지하철 객차 내 환기 속도가 고압 미세물분무 화재제어 시스템의 성능에 대한 실험평가 (An Experimental Evaluation for the Effect of Ventilation Velocity in Subway Train on Performance of a High Pressure Water Mist Fire Suppression)

  • 김동운;배승용;김동석;박원희;유홍선
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1307-1312
    • /
    • 2007
  • This experiments are performed to investigate the effect of ventilation velocity on a high pressure water mist fire suppression in subway train. The experiment is conducted in half scale modeled train of a steel-welled enclosure (8.0m*2.4m*2.1m). The ventilation velocity is controlled by the ventilation duct through an inverter in the range of 0 to 2 m/s. The coverage-radius and an injection angle of an high pressure water mist system are measured. The mist nozzle with 7-injection holes is operated with pressure 80 bar. The heptane pool fires are used. The fire extinguishment times and the temperatures are measured for the ventilation velocities. In conclusion, because the momentum of injected water mist is more dominant than that of ventilation air, the characteristics of water mist, the fire extinguishment times and the temperatures are affected very little by ventilation velocity.

  • PDF

Water Mist 분무액적에 의한 스모크-로깅현상에 관한 연구 (A Study on the Smoke-logging Phenomenon caused by Water Mist)

  • 윤웅기;구인혁;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.249-250
    • /
    • 2015
  • This study contemplated the descending air current from the smoke layers related to the smoke logging phenomenon in the Water Mist applied design for effective evacuation safety design. As a result, database on the average particle diameter, particle velocity and distribution of sprinkling was obtained and the relationship between the water amount and particle diameter was obtained. Also Descending smoke velocity was significantly faster to 9.8m/s, it is determined that appeared rapidly by a high water pressure.

  • PDF

미분무수 소화시스템의 도로터널 적용을 위한 실물 화재 실험 (Full-scale Fire Suppression Test for Application of Water Mist System in Road Tunnel)

  • 한용식;최병일;김명배;이유환;소수현
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.51-56
    • /
    • 2011
  • 도로터널에서의 미분무수 소화시스템의 화재진압 특성을 조사하기 위해 실물 터널 화재 실험을 수행하였다. 적용된 소화시스템은 압력이 3.5 bar인 저압 물분무 소화설비와 60 bar인 고압 미분무수 소화시스템이다. 미분무수 소화시스템은 물분무 소화시스템의 1/6 만큼의 소화용수량을 사용한다. 화원 (fire source)은 실물 승용차와 유류화재를 모사한 화원면적 $1.4m^2$의 헵탄 연료 팬 화재로 구성하였다. 터널 내의 환기조건을 구현하기 위해 실물모형 터널의 한쪽 끝단에 유속(0.9~3.8 m/sec 범위) 발생장치를 설치하였으며, 화원에서 하류 방향으로 터널 내 온도분포는 K-type 열전대 트리를 사용하여 측정하였다. 실험 결과 고압 미분무수 소화시스템은 B급 화재의 경우 저압 물분무 시스템과 동등한 수준의 냉각효과를 보였다.

미세 물분무를 이용한 객차내의 화재제어 성능시험 (Performance Tests of Fire Control Using Water Mist in a Coach)

  • 김동현;박원희;장용준;이한수;유홍선;강중구;박정렬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1814-1818
    • /
    • 2007
  • The Korea Railroad Research Institute developed a fire control system for coaches using water mist. The fire control technology using water mist is used in the fire control system embedded in coaches developed through research. Such environment-friendly, automatic fire-extinguishing device is also economical because the amount used is significantly less than that of the existing sprinkler system. The paper introduces the developed fire control system and fire control performance tests using such system.

  • PDF

선박용 소화설비의 국제동향 (Trends of Onboard Fire Extinguishing System)

  • 김만응
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.126-127
    • /
    • 2005
  • This paper provides information on the current issues and the progress of on-going researches relating onboard fixed fire extinguishing system in the IMO Sub-committee on Fire Protection. And also prepares to introduce the recent amendment to regulations and technical trends of the water mist fire extinguishing system and high expansion foam system.

  • PDF

비냉각형 적외선 센서를 이용한 열상시스템과 냉각형 적외선 센서를 이용한 열상시스템의 화재 진압 시 성능 비교 (Performance Comparison of Thermal Imagers with Uncooled and Cooled Detectors For Fire Fighting Application)

  • 김병혁;정한;김영호
    • 제어로봇시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.128-132
    • /
    • 2007
  • Thermal Imaging systems are reported to be crucial for fire fighting and beginning to be used by fire fighters. The performance of thermal imaging system is determined by both the radiation of infrared from the target and the attenuation of infrared signal in the optical path by the absorption, scattering, diffraction and reflection. In the scene of fire, water drops with various sizes such as vaporized water, wafer mist from sprinkler, and wafer to suppress the fire reside with various gas generated by burning. To measure the transmission of infrared radiation in the scene of fire, fire simulating system and thermal imagers with cooled detector which detects $3{\sim}5{\mu}m$ infrared and uncooled detector fabricated by the MEMS technology which detects $8{\sim}12{\mu}m$ infrared. are made. With thermal imagers and Ire simulating system, the change of thermal image with respect to the change of visibility controlled with the burned fas was measured. It was found that the transmission of infrared was not reduced by the burned gas, which could be explained by the long wavelength of infrared ray compared with visible ray. However, the transmission of infrared ray was largely reduced by the combination of burned gas and water mist supplied by sprinkler. This is contrary to the results of calculated transmission through the pure water mist and shows that the transmission of infrared ray is mostly affected by the compounds of water mist and burned gas. In this case, it was found that the uncooled detector which detects $8{\sim}12{\mu}m$ infrared ray is better than cooled detector which detects $3{\sim}5{\mu}m$ infrared ray for fire fighting.

