• Title/Summary/Keyword: water-cement mix ratio

Search Result 218, Processing Time 0.02 seconds

Mechanical Properties of Soil-Cement with Mixed Low (저배합 흙-시멘트의 역학적 특성)

  • 공길용;이득원;전상옥;김석열
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.665-672
    • /
    • 2002
  • In order to expand agricultural lands in the western and southern coasts of Korean Peninsula, coarse soils excavated from hillsides have been used as fill materials for reclamation. In order to tackle with the problems and to confirm availability, research on soil improvement involve mixing cement to the fine wet soils. Required undrained shear strength(c$\sub$u/) for fill material was analyzed to be 0.34∼1.2kg/$\textrm{cm}^2$. It has been known that when cement is added to high water content marine clay, its unconfined compression strength increased to 2kg/$\textrm{cm}^2$. Consolidation results show that pre-consolidation pressure increased to 1.8kg/$\textrm{cm}^2$ and 3.4kg/$\textrm{cm}^2$ with the addition of 3% and 5% of cement respectively. This result shows that low-height embankments could be constructed without significant compression. Since the effectiveness of improvement may be different site by site, the mix design for each site is necessary in order to optimize it. The process is first to determine aimed shear strength and then optimum mix ratio of cement after carrying out a series of tests.

  • PDF

Physical Properties and Durability of Polymer Modified Mortar Using Styrene and Butyl Acrylate Latexes (St/BA 폴리머 시멘트 모르타르의 물리적 특성 및 내구성)

  • Hyung, Won-Gil
    • Polymer(Korea)
    • /
    • v.33 no.4
    • /
    • pp.342-346
    • /
    • 2009
  • The effects of the monomer ratios on the typical properties of polymer modified mortars that contain styrene and butyl acrylate latexes was investigated. Basic data was also obtained that is necessary for the development of appropriate latexes for cement modifiers. Polymer modified mortars that contain styrene and butyl acrylate latexes polymerized with various monomer ratios were prepared for different polymer-cement ratios. They were then tested to obtain the particle size of the polymer latexes, air contents, water-cement ratios, flexural and compressive strengths, water absorption, and chloride-ion penetration. From the test results, the polymer modified mortars that have styrene and butyl acrylate latexes (with the mix proportions of synthesis having monomer ratios of between 40:60 to 60:40 for the appropriate mix proportions) could be recommended for practical applications. The basic properties of the polymer modified mortars were more affected by the polymer-cement ratio than by the monomer ratio, and were improved over unmodified mortar.

Optimizing the mix design of pervious concrete based on properties and unit cost

  • Taheri, Bahram M.;Ramezanianpour, Amir M.
    • Advances in concrete construction
    • /
    • v.11 no.4
    • /
    • pp.285-298
    • /
    • 2021
  • This study focused on experimental evaluation of mechanical properties of pervious concrete mixtures with the aim of achieving higher values of strength while considering the associated costs. The effectiveness of key parameters, including cement content, water to cement ratio (W/C), aggregate to cement ratio (A/C), and sand replacement was statistically analyzed using paired-samples t-test, Taguchi method and one-way ANOVA. Taguchi analysis determined that in general, the role of W/C was more significant in increasing strength, both compressive and flexural, than cement content and A/C. It was found that increase in replacing percent of coarse aggregate with sand could undermine specimens to percolate water, though one-way ANOVA analysis determined statistically significant increases in values of strength of mixtures. Cost analysis revealed that higher strengths did not necessarily correspond to higher costs; in addition, increasing the cement content was not an appropriate scenario to optimize both strength and cost. In order to obtain the optimal values, response surface method (RSM) was carried out. RSM optimization helped to find out that W/C of 0.40, A/C of 4.0, cement content of about 330 kg/m3 and replacing about 12% of coarse aggregate with sand could result in the best values for strength and cost while maintaining adequate permeability.

