• Title/Summary/Keyword: weighing design

Search Result 102, Processing Time 0.028 seconds

A-OPTIMAL CHEMICAL BALANCE WEIGHING DESIGN WITH CORRELATED ERRORS

  • Ceranka, Bronislaw;Graczyk, Malgorzata
    • Journal of applied mathematics & informatics
    • /
    • v.16 no.1_2
    • /
    • pp.143-150
    • /
    • 2004
  • In this paper we study the estimation problem of individual weights of objects using an A-optimal chemical balance weighing design. We assume that in this model errors are correlated and they have the same variances. The lower bound of tr$(X'G^{-1}X)^{-1}$ is obtained and a necessary and sufficient condition for this lower bound to be attained is given. There is given new construction method of A-optimal chemical balance weighing design.

A study on the development of dynamic weighing measurement system (동하중 측정 신호처리의 개발에 관한 연구)

  • Park, Chan-Won;Shin, Hyoung-Jae;Lee, Young-Jun;Shin, Young-kyun;Ann, Kwang-Hee
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.173-180
    • /
    • 1998
  • A high speed and stable A/D conversion data process is required to weigh a mass on moving conveyer weighing platter. The paper presents a new method to obtain stable and fast automatic weighing A/D conversion data process. Dynamic weighting system which is constructed with dual load cell is realized by the stable A/D conversion data process algorithm using DSP. The proposed method is applied to the real design, and that experimental results showed good performances of the weighing stability.

  • PDF

Mechanism Design of the Micro Weighing Device by Using Null Balance Method (영위법을 이용한 미소중량 측정 장치의 기구설계)

  • Choi, In-Mook;Woo, Sam-Yong;Kim, Boo-Shik;Kim, Soo-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.183-193
    • /
    • 2003
  • Micro-weighing device by using null balance method is being essential part in fields of high-technology industries such as precision semiconductor industry, precision chemistry, biotechnology and genetics etc. Also, requirements for high resolution and for large measurement range increase more and more. The performance of the micro-weighing device can be determined by the mechanism design and analysis. The analytical design method has been proposed for the performance improvement such as resolution, measurement range and fast response. The 2-stage displacement amplification is designed to overcome the limit of conventional force transmitting lever. The parallel spring is designed for the measurement result independent of the input force position variation. Also, the natural frequency of mechanism is analyzed for the fast response. After each analysis, optimal design has been carried out. To verify the analysis and design result, characteristics experiments had been carried out after construction. Finally, the system had been controlled.

Obtaining Design Characteristics of Lever-linked Roberval Mechanism through Weighing Method (무게측정방식에 따른 Lever-linked Roberval Mechanism의 설계특성)

  • An, Ji Yun;Ahn, Jung Hwan;Lee, Gil Seung;Kim, Hwa Young
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.336-341
    • /
    • 2020
  • The deflection and null balance methods are used for precision force measurement in the precision industry. Since both methods are based on deformation, the performance of the load cell mechanism is important. In this study, the design variables were obtained via the free body diagram of a lever-linked Roberval mechanism (combined with a flexible hinge link and a Roberval mechanism), and the design characteristics were analyzed according to the weight method. Based on the design characteristics, the optimal design was conducted according to the weight method and FEM was used to verify its reliability.

The Design Method and Error Analysis of Machine Electronic Weighing Burden System controlled by a Computer Automatically

  • Zhang, Zhengou;Lin, Shanling
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.768-778
    • /
    • 1993
  • The system is designed for the production and processing of feed, fertilizer, sugar , and grain. It can be used to weigh and transport automatically their pellet, power or nonstickness materials. In this system, we use discontinuous totalising automatic weighing instruments to weigh materials. It is a closed-cycle control system controlled by industrial controlling computer STD bus. The system used for processing grain and feed can improve the quality of products , carry out scientific management, increase productivity and decrease the intensity of labour

  • PDF

Development of WIM System Using Digital Loadcell (디지털 로드셀을 이용한 WIM 시스템의 개발)

  • Park, Chan-Won;Jeon, Chan-Min;Park, Heung-Joon
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.55-61
    • /
    • 2003
  • In this study, a signal processing and related techniques for development of a weight measuring system using a digital loadcell which is able to satisfy the important properties of WIM (weighing-in-motion) system have been investigated. A fast and high accurate signal processing of the digital load cell sensor for weighing-in-motion system is presented. A/D conversion system is constructed to realize a stable A/D conversion and signal processing algorithm using DSP and microprocessor. A new technique for vibration and measuring speed of the system is also investigated. The proposed method was applied to the actual design and the experimental results showed good performance of the weighing speed and stability.

