• 제목/요약/키워드: water wash

검색결과 217건 처리시간 0.03초

A Study on Microbial Contamination and Disinfection of Ultrasonic Probe in Metropolitan Area (수도권 지역의 초음파 프로브의 미생물 오염도와 소독에 관한 연구)

  • Lee, Hyun Kyung;Kim, Sam Soo;Heo, Yeong Cheol;Han, Dong Kyoon
    • Journal of radiological science and technology
    • /
    • 제41권5호
    • /
    • pp.427-435
    • /
    • 2018
  • There was a shortage of research reports on sterilization criterion and contamination of ultrasonic probes. Therefore, in this study, we were going to provide a basic study to measure the level of microbial contamination in ultrasonic probes and to investigate the radiographer's awareness of infection. After the scan, samples were collected from the rubber part of the probe by opening a sterile swab (Transport Medium AM608-1S) for medical bacteria collection with the remaining gel removed with a paper towel. Also, the collected samples of bacteria were grown for seven days and then the laboratory was analyzed. Among the total 29 types of microorganisms, Micrococcus luteus 21(26%), Moraxella species 16(20%), Coagulase negative staphylococcus 8(10%), Bacillus species 5(7%), Bicillus circulans 3(5%), Acinetobacter lwoffii 2(2%), and 1 other Candida parapsilosis (1%) a number of bacteria and fungus, was detected. In a disinfectant experiment using LuciPac Pen on the Lumitester PD-30s, we cultured the rubber part of the probe two to three times to measure the bacteria. Bacteria decreased to 97% with Aquanax (alkaline reduced water 100%), 99% with Klarion wash (0.01% sodium hydroxide), 94% with Klarion disinfection (0.01% nitrous acid water), Sterilization was best with Klarion wash (0.01% sodium hydroxide). Therefore, guidelines for cleaning and disinfection of ultrasonic probes was required, and further development of probe-only disinfectants is required.

Study on As Removal from Mine Tailing using MGS Gravity Separator (다중비중선별기를 이용한 광물찌꺼기로부터 비소제거 연구)

  • Kim, Jun-Hee;Kim, Min-Gyu;Kim, Woo-Ram;Han, Oh-Hyung
    • Resources Recycling
    • /
    • 제23권5호
    • /
    • pp.36-43
    • /
    • 2014
  • It comtained various kinds of heavy metal in beneficiatian tailing and in order to eliminate the heavy metals, various technologies have been researched, But there are a limits because many problems and restrictions are accompanied. Therefore, in this study, in order to solve this problem, It was performed gravity separation using melti-gravity seperator (MGS) to remove As contained in tailing, which can sort out even the fine particle. It was attempted a study to remove As, which is a kind of heavy metals, by MGS gravity separation and verified the impact by slope, wash water, pulp density, rotational speed and feed rate. In the results of performing gravity concentration under the condition with the MGS slope of $3^{\circ}$, wash water of 5 l/mm, pulp density of 30%, rotational speed of 208 rpm, and the feed rate of 265.24 g/mm, the As removal rate of 88.21% and yield of 92.25% were obtained.

Surface Water Contamination around the Sudokwon Landfill Site (수도권 매립지 주변의 지표수 오염에 관한 연구)

  • Lee, In-Hyun;Jang, Won;Back, Young;Doh, Kap-Soo;Choi, Jae-Gyu
    • Journal of Environmental Science International
    • /
    • 제6권6호
    • /
    • pp.679-688
    • /
    • 1997
  • In order to analyze the water quality variation of surface water around the Sudokwon landfill site, seasonal variations of water temperature, pH, DO. HOD, COD, SS, NH3-N, NO2-N, and NO3-N were examined at 10 sites from January to December, 1996. It was found that the estimates of COD, DO. SS, and $NH_3-N$ were Increased compared with the results of environmental Impact assessment carried out In 1988. Higher estimates of COD, DO, and SS were due to Industrial and agricultural wastewater, and the Increase of NH3-N at Jangdo reservoir strate was due to the leachate from the landfill. In particular, the estimate of 55 was found to be increased by the soil wash from the landfill during the heavy rainy days.

