• Title/Summary/Keyword: weighing type

Search Result 121, Processing Time 0.034 seconds

A Paired Barrel Capable of Automatic Storage and Emptying of Water for a Weighing Raingauge (자동 저수와 배수가 가능한 중량 우량계 용 쌍수조)

  • Lim, Gyu-Ho;Lim, Eun Ok
    • Atmosphere
    • /
    • v.27 no.2
    • /
    • pp.251-258
    • /
    • 2017
  • The standard weighing raingauges have a capacity limit in measuring the amounts of precipitation. Exceptions are those using a siphon to drain the collected water during observations. To reduce the drain time of the siphon type or to overcome the hassles associated with the manual emptying of the bucket for measuring, the most of weighing gauges use a large bucket for storing of rainwater to be measured. To avoid the above-mentioned adverse requirements, we propose a paired barrel for a weighing raingauge. The paired barrel may improve the accuracy of the weighing raingauges by getting rid of their capacity limit and make the gauges smaller in size and lighter in weight than the conventional ones. We showed its proper function and the feasibility of realization by testing a prototype paired barrel.

Development of a Automated Noncontact Weighing System for Pigs (돼지의 자동 비접촉 체중계측 시스템 개발)

  • 임영일
    • Journal of Animal Environmental Science
    • /
    • v.6 no.1
    • /
    • pp.23-30
    • /
    • 2000
  • A automated noncontact weight system for pigs consisted of a CCD-type video camera and 10 photo sensors connected to a computer. In the experiment 20 pigs(Large Yorkshire $\times$ Landrace breed) weighing from 95kg to 115kg were used. Pig's original image data was transformed to a binary image an image excluding head and tail portion from the whole binary image and the area of pig was calculated. Then pig's volume was calculated by multiplying the area by the body hight measured with photo sensors. The correlation equation between the above volume(x) and pig's weight was y=0.0007 x -9.2152($R^2$=0.9965) Performance of a automated noncontact weighing system for pigs was tested with this equation. The results showed $\pm$0.65kg average error and 1.63kg maximum error. It was concluded that performance of a automated noncontact weighing system is excellent.

  • PDF

Development of Auto-Empting Type Weighing Precipitation Gauge and Performance Test on Rainfall Measurement (자동배수형 무게식 강수량계 개발 및 강우량 측정 성능검사)

  • Kim, Sang-Jo;Son, Top
    • Atmosphere
    • /
    • v.22 no.2
    • /
    • pp.279-285
    • /
    • 2012
  • The weighing precipitation gauge with auto-empting capability was developed in the R&D project organized by the Research Agency for Climate Science (RACS) and supported by the Korea Meteorological Administration (KMA). This project was initiated in line with the KMA's plan executed since 2010 to introduce the weighing precipitation gauges partly into of their Automatic Weather Station (AWS) network in order to upgrade the quality of precipitation data. The innovative feature of this research is that the auto-empting in weighing precipitation gauge is realized by abrupt rotation of receiving container. The prototype was tested in compliance with the relevant standards of KMA. The results of performance test on rainfall measurement in laboratory verified that the accuracies for 20 mm and 100 mm reference rainfall amount were 0.1 mm and 0.4 mm, respectively in both conditions of auto-empting and no-empting. During the rotation of container for auto-empting, the data was extrapolated smoothly by applying the same precipitation intensity of the previous 10 sec. Consequently, it was found that the auto-empting precipitation gauge developed in this research is quite enough to be used for the operational purpose of accurate measurement with 0.1 mm resolution, regardless of the precipitation intensity.

Growth and Yield of Double Cropping Potatoes Produced Using Seed Tubers of Different Types and Sizes

  • Park, Hyun Jin;Lee, Gyu Bin;Park, Young Eun;Cho, Ji Hong;Choi, Jang Gyu;Seo, Jin Hee;Cheon, Chung Gi;Chang, Dong Chil
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.66 no.4
    • /
    • pp.375-382
    • /
    • 2021
  • For stable cultivation in double cropping, it is important to use potato (Solanum tuberosum L.) cultivars with a short dormancy period of 50-70 days and plant seed tubers of appropriate type and size. An experiment was conducted during 2018-2019 to investigate the effects of seed tuber type and size on growth and yield performance in double cropping. Whole tubers of three sizes (10-20 g, 30-40 g, and 50-60 g) and conventional cut tubers weighing 30-40 g from three cultivars with different dormancy periods, namely 'Daeji' (40-60 days), 'Eunsun' (50-60 days), and 'Saebong' (50-80 days), were planted, and their field performance was compared. Regardless of the cultivar, the increase in the whole tuber weight up to 30-40 g led to fast emergence, thereby increasing ground cover rate, shoot growth rate, and tuber growth rate, which ultimately improved tuber yield by 33-54%. Comparing the whole and cut tubers, 'Daeji' and 'Eunsun' showed similar growth and yield performance; as such, the performance of whole tubers weighing 10-20 g was comparable to that of cut tubers weighing 30-40 g. However, 'Saebong', a cultivar with relatively long dormancy period, performed better with cut tuber than with whole tubers. Based on these results, we recommend the use of whole tubers weighing over 30 g for double cropping. Further studies to break tuber dormancy are warranted in cultivars with relatively long dormancy periods (50-80 days), such as 'Saebong'.

