• Title/Summary/Keyword: waterproofing leakage

Search Result 83, Processing Time 0.022 seconds

Leakage Situation and Main Leakage Areas of Domestic Residential Building Underground Parking Lots (국내 공동주택 지하주차장의 누수 실태 및 주요 누수 부위 조사)

  • Lee, Jung-Hun;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.496-503
    • /
    • 2016
  • This paper studies the leakage situation of domestic residential building underground parking lots and main leakage areas. 18 complexes were studied and the results showed that 80% of buildings with exterior waterproofing had no leakage, but all buildings with interior waterproofing had leakage. According to a survey among professionals, water leakage problems are considered to be severe in underground parking lots and a preventative measure is required by the government. By comparing the survey and the actual situation at hand, the results showed that the lowest floor slab, wall construction joints, and floor expansion joints were the most prone to leakage. Based on the results, further study to develop a design manual for the appropriate prevention of leakage is deemed necessary.

An experimental study about the water leakage structure of waterproofing layer performance demobilization method using of stick expansion type complex of flexible material (점착$\cdot$팽창성 유연형 복합소재를 이용한 누수구조물의 방수층 성능복원공법에 관한 실험적 연구)

  • Jang Hyok-Soo;Kang Hyo-Jin;Song Je-Young;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.79-83
    • /
    • 2005
  • In the reinforced concrete structure, Even if speak that water leakage occurrence is no problem to material, there is a lot of reasons construction factor, material damage by behavior structure, properties of matter change by years and water leakage part by environment condition. so, waterproofing technological consideration should be gone ahead. In this research, we will study about stick performance, concrete surface adhesive, damage and blow. we will check all things and test it. The stick expansion type complex of flexible material passed on result of standard. It is conducive to concrete of durability by waterproofing layer performance demobilitation technology on the water leakage structure for solution of problem and repair

  • PDF

Non-destructive Leakage Location Analysis Method in Substrate Behavior Response Testing of Waterproofing Membrane Systems using Thermal Emission Camera

  • Oh, Kyu-Hwan;Jiang, Bo;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.47-48
    • /
    • 2017
  • The substrate behavior response testing outlined in KS F 2622 evaluates the leakage cause of waterproofing membrane systems when subjected to the concrete joint load behaviors by removing the waterproofing layer after testing, relying mostly on visual observation and subjective analysis. A non-destructive leakage cause and failure type analysis method is proposed currently in this study by the means of detecting leakage paths using thermal emission imaging systems. Test specimens are placed in varying temperature conditions after the concrete joint movement testing and are scanned using the thermal emission camera to determine the location and dimension of the adhesion failure/leakage path beneath the waterproofing membranes.

  • PDF

Study on the injecting technology of waterproofing layer for water leakage repair of roof (건축물 옥상방수층의 누수보수를 위한 방수층재형성 주입기술에 관한 연구)

  • 배기선;조일규;장혁수;곽규성
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.23-27
    • /
    • 2002
  • Waterproofing is one of the important factor to improve performance of building elements. But existing repair system for waterproofing have many problems like a damage of waterproof layer due to movement of concrete substrate, blistering effect and moisture condition. So waterproofing layer can not play an important part to improve waterproofing function and performance of building. Therefore, new waterproofing system to solve these problems of existing waterproofing system is developed. In this paper, new waterproofing system in water-leakage repair for remodeling is introduced

  • PDF

A study on the characteristic of adhesion on the low temperature concrete of self adhesive waterproofing sheet using interface leakage test. (계면 누수를 통한 자착형 방수시트의 저온 부착 특성에 관한 연구)

  • Choi, Su-Young;Kim, Meong-Ji;Lee, Jung-Hoon;Choi, Sung-Min;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.234-235
    • /
    • 2014
  • Recently, waterproof construction used to self adhesive waterproofing sheet in the actual field in winter for reduce cost and term. However self adhesive waterproofing sheet's quality is declined in low temperature condition. So, this study was to confirm on the low temperature condition of concrete substrate effecting the adhesion of self adhesion waterproofing sheet using interface leakage test. As a result of this study, self adhesion waterproofing sheet must not be used at temperature below 5℃. Also, adhesion between waterproofing sheet and concrete is declined in low temperature.