  • PDF

Assessing the impact of urbanization on runoff and non-point source pollution using the GIS L-THIA (GIS L-THIA를 이용한 도시화에 따른 유출과 비점원오염 영향 평가)

  • Yun, La-Young;Kim, Dong-Hui;Gwon, Hyeok-Hyeon;Sin, Seung-Cheol;Son, Kwang-Ik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1802-1806
    • /
    • 2006
  • It is important to consider the effects of land-use changes on surface runoff, stream flow, and groundwater recharge. Expansion of urban areas significantly impacts the environment in terms of ground water recharge, water pollution, and storm water drainage. Increase of impervious area due to urbanization leads to an increase in surface runoff volume, contributes to downstream flooding and a net loss in groundwater recharge. Assessment of the hydrologic impacts or urban land-use change traditionally includes models that evaluate how land use change alters peak runoff rates, and these results are then used in the design of drainage systems. Such methods however do not address the long-term hydrologic impacts of urban land use change and often do not consider how pollutants that wash off from different land uses affect water quality. L-THIA (Long-Term Hydrologic Impact Assessment) is an analysis tool that provides site-specific estimates of changes in runoff, recharge and non point source pollution resulting from past or proposed land-use changes. It gives long-term average annual runoff for a land use configuration, based on climate data for that area. In this study, the environmental and hydrological impact from the urbanized basin had been examined with GIS L-THIA in Korea.

  • PDF

A Study of the first stage Rain-Water exclusion by hydrophilic coating (친수코팅에 의한 초기우수 배제에 관한 연구)

  • Choi, Won Jun;Kim, Young Jung;Shim, Young Mean;Oh, Hye Cheol;Rhee, Dong Seok
    • Journal of Industrial Technology
    • /
    • 제26권A호
    • /
    • pp.189-197
    • /
    • 2006
  • Water shortage as well as water control problems including urban flood and drought have led to developing technologies for rainwater utilization in order to provide a sustainable water supply. However, relatively few works have been done to improve the water quality during rainwater utilization. Therefore, in this study, the characteristics of rainwater were examined in terms of pollutant concentrations and outflow rate. A experimental rain and roof model($1m{\times}1m$) were produced to evaluate wash-off properties of pollutants. And rainfall intensity were standardized in 10 mm/hr, a experimental model roof catchment surface were coated in $TiO_2$ photocatalyst. Samples of runoff rainwater collected from a experimental model were analyzed for physicochemical parameters such as Turbidity, Suspended Solid, EC. The results show that the first flush of rainwater contains substantial amount of contaminants that potentially pollute the whole rainwater. Surface treatment of roof catchment area using $TiO_2$ photocatalyst allowed a better runoff property of rainwater because of its improved hydrophilicity.

  • PDF

Evaluation of effects of textile wastewater on the quality of cotton fabric dye

  • Kaykioglu, Gul;Ata, Reyhan;Tore, Gunay Yildiz;Agirgan, Ahmet Ozgur
    • Membrane and Water Treatment
    • /
    • 제8권1호
    • /
    • pp.1-18
    • /
    • 2017
  • In this study, reuse of biologically treated wastewater of denim washing and dyeing industry has been evaluated by membrane technologies. After that experiments were carried out at laboratory scale in textile dyeing unit by using obtained permeate water samples on 100% cotton based raw fabric belonging to examined industry. During membrane experiments, two different UF (UC100 and UC030) and two different NF (NP010 and NP030) were evaluated under alternative membrane pressures. In permeate water obtained on selected samples, conductivity at the range of $1860-2205{\mu}S/cm$, hardness at the range of 60 to 80 mg/L, total color at the range of 2.4 to 7.6 m-1 and COD at the range of 25-32 mg/L was determined. The following analyzes were performed for the dyed fabrics: perspiration fastness, rub fastness, wash fastness, color fastness to water, color fastness to artificial light, color measurement through the fabric. According to analysis results, selected permeate water have no negative impact on dyeing quality. The study showed that membrane filtration gave good performance for biologically treated textile wastewater, and NF treatment with UF pre-treatment was suitable option for reuse of the effluents.

Choline chloride-Glycerol (1:2 mol) as draw solution in forward osmosis for dewatering purpose

  • Dutta, Supritam;Dave, Pragnesh;Nath, Kaushik
    • Membrane and Water Treatment
    • /
    • 제13권2호
    • /
    • pp.63-72
    • /
    • 2022
  • Choline chloride-glycerol (1:2 mol), a natural deep eutectic solvent (NADES) is examined as a draw solution in forward osmosis (FO) for dewatering application. The NADES is easy to prepare, low in toxicity and environmentally benign. A polyamide thin film composite membrane was used. Characterization of the membrane confirmed porous membrane structure with good hydrophilicity and a low structural parameter (722 ㎛) suitable for FO application. A dilute solution of 20% (v/v) NADES was enough to generate moderate water flux (14.98 L m-2h-1) with relatively low reverse solute flux (0.125 g m-2h-1) with deionized water feed. Application in dewatering industrial wastewater feed showed reasonably good water flux (11.9 L m-2h-1) which could be maintained by controlling the external concentration polarization and fouling/scaling mitigation via simple periodic deionized water wash. In another application, clarified sugarcane juice could be successfully concentrated. Recovery of the draw solute was accomplished easily by chilling utilizing thermo responsive phase transition property of NADES. This study established that low concentration NADES can be a viable alternative as a draw solute for dewatering of wastewater and other heat sensitive applications along with a simple recovery process.