변전소 주변압기실 미분무수 소화시스템 성능평가를 위한 화재시나리오 (A Fire Scenario for Application of Water Mist System to an Indoor Power Transformer Room)

  • 최병일;한용식;김명배
    • 한국화재소방학회논문지
    • /
    • 제19권3호
    • /
    • pp.52-57
    • /
    • 2005
  • 미분무수 소화시스템의 소화구조는 분무되는 물의 조건뿐만 아니라 방호대상 공간의 상태에도 의존하기 때문에 일반적인 설계기준을 마련 할 수 없는 실정이다. 따라서 보편적인 성능평가 방법도 있을 수 없기 때문에 방호 대상물과 공간이 결정되면 그에 적절한 성능평가 기준이 마련되어야 한다. 본 연구에서는 변전소 주변압기실에 미분무수 소화시스템을 적용하기 위하여 성능평가 기준을 제안하고자 한다. 이를 위하여 유사 화재사례 조사, 사고 분석, 유사 성능평가기준 분석 등을 수행하였다.

급속 열처리 시스템을 위한 물/공기 액적류 충돌 제트의 냉각 특성에 관한 연구 (Cooling Performance of Air/Water Mist Jet Impinging for a Rapid Thermal Annealing System)

  • 이준경
    • 한국기계가공학회지
    • /
    • 제14권5호
    • /
    • pp.68-74
    • /
    • 2015
  • In the present work, a series of numerical calculations have been conducted on the cooling of a hot surface using an air/water mist jet. In some cooling processes, such as in the glass-tempering process, direct contact between the cold water drops and the hot surface should be avoided, because this may cause surface cracks due to the sharp temperature gradients. Thus, the main focus of this study is finding the appropriate operating conditions for maximum cooling without direct contact between the drops and the surface. A series of numerical experiments have been performed, and, at the same time, those results were compared with those of the previous experiments for verification purposes. The effects of droplet impinging velocity, hot plate temperature, and liquid loading ratio for mono-dispersed drops of various sizes were studied in detail.

Ro-Ro 구역용 미분무 소화설비의 개발을 위한 실험적 연구 (An experimental study on development of water mist fire-fighting systems for Ro-Ro spaces)

  • 곽지현;김영한
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권8호
    • /
    • pp.946-952
    • /
    • 2013
  • 선박의 Ro-Ro 구역이나 특별범주구역의 화재방호를 위해 설치하는 고정식 수계소화설비의 개발 및 실용화를 위해, 특히 방수량이 적으며 관련기준에서 요구하는 성능요건을 만족하는 미분무 노즐을 개발하고자 실물화재실험을 수행하였다. 본 설비의 화재시나리오는 크게 두 가지로 트럭화물화재와 승용차화재로 구분되며, 각각 고정 설치된 미분무 노즐과 화원과의 세 가지 위치에 대한 시나리오로 이루어져 있다. 모든 화재실험은 30분간 진행되었으며 천장부의 가스온도와 우드펠릿의 손상율, 타깃합판의 착화여부로 판단되었다. 본 논문은 두 가지 화재실험 중 조건이 더욱 까다로운 트럭화재용 미분무 노즐의 결과를 위주로 방수압력과 방수량, 미분무수의 유동특성에 따른 화재실험결과와 화재진압특성을 고찰하였으며, 수십 회의 반복실험 결과 분당 약 40 L의 유량을 가지는 저압 미분무 노즐로 Ro-Ro구역의 화재진압이 가능한 것으로 나타났다.

첨가제가 혼합된 미세물분무의 소화성능에 관한 연구 (A Study on the Extinguishing Performance of Water Mist with Additives)

  • 이경덕;신창섭
    • 한국화재소방학회논문지
    • /
    • 제16권1호
    • /
    • pp.1-7
    • /
    • 2002
  • 할론 소화약제는 오존층파괴지수와 지구온난화지수가 높아 환경문제를 야기하며, 이의 대체기술의 일환으로 미세물분무에 대한 관심이 집중하고 있다. 미세물분무에 대한 연구로는 적용화재에 보다 효과적인 소화를 위한 최적의 물입자를 만들려는 연구와 함께 첨가제를 이용하여 미세물분무의 소화성능을 향상시키기 위한 연구가 진행되고 있다. 본 연구는 이전 연구$^{1)}$ 에서 제시한 순수한 미세물분무의 입자크기, 방사분포 및 화염크기에 따른 ethanol과 n-heptane 화염의 진압특성과 소화시간에 대한 연구를 기반으로, 여기에 미세물분무의 물리적 소화성능의 향상과 화학적 소화성능을 부여하기 위해 첨가제를 첨가하였을 때의 성능을 평가하고 최적의 조건을 구하고자 하였다. 실험결과, ethanol panl 화염에 7N3노즐을 4kg/$\textrm{cm}^2$로 방사한 경우 0.3% AFFF와 2.5wt% NaCl를 첨가한 미세물분무는 순수한 미세물분무 보다 27%와 60% 빠른 소화시간을 나타냈다. AFFF의 첨가는 연료표면 위에서 얇은 막을 형성하여 화염으로부터 연료 표면으로 되돌아오는 열을 감소하므로 연료표면에서의 화염온도 감소와 함께 n-heptane 연료의 증발을 감소함으로서 소화가 이루어지는 것으로 판단되며, 또한 알칼리 염인 2.5wt% NaCl을 첨가한 경우 화염면에 알칼리염 결정체가 형성되는 현상이 나타났다.