• Title/Summary/Keyword: wet scrubber

Search Result 88, Processing Time 0.024 seconds

Characteristics of Cyclone and Electric Dust Collection Oil Filters for Selective Removal of Fiber Tenter Air Pollutants (섬유 텐터 대기오염물질의 선택적 제거를 위한 싸이클론 및 전기 집진 오일필터의 특성)

  • Jin Ho Jung;Seung Hwan Ryu;Soon Duk Kwon;Yoon Hyun Cho
    • Textile Coloration and Finishing
    • /
    • v.35 no.4
    • /
    • pp.256-273
    • /
    • 2023
  • Among the dyeing industries, the tenter process is a process that improves the quality of fibers by drying and ironing (heat treatment) dyed fabrics, and drugs such as water repellents, antistatic agents, and fiber softeners are mainly used in these tenter processes. These drugs are vaporized in the process of treatment by high temperatures (180 ~ 230℃), and are observed in a complex form such as white smoke, oil mist, and fine dust, causing odor. To treat the complex exhaust gas at the rear end of the tenter facility, most companies operate by installing a wet scrubber and an adsorption tower alone or in parallel, but there are many problems. In particular, the insoluble oil mist at the rear end of the tenter has significantly low processing efficiency in the cleaning dust collection facility, and there is a problem in the facility by adsorption due to the occlusion phenomenon caused by the oil mist. In addition, the odor gas at the rear end of the tenter contains a lot of aldehydes, and in order to improve these various problems, a complex exhaust purification device using cyclone and electric support collector was developed. This study examined the applicability of economical and efficient technology by removing complex air pollution at the rear end of the tenter and applying improved technology than the existing technology.

Effect of Reaction Gases on PFCs Treatment Using Arc Plasma Process (아크 플라즈마를 이용한 과불화합물 처리공정에서 반응가스에 의한 효과)

  • Park, Hyun-Woo;Choi, Sooseok;Park, Dong-Wha
    • Clean Technology
    • /
    • v.19 no.2
    • /
    • pp.113-120
    • /
    • 2013
  • The treatment of chemically stable perflourocompounds (PFCs) requires a large amount of energy. An energy efficient arc plasma system has been developed to overcome such disadvantage. $CF_4$, $SF_6$ and $NF_3$ were injected into the plasma torch directly, and net plasma power was estimated from the measurement of thermal efficiency of the system. Effects of net plasma power, waste gas flow rate and additive gases on the destruction and removal efficiency (DRE) of PFCs were examined. The calculation of thermodynamic equilibrium composition was also conducted to compare with experimental results. The average thermal efficiency was ranged from 60 to 66% with increasing waste gas flow rate, while DRE of PFCs was decreased with increasing gas flow rate. On the other hand, DRE of each PFCs was increased with the increasing input power. Maximum DREs of $CF_4$, $SF_6$ and $NF_3$ were 4%, 15% and 90%, respectively, without reaction gas at the fixed input power and waste gas flow rate of 3 kW and 70 L/min. A rapid increase of DRE was found using hydrogen or oxygen additional gases. Hydrogen was more effective than oxygen to decompose PFCs and to control by-products. The major by-product in the arc plasma process with hydrogen was hydrofluoric acid that is easy to be removed by a wet scrubber. DREs of $CF_4$, $SF_6$ and $NF_3$ were 25%, 39% and 99%, respectively, using hydrogen additional gas at the waste gas flow rate of 100 L/min and the input power of 3 kW.

