rate of the structure should be made to evaluate the internal pressure coefficient according to load.

CFD and experiment validation on aerodynamic power output of small VAWT with low tip speed ratio (저속 회전형 소형 수직축 풍력발전기의 공기역학적 출력에 대한 CFD 및 실험적 검증)

  • Heo, Young-Gun;Choi, Kyoung-Ho;Kim, Kyung-Chun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.330-335
    • /
    • 2016
  • In this study, aerodynamic characteristics of the blades of a helical-type vertical axis wind turbine(VAWT) have been investigated. For this purpose, a 100-W helical-type vertical axis wind turbine was designed using a design formulae, and a 3D computational fluid dynamics analysis was performed considering wind tunnel test conditions. Through the results of the analysis, the aerodynamic power output and flow characteristics of a helical blade were confirmed. In order to validate the aerodynamic power output obtained through the analysis, a wind tunnel test was performed by using a full-scale helical-type vertical axis wind turbine. The 3D analysis technique was validated by comparing its results with those obtained from the wind tunnel test.

Development of Force Measuring Device in Learning Wind Tunnel Used for Transportation Technology Class (수송 기술에 적합한 학습용 풍동의 힘 측정 장치 개발)

  • Choi, Jun-Seop;Lee, Sung-Gu
    • 대한공업교육학회지
    • /
    • v.32 no.1
    • /
    • pp.117-133
    • /
    • 2007
  • The purpose of this study was to develop the force measuring device of learning wind tunnel, teaching-learning materials in order to enhance understanding of flight principle and give interest about aviation technology in secondary school. The content of this study was consisted of the development and experiment of force measuring device for learning wind tunnel. The main results of this study were as follows: This device developed here is simple structure applying lever principle instead of the comparatively expensive load cell used in engineering college or a aviation research institute and so on. Measurement of lift and drag as well as the comparison experiment of a fluid resistance is possible with only one device developed here. The lift coefficient with angle of attack has shown the same tendency in both of theoretical and experimental values. And the stall phenomenon was found under the larger angle of attack of experimental rather than expected theoretical values. The drag coefficient with angle of attack has shown the same tendency in both of theoretical and experimental values. And drag coefficient the rate of increasement of the experimental values increased more gently than its theoretical values.

Analysis for Aerodynamic Resistance of Chrysanthemum Canopy through Wind Tunnel Test (풍동실험을 통한 국화군락의 공기유동 저항 분석)

  • Yu, In-Ho;Yun, Nam-Kyu;Cho, Myeong-Whan;Lee, In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.17 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • A wind tunnel test was conducted at Protected Horticulture Experiment Station of National Horticultural Research Institute in Busan to find the aerodynamic resistance and quadratic resistance coefficient of chrysanthemum in greenhouse. The internal plants of the CFD model has been designed as a porous media because of the complexity of its physical shapes. Then the aerodynamic resistance value should be input for analyzing CFD model that crop is considered while the value varies by crops. In this study, the aerodynamic resistance value of chrysanthemum canopy was preliminarily found through wind tunnel test. The static pressure at windward increased as wind velocity and planting density increased. The static pressure at leeward decreased as wind velocity increased but was not significantly affected by planting density. The difference of static pressure between windward and leeward increased as wind velocity and planting density increased. The aerodynamic resistance value of chrysanthemum canopy was found to be 0.22 which will be used later as the input data of Fluent CFD model. When the planting distances were $9{\times}9\;cm$, $11{\times}11\;cm$, and $13{\times}13\;cm$, the quadratic resistance coefficients of porous media were found to be 2.22, 1.81, and 1.07, respectively. These values will be used later as the input data of CFX CFD model.