Browse > Article

Implementation of Algorithm for home network during a bio-sensor system activities  

Kim, Jeong-Lae (을지대학교 보건과학대학 의료공학과)
Kwon, Young-Man (을지대학교 의료전산학부)
Publication Information
The Journal of the Institute of Internet, Broadcasting and Communication / v.10, no.5, 2010 , pp. 31-37 More about this Journal
Abstract
This study was developed the home network system for the home stay care by bio-sensor system to translate the physical signal algorithm. The composition algorithm has five functions for a input function, frequency variable, displacement point input function, axial Variable, axial Sway Displacement to search a max and min point with adjustment of 0.01 unit in the reference level. There were checked physical condition of body balance to compounded a measurement such as a heart rate, temperature, weight. The algorithm of home network system can be used to support health care management system through health assistants in health care center and central health care system. It was expected to monitor a physical parameter for health management system.
Keywords
Home Network Algorithm; Bio-sensor System; Body Balance; Physical Signal Monitoring;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Lai C.C., Lee R.G., Hsiao C.C., Liu H.S., Chen C.C., "A H-QoS-demand personalized home physiological monitoring system over a wireless multi-hop relay network for mobile home healthcare applications", J of Network and Computer Applications, Vol.32, pp.1229-1241, 2009.   DOI   ScienceOn
2 Alwan M, Mack DC, Dalal S, Kell S, Turner B, Felder RA, "Impact of passive in-home health status monitoring technology in home health: outcome pilot. In: Proceedings of the 1st distributed diagnosis and home healthcare (D2H2)conference." Arlington , VA, USA, 2-4 April, pp.79-82, 2006.
3 Bratan T, Clake M, Jones R, Larkworthy A, Paul R, "Evaluation of the practical feasibility and acceptability of home monitoring in residential homes." J Telemed Telecare, Vol.11(suppl.1), pp.29-31, 2005.   DOI
4 Korhonen I, Parkka J, Van Gils M., "Health monitoring in the home of the future." IEEE Eng Med Bio Mag, Vol.22(3), pp.266-73, 2003.
5 Pare G, Jaana M, Sicotte C, "Systematic review of home telemonitoring for chronic diseases: the evidence base." J Am Med Inf Assoc, Vol.14(3), pp.269-77, 2007.   DOI   ScienceOn
6 Naughton C, Bennett K, Feely J,"Prevalence of chronic disease in the elderly based on a national pharmacy claims database." Age Ageing, Vol.35(6), pp.633-6, 2006.   DOI   ScienceOn
7 Massion J., "Postural control system" Curr Opin Neurobiol Vol.4, pp.877-87, 1994.   DOI   ScienceOn
8 Koch S, "Heme telehealth-current state and future trends." Int J Med Inform, Vol.75(8), pp.565-76, 2006.   DOI   ScienceOn
9 Rigby M.,"Applying emergent ubiquitous technologies in health: the need to respond to new challenges of opportunity, expectation, and responsibility. Int J Med inform, Vol.76(suppl. 3), pp.349-52, 2007.   DOI
10 Lee R-G, Chen H-S, Lin C-C, Chang K-C, Chen J-H, "Home telecare system using cable television plants an experimental field trial." IEEE Trans Inform Technol Biomed, Vol.4(1), pp.37-44, 2000.   DOI   ScienceOn
11 Hernadez Al, Mora F, Villegas G, Passriello G, Carrault G, "Rea-time ECG transmission via Internet for nonclinical applications. IEEE Trans Inform Technol Biomed, Vol.5(3), pp.253-7, 2001.   DOI   ScienceOn
12 Anliker U, Ward JA, Lukowicz P, Troster G, Dolveck F, Baer M, et al., "AMON: a wearable multiparameter medical monitoring and alert system." IEEE Trans Inform Technol Biomed, Vol.8(4), pp.415-27, 2004.   DOI   ScienceOn
13 Lee R-G, Hsiao C-C, Chen C-C, Liu M-H, "A mobile-care system integrated with Bluetooth blood pressure and pulse monitor, and cellular phone." IEICE Trans Inform Syst, Vol.E89-D(5), pp.1702-11, 2006.   DOI   ScienceOn
14 Lin Y-H, Jan I-C, K0 PC-1, Chen Y-Y, Wong J-M, Jan G-J,"A wireless PDA-based physiological monitoring system for patient transport." IEEE Trans Inform Technol Biomed, Vol.8(4), pp.439-47, 2004.   DOI   ScienceOn
15 Lorincz K, Malan DJ, Fulford-Jones TRF, Nawoj A, Clavel A, Shnayder V, et al., "Sensor networks for emergency response: challenges and opportunites. IEEE Pervasive Comput, Vol.3(4), pp.16-23, 2004.   DOI   ScienceOn
16 Milenkovic A, Otto C, Jovanov E, "Wireless sensor networks for personal health monitoring: issues and an implementation." Comput Commun, Vol.29(13-14), pp.2531-33, 2006.
17 Bratan T, Clake M, Jones R, Larkworthy A, Paul R, "Evaluation of the practical feasibility and acceptability of home monitoring in residential homes." J Telemed Telecare, Vol.11(suppl.1), pp.29-31, 2005.   DOI
18 Stankovic JA, Cao Q, Doan T, Fang L, He Z, Kiran R, et al. "Wireless sensor networks for in-home healthcare: potential and challenges." In: Proceeding of the 2005 High Confidence Medical Device Software and Systems (HCMDSS) workshop, Philadelphia, PA, USA, 2-3 June 2005.
19 Lee R-G, Hsiao C-C, Chen C-C, Liu M-H, "A mobile-care system integrated with Bluetooth blood pressure and pulse monitor, and cellular phone." IEICE Trans Inform Syst, Vol.E89-D(5), pp.1702-11, 2006.   DOI   ScienceOn
20 Lee R-G, Chen K-C, Hsiao C-C, Tseng C-L, "A mobile care system with alert mechanism." IEEE Trans Inform Technol Biomed, Vol.11(5), pp.507-17, 2007.   DOI
21 Nicopolitidis P, Papadimitriou GI, Pomportsis AS,"Design alternatives for wireless local area networks," Int J Commun Syst, Vol.14(1), pp.1-42, 2001.   DOI   ScienceOn
22 Cohn H, Blatchly CA, Gombash LL. "A study of the clinical test of sensory interaction and balance". Phys Ther. 1993, 73, 346-354.   DOI
23 Shulmann DL, Goldfish E and Fisher AG. "Effect of movement on dynamic equilibrium". Phys Ther. 1987, 67, 1054-1057.   DOI
24 Fabio RPD. "Sensitivity and specificity of platform posturography for identifying patients with vestibular dysfunction". Phys Ther. 1995, 75, 290-305.   DOI
25 Shumway-Cook A and Horack FB. "Assessing the influence of sensory interaction on balance: Suggestion from field" Phys Ther. 1986, 66, 1548-1550.   DOI
26 Lorincz K, Malan DJ, Fulford-Jones TRF, Nawoj A, Clavel A, Shnayder V, et al., "Sensor networks for emergency response: challenges and opportunites. IEEE Pervasive Comput, Vol.3(4), pp.16-23, 2004.   DOI   ScienceOn