Thermal-hydraulic behaviors of a wet scrubber filtered containment venting system in 1000 MWe PWR with two venting strategies for long-term operation

  • Dong, Shichang;Zhou, Xiafeng;Yang, Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1396-1408
    • /
    • 2020
  • Filtered containment venting system (FCVS) is one of the severe accident mitigation systems designed to release containment pressurization to maintain its integrity. The thermal-hydraulic behaviors in FCVSs are important since they affect the operation characteristics of the FCVS. In this study, a representative FCVS was modeled by RELAP5/Mod3.3 code, and the Station BlackOut (SBO) was chosen as an accident scenario. The thermal-hydraulic behaviors of an FCVS during long-term operation with two venting strategies (open-and-close strategy, open-and-non-close strategy) and the sensitivity analysis of important parameters were investigated. The results show that the FCVS can operate up to 250 h with a periodic open-and-close strategy during an SBO. Under the combined effects of steam condensation and water evaporation, the solution inventory in the FCVS increases during the venting phase and decreases during the intermission phase, showing a periodic pattern. Under this condition, the appropriate initial water level is 3-4 m; however, it should be adjusted according to the environment temperature. The FCVS can accommodate a decay heat power of 150-260 kW and may need to feed water for a higher decay heat power or drain water for a lower decay heat power during the late phase. The FCVS can function within an opening pressure range from 450 kPa to 500 kPa and a closing pressure range between 250 kPa and 350 kPa. When the open-and-non-close strategy is adopted, the solution inventory increases quickly in the early venting phase due to steam condensation and then decreases gradually due to the evaporation of water; drying-up may occur in the late venting phase. Decreasing the venting pipe diameter and increasing the initial water level can mitigate the evaporation of the scrubbing solution. These results are expected to provide useful references for the design and engineering application of FCVSs.

$CO_2$ Removal Process Case Studies and Plant Performance Analysis for 300MW IGCC Power Plant (300MW 급 IGCC Power Plant $CO_2$ 제거공정의 Case Studies 및 Plant 성능 영향 분석)

  • Jeon, Jinhee;Yoo, Jeongseok;Paek, Minsu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.71.2-71.2
    • /
    • 2011
  • 300MW 급 태안 IGCC 가스화 플랜트 및 기존 발전소에 CCS 를 설치할 경우에 대해 기술 타당성 검증을 목적으로 CCS 모델링을 수행하였다. CCS Case Studies 는 플랜트 운전부하에 따른 $CO_2$ 제거율, $H_2S$ 제거율, 소모동력 범위 등 플랜트 성능을 예측할 수 있다. Case Studies 결과를 활용하여 설계된 CCS 설비 용량이 운전범위에 적합한지를 판단할 수 있고 과잉 설계되었을 경우 플랜트 건설비를 절감할 수 있다. IGCC 가스화 플랜트에서 생산되는 합성가스의 $CO_2$ 분압, 목표 $CO_2$ 제거율, 경제성을 기준으로 적합한 CCS 공정을 판단한 결과 Selexol 공정이 선정되었다. Selexol 공정은 고압, 고농도의 산성가스 제거에 적합하며 다른 물리적 용매인 Rectisol 공정에 비해 건설비용이 경제적이고 화학 흡수제인 아민과 비교하여 운전 온도 범위가 넓다. CO, $H_2O$$CO_2$, $H_2$ 로 전환하는 Water Gas Shift Reaction (WGSR) 공정은 Co/Mo 촉매 반응기로 구성되었고 Selexol 공정은 $H_2S$ Absorber, $H_2S$ Stripper, $CO_2$ Absorber, $CO_2$ Flash Drum 로 구성되었다. WGSR+Selexol 모델링은 Wet Scrubber 후단의 합성가스 (40.5 bar, $136{\sim}139^{\circ}C$) 를 대상으로 하였다. WGSR+Selexol 공정 운전 조건 변화 [Process Design Case(PDC), Equipment Design Case(EDC), Turndown Design Case(TDC)] 에 따른 플랜트 모델링 결과를 비교분석 하였다. 주요 분석 내용은 WGSR 설비에서의 CO 의 $CO_2$ 전환 효율, Selexol 설비에서 $CO_2$ 제거 효율, $H_2S$ 제거 효율이다. 모델링 결과 WGSR 설비에서의 CO 의 $CO_2$ 로의 전환율 99.1% 이상, Selexol 설비에서 $CO_2$ 제거율은 91.6% 이상, $H_2S$ 제거율 100%이었다. CCS 설비 설치에 따른 플랜트 성능 영향을 분석하기 위해서 CCS 설비의 Chiller, Compressor, Pump 소비동력을 계산하였다. 모델링 결과 Chiller 는 2.6~8.5 MWth, Compressor 는 3.0~9.6 MWe, Pump 는 1.4~3.0 MWe 범위 이었다. 플랜트 로드가 50%인 TDC 소모동력은 플랜트 로드가 100%인 PDC 소모동력의 절반 수준이었다. 합성가스를 WGS+Selexol 공정을 통해 수소가스로 전환시키면 가스터빈 연료가스의 Lower Heating Value (LHV) 값이 평균 11.5% 감소하였다.