  • PDF

Quality Assessment of Domestic Non-automatic Weighing Instruments for International Standards (국제표준에 대비한 국내 비자동저울의 품질평가에 관한 연구)

  • Namkoong Chai-Kwan;Kong Jae Hyang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.127-134
    • /
    • 2004
  • As the result of reduction of the barrier of national economy on matters of quality assurance of weighing instruments in recently, it is considering in domestic as well as international matters. Therefore, this study is to analysis and compare with international md national measuring standards on the electric self-indicating scale, to improve the quality of electronic machine by providing a reformation plan on currently problems of domestic manufactured, and to identify to introduce in domestic criteria from international standards. I had compared KSC 1313 to OIML R 76-1 as the performance assessment items, such as metrology Properties test, static temperature test, temperature effect testing under the un-load, electronic wave disturbance test, high-tempereature and high-humidity stability test and durability test. Therefore, only one company is passed all items of the test according to the international (reference) standards, but it is possible to improve the quality in general if it should be use the load cell and electric components which is stability of temperature change in order to supplementation to the static temperature test and temperature effect testing under the un-load. It is also possible to apply in the domestic with the OIML 76-1 after correcting the design.

Structural live load surveys by deep learning

  • Li, Yang;Chen, Jun
    • Smart Structures and Systems
    • /
    • v.30 no.2
    • /
    • pp.145-157
    • /
    • 2022
  • The design of safe and economical structures depends on the reliable live load from load survey. Live load surveys are traditionally conducted by randomly selecting rooms and weighing each item on-site, a method that has problems of low efficiency, high cost, and long cycle time. This paper proposes a deep learning-based method combined with Internet big data to perform live load surveys. The proposed survey method utilizes multi-source heterogeneous data, such as images, voice, and product identification, to obtain the live load without weighing each item through object detection, web crawler, and speech recognition. The indoor objects and face detection models are first developed based on fine-tuning the YOLOv3 algorithm to detect target objects and obtain the number of people in a room, respectively. Each detection model is evaluated using the independent testing set. Then web crawler frameworks with keyword and image retrieval are established to extract the weight information of detected objects from Internet big data. The live load in a room is derived by combining the weight and number of items and people. To verify the feasibility of the proposed survey method, a live load survey is carried out for a meeting room. The results show that, compared with the traditional method of sampling and weighing, the proposed method could perform efficient and convenient live load surveys and represents a new load research paradigm.

Parallelism Error Compensation for Force Measurement by Electromagnetic Compensation (전자기력 보상방식의 힘 측정을 위한 평행도 오차 보상)

  • 최인묵;우삼용;김부식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1051-1054
    • /
    • 2003
  • For micro-weighing, null balance method is widely used in the precision industrial fields, such as biomedicine, semiconductor, chemistry and so on. In order to obtain high resolution and large measurement range simultaneously, the mechanism should be analyzed and optimized. However, large measurement error can be generated according to the mass loading position and this error is called as a corner loading error. The corner loading error is caused by the parallelism error of a Roberval mechanism used to minimize it. The corner loading error is one of the most dominant error sources that should be removed. It is possible to design that the mechanism has no corner loading error theoretically, but the mechanism of the micro weighing device is very difficult to be realized as original design due to assembling and manufacturing error. For the required specification of the device, the precise manufacturing technique under a few $\mu\textrm{m}$ is required for the realization of the design. In this paper, the effects of the parallelism error are analyzed by using Lagrange method and verified by experiment. Also, the compensation mechanism is proposed and the corner loading error is reduced by restoring tile parallelism.

  • PDF