Research on Separation Behavior Joint of Develop and Application in Sheet-Membrane Composite Waterproofing (시트-도막을 이용한 분리거동형 복합방수공법 개발 및 적용에 관한 연구)

  • Heo, Neung-Hoe;Kim, Dong-Bum;Oh, Je-Gon;Go, Gun-Woong;Go, Jang-Ryeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.165-166
    • /
    • 2014
  • The Composite waterproofing began to rise gradually 2000s in domestic. However, the sheet-membrane composite waterproofing method also acts as an abutment vulnerability that was a problem in a single method, and had the problem of damage to the formation of leakage paths. The existing non-overlap method, through vigorous research abutting sheet shall or could be developed to improve the seal performance of this method with the I-type joint coating material. Nevertheless, it has an integral top coat paint membrane and a sheet abutment limitation, damage to the upper membrane is damaged junction coating membranes has been generated. In this study, a method that has a layer of insulation on the joint bond breaker concept development, and to determine the physical properties with insulated joints to determine the breaking off of the upper joint is damaged coating membrane and tensile performance.

  • PDF

Life cycle assessment (LCA) of roof-waterproofing systems for reinforced concrete building

  • Ji, Sukwon;Kyung, Daeseung;Lee, Woojin
    • Advances in environmental research
    • /
    • v.3 no.4
    • /
    • pp.367-377
    • /
    • 2014
  • In this study, we investigated a life cycle assessment (LCA) of six roof-waterproofing systems [asphalt (C1), synthetic polymer-based sheet (C2), improved asphalt (C3), liquid applied membrane (C4), Metal sheet with asphalt sheet (N1), and liquid applied membrane with asphalt sheet (N2)]for reinforced concrete building using an architectural model. To acquire accurate and realistic LCA results, minimum units of material compositions for life cycle inventory and real data for compositions of waterproofing materials were used. Considering only materials and energy demands for waterproofing systems per square meter, higher greenhouse gas (GHG) emissions could be generated in the order of C1 > N2 > C4 > N1 > C2 > C3 during construction phase. However, the order was changed to C1 > C4 > C3 > N2 > N1 > C2, when the actual architecture model was applied to the roof based on each specifications. When an entire life cycle including construction, maintenance, and deconstruction were considered, the amount of GHG emission was in the order of C4 > C1 > C3 > N2 > C2 > N1. Consequently, N1 was the most environmental-friendly waterproofing system producing the lowest GHG emission. GHG emissions from maintenance phase accounted for 71.4%~78.3% among whole life cycle.

A study on a performance the appliable rubber asphalt of monolithic waterproofing material of construction quality and the cement polymer modified waterproof coating membrane material of surface treatment. (무기질계 탄성 도막재와 고무 아스팔트를 적층한 일체형 방수재의 시공특성에 관한 실험적 연구)

  • Park Jin-Sang;Choi Sung-Min;Park Young-Tea;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.223-226
    • /
    • 2005
  • In this study on the appliable Asphalt sheet of monolithic and inorganic matter waterproofing ,Fing material using of field because of problem of complex waterproofing sheet. Before this cement polymer modified waterproof coating and appliable asphalt sheet of monolithic whether have stability by method of construction about all style waterproofing that evaluate to new method of construction development naturally big emphasis put and try to approach. Did performance test item first at, as a result, drew by suitable thing in all KS items. This is considered to have more effective spot construction work because if means that have stability by material as well as method of construction.

  • PDF

An Experimental Study on the Outside Waterproofing Construction Method of Underground Structures Using the High-Adhesion and High-Elasticity of Unvulcanized Sheet (비가황 고점착.고탄성의 균질시트를 이용한 지하 외방수공법에 관한 실험적 연구)

  • Shao, Xu-Dong;Kim, Seon-Hwa;Kwon, Ki-Joo;Kwak, Kyu-Sung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.225-229
    • /
    • 2009
  • It has been found that existing detects at the junction between waterproofing layer as well as the material and the surfaces of the construction when waterproofing sheet is employed in the currently used unground structures waterproofing technology, causing a series of problems such as the high cost to the maintenance for leakage and the durability. The purpose of this study is about reducing the waterpoofing defects in underground structures. consequently, the homogeneous sheet which has some quality such as the unvulcanizate, high-adhesion and high-elastic was examined on physical properties. As a test result, it was confirmed to have satisfied performance about the ks. However, it must be continued to study through mock-up test for confirming of site application.

  • PDF

A Study on Performance Standards of Quality Improvements of Self-adhesive Waterproofing Sheets by Materials (계열별 자착형 방수시트의 성능 품질기준 개선안에 관한 연구)

  • Park, Jin-Sang;Jeon, Jong-Su;Song, Je-Young;Bae, Kee-Sun;Oh, Sang-keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.303-304
    • /
    • 2013
  • The field application through the quality control of self adhesive rubberized asphalt waterproofing sheet was regulated by KS F 4934 of Korea Standard in 2003. However, the regulations that the different material properties of self-Adhesive waterproofing sheets are difficult to quality control on the standard. Therefore, this research was performed for of quality control all affiliations of self-adhesive waterproofing sheet through basic properties test and proposed quality standard revised bill in KS F 4934.

