• 제목/요약/키워드: water-level

검색결과 9,432건 처리시간 0.038초

보일러용 정전용량형 수위센서 시스템 개발 (Development of Capacitive Water Level Sensor System for Boiler)

  • 이영태;권익현
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.103-107
    • /
    • 2021
  • In this paper, a capacitive water level sensor for boilers was developed. In order to accurately monitor the water level in a high-temperature boiler that generates a lot of precipitates, the occurrence of precipitates on the surface of the water level sensor should be small, and a sensor capable of measuring even if the sensor surface is somewhat contaminated is required. The capacitive water level sensor has a structure in which one of the two electrodes is insulated with Teflon coating, and the stainless steel package of the water level sensor is brought into contact with the water tank so that the entire water tank becomes another electrode of the water level sensor. A C-V converter that converts the capacitance change of the capacitive water level sensor into a voltage change was developed and integrated with the water level sensor to minimize noise. The performance of the developed capacitive water level sensor was evaluated through measurement.

금강하구둑 배수갑문 조작에 의한 상류수역의 수위변동 (Variation of Water Level on the Upstream Gauging Station by Operation of the Drainage Sluice Gate of Geumgang Estuary Dam)

  • 박승기
    • 한국농공학회논문집
    • /
    • 제47권6호
    • /
    • pp.15-24
    • /
    • 2005
  • The normalization on the characteristics of water level change at the upstream gauging station was attempted according to the operation of drainage sluice gate of the Geumgang estuary dam. The characteristics were normalized by the analysis of water level change and by the linear-regression of the water level data measured at the inner station of Geumgang estuary dam and upstream gauging station. The results of normalization may be referred to the management of Geumgang estuary lake, the operation of pumping and drainage stations in the shore of the lake. The mean response time of water level change on Ibpo, Ganggyeong and Gyuam water level station were 39,81 and 160 minutes, when sluice gate was opened respectively. The mean velocity of surface wave, the mean displacement of water level change, the mean time of water level change and the mean rate of water level change varied largely depending on the location of gauging station and the characteristics of stream section of the water level gauging station.

지하수 개발 및 양수기간에 따른 수위 변동특성 분석 (Analysis of Water Level Fluctuations according to Groundwater Development and Pumping Duration)

  • 김민철;양성기;이준호
    • 한국환경과학회지
    • /
    • 제25권1호
    • /
    • pp.135-146
    • /
    • 2016
  • This study analyzed fluctuations of ground water level of ground water wells developed in Seongsan watershed of Jeju Island until 2013 using MODFLOW, a numerical analysis model. Ground water level shows greater fluctuations from increase of pump capacity compared to the number of ground water wells. The development of ground water at the top of watershed was found to have direct influence on ground water level. Ground water wells developed until 2013 were used to continue pumping for 50 days, and ground water level of coastal region was reduced below 50% compared to the standard water level. In addition, the range of fluctuation of water level was large in the east coast region, which represents the direction of flow of ground water.

Water Level Tracking System based on Morphology and Template Matching

  • Ansari, Israfil;Jeong, Yunju;Lee, Yeunghak;Shim, Jaechang
    • 한국멀티미디어학회논문지
    • /
    • 제21권12호
    • /
    • pp.1431-1438
    • /
    • 2018
  • In this paper, we proposed a river water level detection and tracking of the river or dams based on image processing system. In past, most of the water level detection system used various water sensors. Those water sensors works perfectly but have many drawbacks such as high cost and harsh weather. Water level monitoring system helps in forecasting early river disasters and maintenance of the water body area. However, the early river disaster warning system introduces many conflicting requirements. Surveillance camera based water level detection system depends on either the area of interest from the water body or on optical flow algorithm. This proposed system is focused on water scaling area of a river or dam to detect water level. After the detection of scale area from water body, the proposed algorithm will immediately focus on the digits available on that area. Using the numbers on the scale, water level of the river is predicted. This proposed system is successfully tested on different water bodies to detect the water level area and predicted the water level.