Development of Rice Yield Prediction System of Head-Feed Type Combine Harvester (자탈형 콤바인의 실시간 벼 수확량 예측 시스템 개발)

  • Sang Hee Lee;So Young Shin;Deok Gyu Choi;Won-Kyung Kim;Seok Pyo Moon;Chang Uk Cheon;Seok Ho Park;Youn Koo Kang;Sung Hyuk Jang
    • Journal of Drive and Control
    • /
    • v.21 no.2
    • /
    • pp.36-43
    • /
    • 2024
  • The yield is basic and necessary information in precision agriculture that reduces input resources and enhances productivity. Yield information is important because it can be used to set up farming plans and evaluate farming results. Yield monitoring systems are commercialized in the United States and Japan but not in Korea. Therefore, such a system must be developed. This study was conducted to develop a yield monitoring system that improved performance by correcting a previously developed flow sensor using a grain tank-weighing system. An impact-plated type flow sensor was installed in a grain tank where grains are placed, and grain tank-weighing sensors were installed under the grain tank to estimate the weight of the grain inside the tank. The grain flow rate and grain weight prediction models showed high correlations, with coefficient of determinations (R2) of 0.9979 and 0.9991, respectively. A main controller of the yield monitoring system that calculated the real-time yield using a sensor output value was also developed and installed in a combine harvester. Field tests of the combine harvester yield monitoring system were conducted in a rice paddy field. The developed yield monitoring system showed high accuracy with an error of 0.13%. Therefore, the newly developed yield monitoring system can be used to predict grain weight with high accuracy.

Overloading Control Effectiveness of Overweight Enforcement System using High-Speed Weigh-In-Motion (고속축중기를 활용한 과적단속시스템의 과적 억제효과 분석)

  • Kwon, Soon-Min;Jung, Young-Yoon;Lee, Kyung-Bae
    • International Journal of Highway Engineering
    • /
    • v.14 no.5
    • /
    • pp.179-188
    • /
    • 2012
  • PURPOSES: The aim of this study is to analyze overloading control effectiveness of enforcing overweighted vehicles using HS-WIM (High-Speed Weigh-in-Motion) at main lane of expressway. METHODS: To analyze the weight distribution statistically, HS-WIM system should has an appropriate weighing accuracy. Thus, the weighing accuracy of the two HS-WIM systems was estimated by applying European specifications and ASTM (American Standards for Testing and Materials) for WIM in this study. Based on the results of accuracy test, overweight enforcement system has been operated at main lanes of two expressway routes in order to provide weight informations of overweighted vehicle in real time for enforcement squad. To evaluate the overloading control effectiveness with enforcement, traffic volume and axle loads of trucks for two months at the right after beginning of the enforcement were compared with data set for same periods before the enforcement. RESULTS: As the results of weighing accuracy test, both WIM systems were accepted to the most precise type that can be useful to applicate not only statistical purpose but enforcing on overweight vehicles directly. After the enforcement, the rate of overweighted trucks that weighed over enforcement limits had been decreased by 27% compared with the rate before the enforcement. Especially, the rate of overweighted trucks that weighed over 48 tons had been decreased by 91%. On the other hand, in counterpoint to decrease of the overweighted vehicle, the rate of trucks that weighed under enforcement limits had been increased by 7%. CONCLUSIONS: From the results, it is quite clear that overloading has been controlled since the beginning of the enforcement.

Uncertainty Evaluation of Ammonia Determination in Burley Tobacco (버어리종 담배중 암모니아성 질소에 대한 불확도 측정)

  • Lee Jeong-Min;Lee Kyoung-Ku;Han Sang-Bin
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.27 no.1 s.53
    • /
    • pp.107-114
    • /
    • 2005
  • The uncertainty of measurement in quantitative analysis of ammonia by continuous-flow analysis method was evaluated following internationally accepted guidelines. The sources of uncertainty associated with the analysis of ammonia were the weighing of sample, the preparation of extracting solution, the addition of extracting solution into the sample, the reproducibility of analysis and the determination of water content in tobacco, etc. In calculating uncertainties, Type A of uncertainty was evaluated by the statistical analysis of a series of observation, and Type B by the information based on supplier's catalogue and/or certificated of calibration. It was shown that the main source of uncertainty was caused by the volume measurement of 1 mL and 2 mL, the purity of ammonia reference material in the preparation of standard solution, the reproducibility of analysis and the determination of water content of tobacco. The uncertainty in the addition of extraction solution, the sample weighing, the volume measurement of 50 mL and 100 mL, and the calibration curve of standard solution contributed relatively little to the overall uncertainty. The expanded uncertainty of ammonia determination in burley tobacco at $95\%$ level of confidence was $0.00997\%$.

