• Title/Summary/Keyword: weight of unit volume

Search Result 193, Processing Time 0.025 seconds

Cloning, expression, purification, and crystallization of Xoo0878, β-ketoacyl-acyl carrier protein synthase III (FabH), from Xanthomonas oryzae pv. oryzae

  • Ngo, Ho-Phuong-Thuy;Nguyen, Diem-Quynh;Kim, Seunghwan;Kim, Jeong-Gu;Ahn, Yeh-Jin;Kang, Lin-Woo
    • Biodesign
    • /
    • v.7 no.2
    • /
    • pp.35-37
    • /
    • 2019
  • Xanthomonas oryzae pv. oryzae (Xoo) is a plant pathogen, which causes a bacterial blight of rice. The bacterial blight is one of the most devastating diseases of rice in most of the rice growing countries and there is no effective pesticide against bacterial blight. The β-ketoacyl-acyl carrier protein synthase III (FabH) plays a key role in fatty acid synthesis (FAS) and is a promising drug target for the development of antibacterial agents. Xoo0878 gene, a fabH gene, from Xoo was cloned and its gene product Xoo0878 was expressed, purified and crystallized. Xoo0878 crystal diffracted to 2.1Å resolution and belonged to the triclinic space group P1, with unit-cell parameters a = 57.3Å, b = 64.7Å, c = 104.2Å and α = 81.6°, β = 84.7°, γ = 74.4°. There are four monomers in the asymmetric unit, with a corresponding crystal volume per protein weight of 2.65 Å3 Da-1 and a solvent content of 53.6%. Xoo0878 structure will be useful to develop new antibacterial agents against Xoo.

The Optimal Condenser Position & Capacity for Power Factor Compensation in Distribution System (배전계통의 역률보상 콘덴서의 최적 위치 및 용량 산정)

  • Jang, Jeong-Tae;Jeon Young-Soo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1190-1197
    • /
    • 1999
  • The management of power factor(PF) in the distribution line is treated according to the measurement a month about the feeder unit at the substation. In Korea, we have not researched into power factor in distribution system due to it's less weight. The reactive power in advanced countries is controlled automatically by the compensative condenser switch on/off under the monitoring. This paper first presents the optimal condenser position and proper capacity by lagrangue factor ${\lambda}_{Q}$ which is the line loss index about reactive power unit. Therefore, the largest ${\lambda}_{Q}$ node is the condenser injection point and we find out the best condenser capacity when the line loss is saturated by the moderation of condenser volume. By this method, we suggest 0.6% uprising PF by injection of 15 kVA condenser. Additionally, PF is analysed into 5 areas; large city, middle city, small city, farm village, fishing village by the use of Power Platform which is classified the same concept of the low load management in KEPCO. Two feeders of each area are selected by the worst results of PF in specified areas.

  • PDF

Inverse Correlation between Cancer Size and Abdominal Obesity in Colorectal Cancer Cases

  • Jeong, Taek Gun;Kim, Ji Wan;Lee, Sun-Young;Park, Hee Sun;Han, Hye Seung;Hwang, Dae Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.8
    • /
    • pp.4025-4030
    • /
    • 2016
  • Background: Correlation between colorectal cancer (CRC) and abdominal obesity has been established, but there is a paucity of data on non-obese CRC patients. The aim of this study was to establish the characteristics of CRCs that occur in such patients. Materials and Methods: Consecutive CRC patients without cachexia were included. Unintended body weight loss, T4- or M1-staged CRCs, extensive lymph node involvement, or synchronous malignancy were classified as cachectic conditions. Abdominal fat volumes were measured using a multidetector CT unit with a software (Rapidia, INFINITT, Seoul, Korea). Results: Of the newly-diagnosed CRC patients, 258 non-cachectic and 88 cachectic patients were analyzed. The cancer size (p<0.001) and T stage (p<0.001) were inversely correlated with body mass index (BMI), visceral fat and subcutaneous fat volumes. Cancer size was the only independent factor related to BMI (p=0.016), visceral fat volume (p=0.002), and subcutaneous fat volume (p=0.027). In non-cachectic patients, a significant inverse correlation was found only between the cancer size and visceral fat volume (p=0.017). Conclusions: Non-obese CRC patients tend to have larger CRC lesions than their obese counterparts even under non-cachectic conditions. Such an inverse correlation between cancer size and visceral fat volume suggests that considerable CRCs are not correlated with abdominal obesity.