상류 수위관측소 자료를 활용한 하류 지점 수위 예측 (Prediction of Water Level at Downstream Site by Using Water Level Data at Upstream Gaging Station)

  • 홍원표;송창근
    • 한국안전학회지
    • /
    • 제35권2호
    • /
    • pp.28-33
    • /
    • 2020
  • Recently, the overseas construction market has been actively promoted for about 10 years, and overseas dam construction has been continuously performed. For the economic and safe construction of the dam, it is important to prepare the main dam construction plan considering the design frequency of the diversion tunnel and the cofferdam. In this respect, the prediction of river level during the rainy season is significant. Since most of the overseas dam construction sites are located in areas with poor infrastructure, the most efficient and economic method to predict the water level in dam construction is to use the upstream water level. In this study, a linear regression model, which is one of the simplest statistical methods, was proposed and examined to predict the downstream level from the upstream level. The Pyeongchang River basin, which has the characteristics of the upper stream (mountain stream), was selected as the target site and the observed water level in Pyeongchang and Panwoon gaging station were used. A regression equation was developed using the water level data set from August 22th to 27th, 2017, and its applicability was tested using the water level data set from August 28th to September 1st, 2018. The dependent variable was selected as the "level difference between two stations," and the independent variable was selected as "the level of water level in Pyeongchang station two hours ago" and the "water level change rate in Pyeongchang station (m/hr)". In addition, the accuracy of the developed equation was checked by using the regression statistics of Root Mean Square Error (RMSE), Adjusted Coefficient of Determination (ACD), and Nach Sutcliffe efficiency Coefficient (NSEC). As a result, the statistical value of the linear regression model was very high, so the downstream water level prediction using the upstream water level was examined in a highly reliable way. In addition, the results of the application of the water level change rate (m/hr) to the regression equation show that although the increase of the statistical value is not large, it is effective to reduce the water level error in the rapid level rise section. Accordingly, this is a significant advantage in estimating the evacuation water level during main dam construction to secure safety in construction site.

A survey on the application of ICTs in automated water level gauges for agricultural reservoirs

  • Min-Gi Jeon;Jin-Taek Kim;Won-Ho Nam
    • 농업과학연구
    • /
    • 제51권2호
    • /
    • pp.217-225
    • /
    • 2024
  • Timely and appropriate water supply to paddy fields is crucial for efficient agricultural water management. In South Korea, 17,240 agricultural reservoirs supply approximately 60% of the agricultural water and play a pivotal role in irrigation and drought mitigation. These reservoirs are managed by the Korea Rural Community Corporation (KRC), which oversees 3,411 reservoirs, and various local governments, which manage 13,829 locations. Guidelines from the Ministry of Agriculture, Food and Rural Affairs (MAFRA) mandate the installation and operation of water level measurement instruments. Currently, automated water level facilities are installed in 1,734 reservoirs and 1,880 irrigation canals, generating water level data at ten-minute intervals. In this study, a survey was conducted to enhance the management of agricultural reservoirs by integrating advanced information and communications technology (ICT) into existing automated water level gauge systems. We propose directions for enhancing the automated water level gauges in agricultural reservoirs. The findings would provide foundational data for stable and systematic management of these gauges.

판별분석을 통한 농촌유역 소하천의 수질등급모형(WQLM) 개발 및 적용 (Development and Application of Water Quality Level Model (WQLM) for the Small Streams of Rural Watersheds with Discriminant Analysis)