  • PDF

A Study On the Comparisons Between the Physical Properties of Self-Adhesive Waterproofing Sheets Applied with General Roller and Rotation Roller (일반 롤러와 회전식 롤러를 적용한 자착형 방수시트의 물성비교 연구)

  • An, Ki-Won;Park, Wan-Goo;Kim, Yun-Ho;Park, Jin-Sang;An, Dong-Su;Oh, Sang-keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.15-18
    • /
    • 2012
  • This study is to examine general roller and rotation in using self-adhesive waterproofing sheet. Using self-adhesive waterproofing sheet is very comfortable in a waterproofing construction site. However, In mechanical construction, self-adhesive waterproofing sheet occurred that problem for using. It induce many water leakage problem. So, We make Rotation Roller for to solve the this problem, and then Comparison with Physical properties of Self-Adhesive waterproofing sheet in applied General Roller and Rotation Roller.

  • PDF

An Experimental study on the Construction Standard for Sealer of Injection Type for Leakage Maintenance (누수보수용 주입형 실링재의 시공 기준에 관한 실험적 연구)

  • Lim Min-Chan;Cho Il-Kyu;Seon Yun-Suk;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.51-54
    • /
    • 2005
  • The concrete structure hasn't perfect waterproofing performance but if it doesn't have a joint part that could isolate a permeability. Concrete structure(communication tunnel and underground structure) has an expansion joint and construction joint. There are a lot of joint type after construction or expansion, shrinkage, vibration, over load, performance of decline etc.. they offer a water of way by variety change. In this reason, It carries in effect a waterproofing work for the concrete structure of waterproofing. but the structure has a behavior that cause a problem by waterproofing layer of damage, heaving phenomenon, temperature of shrinkage. In this study, we will estimate a field of application for Sealer of injection type for leakage maintenance of construction standard on the waterproofing performance.

  • PDF

An Experimental Study on the Damage of Waterproofing Membrane due to Oil ingredient of Underground Structures (유류성분이 지하구조물의 방수층 손상에 미치는 영향에 관한 실험적 연구)

  • Song Je-Young;Kang Hyo-Jin;Kwak Kyu-Sung;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.177-180
    • /
    • 2006
  • The accidents of oil leakage is increasing in the Underground Concrete structures for Oil Storege. In the result, the waterproofing in the underground structures is melt down and cannot fulfil its Performance. This study shows an experimental study in the effects of the oil leakage to on the performance of Waterproofing Materials. In order to investigate the actual condition and the problems, a comparative analyses were conducted considering the various types of leakage. Utilizing the obtained results at the basic data for test methods and the standard of quality, we intended to propose a strategy to develop an innovated waterproofing Materials and improve the clean environment of underground structures.

  • PDF

Domestic Below-Grade Waterproofing Design and Specification Standard for Residential Apartments (국내 공동주택의 지하공간 방수설계 및 시방기준)

  • Lee, Jung-Hun;Choi, Eun-Kyu;Song, Je-Young;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.185-186
    • /
    • 2018
  • Leakage problems in underground spaces of domestic apartments is becoming more serious and legal disputes related to leakage problem have become more commonplace. In this regard, leakage problem is not only a problem in construction, but is also a concern from a societal aspect. In this paper, we propose the details of a below-grade waterproofing design and specification standards of specific areas and sections of residential apartment buildings, and propose that a detailed examination of positive-side waterproofing methods is required.

  • PDF

Development of Waterproofing Method to Improve the Leakage Resistance and Maintenance of Underground Structures (구조물 누수 저항 및 유지관리 향상을 위한 방수공법 개발)

  • Kim, Eun-seok;Park, Hyun-Jung;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.50-51
    • /
    • 2020
  • Recently, various maintenance materials and construction methods have been developed to secure the sustainable performance of structures. However, waterproofing of underground structures where groundwater infiltration is present is very difficult. In particular, the location of underground structures such as subways is very deep, and it is difficult to apply waterproof materials and construction methods in the case of structures accompanied by vibration. Therefore, we intend to study materials and methods for waterproofing leakage resistance in special environments such as underground structures.

  • PDF