Depth Map Estimation Model Using 3D Feature Volume (3차원 특징볼륨을 이용한 깊이영상 생성 모델)

  • Shin, Soo-Yeon;Kim, Dong-Myung;Suh, Jae-Won
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.447-454
    • /
    • 2018
  • This paper proposes a depth image generation algorithm of stereo images using a deep learning model composed of a CNN (convolutional neural network). The proposed algorithm consists of a feature extraction unit which extracts the main features of each parallax image and a depth learning unit which learns the parallax information using extracted features. First, the feature extraction unit extracts a feature map for each parallax image through the Xception module and the ASPP(Atrous spatial pyramid pooling) module, which are composed of 2D CNN layers. Then, the feature map for each parallax is accumulated in 3D form according to the time difference and the depth image is estimated after passing through the depth learning unit for learning the depth estimation weight through 3D CNN. The proposed algorithm estimates the depth of object region more accurately than other algorithms.

Effect of polypropylene and glass fiber on properties of lightweight concrete exposed to high temperature

  • Abdulnour Ali Jazem Ghanim;Mohamed Amin;Abdullah M. Zeyad;Bassam A. Tayeh;Ibrahim Saad Agwa;Yara Elsakhawy
    • Advances in concrete construction
    • /
    • v.15 no.3
    • /
    • pp.179-190
    • /
    • 2023
  • The effect of glass fibres (GF) and polypropylene fibres (PPF) on the fresh properties and mechanical properties of lightweight concrete (LWC) exposed to high temperatures is investigated in this study. In this study, fifteen LWC mixtures were carried out in three different groups reinforced with PPF or GF fibers by 0%, 0.2%, and 0.4% by volume of concrete. The first group included aluminum powder (AP) as an air agent at 0.03% with the normal weight coarse aggregate (NWCA) by 100% of the weight of coarse aggregate. In the second group, 33% of the NWCA weight was replaced by lightweight coarse aggregate (LWCA). In the third group, 67% of the NWCA weight was replaced by LWCA. The slump, unit weight, Compressive strength (CS), tensile strength (TS), and flexural strength (FS) were examined. For two hours, the CS and FS were subjected to elevated temperatures of 200℃, 400℃, and 600℃, in addition to microstructure analysis of concrete. In comparison to the reference mixture, the fresh properties and bulk density of LWC decreased with the use of the air agent or the replacement of 67% of the NWCA with LWCA. As a result of the fiber addition, both the slump test and the bulk density decreased. The addition of fibers increased the CS; the highest CS was 38.5 MPa when 0.4% GF was added, compared to 28.9 MPa for the reference mixture at the test age of 28 days. In addition, flexural and TS increased by 53% and 38%, respectively, for 0.4% GF mixes. As well as, adding 0.4% GF to LWC maintained a higher CS than other mixtures.

Emission Factor and Fuel Economy Calculation Using Vehicle Inspection and Maintenance Program (자동차 환경검사에 의한 대기오염물질 배출계수 및 연비 산출)

  • Lee, Tae-Woo;Keel, Ji-Hoon;Park, Jun-Hong;Eom, Myoung-Do;Kim, Jong-Choon;Lee, Dae-Yup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.5
    • /
    • pp.97-106
    • /
    • 2009
  • An objective of this study is to give practical information that could be used for calculating pollutant emission factors and fuel economy from Korean Inspection & Maintenance program, which has been using steady state acceleration simulation mode. Concentration results from I/M test is adequately converted to mass emission factors and fuel efficiency data, which have unit of g/km and km/L, respectively. Exhaust volume flow(EVF), which is for converting emission result from concentration to mass, is measured by tracer method in various vehicle speed - power condition. It is found that there is an apparent second order relationship between EVF and vehicle inertia weight. EVF is expressed in function of vehicle inertia weight in order to estimate EVF in I/M site without measuring device. Converted mass emission results from measured EVF and raw emission analyzer show a satisfactory agreement with those from conventional CVS-bag type measurement system. Mass emission factors and fuel efficiency from measured EVF and estimated EVF also show good agreement to each other. Considering that an I/M program has great advantages to recruit-based emission test in terms of the number of test vehicle, the information in this study can be used for developing an alternative procedure to collect more various data to establish national database of mobile emission factors and fuel economy, even though the driving cycle in I/M program is steady state cycle rather than transient cycle.