  • 김진호;최철만;류종수;정구복;신중두;한국헌;이정택;권순국
    • 한국물환경학회지
    • /
    • 제23권2호
    • /
    • pp.260-265
    • /
    • 2007
  • This study was carried out to complement water quality standards and to establish new concept for water quality standards reflecting current state of water quality in small streams. By this purpose, discriminant analysis was performed and Water Quality Level Model (WQLM) was developed using the data such as EC, BOD, $COD_{Mn}$, SS, T-N, T-P, $NH_3-N$ in 224 agricultural streams. To give water quality level for water quality parameters, it divided into 20% respectively in the order of excellent water quality. On the basis of the lowest water quality level, water quality level of small streams is granted. As a result of it, number of stream corresponding to Level I was no, Level II was 2 streams, Level III was 22 streams, Level IV was 70 streams, and Level V was 130 streams. Average of water quality in each level was the highest in Level V. EC, SS, and T-N of 7 parameters were selected in variance concerned water quality level. By standardized canonical discriminant function coefficient, EC of three variances was the highest in 0.625 at the discriminant power. The next was T-N (0.509), SS (0.414). By discriminant function for water quality level, Level II was equal to $-2.973+19.376{\times}(EC)+0.647{\times}(T-N)+0.009{\times}(SS)$, Level III was equal to $-3.288+19.190{\times}(EC)+0.733{\times}(T-N)+0.041{\times}(SS)$, Level IV was equal to $-4.462+27.097{\times}(EC)+0.792{\times}(T-N)+0.053{\times}(SS)$, and Level V was equal to $-9.117+40.040{\times}(EC)+1.305{\times}(T-N)+0.111{\times}(SS)$. As a result of test at real agricultural watershed of Jeongan and Euidang in Gongju city, the fitness of WQLM was high to 88.78%. But, to get accomplished water quality assessment more exactly in agricultural streams, we had to concentrate and get vast data, and WQLM was modified and complemented continually.

Water level fluctuations of the Tonle Sap derived from ALOS PALSAR

  • Choi, Jung-Hyun;Trung, Nguyen Van;Won, Joong-Sun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.188-191
    • /
    • 2008
  • The Tonle Sap, Cambodia, is a huge lake and periodically flooded due to monsoon climate. The incoming water causes intensive flooding that expands the lake over vast floodplain and wetland consisting mainly of forests and shrubs. Monitoring the water-level change over the floodplain is essential for flood prediction and water resource management. A main objective of this study is flood monitoring over Tonle Sap area using ALOS PALSAR. To study double-bounce effects in the lake, backscattering effect using ALOS PALSAR dual-polarization (HH, HV) data was examined. InSAR technique was applied for detection of water-level change. HH-polarization interferometric pairs between wet and dry seasons were best to measure water level change around northwestern parts of Tonle Sap. The seasonal pattern of water-level variations in Tonle Sap studied by InSAR method is similar to the past and altimeter data. However, water level variation measured by SAR was much smaller than that by altimeter because the DInSAR measurement only represents water level change at a given region of floodplain while altimeter provides water level variation at the central parts of the lake.

  • PDF

수위계 표준시험장치 개발 및 최고측정능력에 관한 연구 (Best Measurement Capability and Standard Test Facility for the Water-level Gauges)

  • 신강욱;홍성택
    • 제어로봇시스템학회논문지
    • /
    • 제13권10호
    • /
    • pp.1012-1017
    • /
    • 2007
  • Rain data and water-level data are importantly used for dam operation at flood period. Because dams are directly controlled by the water-level data, the characteristic of the water-level gauges is necessary to be managed. Thus, we developed the standard test facility and method for testing the water-level gauges which are a float type, a supersonic type and a radar type. And we calculated the uncertainty of the standard test facility to maintain the accuracy of water-level gauges. Through development of this facility, we could obtain the characteristics and the calibration factor of the water-level gauges. And, this study showed that the standard test facility can be widely used for dam operation and basin management.

낙동강 하류지역의 저수지, 하천 및 지하수위 자료의 상관관계 분석 (Correlation Analysis with Reservoir, River, and Groundwater Level Data Sets in Nakdong River Watershed)

  • 양정석;유가영;안태연;김정은
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.1151-1154
    • /
    • 2008
  • The water level data sets among hydrologic observation data are correspond to the hydraulic head for each observation point and determine flow direction. The level difference among reservoir, river, and groundwater determines groundwater flow direction, just like water flows in the downstream direction because the water level of upstream point is higher than that of downstream point. We can analyze the relationship among the components in hydrologic cycle by comparing the water level differences. This research dealt with the data from Nakdong river watershed in Gyungsangnam-Do. Three data group are used for the analysis and onr group is composed of reservoir, river, and groundwater data sets. The data sets are closely(within 10 km) located in the interested area.

  • PDF