An Experimental Study on the Ultra High Strength Concrete Using Silica-Fume and Fly-Ash (실리카흄 및 플라이애쉬를 사용한 초고강도 콘크리트에 관한 실험적 연구)

  • 박기철;정헌수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1991.04a
    • /
    • pp.23-28
    • /
    • 1991
  • Silica-Fume, an industrial by product, has an extremely small average partical size of 0.1${\mu}{\textrm}{m}$ and when used as a concrete admixture fills the fine voids which exist in concrete. The purpose of this study is to investigate material properties of the high-strength concrete using Silica-Fume and Fly-Ash. The main variables studied are; a) water-cement ratio. b) Silica-Fume, Fly-Ash content. The maximum compressive strength of 1000Kg/$\textrm{cm}^2$ is achieved with a mix using 18% water-cement ratio, 20% Silica-Fume and 10% Fly-Ash ratio.

  • PDF

Evaluation of grout penetration in single rock fracture using electrical resistivity

  • Lee, Hangbok;Oh, Tae-Min;Lee, Jong-Won
    • Geomechanics and Engineering
    • /
    • v.24 no.1
    • /
    • pp.1-14
    • /
    • 2021
  • In this study, a new approach using electrical resistivity measurement was proposed to detect grout penetration and to evaluate the grouting performance for such as waterproof efficiency in single rock fracture. For this purpose, an electrical resistivity monitoring system was designed to collect multi-channel data in real time. This was applied to a system for grout injection/penetration using a transparent fracture replica with various aperture sizes and water-cement mix ratio. The electrical resistivity was measured under various grout penetration conditions in real time, which results were directly compared to the visual observation images of grout penetration/distribution. Moreover, the grouting success status after the curing process was evaluated by measuring the electrical resistivity in relation to changes in frequency in fracture cells where grout injection and penetration were completed. Consequently, it was determined that the electrical resistivity monitoring system could be applied effectively to the detection of successful penetration of grouting into a target area and to actual field evaluation of the grouting performance and long-term stability of underground rock structures.

Mixing and Strength Properties of 150MPa Ultra High Strength Concrete (150MPa 초고강도 콘크리트 배합 및 강도발현 특성)

  • Ahn, Jong-Mun;Kang, Hoon;Kim, Jong-Keun;Shin, Sung-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.373-376
    • /
    • 2008
  • Ultra High Strength Concrete(UHSC) is necessary a clear presentation about mechanical property that is different from normal strength concrete and an evaluation of serviceability of high rise building which is used ultra high strength concrete. To mixing ultra high strength concrete with $f_{ck}$=150MPa pre-mix cement were manufactured and experimental study were conducted to evaluated on the mixing properties and compressive strength with major variables as unit cement contents, water-binder ratio and type of pre-mix cement. As a test result, it is shown that the concrete mixing time is required about 5$^{\sim}$6 minute untill the each materials(ordinary portland cement, silica fume, blast-furnace slag powder and anhydrite) are revitalized enough. A slump flow of fresh concrete are shown about 700$^{\sim}$750mm with proper viscosity. And average value of concrete compressive strength are shown about 77% in 7days, 87% in 14days and 102% in 56days for 28days of concrete material age. From this experimental study, a proper mixture proportion of pre-mix cement are recommended about 54$^{\sim}$59% OPC, 25$^{\sim}$30% blast-furnace slag powder and 10$^{\sim}$15% silica fume for mix the ultra high strength concrete with $f_{ck}$=150MPa.