  • PDF

Characterization of Heavy Metals Including Mercury and Fine Particulate Emitted from a Circulating Fluidized Bed Power Plant Firing Anthracite Coals (무연탄 순환유동층 발전소로부터 배출되는 수은을 포함한 중금속 및 미세분진의 배출 특성)

  • Kim, Jeong-Hun;Yoo, Jong-Ik;Seo, Yong-Chil
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.268-274
    • /
    • 2010
  • Emission of heavy metals as hazardous air pollutants has been focused with tightening regulatory limits due to their hazardousness. Measurements and characteristic investigations of heavy metals emitted from a commercial power plant burning anthracite coal have been carried out. The plant consists of a circulating fluidized bed combustor, a cyclone, a boiler and an electrostatic precipitator(ESP) in series. Dust and gaseous samples were collected to measure main heavy metals including gaseous mercury before ESP and at stack. Dust emissions as total particulate matter (TPM), PM-10 and PM-2.5 at inlet of ESP were very high with 23,274, 9,555 and $7,790mg/Sm^3$, respectively, as expected, which is much higher than those from pulverized coal power plants. However TPM at stack was less than $0.16mg/Sm^3$, due to high dust removal efficiency by ESP. Similarly heavy metals emission showed high collection efficiency across ESP. From particle size distribution and metal enrichment in sizes, several metal concentrations could be correlated with particle size showing more enrichment in smaller particles. Mercury unlike other solid metals behaved differently by emitting as gaseous state due to high volatility. Removal of mercury was quite less than other metals due to it's volatility, which was 68% only. Across ESP, speciation change of mercury from elemental to oxidized was clearly shown so that elemental mercury was half of total mercury at stack unlike other coal power plants which equipped wet a scrubber.

Beneficiation of Low Grade Sericite Using Attrition Scrubbing and Sedimentation (해쇄 및 침강분리에 의한 저품위 견운모의 품위향상 특성)

  • Chae, Sungki;Kim, Hyunsoo;Kim, Sangbae;Kim, Wantae
    • Journal of the Mineralogical Society of Korea
    • /
    • v.30 no.4
    • /
    • pp.137-147
    • /
    • 2017
  • Sericite is a clay mineral that has a wide applications in the industry, depending on its purity. To maintain sericite's purity as high as possible it is necessary to remove its gangue minerals or control their contents prior to use for high value-added products and applications. In this study, the wet beneficiation of sericite by applying selective grinding and sedimentation techniques, were investigated. The ore mineral was composed mainly of sericite, quartz and calcite. Analysis showed that the content of sericite increased along with the particle size decrease, but the contents of impurity minerals as quartz and calcite were tended to decrease relatively with particle size decrease. The results of liberation tests using an attrition scrubber showed that the increase in residence time and slurry density have increased the generation of fine particles in -325 mesh size range. It was observed, however, that the contents of impurities such as quartz and calcite in such fine particles also increased during prolonged scrubbing. In the dispersed form without breaking, the yield of the recovered concentrate was 15.4 wt% and the $K_2O$ content was 9.84 wt%, after the dispersed slurry was allowed to settle for 20 minutes. On the other hand, the concentrate yield was increased to 23.4 wt% after 10 minute attrition scrubbing and 40 minute sedimentation, while its $K_2O$ content was decreased to 9.71 wt%. Most of final products were observed as platelet-shaped particles containing Si, Al and K which are main component of sericite.

