• 제목/요약/키워드: water transmission

검색결과 988건 처리시간 0.037초

기모가공 조건에 따른 트리코 기포 인조 스웨이드의 태와 물성 (Subjective Hand and Physical Properties of Tricot based Artificial Suede according to Raising Finish)

  • 노의경;오경화
    • 한국의류산업학회지
    • /
    • 제16권1호
    • /
    • pp.153-159
    • /
    • 2014
  • This study evaluates the changes of the subjective hand, preference, comfort and mechanical properties of tricot based artificial suede made from sea-island type micro fibers according to raising condition. The subjective hand and the preference of raised suede for jacket were rated by the 20's and 30's women experts according to raising cycles. Comfort properties were evaluated by air permeability, water vapor transmission, and thermal transmission. Mechanical properties were measured by the KES-FB system. The subjective hand of artificial suede was categorized into three hand factors: smoothness, warmness and thickness. Smoothness, warmness and thickness perception increased with raising cycles which affected hand preference and luxuriousness perception. The thickness and wale density of suede increased with the number of raising. Suede became more compact and less pliable and less stretchable due to increased fabric thickness; in addition, the surface of suede became smoother and compressive since the surface evenness of suede improved with smaller fiber fineness and an increased amount of naps covered the base fabric. Furthermore, water vapor transmission decreased and thermal insulation increased. The best raising conditions for artificial suede was four cycles in which artificial suede was preferred without changes in physical properties.

국내외 공동주택용 창호의 기준 및 성능 조사 (The investigation into the standards and performances of domestic and foreign windows for an apartment house)

  • 송수빈;김영탁;염성곤;윤성환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.330-335
    • /
    • 2008
  • This research aims to investigate the standards and the performances of domestic and foreign windows for and apartment house and to present fundamental data for selecting the optimum window at the step of designing an apartment house. To compare the performances of domestic and foreign windows it is selected 5 major window companies in and 3 major window companies in Japan, and investigated window structure, material, type of opening and closing, window glass and the performances of windows for an apartment house-closing and opening force, repeated closing and opening, thermal resistance, sound transmission loss, air tightness, water tightness, wind resistance. The result of a comparative analysis show that the average thermal resistance of Korean window is higher than Japan's but the average sound transmission loss and water tightness of Korean window is lower than Japan's and the rest of the performances is similar.

  • PDF

하이드로폰 송신 어레이를 이용한 수중 음향 통신 시스템의 성능 향상 (Performance Enhancement of Underwater Acoustic Communication System Using Hydrophone Transmit Array)

  • 이외형;손윤준;김기만
    • 한국음향학회지
    • /
    • 제21권7호
    • /
    • pp.606-613
    • /
    • 2002
  • 본 논문에서는 수중에서 송신 빔 형성기를 이용한 고속 데이터 전송 기법을 연구하였다. 또한 범용 디지털 신호처리 프로세서와 다수의 디지탈-아날로그 변환기를 이용한 시험용 송신단을 설계 및 구현하였으며, 구현된 시스템을 이용하여 수조에서 실험을 수행하여 그 성능을 분석하였다. 이때 실험 과정을 단순화하기 위하여 채널 코딩 및 등화기 (equalizer) 등과 같은 과정은 생략하였고, 간장 간단한 디지털 통신 변조 기법인 OOK(On-Off keying) 기법을 사용하였다. 실험 결과 5개의 하이드로폰 송신 어레이를 사용한 경우에 1개만 사용했을 때보다 오차율 10/sup -2/을 기준으로 전송 속도가 약 3배 향상되었으며, 실험에 사용된 수조에서 음성 신호 전송을 위해 400 bps 정도까지 가능함을 확인하였다.

기존온수온돌과 조립식 온수온돌의 전열특성에 관한 실험적 연구 (An Experimental Study on Heat Transmission Characteristics of the Conventional and Prefabricated Ondol)

  • 민정현;이충구;장문석
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.611-621
    • /
    • 1995
  • The objectives of this study are to find out and to analyze the heat transmission characteristics of the conventional and prefabricated Ondol systems. To compare the thermal characteristics of these Ondol, a real sized Ondol model is set in a chamber. Hot water whose temperature is varied from $45^{\circ}C$ to $60^{\circ}C$ with $5^{\circ}C$ interval is supplied to each Ondol system. At that time the temperature distribution of floor surface, the amount of supplied heat, the heat radiation aspect and the heat loss from the floor to the underground are measured and analyzed simultaneously. As a result, even if the supplied hot water temperature to the prefabricated Ondol panel is lower by about $5^{\circ}C$ than that of the conventional Ondol panel, the net radiant effect is same. Heat radiation efficiency of the prefabricated Ondol panel is over 5% better than that of the conventional Ondol panel. It takes 12 hours for the conventional Ondol and 45 minutes for the prefabricated Ondol, respectively to reach steady state.