  • PDF

Prediction on Mix Proportion Factor and Strength of Concrete Using Neural Network (신경망을 이용한 콘크리트 배합요소 및 압축강도 추정)

  • 김인수;이종헌;양동석;박선규
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.457-466
    • /
    • 2002
  • An artificial neural network was applied to predict compressive strength, slump value and mix proportion of a concrete. Standard mixed tables were trained and estimated, and the results were compared with those of the experiments. To consider variabilities of material properties, the standard mixed fables from two companies of Ready Mixed Concrete were used. And they were trained with the neural network. In this paper, standard back propagation network was used. The mix proportion factors such as water cement ratio, sand aggregate ratio, unit water, unit cement, unit weight of sand, unit weight of crushed sand, unit coarse aggregate and air entraining admixture were used. For the arrangement on the approval of prediction of mix proportion factor, the standard compressive strength of $180kgf/cm^2{\sim}300kgf/cm^2$, and target slump value of 8 cm, 15 cm were used. For the arrangement on the approval of prediction of compressive strength and slump value, the standard compressive strength of $210kgf/cm^2{\sim}240kgf/cm^2$, and target slump value of 12 cm and 15 cm wore used because these ranges are most frequently used. In results, in the prediction of mix proportion factor, for all of the water cement ratio, sand aggregate ratio, unit water, unit cement, unit weight of sand, unit weight of crushed sand, unit coarse aggregate, air entraining admixture, the predicted values and the values of standard mixed tables were almost the same within the target error of 0.10 and 0.05, regardless of two companies. And in the prediction of compressive strength and slump value, the predicted values were converged well to the values of standard mixed fables within the target error of 0.10, 0.05, 0.001. Finally artificial neural network is successfully applied to the prediction of concrete mixture and compressive strength.

Development of high-performance cement grout for ground heat exchangers (지중열교환기용 고성능 시멘트 그라우트 개발)

  • Lee, Dong-Chul;Yang, Hee-Jung;Jeon, Joong-Kyu;Seo, Shin-Seok;Choi, Yong-Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.1
    • /
    • pp.10-16
    • /
    • 2011
  • Performance of ground-source heat pumps (GSHPs) is mainly affected by ground heat exchangers which makes up more than 40% of construction cost. Exact construction and grout as backfill are important, because it is difficult to repair after being installed. As grout materials, bentonite grout material and cement material are used In this paper, thermal conductivity according to mix proportion of cement grout has been experimentally studied. Some variables were set to evaluate thermal conductivities according to change in cement content, unit water ratio, mass per volume of fresh mortar, and aggregate types. From the experimental analysis, high performance cement grout has been proposed.

A Study on the Improvement of Strength in No-Fines Concrete with Stone Dust (석분을 혼입한 무세골재 콘크리트의 강도 개선에 관한 연구)

  • 나성훈;조재병;임정순
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.3
    • /
    • pp.149-155
    • /
    • 1995
  • An experimental study was carried out to investigate the strength implovlng effect of stone dust in no fines concrete. The cement aggregate ratios of 1:6, 1:8 and 1:10 and several water-cemment ratios between 30% and 56% were chosen for the mix design of no-fines concrete. For the no-fines concrete with stone dust, the weight ratio of cement to stone dust 1:1 was adopted and super plasticizer, 1.5% of cement in weight, was used to obtain proper and workable state of concrete. The compressive and tensile strength test were performed and the results for the different mix designs were compared with each other. The results show that the compressive strength of no-fines concrete can be improved by 38% and the tensile strength by 17%~72% for the same w/c, when the same weight of stone dust as cement is mixed together.

Effect of S.E.C Mixing on the Properties of Concrete (S.E.C 방식에 의한 콘크리트의 혼합효과에 관한 연구)

  • 김기형;박원태;최재진
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.2
    • /
    • pp.133-139
    • /
    • 1997
  • Conventional concrete mixing method is to put all of the materials simultaneously into a mixer and mix for a required time. However, recently concrete researchers have reported that mixing sequence iufluences the properties of concrete. This study discusses the influence of mixing sequence and partitioning addition of mixing water. Concrete, by method of partitioning addition of mixing water, was found to have substantially stronger strength than conventional concrete with the same water-cement ratio. This means that a higher strength concrete could be obtained by using “Sand Enveloped with Cement”(S.E.C) mixing technique. Both a high bond strength between cement paste and aggregate, and elimination of bleeding both contribute to improving the strength of S. E. C concrete.

  • PDF