Chest Wall Reconstruction with a Transverse Rectus Abdominis Musculocutaneous Flap in an Extremely Oversized Heart Transplantation

  • Yim, Ji Hong;Eom, Jin Sup;Kim, Deok Yeol
    • Archives of Reconstructive Microsurgery
    • /
    • v.23 no.2
    • /
    • pp.89-92
    • /
    • 2014
  • An 8-year-old girl diagnosed with dilated cardiomyopathy and Russell-Silver syndrome was admitted to our pediatric intensive care unit due to low cardiac output and multiple-organ dysfunction. The patient was placed on the heart transplant waiting list and extracorporeal membrane oxygenation was performed as a bridge to transplantation. After 17 days, heart transplantation was performed. The donor was a 46-year-old female (weight, 50 kg; height, 150 cm). The donor:recipient weight ratio was 3.37:1. Because the dimension and volume of the recipient's thoracic cage were insufficient, the sternum could not be closed. Nine days after transplantation, the patient underwent delayed sternal closure. To obtain adequate space, we left the sternum 4.5 cm apart from each margin using four transverse titanium plates. A transverse rectus abdominis musculocutaneous flap was chosen to cover the wound. Due to the shortage of donors, a size-mismatched pediatric heart transplantation is sometimes unavoidable. Closure of the opened sternum of a transplant recipient can be challenging. Sternal reconstruction after an extremely oversized heart transplantation with transverse titanium plate fixation and a musculocutaneous flap can effectively achieve sternal closure and stability.

The mechanical properties of Reactive Powder Concrete using Ternary Pozzolanic Materials exposed to high Temperature (3성분계 포졸란재를 이용한 반응성 분체 콘크리트(RPC)의 고온특성)

  • Janchivdorj, Khulgadai;So, Hyoung-Seok;Yi, Je-Bang;So, Seung-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.68-71
    • /
    • 2013
  • Reactive Powder Concrete (RPC) is an ultra high strength and high ductility cement-based composite material and has shown some promise as a new generation concrete in construction field. It is characterized by a silica fume-cement mixture with very low water-binder (w/b) ratio and very dense microstructure, which is formed using various powders such as cement, silica fume and very fine quartz sand (0.15~0.4mm) instead of ordinary coarse aggregate. However, the unit weight of cement in RPC is as high as 900~1,000 kg/㎥ due to the use of very fine sand instead of coarse aggregate, and a large volume of relatively expensive silica fume as a high reactivity pozzolan is also used, which is not produced in Korea and thus must be imported. Since the density of RPC has a heavy weight at 2.5~3.0 g/㎤. In this study, the modified RPC was made by the combination of ternary pozzolanic materials such as blast furnace slag and fly ash, silica fume in order to economically and practically feasible for Korea's situation. The fire resistance and structural behavior of the modified RPC exposed to high temperature were investigated.

  • PDF

A Study on the Improvement of ripple factor tube voltage waveforms in inverter type X-ray generator (인버터식 X선장치의 관전압 맥동율 개선에 관한 연구)

  • 이성길;임홍우;조금배;정수복;백형래
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.234-238
    • /
    • 1999
  • In order to radiate X-ray, the low ripple stabilized high voltage DC over the range of 40KV to 150KV is directly inflicted to X-ray tube. The energy characteristics of the radiated X-ray depend on the pulsating waveforms of the DC voltage supplied X-ray tube. In general, the low ripple voltage waveforms with fast rising times are required to increase with the dosage per unit time lest the exposure time should be longer in orde that the motion artifacts of an object may be eliminated in actual. The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing new power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple, a high frequency PWM inverter is connected between DC source and high voltage transformer. This paper describes the output characteristics according to stabilize ripple of X-ray tube voltage and compared the reproducibility, direcibility and doesage.

  • PDF

Characteristic Evaluation of RDF for the Combined Drying Produced by Weight Mixing Ratio Use Chemical Wastewater Sludge and Anthracite Coal (화학폐수슬러지와 무연탄을 이용한 복합건조공정의 조사시간에 따른 고형연료의 특성 평가)

  • Lee, Seung-Chul;Jung, Jin-Hee;Lee, Jun-Hee
    • Journal of Environmental Science International
    • /
    • v.25 no.3
    • /
    • pp.417-424
    • /
    • 2016
  • The objective of this study was to evaluate the microwave drying characteristics of mixtures of chemical wastewater sludge (70~90%) and anthracite coal (10~30%) with respect to physical and economic factors such as mass, volume reduction, moisture content, drying rate and heating value when the wastes were dried at different weight mixing ratio and for different microwave irradiation time. The drying process were carried out in a microwave oven, the combined drying process with a 2,450 MHz frequency and 1 kW of power. Maximum dry rates per unit area on the microwave drying of mixtures with chemical wastewater sludge and anthracite coal were $35.5kg\;H_2O/m^2{\cdot}hr$ for Cs90-Ac10; $40.1kg\;H_2O/m^2{\cdot}hr$ for Cs80-Ac20 and $35.0kg\;H_2O/m^2{\cdot}hr$ for Cs70-Ac30. The result clearly indicated that moisture can be effectively and inexpensively removed from the wastes through use of the microwave drying process.