  • PDF

The Automatic equipments Non-Exposure waterproofing method of reduced construction hours integrated with the improved URE-Sheet and UREPALT adhesives (우레팔트 접착제를 사용한 개량형 우레시트 일체식 공기단축형 기계화 시공 비노출 방수공법)

  • Min, Sung-Woo;Oh, Chang-Won;Yang, Jae-Bong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05c
    • /
    • pp.135-141
    • /
    • 2009
  • This technology is able to construct with hardening UREPALT adhesives and TPO URE-Sheet simultaneously using automatic equipments. the benefit of this construction method is that The layer of waterproofing is uniform and defect of construction would be reduced because of no construction joints between UREPALT adhesives and TPO URE-Sheet. Furthermore, this new method could accomplish shortening of construction period, quality control and saving of labor costs. Also the non-exposure waterproofing method would be protected from fire and safe for workers without using a torch.

  • PDF

Development and Application of Unit Table Form using Euro Form for High-rise Building Construction (연질 및 경질 초속경도막방수재를 복합화한 옥상노출방수공법에 관한 실험적 연구(구조물 거동 대응성))

  • Choi, Eun-Kyu;Seo, Hyun-Jae;Kim, Bum-Soo;Lee, Jung-Hun;Song, Je-Young;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.141-142
    • /
    • 2017
  • New waterproofing technologies have emerged in the field of building waterproofing due to the recent diversification of the size and type of structures, the enhancement of required performance, and the diversification of new technologies (such as materials and methods)(Sheet waterproofing material, coating waterproofing material) is reduced, and composite waterproofing materials that utilize mutual benefits are widely used by compounding them (sheet+coating film, coating film+sheet). However, it is true that there is no evaluation method that can verify these composite waterproof materials, which is the most widely used at present, but the KS standard only specifies tests for individual materials However, there is a situation in which the countermeasures without a test method for composite waterproofing become sudden.

  • PDF

A Study on Absorption Amount of Water-Repellency Processed Non-Woven Fabric in PVC Composite Waterproofing Sheet of A Multi-Layer Structure (다층막 구조형 PVC 복합방수시트 내 발수 처리된 부직포의 흡수량에 관한 연구)

  • An, Ki-Won;Heo, Neung-Hoe;Oh, Je-Gon;Go, Gun-Woong;Go, Jang-Ryeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.163-164
    • /
    • 2014
  • This study is conducted for prevent spread of penetration water and water leakage through non-woven fabric between PVC sheet and PVC sheet in the PVC composite waterproofing sheet of a multi-layer structure. For this, carry out absorption amount test to confirm spread resistance performance after manufacturing PVC composite waterproofing sheet of a multi-layer structure using water-repellency processed non-woven fabric. As a result of test, weight of water-repellency processed non-woven fabric increased to 1.178g, Compared with beginning and there are not penetration water.

  • PDF

A study on the proposal of test condition for apartment bathroom dry waterproofing method for synthetic polymer based waterproof sheet (EPDM) (공동주택 욕실 건식방수공법의 성능시험조건 제안 연구 - 합성 고분자계 방수 시트(EPDM)를 대상으로 -)

  • Seo, Hyun-Jae;Lee, Jung-Hun;Song, Young-Chan;Kim, Yong-Ro;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.281-282
    • /
    • 2018
  • Recently, apartment houses are becoming more and more sophisticated and attention has been focused on the design of the interior of the bathrooms. As bathrooms always use water, the importance of waterproofing is very high. However, there continues to use the method that was used 30 years ago. And no one was trying to improve. It is necessary to be converted to a dry method, because waterproofing methods and materials have developed. Therefore, this study proposes the required performance before applying the dry waterproofing material to bathroom.

  • PDF

Waterproofing Materials According to the External Environment of Non-exposed Waterproofing Materials for Underground Structures Performance Change Requirement (지하 구조물용 비노출형 방수재의 외부환경에 따른 방수재의 성능 변화 요구)

  • Jung, Suk-Joo;Song, Je-Young;Won, Seong-Jae;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.85-86
    • /
    • 2020
  • In securing durability of underground structure non-exposed waterproof materials, the company aims to improve durability of waterproof materials by studying more realistic weather conditions than KS standards and developers' durability standards. Analyzing the actual climate data in Korea and the temperature of the basement layer, it is a waterproofing sheet method, a self-adhesive sheet method in which a film and a compound, which are currently widely used as underground water-proofing, and a self-adhesive waterproofing sheet method, etc. We would like to present the guidelines necessary to prevent the temperature situation and waterproof defects that are ideal for setting the endurance conditions later.