• Title/Summary/Keyword: weight sensor

Search Result 577, Processing Time 0.029 seconds

Fundamental Research on the Measurement and Control System of Level Sensor for Launch Vehicle Propellant Tanks (발사체 추진제 탱크 수위 측정 및 제어 시스템 기초연구)

  • Shin, Dong-Sun;Han, Sang-Yeop;Cho, In-Hyun;Lee, Eung-Shin
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.393-396
    • /
    • 2008
  • Propellant consumption control for space launch vehicle can be achieved by propellant utilization system (PUS) and tank depletion system (TDS). In the course of developing new space launch vehicles, the main target of design is on reducing of space launch vehicle weight, which results in increasing both specific impulse and payload weight. The weights of space launch vehicles are generally allocated to structure, propulsion system, and propellants loaded. The quantity of propellants filled in propellant tanks may be estimated with the propellants actually consumed by propulsion system to complete its mission and the propellants left on-board at the time of engine shut-off. To minimize the remaining quantity of propellants on-board the supplying propellants' O/F ratio should be controlled from the certain time before engine shutdown. To control an O/F ratio, a control system, which accurately measures and compares the remainder of propellants in tanks and pipes, should be needed. This paper solely dedicates its contents to explore the merits and demerits of various level sensor, which is one of the important elements for PUS and TDS, and the transmission and control of signals within space launch vehicle.

  • PDF

Study on a method for correcting unbalanced sitting posture by force-sensing resistors (비균형적인 앉은자세 교정을 위한 힘-감지 저항센서 이용 연구)

  • Byun, Sang Pil;Jang, In Hyuk;Park, Ki Hyuk;Sohn, Ryang Hee;Lee, Won Gu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.4
    • /
    • pp.203-210
    • /
    • 2014
  • In this study, we present a method for correcting unbalanced sitting posture alignment to its optimal position, by designing a chair equipped with pressure sensor. With increasement in sedentary work, such as office work or study, people are now spending more time in chair. To accommodate sedentary life styles, many chairs are being designed for a comfortable sitting condition. However, without awareness and efforts for correct sitting posture, it may not be possible to achieve such condition. When the weight is not distributed evenly while sitting, it may cause various diseases such as scoliosis and a herniated disc. Being inspired by such facts, we have progressed basic researches to maintain the correct sitting posture. To demonstrate the proof-of-concept validation, we installed a series of sensors to a chair and then measured the changes in pressure distribution in various postures. The results show that this approach can be potentially helpful for understanding how fundamental problems due to unbalanced sitting posture can be corrected and maintained properly.

Sensor Data Allocation using Neural Network in Distributed-Gateway System (분산 게이트웨이 환경에서의 Neural Network를 이용한 센서 데이터 할당)

  • Lee, Tae-Ho;Kim, Dong-Hyun;Lee, Byung-Jun;Kim, Kyung-Tae;Youn, Hee-Yong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2018.07a
    • /
    • pp.39-40
    • /
    • 2018
  • 본 논문에서는 IIoT(Industrial IoT) 환경의 분산 게이트웨이 시스템(Distributed-gateway System)에서 하위의 수 천 개 이상의 센서로부터 데이터를 전송받는 각 게이트웨이의 작업부하(Workload)를 감소시키고 데이터 처리 속도를 향상시키기 위하여 신경망(Neural network) 알고리즘을 이용한 센서 데이터 할당 기법을 소개한다. 각 센서의 중요도에 따른 Weight와 측정 간격에 따른 Bias를 설정하고 학습과정을 통해 Output weight를 산출하여 데이터를 효율적으로 게이트웨이에 할당시킴으로써 신뢰성과 정확성, 신속성을 확보한다.

  • PDF

Multisensor Data Combination Using Fuzzy Weighted Average (퍼지 가중 평균을 이용한 다중 센서 데이타 융합)

  • Kim, Wan-Joo;Ko, Joong-Hyup;Chung, Myung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.383-386
    • /
    • 1993
  • In this paper, we propose a sensory data combination method by a fuzzy number approach for multisensor data fusion. Generally, the weighting of one sensory data with respect to another is derived from measures of the relative reliabilities of the two sensory modules. But the relative weight of two sensory data can be approximately determined through human experiences or insufficient experimental data without difficulty. We represent these relative weight using appropriate fuzzy numbers as well as sensory data itself. Using the relative weight, which is subjective valuation, and a fuzzy-numbered sensor data, the fuzzy weighted average method is used for a representative sensory data. The manipulation and calculation of fuzzy numbers can be carried out using the Zadeh's extension principle which can be approximately implemented by the $\alpha$-cut representation of fuzzy numbers and interval analysis.

  • PDF

Accuracy evaluation of diagnostic parameters estimated by uroflowmetry technique measuring hydraulic pressure (수압측정 방식의 요류검사 진단매개변수의 정확도 평가)

  • Kim, Kyung-Ah;Choi, Seong-Su;Kim, Sung-Sik;Kim, Kun-Jin;Park, Kyung-Soon;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.413-418
    • /
    • 2007
  • Uroflowmetry is of great convenience to diagnose benign prostate hypertrophy common in aged men. The urinary flow rate is obtained by weight measurement using load cell, however, sensitive to impact noise. An alternative technique was recently proposed to measure hydraulic pressure instead of weight and demonstrated to introduce significantly reduced noise. In this paper, we described the measured diagnostic parameters between the weight and pressure measuring techniques in 10 normal men. The weight and pressure signals were simultaneously acquired during urination, converted into urine volumes, then differentiated to obtain flow rate signals, which showed very similar waveforms. Diagnostic parameters evaluated by pressure measuring technique were well correlated with the standard weight measuring technique (correlation coefficient > 0.99). Therefore, the new uroflowmetry based on hydraulic pressure measurement can provide accurate diagnostic parameters, which would be clinically valid.