  • PDF

Numerical modeling on the stability of slope with foundation during rainfall

  • Tran, An T.P.;Kim, Ah-Ram;Cho, Gye-Chun
    • Geomechanics and Engineering
    • /
    • 제17권1호
    • /
    • pp.109-118
    • /
    • 2019
  • The movement of soil along a slope during rainfall can cause serious economic damage and can jeopardize human life. Accordingly, predicting slope stability during rainfall is a major issue in geotechnical engineering. Due to rainwater penetrating the soil, the negative pore water pressure will decrease, in turn causing a loss of shear strength in the soil and ultimately slope failure. More seriously, many constructions such as houses and transmission towers built in/on slopes are at risk when the slopes fail. In this study, the numerical simulation using 2D finite difference program, which can solve a fully coupled hydromechanical problems, was used to evaluate the effects of soil properties, rainfall conditions, and the location of a foundation on the slope instability and slope failure mechanisms during rainfall. A slope with a transmission tower located in Namyangju, South Korea was analyzed in this study. The results showed that the correlation between permeability and rainfall intensity had an important role in changing the pore water pressure via controlling the infiltrated rainwater. The foundation of the transmission tower was stable during rainfall because the slope failure was estimated to occur at the toe of the slope, and did not go through the foundation.

시계열분석(時系列分析)에 의한 배수량추정(配水量推定) (Estimation of Water Distributed Volume Using Time Series Analysis)

  • 이정환;정춘웅;오민환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.340-343
    • /
    • 1992
  • In this paper, To estimate monthly water distribution volume required optimization control of operating scheme & water distribution management for water transmission system in water supply, both Thomas-Fiering technique and Fourier series are compared and analyzed, respectively. Since water distribution volume is periodically repeated and has a linear fluctuation trend, parameters in each element are estimated through dividing into linear fluctuation trend component and periodical component. Finally, results of time-series analysis are proved to be more reasonable than that of Thomas-Fiering techniques by comparing simulation with observation data.

  • PDF

Improvement in the Negative Bias Stability on the Water Vapor Permeation Barriers on ZnO-based Thin Film Transistors

  • 한동석;신새영;김웅선;박재형;박종완
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.450-450
    • /
    • 2012
  • In recent days, advances in ZnO-based oxide semiconductor materials have accelerated the development of thin-film transistors (TFTs), which are the building blocks for active matrix flat-panel displays including liquid crystal displays (LCD) and organic light-emitting diodes (OLED). In particular, the development of high-mobility ZnO-based channel materials has been proven invaluable; thus, there have been many reports of high-performance TFTs with oxide semiconductor channels such as ZnO, InZnO (IZO), ZnSnO (ZTO), and InGaZnO (IGZO). The reliability of oxide TFTs can be improved by examining more stable oxide channel materials. In the present study, we investigated the effects of an ALD-deposited water vapor permeation barrier on the stability of ZnO and HfZnO (HZO) thin film transistors. The device without the water vapor barrier films showed a large turn-on voltage shift under negative bias temperature stress. On the other hand, the suitably protected device with the lowest water vapor transmission rate showed a dramatically improved device performance. As the value of the water vapor transmission rate of the barrier films was decreased, the turn-on voltage instability reduced. The results suggest that water vapor related traps are strongly related to the instability of ZnO and HfZnO TFTs and that a proper combination of water vapor permeation barriers plays an important role in suppressing the device instability.