Uncertainty in Determination of Menthol from Mentholated Cigarette (담배 중 멘톨 분석에 대한 불확도 측정)

  • 장기철;이운철;백순옥;한상빈
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.22 no.1
    • /
    • pp.91-98
    • /
    • 2000
  • This study was carried out to evaluate the uncertainty in the analysis of menthol content from the mentholated cigarette. Menthol in the sample cigarette was extracted with methanol containing an anethole as an internal standard, and then analyzed by gas chromatography. As the sources of uncertainty associated with the analysis of menthol, were the following points tested, such as the weighing of sample, the preparation of extracting solution, the pipetting of extracting solution into the sample, the preparation of standard solution, the precision of GC injections for standard & sample solution, the GC response factor of standard solution, the reproducibility of menthol analysis, and the determination of water content in tobacco, etc. For calculating the uncertainties, type A of uncertainty was evaluated by the statistical analysis of a series of observation, and type B by the information based on supplier's catalogue and/or certificated of calibration. Sources of uncertainty were subsequently included and mathematically combined with the uncertainty arising from the assessment of accuracy to provide the overall uncertainty. It was shown that the main source of uncertainty came from the errors in the reproducibility of menthol and water determination, the purity of menthol reference material in the preparation of standard solution, and the precision of GC injections for sample solution. The errors in sample weighing and volume measurement contributed relatively little to the overall uncertainty. The expanded uncertainty in the mentholated cigarettes, Korean and American brand, at 0.95 level of statistical confidence was $\pm$0.06 and $\pm$0.07 mg/g for a menthol content of 1.89 and 2.32 mg/g, respectively.

  • PDF

Uncertainty of Total Alkaloids and Reducing Sugar Determination in Flue-cured Tobacco (황색종 담배중 전알카로이드와 환원당 분석에 대한 불확도 측정)

  • 백순옥;장기철;이운철;한상빈
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.23 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • This study was carried out to evaluate the uncertainty in the analysis of total alkaloids and reducing sugar content in flue-cured tobacco. The sources of uncertainty associated with the analysis of total alkaloids and reducing sugar were the weighing of sample, the preparation of extracting solution, the addition of extracting solution into the sample, the preparation of standard solution, the precision of calibration curve for standard solution, the reproducibility of analysis, and the determination of water content in tobacco, etc. For the calculating uncertainties, Type A of uncertainty was evaluated by the statistical analysis of a series of observation, and Type B by the information based on supplier’s catalogue and/or certificated of calibration. It was shown that the main source of uncertainty was caused by the calibration curve of standard solution, the reproducibility of analysis, the volume measurement of 1$m\ell$, and the purity of nicotine reference material in the preparation of standard solution. The uncertainty in the addition of extracting solution, the sample weighing, the volume measurement of 100$m\ell$, and the determination of water content of tobacco contributed relatively little to the overall uncertainty. The expanded uncertainty of total alkaloids and reducing sugar in flue-cured tobacco at 95% level of confidence was $\pm$0.12% and $\pm$0.54%, respectively.

  • PDF

FORMATION OF EXTRACELLULAR MATRIX COMPONENTS DURING DEVELOPMENT AND REPAIR OF PERFORATION OF THE RAT DENTIN AND PULP (흰쥐 대구치의 치수강 노출 후 치유 및 형성과정에서 치수와 상아질 기질내의 교원질과 당단백의 분포에 관한 면역조직화학적 연구)

  • Kim, Byung-Wooh;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.35-53
    • /
    • 1996
  • The development and repair requires the formation of new tissues comprised of various extracellular matrix components. The present study investigated the formation and distribution of the major ECM components such as type I collagen, type III collagen, fibronection, bone sialoprotein, and osteonection during development and repair. For developing observation. Sprague-Dawley rats weighing $27{\pm}1gm$ were sacrificed. For repair observation, Sprague-Dawley rats weighing $110{\pm}5gm$ were used. The pulp perforation were prepared on mesial surface of the maxillary first molar by using 1/2round bur. At 5 days after perforation, rats were sacrificed by perfusion with 3 % paroformaldehyde. The maxillary first molar region were cut, demineralized, dehydrated and embedded in paraffin. Immunostaining the ECM components was achieved by the avidin-biotin complex method. The results as follows : 1. Bright immunoreaction for fibronectin was present in the basement membrane at the inner epithelial-mesenchymal interface, especially concentrated in the blood vessel walls, cell membrane of odontoblasts, and initial predentin. 2. Type I and III collagen was observed in the newly formed pulp tissue, predentin, and its intensity increased as more of these components during repair. 3. Strong immunostaining for bone sialoprotein and osteonectin was found in dentin while no or weaker staining was observed loose connective tissue of the pulp. 4. These results suggest that develpment and repair is achieved through a series of cell differentiation and attachment by the specific ECM components.

  • PDF