A study on the Optimization of Activated carbon Adsorbent Preparation condition and Evaluation of Application Supporting of K-Fe-Li ternary metal ions for Improving Adsorption Capacity of Hydrogen Sulfide (H2S) (황화수소(H2S) 흡착성능 증진을 위한 K-Fe-Li 3원계 금속이온물질이 담지된 활성탄 흡착제 제조조건 최적화 및 적용성 평가 연구)

  • Choi, Sung Yeol;Han, Dong hee;Kim, Sung Su
    • Clean Technology
    • /
    • v.25 no.3
    • /
    • pp.189-197
    • /
    • 2019
  • In this study an optimization of the preparation conditions of activated carbon with a ternary metal ion material to treat $H_2S$, which is classified as a representative odor substance, was carried out. For a metal ion material for enhancing the adsorption performance of hydrogen sulfide, performance enhancement was confirmed by combining Li and Fe or a ternary combination (K, Li, Fe) based on KI, which is a substance promoting hydrogen sulfide adsorption performance. Also, it was determined by XRD analysis that the reaction of each active substance with $H_2S$ was because of binding. The adsorption performance increased more than 3 times with heat treatment of the adsorbent with nitrogen compared with heat treatment with air. The maximum adsorption constant ($q_m$) value of the optimum adsorbent was 97.07, which is 6 times higher than that of the existing K-based impregnated activated carbon. It was confirmed that the objective adsorption amount ($0.3g\;g^{-1}$) was secured by an equilibrium between the mass transfer rate and adsorption rate. From the results, it was confirmed that the performance improvement was noticeable even when activated carbon with a reagent grade activated carbon particle size was modified. It was confirmed that the adsorption performance exists at high relative humidity levels of 60 and 100%, and the optimized preparation can be applied to a wet process such as a scrubber downstream.

Identification of the Environmentally Problematic Input/Environmental Emissions and Selection of the Optimum End-of-pipe Treatment Technologies of the Cement Manufacturing Process (시멘트 제조공정의 환경적 취약 투입물/환경오염물 파악 및 최적종말처리 공정 선정)

  • Lee, Joo-Young;Kim, Yoon-Ha;Lee, Kun-Mo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.8
    • /
    • pp.449-455
    • /
    • 2017
  • Process input data including material and energy, process output data including product, co-product and its environmental emissions of the reference and target processes were collected and analyzed to evaluate the process performance. Environmentally problematic input/environmental emissions of the manufacturing processes were identified using these data. Significant process inputs contributing to each of the environmental emissions were identified using multiple regression analysis between the process inputs and environmental emissions. Optimum combination of the end-of-pipe technologies for treating the environmental emissions considering economic aspects was made using the linear programming technique. The cement manufacturing processes in Korea and the EU producing same type of cement were chosen for the case study. Environmentally problematic input/environmental emissions of the domestic cement manufacturing processes include coal, dust, and $SO_x$. Multiple regression analysis among the process inputs and environmental emissions revealed that $CO_2$ emission was influenced most by coal, followed by the input raw materials and gypsum. $SO_x$ emission was influenced by coal, and dust emission by gypsum followed by raw material. Optimization of the end-of-pipe technologies treating dust showed that a combination of 100% of the electro precipitator and 2.4% of the fiber filter gives the lowest cost. The $SO_x$ case showed that a combination of 100% of the dry addition process and 25.88% of the wet scrubber gives the lowest cost. Salient feature of this research is that it proposed a method for identifying environmentally problematic input/environmental emissions of the manufacturing processes, in particular, cement manufacturing process. Another feature is that it showed a method for selecting the optimum combination of the end-of-pipe treatment technologies.