Analyses of Reliability for a Typical Solar Heating System (태양열 난방시설 신뢰도 평가 에 관한 연구)

  • 장광규;전문헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제7권3호
    • /
    • pp.241-248
    • /
    • 1983
  • In the present work a time-dependent reliability model for a typical solar domestic hot water and heating system is developed using the method of Fault Tree Analysis and existing mathematical techniques. The reference system used in this analysis is a typical solar heating system. The system reliability structure has been identified with the aid of Fault Tree methods. In addition, a simulation of the solar system reliability has been performed employing the Monte Carlo method. In the computer simulation, failure rate data such as WASH-1400, MIL-HDBK-217B, and Green and Bourne are used as input data. These results show that the developed reliability model is capable of expressing the primary failure phenomena of the solar heating and domestic hot water system.

Analysis for Flood control in Hwapocheon watershed using WashLand (천변저류지를 활용한 화포천 유역에서의 홍수조절능력에 관한 연구)

  • Park, Chang-Kun;Park, Jae-Hyeon;Lee, Jong-Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.331-335
    • /
    • 2007
  • 본 연구에서는 과거 홍수 피해가 빈번히 발생 하였던 김해 화포천 유역의 홍수 위험도를 산정하고 이를 통해 천변 저류지의 기능인 홍수조절과 생태적인 기능을 검토하고 제시하고자 한다. 화포천의 경우 과거 홍수에 취약한 지역으로 화포천의 수위가 낙동강 본류의 수위보다 낮아 내수배제의 방식으로 홍수를 대비하여 왔다. 하지만 최근 늘어난 집중호우와 이상기후 등으로 배수 용량 증설과 제방고 상승과 같은 구조적인 방법을 통해 대비를 하고 있으나 많은 문제점을 가지고 있어 잠재적인 피해위험에 노출되어 있는 실정이다. 따라서 본 연구에서는 김해시 화포천 유역을 연구대상 유역으로 하여 내수배제의 유역에서 천변저류지 설치를 고려할 경우 어떠한 문제점이 있으며, 위치에 따라 수문학적으로 어떠한 효과가 다르게 나타나는지 분석하였다. 이를 위해 본 연구에서는 우선 과거 홍수 피해가 빈번히 발생 하였던 김해 화포천 유역의 홍수 위험도를 산정하였으며, 이를 방어하기 위한 천변 저류지 설치 시나리오를 설정하고 각 경우에 따른 홍수조절특성을 분석하여 화포천과 같이 내수배제 하천에서 홍수방어를 위해 고려해야 할 조건들을 검토하였다.

  • PDF

Field Measurement and Analysis of Fluvial Sediment in the Cheongmi-Stream(II) - Mineralogical and Contaminative Characteristics of Sediment Particles - (청미천에서의 하천 유사 측정 및 분석(II) - 유사의 광물특성 및 오염도 -)

  • 우효섭;이진국
    • Water for future
    • /
    • 제24권3호
    • /
    • pp.49-60
    • /
    • 1991
  • As a second part of the study entitled "Field Measurement and Analysis of Fluvial Sediment in the Cheongmi-Strea", this study concerns mineralogical and contaminative characteristics of sediment particles collected at Wonbu-Gyo and Hanpyeong-Gyo in the Cheongmi-Stream. The mineralogical analysis of the bed sediment collected reveals that, in general , quarz is the most abundant mineral found in sands with feldspars and rock fragments in the next, which confirms what is known in the literature. The shape factor of sand particles is about 0.7, which also agrees to what is known in the foreign literature. The analysis also reveals that the clay particles collected are composed mainly of illite, kaolinate, and chlorite. The analysis of contamination reveals that there is no substantial difference between the contents of organic material and heavy metals in the surface water and those in the pore water beneath the river bed. It is because the sampling for this analysis was conducted right after the September flood during which the fresh top soil from the upstream watershed replaced the old bed sediment and pore water that would probably be more contaminated. The contents of geavy metals in the bed sediment of sand particles do not exceed those in the soils adjacent to the river. For fine sediment such as clays, however, the contents of heavy metals, especially of mercury and zinc, far exceed those in the soils adjacent to the river. These fine sediments are transported downstream in the form of wash load and deposited in part on flood plains, which could be a new source of contaminants.taminants.

  • PDF