  • PDF

열펌 시술시 수분함량에 따른 모발의 물리적·형태학적 특성 변화 (Physical and Morphological Characteristics Change of Hair according to Water Content when Heat Permanent Wave is treated)

  • 이순희;김성남
    • 한국의류산업학회지
    • /
    • 제10권3호
    • /
    • pp.389-393
    • /
    • 2008
  • The purpose of this study is to provide beauticians with the fundamental material for them to use effectively heat permanent wave and satisfy their customers. It carried out an experiment with hair of a woman in her late twenties to investigate the change of physical and morphologic characteristics by its water content when performing heat permanent wave. It evaluated the water content as 0g, 1g, 2g, 3g and 4g respectively when performing the heat permanent wave on hair, then it compared and observed the wave type, tensile strength and elongation for its physical change also observed the morphologic change by scanning electronic microscope and transmission electronic microscope. The result of experiment on the physical specificity revealed that the wave was the most ideal when the water content was 2 g. The material with much water content made wave but the result was not satisfied. In the case of hair with water content of nearly 0g didn't make wave. In terms of tensile strength and elongation, the tensile strength was generally reduced as hair was damaged, on the contrary, the elongation was increased. It observed the change of morphologic characteristic and got the result that the damage on hair cuticle was deepen as its water content was decreased. It also showed the result that damage happened on hair cuticle more than hair cortex with the observation of fine structure on hair section by transmission electronic microscope. Generally chemical treatment damaged hair. Under consideration of this aspect, the ultimate goal of this thesis is to minimize the damage of hair caused by chemical treatment and get the satisfaction on the hair style. The result of experiment presented that the hair showed the best result when its water content was 2 g.

가정식난방배수관내의자동온도송신장치에대한연구 (The Study on Automatic Temperature Transmission System for the Heating pipe at Home)

  • 박철민;조형국;이훈재
    • 한국정보통신학회논문지
    • /
    • 제13권12호
    • /
    • pp.2641-2646
    • /
    • 2009
  • 가정 가사생활을 자동으로 관리 하는 Home Automation System은 점차 발전하고 있으며, 에너지의 절약과 재사용에 관한 부분 또한 점차 관심이 높아지고 있다. 일반 아파트에서 난방은 필수이다. 난방의 방법은 크게 두가지로 나눈다. 하나는 전기를 이용하는 것이고 다른 하나는 온수를 이용하는 것이다. 전기를 이용하면 전기요금의 상승으로 효률적이지 못하다. 그러나 온수를 이용하면 비용 면에서 많은 절감이 된다. 온수를 이용할 때, 온수의 온도가 모든 파이프에서 동일하지 못하다. 그러므로 실내의 온도를 설정치와 일치하지 못할때가 있다. 이러한 문제의 해결은 온수 파이프내에 온도 센서를 부착하여, 이 온도를 실시간으로 전송하고, 수신 측에서 온수의 온도를 조절하면 된다. 본 논문에서는 보일러 내부의 순환 pump가 난방수 순환에 따른 동력을 방바닥 시멘트 몰탈 내부의 소형교류 발전기에 의해서 전기에너지를 얻어 동작하는 저전력 기반의 난방배수관 자동온도 배수장치를 제안한다. 시스템의 전원은 프로펠러 수차 방식을 사용하여 분사수 충돌 방식을 사용하였으며, MCU 모듈은 atmel 사의 ATmega8, 통신모듈을 위하여 Chipcon사의 CC1020을 사용하였다.

고온 다습한 환경에서의 주관적 착용 쾌적감과 관련 물성 변인 (Subjective Evaluation of Wear Comfort and Related Physical Variables under Warm and Humid Condition)

  • 김정화;홍경희;조승식
    • 한국의류학회지
    • /
    • 제21권6호
    • /
    • pp.1021-1030
    • /
    • 1997
  • Physical variables related to the subjective evaluation of wear comfort were explored. Experimental fabrics was those used in the previous paper where subjective sensations of women's thin shirts were reported. Fabrics include 100% cotton (unfinished), 100% cotton (water repellent finished), cotton/polyester 35/65 (unfinished), cotton/polyester 35/65 (peach skin finished), 100% polyester fabric(plain), 100% polyester crepe. Among various physical properties of the experimental fabrics, heat 8E moisture transport properties and surface properties were chosen as important variables based on the regression coefficient. Especially, humidity at the microclimate in dynamic mode was highly correlated to the subjective evaluation and appeared to be a sensitive physical predictor, compared to dry thermal transmission rate or water vapor transmission rate. Surface characteristic parameters, however, did not show consistant trend in the prediction of the human's subjective sensation. Interaction between surface properties and humidity measurement was also observed.

  • PDF