Implementation of Algorithm for home network during a bio-sensor system activities (생체 센서 시스템을 동작하는 동안 홈 네트워크 시스템의 알고리즘 구현)

  • Kim, Jeong-Lae;Kwon, Young-Man
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.31-37
    • /
    • 2010
  • This study was developed the home network system for the home stay care by bio-sensor system to translate the physical signal algorithm. The composition algorithm has five functions for a input function, frequency variable, displacement point input function, axial Variable, axial Sway Displacement to search a max and min point with adjustment of 0.01 unit in the reference level. There were checked physical condition of body balance to compounded a measurement such as a heart rate, temperature, weight. The algorithm of home network system can be used to support health care management system through health assistants in health care center and central health care system. It was expected to monitor a physical parameter for health management system.

Design and Implementation of a WiFi Trashcan based on Arduino (아두이노 기반 WiT(WiFi Trashcan)의 설계 및 구현)

  • Yoo, Jong-Yeol;Kim, Hyun-Il;Lee, Jang-Ho;Yang, Dong-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.11
    • /
    • pp.2143-2148
    • /
    • 2016
  • Recently due to development of IT technology, ideas and technology that blend with environment have evolved. This technology can help people's living environment and in the future it is an essential component of the connected society. In this paper, we propose WiT(WiFI Trashcan) which takes advantage of the IT technology fusion and environmental factors at the same time to create a more pleasant environment. WiT provides a free WiFi when trash is disposed in the trash can. WiT detects whether a user disposes trash, determines the volume of the trash and provides free WiFi. To detect trash we use ultrasonic sensor and trash weight is measured by using weight sensor. Also by using Phython programming the measured sensor value is transmitted to Raspberry Pie and WiFi delivery time is determined. We used Arduino and Raspberry Pi to design and implement WiT.

Design and Error Verification of Intravenous Injection Detection System that Combines Load Cell and Gyro Sensor (로드셀과 자이로센서를 융합한 수액 감지 시스템 설계 및 오차 검증)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.127-132
    • /
    • 2021
  • The intravenous injection monitoring system used by medical institutions was developed to remotely provide patients with the amount of intravenous injected and the termination point of the injection. In order to measure the amount of intravenous injection input, the weight or flow rate of the level going out from the inside to outside of the intravenous injection can be observed with a measuring sensor. The criteria for devices that apply herein are accuracy and vigilance. In addition, it is compact and should be easy to use when installing intravenous injection on patients. In medical institutions, the accuracy of the measured values must be high, and economically inexpensive devices are required. In this study, low-cost small-weight-centered load cell sensors were applied, and algorithms were applied to reduce the artefact by external movement by converging with gyro sensors for accuracy of measurements. As a result, it was possible to reduce the error of measurement, thereby improving the accuracy of the intravenous injection monitoring measurement value.

On-line Magnetic Resonance Quality Evaluation Sensor

  • Kim, Seong-Min;McCarthy, Michael J.;Chen, Pictiaw;Zion, Boaz
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.314-324
    • /
    • 1996
  • A high speed NMR quality evaluation sensor was designed , constructed and tested . The device consists of an NMR spectrometer coupled to a conveyor system. The conveyor was run at speeds ranging from 0 to 250 mm/s. Spectral of avocado fruits and one-dimensional magnetic resonance images of pickled olives were acquired while the samples were moving on a conveyor belt mounted through a 20Tesla NMR magnet with a 20 mm diameter surface coil and a 150 mm diameter imaging coil respectively. Fro a magnetic resonance spectrum analysis, motion through variations in the magnetic field tends to narrow spectral line width just like using sample rotation in high resolution NMR to narrow spectral line width. Spectrum analysis was used to detect the dry weight of avocado fruits using the ratio oil and water resonance peaks. Good correlations maximum r=0.970@ 50 mm/s and minimum r=0.894@250mm/s ) between oil and water resonance peak ratio and dry weight of avocados were observed at speeds ra ging from0 to 250mm/s. For the application of magnetic resonance imaging (MRI) method, the projections were used to distinguish between pitted and non-pitted olives . Effect of fruit position in the coil was tested and coil degree effects were noticed when projects were generated under dynamic conditions. Various belt speeds (up to 250mm/s) were tested and detection results were compared to static measurements. Higher classification errors were occurred at dynamic conditions compared to errors while olives were at rest.

  • PDF

Efficient Security Mechanism using Light-weight Data Origin Authentication in Sensor Networks (경량화 데이터 origin 인증을 통한 효율적인 센서 네트워크 보안에 관한 연구)

  • Park, Min-Ho;Lee, Chung-Keun;Son, Ju-Hyung;Seo, Seung-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.7A
    • /
    • pp.717-723
    • /
    • 2007
  • There are many weaknesses in sensor networks due to hardware limitation of sensor nodes besides the vulnerabilities of a wireless channel. In order to provide sensor networks with security, we should find out the approaches different from ones in existing wireless networks; the security mechanism in sensor network should be light-weighted and not degrade network performance. Sowe proposed a novel data origin authentication satisfying both of being light-weighted and maintaining network performance by using Unique Random Sequence Code. This scheme uses a challenge-response authentication consisting of a query code and a response code. In this paper, we show how to make a Unique Random Sequence Code and how to use it for data origin authentication.