• Title/Summary/Keyword: water-hammering method

Search Result 17, Processing Time 0.021 seconds

A Numerical Study on the Reduction of Water Hammering in a Simple Water Supply Pipe System

  • Lim, Ki-Won;Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.51-61
    • /
    • 2001
  • A numerical study has been conducted to characterize the transient pressure in a simple water supply pipe system with an air chamber by utilizing a commercial code that employs the method of characteristics. Some results produced for validation in the study agree quite well with the previously reported. Several parameters are than varied. Among them are the valve closure time, the wave speed, the static pressure, the polytropic exponent, the air chamber volume, the diameter and the shape of orifice in the air chamber, etc, while the water temperature and velocity are kept constant at $20^\circ{C}$ and 0.8m/s, respectively. Results reported in this parametric study may be useful to understand the unsteady behavior of the system.

  • PDF

A Study on Valve-Induced Water Hammer Characteristics for Large Pump System (밸브에 의한 대형펌프시스템의 수격특성에 관한 연구)

  • Lee, C.J.;Lim, K.S.;Cho, D.H.
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2009.06a
    • /
    • pp.177-178
    • /
    • 2009
  • Hydraulic Transients would be occurred since pressure is increased or decreased when water speed inside of pipeline is rapidly changed A study on water hammer has become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. In this study, the method of characteristic line was adopted to evaluate the valve-induced water hammer phenomena in a pumps feedwater system.

  • PDF

Analysis of the change in appearance according to the hardening method of leather (가죽의 경화방법에 따른 외형변화 분석)

  • Youshin, Park
    • Journal of Fashion Business
    • /
    • v.26 no.5
    • /
    • pp.122-134
    • /
    • 2022
  • This study is conducted on hardening leather with improved firmness and stability of shape, based on research on types and thickness of leather. The purpose of this study is to test the physical properties of the leather for molding to prepare the foundation for leather molding based on the test results using four methods by thickness of Vegetable and Split. The tests were conducted using a total of five leather types, including three types of vegetable leathers and two types of split, by thickness. Based on the testing method for leathers in KS M 6882, the tests were performed at 27℃ with relative humidity of 65±20%. The samples were prepared with cowhide, size 9cm× 2cm. The measurement parameters are length and width. thickness, volume, mass, density. Regarding the hardening treatment method, changes in appearance and major physical characteristics of leather were reviewed by soaking in hot water, dry heating, hammering, waxing, and olive oil coating. The study results are as follows. In planar works, it is judged that hardening work using a hammer is more suitable for stiffness or density in order to prevent easy breakage with adult muscle density, rather than boiling water or baking. In conclusion, there is no curling, soot, or breaking phenomenon, and the densest curing method is 50℃ for 20 sec of V2 and 75℃ for 60 sec of V2 in boiling water. The combination of paraffin treatment improve waterproof and quality.

A Study on Ganui-Dae's External Form and Its Modeling for Restoration

  • Lee, Min-Soo;Lee, Yong Sam;Jeon, Jun Hyeok;Kim, Sang Hyuk
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.299-305
    • /
    • 2013
  • Ganui-Dae, built in the reign of King Sejong, Joseon Dynasty, is a comprehensive observatory. It has various instruments for observation and time signal such as Ganui, Gyupyo(Gnomon), water-hammering type Honui and Honsang, and so on. Studying on Ganui-Dae has been focused on its location, history, criterion, etc, so far. However, studying on its external form and construction method has been conducted insufficiently. This study suggests the model for restoration of Ganui-Dae. The model is based on the analysis about external form of Ganui-Dae in various antique maps, and its construction method in those days.

A Study on the Operation Mechanism of Ongnu, the Astronomical Clock in Sejong Era

  • Kim, Sang-Hyuk;Lee, Yong-Sam;Lee, Min-Soo
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.1
    • /
    • pp.79-91
    • /
    • 2011
  • Ongnu (Jade Clepsydra; also called Heumgyeonggaknu) is a water clock was made by Jang Yeong-sil in 1438. It is not only an automatic water clock that makes the sound at every hour on the hour by striking bell, drum and gong, but also an astronomical clock that shows the sun's movement over time. Ongnu's power mechanism used is a water-hammering method applied to automatic time-signal device. The appearance of Ongnu is modeled by Gasan (pasted-paper imitation mountain) and Binpungdo (landscape of farming work scene) is drawn at the foot of the mountain. The structure of Ongnu is divided into the top of the mountain, the foot of the mountain and the flatland. There located are sun-movement device, Ongnyeo (jade female immortal; I) and Four gods (shaped of animal-like immortals) at the top of the mountain, Sasin (jack hour) and Musa (warrior) at the foot of the mountain, and Twelve gods, Ongnyeo (II) and Gwanin on the flatland. In this study, we clearly and systematically understood the time-announcing mechanism of each puppet. Also, we showed the working mechanism of the sun-movement device. Finally, we completely established the 3D model of Ongnu based on this study.

Development and demonstration of an erosion-corrosion damage simulation apparatus (배관 침부식 손상 연속모사 장비 개발 및 실증)

  • Nam, Won Chang;Ryu, Kyung Ha;Kim, Jae Hyoung
    • Corrosion Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.179-184
    • /
    • 2013
  • Pipe wall thinning caused by erosion and corrosion can adversely affect the operation of aged nuclear power plants. Some injured workers owing to pipe rupture has been reported and power reduction caused by unexpected pipe damage has been occurred consistently. Therefore, it is important to develop erosion-corrosion damage prediction model and investigate its mechanisms. Especially, liquid droplet impingement erosion(LDIE) is regarded as the main issue of pipe wall thinning management. To investigate LDIE mechanism with corrosion environment, we developed erosion-corrosion damage simulation apparatus and its capability has been verified through the preliminary damage experiment of 6061-Al alloy. The apparatus design has been based on ASTM standard test method, G73-10, that use high-speed rotator and enable to simulate water hammering and droplet impingement. The preliminary test results showed mass loss of 3.2% in conditions of peripheral speed of 110m/s, droplet size of 1mm-diameter, and accumulated time of 3 hours. In this study, the apparatus design revealed feasibility of LDIE damage simulation and provided possibility of accelerated erosion-corrosion damage test by controlling water chemistry.

A Study on the Performance Evaluation of Fitting for Light-gauge Stainless Steel Pipe (경량 스테인리스 강관용 이음쇠의 성능평가에 관한 연구)

  • Nam, Jun-Seok;Park, Joo-Hwan;Min, Kyung-Tak;Kim, Yeob-Rae;Song, Chul-Gang
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.89-97
    • /
    • 2010
  • In recent fire protection system, the pipings should be light weighted, seismic proof and wrought with non-welding method. The light weighted stainless steel pipes and fittings, satisfying these requirements, are already used as a fire protection system in Germany, Netherland, Taiwan, Australia, United States and Japan. Accordingly, performance evaluation tests were carried out to determine whether or not the fittings can be used in the pipings. As the performance evaluation tests, we conducted vibration test, water hammering test, bending test and fire test. With the results of the tests, we concluded that the fittings can be used in the fire protection system, and that the life expectancy of the fittings exceeds that of buildings.